Insulated Copper Pipe works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units, 99.9% Pure copper pipe meets ASTM B280 and C12200 standard, 1/4“-3/8” is the out dimension in inch, 6.35mm - 9.52mm is the out dimension in metric.
Insulated Copper Pipe Split Line Set for Mini Split HVAC
DABUND Insulated Copper Pipe Split Line Set is designed for compatible ductless mini-split, heat-pump, air-conditioning and refrigeration installations. The product combines copper refrigerant tubing with insulation to connect indoor and outdoor HVAC equipment.
The current product range includes copper tube outside diameters from 1/4" to 1 1/8", with available lengths of 15 m (50 ft), 20 m, 25 m, 30 m and 50 m.
The current source also identifies 99.9% pure copper tubing meeting ASTM B280 and C12200, together with multiple insulation thicknesses and custom printing options for company name, size and length information.
Quick Answer: This insulated copper line set is available in multiple copper tube sizes and lengths for compatible mini-split, heat-pump and central air-conditioning applications, with insulated refrigerant tubing designed to connect indoor and outdoor units.
Important Material Notice: The current page source describes the insulation as Polypropylene in one section and also contains original product material labeled “Black Rubber Insulation.” Confirm the exact insulation material for the selected line-set configuration before ordering.
Insulated Copper Line Set Specifications
Product Type
Insulated Copper Pipe Split Line Set
Applications
Ductless mini-split, heat pump, air conditioning, refrigeration and centralized air-ducted units
Copper Tube O.D.
1/4", 3/8", 1/2", 5/8", 3/4", 7/8", 1 1/8"
Available Lengths
15 m (50 ft), 20 m, 25 m, 30 m, 50 m
Copper
99.9% pure copper according to current product information
Copper Standards Listed
ASTM B280 / C12200
Insulation Thicknesses Listed
3/8", 1/2", 3/4", 1"
Insulation Material
Current source contains both Polypropylene and “Black Rubber Insulation” descriptions; confirm exact configuration
Insulation Standards Listed
ASTM E84 / UL94 / ASTM D1056 / ASTM G21
Working Temperature Listed
-40℃ to 120℃
Smoke Rating Listed
25/50
Pressure Rating Listed
2100–7000 PSI across the current product information; confirm exact rating by tube size/configuration
Custom Printing
Company name, size, length/meters and other product identification can be discussed
Available Copper Tube Sizes and Lengths
Specification
Available Options in Current Source
Copper Tube O.D.
1/4", 3/8", 1/2", 5/8", 3/4", 7/8", 1 1/8"
Length
15 m (50 ft), 20 m, 25 m, 30 m, 50 m
Insulation Thickness
3/8", 1/2", 3/4", 1"
Example Inch / Metric O.D.
1/4" = 6.35 mm; 3/8" = 9.52 mm as referenced in current product information
Insulated Copper Line Set
Mini Split Copper Line Set
HVAC Insulated Copper Tubing
Insulated Copper Line Set PDF
View the current DABUND product document for additional insulated copper pipe split line set information.
The insulated copper line set combines refrigerant-grade copper tubing with external insulation to create the refrigerant connection between compatible indoor and outdoor HVAC equipment.
The current product information describes the copper tubing as having good ductility, oxidation resistance and pressure resistance.
Insulation for HVAC Copper Tubing
The current source lists insulation thicknesses of 3/8", 1/2", 3/4" and 1" and identifies UV resistance together with ASTM E84, UL94, ASTM D1056 and ASTM G21.
A working-temperature range of -40℃ to 120℃ and a smoke rating of 25/50 are also listed in the supplied product information.
Because the original source refers to both Polypropylene insulation and “Black Rubber Insulation,” the exact foam or insulation material should be confirmed for each product configuration before technical approval or ordering.
Refrigeration-Grade Copper Tubing
The current product information identifies the tubing as 99.9% pure copper and lists ASTM B280 and C12200.
The copper tubing is described as having good thermal conductivity, ductility, toughness and corrosion resistance for compatible air-conditioning and refrigeration applications.
ASTM B280 and C12200 Copper
ASTM B280 and C12200 are specifically referenced in the current product information for the copper tubing used in the insulated line set.
Buyers requiring material certificates or project documentation should confirm that the required standard and certificate apply to the exact tube size and production batch being purchased.
Copper Line Set Product Details
Copper Tube Performance
The current product description identifies thickened copper tubing with good toughness and hardness.
Good thermal conductivity, ductility and corrosion resistance are also listed among the characteristics of the copper tube.
Pressure Rating
The supplied product information lists a pressure-rating range of 2100 to 7000 PSI across the insulated copper pipe range and references a 700 PSI requirement for R410 applications.
Because pressure capability can vary with copper tube diameter, wall thickness and product configuration, confirm the applicable working and test pressure for the exact line-set size before use.
How an HVAC Copper Line Set Works
A typical split-system line set uses two copper tubes to connect the indoor and outdoor equipment and create the refrigerant piping circuit.
Refrigerant circulates between the indoor and outdoor units through these copper lines as part of the air-conditioning or heat-pump refrigeration cycle.
Mini Split, Heat Pump and HVAC Applications
The current product information identifies the insulated copper line set for multiple HVAC and refrigeration applications.
Ductless mini-split air conditioners
Heat-pump systems
Air-conditioning systems
Refrigeration applications
Centralized air-ducted units
Compatible split-system indoor and outdoor unit connections
Custom Printed Insulation
DABUND produces insulation for the line-set range and the current source states that custom printing can include company name, product size and length information.
Distributors and private-label buyers can confirm printing content, insulation configuration, packaging and order requirements before production.
How to Select an Insulated Copper Line Set
Confirm Both Copper Tube Diameters
Check the required liquid-line and suction-line outside diameters specified for the HVAC equipment. Do not select a line set based only on equipment appearance or nominal system size.
Confirm the Required Length
The current product information lists 15 m (50 ft), 20 m, 25 m, 30 m and 50 m lengths. Select the required length according to the actual indoor-to-outdoor installation route and equipment requirements.
Confirm Insulation Thickness
Available insulation thicknesses listed in the source are 3/8", 1/2", 3/4" and 1". Confirm the required insulation specification for the installation environment.
Confirm Insulation Material
Because the current source contains both Polypropylene and black-rubber insulation descriptions, confirm the exact insulation material and construction for the selected SKU.
Confirm System Requirements
Confirm refrigerant, allowable line length, elevation difference, required copper sizes and other piping requirements specified by the HVAC equipment manufacturer.
Ordering Checklist
Item
Information to Confirm
Copper Sizes
Required liquid-line and suction-line outside diameters
Length
15 m / 20 m / 25 m / 30 m / 50 m or required configuration
Insulation
Material and thickness
Copper Standard
ASTM B280 / C12200 requirements if applicable
Pressure Requirement
Confirm exact rating for selected copper size and wall thickness
Printing
Company name, size, meters and private-label content
Packaging
Confirm required packaging and order quantity
Information to Confirm Before Ordering
HVAC distributors, wholesalers, contractors and professional installers should confirm the following information before ordering:
Liquid-line copper O.D.
Suction-line copper O.D.
Required line-set length
Copper wall thickness
Insulation material
Insulation thickness
Refrigerant-system requirements
Working and test pressure requirements
Required standards or certificates
Custom printing requirements
Order quantity
Packaging and private-label requirements
The current source does not provide a complete size-by-size wall-thickness and pressure table. Confirm these technical parameters for the exact line-set configuration before ordering.
Insulated Copper Line Sets for HVAC Distributors
DABUND supplies insulated copper line sets and related HVAC installation products for distributors, wholesalers, contractors and professional installers.
Copper tube size, insulation thickness, line-set length, custom printing and packaging can be discussed according to commercial purchasing requirements.
Frequently Asked Questions
What is an insulated copper line set used for?
An insulated copper line set connects compatible indoor and outdoor air-conditioning or heat-pump equipment and provides copper piping for refrigerant circulation between the units.
What copper tube sizes are available?
The current product information lists 1/4", 3/8", 1/2", 5/8", 3/4", 7/8" and 1 1/8" outside diameters.
What line-set lengths are available?
The listed lengths are 15 m (50 ft), 20 m, 25 m, 30 m and 50 m.
What insulation thicknesses are available?
The current product information lists 3/8", 1/2", 3/4" and 1" insulation thicknesses.
What insulation material is used?
The current source contains both Polypropylene and “Black Rubber Insulation” descriptions. Confirm the exact insulation material for the selected product configuration before ordering.
What is the working temperature range?
The current product information lists a working-temperature range from -40℃ to 120℃ for the insulation described on the page.
Which insulation standards are listed?
ASTM E84, UL94, ASTM D1056 and ASTM G21 are listed in the current product information. Confirm applicability to the exact insulation configuration and production batch when certification documents are required.
Does the copper tubing meet ASTM B280?
ASTM B280 is specifically listed in the current product information together with C12200 copper. Confirm certificate applicability for the exact tubing being ordered.
Is this line set suitable for mini split systems?
Yes. Ductless mini-split systems are specifically identified as an application in the current product information.
Can it be used with heat pumps?
Yes. Heat-pump applications are also listed, subject to correct copper sizes, line length and equipment requirements.
Can it be used with centralized air-conditioning systems?
Centralized air-ducted units are included among the applications listed in the current product information.
What is the pressure rating?
The current source lists a range of 2100 to 7000 PSI across the product range. Confirm the applicable working and test pressure for the exact tube size, wall thickness and configuration before use.
Can the insulation be custom printed?
Yes. The current product information states that company name, size, length in meters and other identification can be printed on the insulation.
How do I choose the correct mini split line set?
Confirm the required liquid-line and suction-line outside diameters, line-set length, insulation specification and equipment manufacturer's piping requirements before selecting a line set.
How does DABUND control product quality?
The current product information states that pre-production samples are provided before mass production and final inspection is carried out before shipment.
Is DABUND a manufacturer?
Yes. The current product information identifies DABUND as the manufacturer.
Can I request a sample?
Sample requests are available according to the current sales policy. View sample information.
What is the typical delivery time?
The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on copper size, length, insulation configuration, customization, quantity and production schedule.
Used with nuts and bolts and provide a greater bearing surface to prevent the nut or bolt head tearing through the fastened material, flat washers are used to support and spread the load across the baring area of the bolt and nut to prevent pull through.
Suitable to use on the refrigeration system of air conditioner,heat pump water heater,refrigerator and freezer.Please confirm your pipes' specifications before ordering from Dabund.
Copper Y-Joints are used number of commercial and industrial applications due to its versatile design.The size of the branch pipe is small, and it can be installed directly along the direction of the refrigerant pipe.