4-Way Refrigerant Manifold Gauge Set
DABUND 4-Way Refrigerant Manifold Gauge Set is an analog HVACR service tool for monitoring low-side and high-side refrigerant pressure during compatible air-conditioning and refrigeration service procedures.
The product is identified as a 4-way manifold gauge configuration and can support pressure testing, system inspection, troubleshooting, evacuation and refrigerant charging when the gauge set, hoses and connections are correctly matched to the equipment and refrigerant being serviced.
According to the current product information, the manifold uses double O-ring piston valves. Manifold configurations equipped with a sight glass also allow technicians to visually observe liquid during applicable service procedures.
Quick Answer: This is a 4-way analog refrigerant manifold gauge set for HVACR service, with low-side and high-side pressure monitoring and filling hoses shown in the current product information.
Ordering Notice: The current product information does not specify refrigerant compatibility, low-side pressure range, high-side pressure range, manifold port dimensions, hose connection sizes, hose length or hose pressure rating. Confirm these specifications for the exact model before ordering.
4-Way Manifold Gauge Set Specifications
| Product Type | Refrigerant Manifold Gauge Set |
| Manifold Configuration | 4-Way |
| Gauge Type | Analog |
| Pressure Monitoring | Low-side and high-side refrigerant pressure |
| Valve Design | Double O-ring piston valves |
| Sight Glass | Available on manifold configurations equipped with a sight glass |
| Service Hoses | Filling hoses shown in current product information |
| Typical Applications | Compatible air-conditioning and refrigeration service |
| Refrigerant Compatibility | Confirm for the exact model before ordering |
4-Way Manifold for HVACR Service
This product is identified as a 4-way refrigerant manifold gauge set for compatible HVACR service applications.
The manifold configuration provides a service interface for professional technicians working with refrigerant systems, while the analog gauges provide low-side and high-side pressure information.
The current product information does not define the function or connection specification of each individual manifold port. Buyers should confirm the exact port arrangement and connection dimensions for the selected model before ordering.

Testing Manifold Double Meter Valve

Filling Hose
Low-Side and High-Side Pressure Monitoring
The dual analog gauges allow technicians to monitor refrigerant pressure on the low-pressure and high-pressure sides of a compatible HVACR system.
These readings can support system inspection and troubleshooting when interpreted together with the equipment specifications, refrigerant type and actual operating conditions.
The current product information does not provide the exact gauge pressure ranges. Confirm the required low-side and high-side ranges for the intended refrigerant and equipment before ordering.
Air Conditioner Charging and Testing
The manifold gauge set can be used as part of compatible air-conditioning and refrigeration charging and testing procedures.
During applicable service work, pressure readings can support system diagnosis, while the manifold and filling hoses provide the service connection required for compatible procedures.
Refrigerant compatibility, pressure range and connection specifications must be confirmed before connecting the gauge set to a system.
Double O-Ring Piston Valves
The current product information identifies the manifold with double O-ring piston valves.
The valve arrangement forms part of the manifold flow-control system used during compatible HVACR testing, evacuation and charging procedures.
Sight Glass Option
Manifold configurations equipped with a sight glass allow technicians to visually observe liquid movement during applicable service procedures.
The current product information does not confirm that every 4-way manifold configuration includes a sight glass. Buyers requiring this feature should confirm it for the exact model.
Gauge Zero Calibration
Before connecting the manifold to a pressurized system, check whether each analog gauge returns to 0 psi when unpressurized.
According to the current product instructions, if a gauge does not read 0 psi, remove the gauge face and adjust the calibration screw until the pointer returns to 0 psi.
Gauge condition and zero calibration should be checked before performing pressure-dependent service procedures.
HVACR Service Applications
The 4-way refrigerant manifold gauge set is intended for professional servicing of compatible air-conditioning and refrigeration equipment.
Air-conditioning system pressure monitoring
Refrigeration system pressure monitoring
Low-side pressure checking
High-side pressure checking
System inspection and troubleshooting support
Evacuation procedures
Refrigerant charging procedures
HVACR maintenance and repair work
How to Select a 4-Way Refrigerant Gauge Set
Confirm the Refrigerant Type
Identify the refrigerant used by the equipment and confirm that the exact manifold gauge configuration is suitable for that refrigerant.
Confirm the Gauge Pressure Ranges
Verify that the low-side and high-side pressure ranges are suitable for the intended HVACR service application.
Confirm the Gauge Scales and Units
Check the required gauge markings, refrigerant scales and measurement units for the target market and service application.
Confirm the 4-Way Port Configuration
Confirm the function, size and connection type of the manifold ports for the exact model. The current product information does not provide detailed port specifications.
Confirm Service Hose Specifications
Verify hose quantity, hose connection size, hose length and required pressure rating before ordering.
Confirm Whether a Sight Glass Is Required
If a sight glass is required for the intended service procedure, verify that the selected manifold configuration includes this feature.
How to Check the Manifold Gauge Before Use
Step 1: Inspect the Manifold
Inspect the manifold body, analog gauges, valves and filling hoses before connecting the tool to the HVACR system.
Step 2: Check the Gauge Zero Position
Verify that the gauges read 0 psi when the manifold is not pressurized.
Step 3: Adjust Calibration if Required
If a gauge does not return to 0 psi, the current instructions state that the gauge face can be removed and the calibration screw adjusted until the pointer returns to zero.
Step 4: Confirm Refrigerant Compatibility
Confirm that the gauge scales, pressure ranges, hoses and connections are suitable for the refrigerant and equipment being serviced.
Step 5: Check the Hose Connections
Check hose condition and connection compatibility before connecting the manifold gauge set to the system.
Important Safety Notice
Refrigerant manifold gauge sets are professional service tools for pressurized HVACR systems and should be operated by trained personnel following the applicable equipment and refrigerant service procedures.
Caution: Never open the high-side valve on the manifold gauge set while the air-conditioning system is operating.
Check valve positions, gauge condition, refrigerant compatibility and all hose connections before connecting the manifold to a system.
Information to Confirm Before Ordering
HVAC distributors, wholesalers, contractors and refrigeration service companies should confirm the following specifications before ordering:
Required refrigerant compatibility
Low-side gauge pressure range
High-side gauge pressure range
Gauge refrigerant scales
Gauge measurement units
Gauge diameter
4-way manifold port configuration
Manifold port sizes
Service hose connection sizes
Hose quantity
Hose length
Hose working pressure
Whether a sight glass is required
Required package contents
Order quantity
Packaging requirements
OEM or private-label requirements
These technical parameters are not fully specified in the current product information and should be confirmed for the exact 4-way manifold gauge configuration before placing an order.
DABUND 4-Way Manifold Gauge Sets
DABUND supplies refrigerant manifold gauge sets and related HVAC installation and service products for distributors, wholesalers, contractors and professional HVACR service companies.
DABUND has supplied HVAC-related products since 2008.
OEM and ODM requirements can be discussed according to manifold configuration, gauge requirements, hose configuration, packaging and commercial purchasing requirements.
Frequently Asked Questions
What is a 4-way refrigerant manifold gauge set?
This product is identified as a 4-way manifold gauge set for compatible HVACR service applications. The current product information does not specify the detailed function and connection type of each individual manifold port.
What is a 4-way manifold gauge set used for?
It is used for compatible air-conditioning and refrigeration service procedures including low-side and high-side pressure monitoring, system inspection, troubleshooting support, evacuation and refrigerant charging.
Is this an analog or digital manifold gauge?
The current product information and images show an analog manifold gauge configuration.
Does it measure both low-side and high-side pressure?
Yes. The manifold uses analog gauges to monitor low-side and high-side refrigerant pressure during compatible service procedures.
Does the manifold use double O-ring piston valves?
Yes. The current product information identifies the manifolds with double O-ring piston valves.
Does every 4-way manifold include a sight glass?
Not necessarily. The current information states that manifolds equipped with a sight glass allow liquid levels to be viewed. Confirm whether the exact model being ordered includes this feature.
Which refrigerants can this 4-way manifold gauge set service?
The current product information does not identify specific refrigerants for this SKU. Confirm refrigerant compatibility, gauge scales, pressure ranges, hoses and connections before ordering.
Can this gauge set be used for refrigerant charging?
Yes. Refrigerant charging is identified as an applicable manifold gauge procedure when the gauge set is correctly matched to the refrigerant and equipment.
Can it be used during system evacuation?
The current product information identifies evacuation as an applicable service procedure for manifold gauge sets.
What should I do if a gauge does not read 0 psi?
According to the current product instructions, remove the gauge face and adjust the calibration screw until the pointer returns to 0 psi.
What is the pressure range of the gauges?
The current product information does not specify the low-side or high-side pressure ranges. Confirm these values for the exact model before ordering.
What are the four manifold port sizes?
The current product information does not provide the dimensions or connection types of the individual manifold ports. Confirm the exact port specifications before ordering.
Are filling hoses included?
Filling hoses are shown in the current product information. Confirm the exact hose quantity, length, connection sizes and package contents for the selected configuration.
Can I open the high-side valve while the AC system is operating?
No. The current product instructions specifically caution against opening the high-side manifold valve while the air-conditioning system is operating.
Is this tool intended for professional HVACR service?
Yes. Refrigerant manifold gauge sets are used for servicing pressurized HVACR systems and should be operated by trained personnel following the applicable equipment and refrigerant service procedures.
Can DABUND provide OEM or ODM 4-way manifold gauge sets?
Yes. OEM and ODM requirements can be discussed according to manifold configuration, gauge requirements, hose configuration, packaging and commercial order requirements.
Can I request a sample?
Sample requests are available according to the current sales policy. View sample information.
What payment terms are available?
Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.
What delivery terms are available?
Available international trade terms can include EXW, FOB, CFR and CIF.
What is the typical delivery time?
The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on order quantity, product configuration, customization and production schedule.