Home Copper Pipe Insulated Copper Tube 30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
30 ft 1/4" x 5/8" Insulated Copper Tube
1.Insulated copper pipe including one set air conditioner insulated copper pipe, size 1/4"+5/8"30 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts. 
2. Both of the two copper pipe end do flaring and nuts. 
3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm. 
4. For the insulated copper pipe, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m. 
5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200. 
6.Professional manufacturer of insulated copper pipe, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 10M

Material

99.9% pure copper

Color

Black/White

Keywords

Mini Split Installation Kit

Application

HVAC
Inquire
Add to Basket

30 Ft 1/4" x 5/8" Insulated Copper Tube

DABUND 30 Ft 1/4" x 5/8" Insulated Copper Tube is a pre-insulated copper line set for compatible HVACR and split air-conditioning systems requiring 1/4-inch and 5/8-inch refrigerant tubing.

This configuration is supplied with 1/2" White PE insulation according to the current product information. Both copper tubes have factory-prepared flared ends and nuts for compatible flare-type HVAC connections.

The copper tubing is identified with ASTM B280 and C12200 DHP references. The 30 ft configuration is intended for installations where the actual HVAC equipment permits this piping length and requires the 1/4" x 5/8" tubing combination.

Quick Answer: This is a 30 ft 1/4" x 5/8" insulated copper line set with 1/2" White PE insulation, factory-prepared flared ends and nuts for compatible HVACR installations.

Compatibility Notice: The current DABUND product information associates 1/4" x 5/8" tubing with some approximately 2–2.5 ton or 24,000–30,000 BTU air-conditioning systems. This is only a general reference. Always confirm the required liquid and suction line sizes in the equipment manufacturer's installation documentation.

30 Ft 1/4" x 5/8" Copper Line Set Specifications

Product TypePre-Insulated Copper Tube / Copper Line Set
Tube Size1/4" x 5/8"
Length30 ft
Current Insulation1/2" White PE
Copper Tube ReferenceASTM B280 / C12200 DHP
Tube End PreparationFlared ends with nuts
Insulation TypeClosed-cell polyethylene-based insulation system according to current product information
Listed Inner Layer Temperature Range-40°C to 120°C
General Capacity ReferenceSome 24K–30K BTU / approximately 2–2.5 ton systems; equipment specification governs actual sizing

30 Ft Pre-Insulated Copper Line Set

The 30 ft configuration combines 1/4" and 5/8" copper tubing with factory-applied White PE insulation for compatible HVAC installations.

Pre-insulated construction reduces the amount of separate insulation work required around the refrigerant tubing at the installation site and provides an integrated insulated piping configuration.

The selected 30 ft length should be checked against the minimum and maximum refrigerant-line lengths permitted by the actual HVAC equipment manufacturer before installation.

ASTM B280 and C12200 Copper Tubing

The current product information identifies the copper tubing with ASTM B280 and C12200 DHP references for HVACR copper tube applications.

The product imagery also identifies the tubing as 99.9% pure copper.

Required tube wall thickness and operating requirements should be confirmed according to the actual HVAC equipment and project specification.

Factory-Prepared Flared Ends with Nuts

Both copper tube ends are supplied with factory-prepared flares and nuts according to the current product information.

Before connection, inspect the flare surfaces and verify that the flare dimensions, nuts and connection method are compatible with the equipment service valves.

Copper tubing for 30 ft 1/4 x 5/8 insulated copper line set

99.9% Pure Copper

White PE insulated copper tubing for HVACR applications

White PE Insulated Pipe

Copper flare nuts for insulated HVAC copper tubing

Copper Nuts

1/2" White PE Insulation

This 30 ft 1/4" x 5/8" SKU is identified with 1/2" White PE insulation in the current product information.

The insulation system is described as a multilayer construction designed to provide thermal insulation and environmental protection around the refrigerant tubing.

White PE embossed multilayer insulation for HVAC copper tubing

White PE Three-Layer Insulation Structure

Outer Layer: Embossed PE Film

The source describes the outer layer as an anti-aging and UV-resistant PE film with an embossed, wear-resistant surface.

Middle Layer: IXPE Foam

The middle layer is identified as IXPE foam with a dense-cell structure for thermal insulation and impact absorption.

Inner Layer: Closed-Cell Insulation

The inner layer is described as a closed-cell structure providing thermal insulation. The current product information lists a temperature range from -40°C to 120°C for this layer.

Production equipment for thermal insulation tubing

Insulation Pipe Production

Warehouse for insulated HVAC tubing

Insulated Pipe Warehouse

Closed-cell inner layer of insulated HVAC tubing

Inner Insulation Layer

Insulation Performance References

The current product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for insulation-related testing.

It also references ASTM C1427-07 and UL723 surface-burning characteristics in the insulation information. Buyers requiring specific reports or classifications should confirm that the applicable documentation matches the exact White PE insulation configuration being ordered.

HVAC Installation Accessories

The current product information references an installation package that can include insulated copper tubing together with communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts.

Exact package contents should be confirmed specifically for the 30 ft 1/4" x 5/8" SKU before placing distributor, contractor or project orders.

30 ft 1/4 x 5/8 White PE insulated copper tubing with HVAC installation accessories

Available White PE Insulated Copper Tube Sizes

DABUND supplies multiple copper tube combinations, insulation thicknesses and tubing lengths across the insulated copper tube product range.

Copper Tube SizeAvailable LengthsWhite PE Insulation OptionsListed Flame Class
1/4" + 3/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4" + 1/2"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4" + 5/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 5/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 3/4"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2" + 3/4"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 7/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

Note: The table above represents the wider White PE insulated copper tubing range. This page specifically covers the 30 ft 1/4" x 5/8" configuration with 1/2" White PE insulation.

1/4" x 5/8" Line Set for Compatible 24K–30K Systems

The current DABUND product information associates 1/4" x 5/8" refrigerant tubing with some approximately 2–2.5 ton or 24,000–30,000 BTU air-conditioning systems.

This is a general product-family reference rather than a universal compatibility rule.

Different HVAC models with the same nominal capacity can require different liquid and suction line sizes. Always confirm the required refrigerant tubing dimensions in the equipment manufacturer's installation manual.

Important Checks for a 30 Ft Refrigerant Line

Confirm the Required Tube Sizes

Verify that the actual HVAC equipment specifically requires 1/4" and 5/8" refrigerant tubing.

Check Maximum Permitted Line Length

Confirm that a 30 ft piping route remains within the maximum refrigerant-line length permitted by the equipment manufacturer.

Check Minimum Permitted Line Length

Some HVAC equipment also specifies a minimum permitted refrigerant-line length. Follow the manufacturer documentation if the actual route is shorter.

Confirm Vertical Separation

If the indoor and outdoor equipment are installed at different elevations, confirm the maximum permitted vertical separation for the actual system.

Check Refrigerant Charge Requirements

Check the equipment factory refrigerant charge and the piping length included in that charge. Follow the manufacturer's instructions if refrigerant adjustment is required for the installed piping length.

How to Install a 30 Ft 1/4" x 5/8" Copper Line Set

Step 1: Verify Equipment Compatibility

Check the equipment model and verify that 1/4" x 5/8" is the required refrigerant-line size.

Step 2: Plan the Piping Route

Plan the route between the indoor and outdoor equipment and confirm that the selected 30 ft length complies with the equipment manufacturer's piping limits.

Step 3: Protect the White PE Insulation

Avoid crushing, cutting or excessively abrading the insulation while routing the tubing through walls, ceilings or other building structures.

Step 4: Inspect the Flared Ends

Inspect the factory-prepared flare surfaces and nuts before connecting them to compatible equipment service valves.

Step 5: Make the Refrigerant Connections

Follow the HVAC equipment manufacturer's flare-joint connection and tightening requirements.

Step 6: Leak Test and Evacuate

Complete the required leak testing and evacuation procedures according to the equipment manufacturer's instructions before system operation.

Step 7: Confirm Refrigerant Charge

Confirm that the installed piping length and refrigerant charge comply with the equipment manufacturer's requirements before commissioning.

HVACR Applications

The 30 ft 1/4" x 5/8" insulated copper line set can be considered for compatible HVACR systems that specifically require this tubing combination and permit the selected piping length.

  • Compatible split air-conditioning systems

  • Compatible ductless mini split systems

  • Compatible heat-pump installations

  • HVAC equipment requiring 1/4" x 5/8" refrigerant tubing

  • Some compatible 24K–30K BTU applications

  • Medium-length indoor-to-outdoor refrigerant piping routes

Compatibility must always be verified using the exact HVAC equipment model and manufacturer documentation.

Information to Confirm Before Ordering

HVAC distributors, wholesalers, contractors and professional buyers should confirm the following information before ordering:

  • Required copper tube size: 1/4" x 5/8"

  • Required line-set length: 30 ft

  • HVAC equipment model

  • Minimum and maximum permitted piping length

  • Vertical separation requirements

  • Required insulation material and thickness

  • Required package accessories

  • Order quantity

  • Packaging requirements

  • OEM or private-label requirements

DABUND Insulated Copper Tube Manufacturer

DABUND has produced insulated copper pipe, insulated copper tubing, mini split line sets and related HVAC installation products since 2008.

Multiple copper tube combinations, insulation configurations and piping lengths are available for HVAC distributors, wholesalers, contractors and professional buyers.

OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.

DABUND Factory

DABUND produces insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation products.

DABUND factory producing insulated copper tubing and HVAC line sets

Test Documentation

The current product information references insulation testing including ASTM E84, UL94, ASTM D1056 and ASTM G21.

Buyers requiring a particular report or classification should confirm that the requested documentation applies to the exact White PE insulation configuration being ordered.

Test documentation for DABUND insulated copper tubing

Exhibition

DABUND presents insulated copper tubing, mini split line sets and related HVAC installation products at industry exhibitions for international buyers.

DABUND insulated copper tubing and line sets displayed at HVAC exhibitions

Frequently Asked Questions

What size is this insulated copper tube?

This product uses 1/4" and 5/8" copper tubing.

How long is this copper line set?

This product is supplied in a 30 ft length.

What insulation is used on this product?

The current product information identifies this configuration with 1/2" White PE insulation.

What is the White PE insulation structure?

The current product information describes an embossed PE outer film, an IXPE middle layer and a closed-cell inner insulation layer.

What copper standards are listed?

The current product information identifies ASTM B280 and C12200 DHP references for the copper tubing.

Are the copper tube ends flared?

Yes. Both copper tube ends are described as flared and supplied with nuts.

What temperature range is listed for the inner insulation layer?

The current product information lists a temperature range from -40°C to 120°C for the closed-cell inner insulation layer.

What system capacity commonly uses 1/4" x 5/8" tubing?

The current DABUND product information associates 1/4" x 5/8" tubing with some approximately 2–2.5 ton or 24,000–30,000 BTU air-conditioning systems. This is only a general reference.

Can this line set be used with every 24,000 or 30,000 BTU air conditioner?

No. Different HVAC models can require different refrigerant tubing sizes even when nominal capacity is similar. Confirm the required tubing in the equipment installation manual.

Is 30 ft suitable for every HVAC installation?

No. Confirm that 30 ft falls within the minimum and maximum refrigerant piping lengths permitted by the actual HVAC equipment manufacturer.

Does a 30 ft line require additional refrigerant?

It depends on the HVAC equipment. Check the factory refrigerant charge, included piping-length allowance and refrigerant adjustment instructions provided by the manufacturer.

Does vertical separation matter?

Yes. Confirm the permitted elevation difference between indoor and outdoor equipment in the manufacturer's installation documentation.

Can this insulated copper tube be used with a heat pump?

It can be considered for compatible heat-pump equipment that specifically requires 1/4" x 5/8" refrigerant tubing and permits the selected piping length.

What accessories can be supplied?

The current product information references communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts. Confirm the exact package contents for this 30 ft 1/4" x 5/8" SKU before ordering.

Are other copper tube sizes available?

Yes. The current product range includes 1/4" x 3/8", 1/4" x 1/2", 1/4" x 5/8", 3/8" x 5/8", 3/8" x 3/4", 1/2" x 3/4" and 3/8" x 7/8" combinations.

Can DABUND provide OEM or ODM insulated copper tubing?

Yes. OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.

Can I request a sample?

Sample requests are available according to the current sales policy. View sample information.

What payment terms are available?

Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.

What trade terms are available?

Available international trade terms can include EXW, FOB, CFR and CIF.

What is the typical delivery time?

The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on order quantity, product configuration, customization and production schedule.

Related Products

1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 3/8" x 3/4" is the out dimension in inch. 9.52mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 3/8" x 3/4" is the out dimension in inch. 9.52mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.