30 Ft 3/8" x 5/8" Insulated Copper Pipe
DABUND 30 Ft 3/8" x 5/8" Insulated Copper Pipe is a pre-insulated copper line set for compatible HVACR and ductless split air-conditioning systems requiring 3/8-inch and 5/8-inch refrigerant tubing.
This configuration is supplied with 1/2" White PE insulation according to the current product information. Both copper tubes have factory-prepared flared ends and nuts for compatible flare-type HVAC connections.
The copper tubing is identified with ASTM B280 and C12200 DHP references. The 30 ft configuration is intended for installations where the HVAC equipment manufacturer permits this piping length and requires the 3/8" x 5/8" tubing combination.
Quick Answer: This is a 30 ft 3/8" x 5/8" insulated copper line set with 1/2" White PE insulation, factory-prepared flared ends and nuts for compatible HVACR installations.
Compatibility Notice: The current DABUND product information associates 3/8" x 5/8" tubing with some approximately 3–4 ton or 36,000–48,000 BTU ductless air-conditioning systems. This is a general reference only. Always confirm the required liquid and suction line sizes in the actual equipment installation manual.
30 Ft 3/8" x 5/8" Copper Line Set Specifications
| Product Type | Pre-Insulated Copper Pipe / Copper Line Set |
| Tube Size | 3/8" x 5/8" |
| Length | 30 ft |
| Current Insulation | 1/2" White PE |
| Copper Tube Reference | ASTM B280 / C12200 DHP |
| Tube End Preparation | Flared ends with nuts |
| White PE Structure | Embossed PE outer film, IXPE middle layer and closed-cell inner insulation layer according to current product information |
| Listed Inner Layer Temperature Range | -40°C to 120°C |
| General Capacity Reference | Some 36K–48K BTU / approximately 3–4 ton systems; actual equipment specification governs |
30 Ft Pre-Insulated Copper Line Set
The 30 ft configuration combines 3/8" and 5/8" copper tubing with factory-applied White PE insulation for compatible HVAC installations.
Pre-insulated construction reduces the amount of insulation work required around the refrigerant tubing at the installation site and provides an integrated insulated piping solution.
The selected 30 ft piping length should still be checked against the minimum and maximum refrigerant-line lengths permitted by the actual HVAC equipment manufacturer.
ASTM B280 and C12200 Copper Tubing
The current product information identifies the copper tubing with ASTM B280 and C12200 DHP references for HVACR copper tube applications.
Product imagery also describes the tubing as 99.9% pure copper.
Required tube wall thickness and operating requirements should be confirmed for the actual HVAC equipment and project specification before ordering.
Factory-Prepared Flared Ends with Nuts
Both copper tube ends are supplied with factory-prepared flares and nuts according to the current product information.
Before installation, inspect the flare surfaces and verify that the flare dimensions, nuts and connection method are compatible with the equipment service valves.

99.9% Pure Copper

White PE Insulated Pipe

Copper Nuts
1/2" White PE Insulation
This 30 ft 3/8" x 5/8" SKU is identified with 1/2" White PE insulation in the current product information.
The source describes the insulation system as a multilayer construction intended to provide thermal insulation and environmental protection around the copper refrigerant tubing.

White PE Three-Layer Insulation Structure
Outer Layer: Embossed PE Film
The outer layer is described as an anti-aging, UV-resistant PE film with an embossed surface designed to provide wear protection around the insulated tubing.
Middle Layer: IXPE Foam
The middle layer is identified as IXPE foam with a dense-cell structure for thermal insulation and impact absorption.
Inner Layer: Closed-Cell Insulation
The inner layer is described as a closed-cell insulation structure. The current product information lists a temperature range from -40°C to 120°C for this layer.

Insulation Pipe Production

Insulated Pipe Warehouse

Inner Insulation Layer
Insulation Test References
The current product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for insulation-related testing.
It also references ASTM C1427-07 and UL723 surface-burning characteristics in the insulation information. Buyers requiring specific test reports or classifications should confirm that the relevant documentation applies to the exact White PE configuration being ordered.
HVAC Installation Accessories
The current product information references an installation package that can include the insulated copper pipe together with communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts.
Exact package contents should be confirmed specifically for the 30 ft 3/8" x 5/8" SKU before distributor, contractor or project orders are placed.

Available White PE Insulated Copper Pipe Sizes
DABUND supplies multiple copper tube combinations, insulation thicknesses and lengths across the insulated copper pipe product range.
| Copper Tube Size | Available Lengths | White PE Insulation Options | Listed Flame Class |
|---|
| 1/4" + 3/8" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4" + 1/2" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4" + 5/8" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8" + 5/8" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8" + 3/4" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2" + 3/4" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8" + 7/8" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Note: The table above represents the wider White PE insulated copper pipe family. This page specifically covers the 30 ft 3/8" x 5/8" configuration with 1/2" White PE insulation.
3/8" x 5/8" Line Set for Compatible 36K–48K Systems
The current DABUND product information associates the 3/8" x 5/8" tubing combination with some approximately 3–4 ton or 36,000–48,000 BTU ductless air-conditioning systems.
This is a general product-family reference rather than a universal compatibility rule.
Different HVAC models with the same nominal capacity can require different liquid and suction line sizes. Always confirm the required refrigerant tubing dimensions in the equipment manufacturer's installation manual.
Important Checks for a 30 Ft Refrigerant Line
Confirm the Required Tube Sizes
Verify that the actual HVAC equipment specifically requires 3/8" and 5/8" refrigerant tubing.
Check Maximum Permitted Line Length
Confirm that the planned 30 ft piping route is within the maximum refrigerant-line length permitted by the HVAC equipment manufacturer.
Check Minimum Permitted Line Length
Some HVAC equipment also specifies a minimum refrigerant-line length. Follow the equipment manufacturer's instructions if the actual piping route is shorter.
Confirm Vertical Separation
If the indoor and outdoor units are installed at different elevations, confirm the maximum permitted vertical separation in the equipment documentation.
Check Refrigerant Charge Requirements
Check the factory refrigerant charge and the piping length included in that charge. Follow the equipment manufacturer's instructions if refrigerant adjustment is required for the installed line length.
How to Install a 30 Ft 3/8" x 5/8" Copper Line Set
Step 1: Verify Equipment Compatibility
Check the HVAC equipment model and confirm that 3/8" x 5/8" is the required refrigerant-line size.
Step 2: Plan the Piping Route
Plan the route between indoor and outdoor equipment and confirm that the selected 30 ft length complies with the equipment manufacturer's piping limits.
Step 3: Protect the White PE Insulation
Avoid crushing, cutting or excessively abrading the insulation while routing the tubing through walls, ceilings or other building structures.
Step 4: Inspect the Flared Ends
Inspect the factory-prepared flare surfaces and nuts before connecting them to compatible service valves.
Step 5: Make the Refrigerant Connections
Follow the HVAC equipment manufacturer's flare-joint connection and tightening requirements.
Step 6: Leak Test and Evacuate
Complete the required leak testing and evacuation procedures according to the equipment manufacturer's installation instructions before system operation.
Step 7: Confirm Refrigerant Charge
Confirm that the installed piping length and refrigerant charge comply with the HVAC equipment manufacturer's requirements before commissioning.
HVACR Applications
The 30 ft 3/8" x 5/8" insulated copper line set can be considered for compatible HVACR systems that specifically require this tubing combination and permit the selected piping length.
Compatible ductless mini split systems
Compatible split air-conditioning systems
Compatible heat-pump installations
HVAC equipment requiring 3/8" x 5/8" refrigerant tubing
Some compatible 36K–48K BTU applications
Medium-length indoor-to-outdoor refrigerant piping routes
Compatibility must always be verified using the exact HVAC equipment model and installation documentation.
Information to Confirm Before Ordering
HVAC distributors, wholesalers, contractors and professional buyers should confirm the following information before ordering:
Required copper tube size: 3/8" x 5/8"
Required line-set length: 30 ft
HVAC equipment model
Minimum and maximum permitted piping length
Vertical separation requirements
Required insulation material and thickness
Required package accessories
Order quantity
Packaging requirements
OEM or private-label requirements
DABUND Insulated Copper Pipe Manufacturer
DABUND has produced insulated copper pipe, mini split line sets and related HVAC installation products since 2008.
Multiple copper tube combinations, insulation configurations and piping lengths are available for HVAC distributors, wholesalers, contractors and professional buyers.
OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.
DABUND Factory
DABUND produces insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation products.

Test Documentation
The current product information references insulation test documentation including ASTM E84, UL94, ASTM D1056 and ASTM G21.
Buyers requiring a particular report or classification should confirm that the documentation applies to the exact White PE insulation and product configuration being ordered.

Exhibition
DABUND presents insulated copper pipe, mini split line sets and related HVAC installation products at industry exhibitions for international buyers.

Frequently Asked Questions
What size is this insulated copper line set?
This product uses 3/8" and 5/8" copper tubing.
How long is this insulated copper pipe?
This product is supplied in a 30 ft length.
What insulation is used on this product?
The current product information identifies this configuration with 1/2" White PE insulation.
What is the White PE insulation structure?
The current product information describes an embossed PE outer film, an IXPE middle layer and a closed-cell inner insulation layer.
What copper standards are listed?
The current product information identifies ASTM B280 and C12200 DHP references for the copper tubing.
Are the copper tube ends flared?
Yes. Both copper tube ends are described as flared and supplied with nuts.
What temperature range is listed for the inner insulation layer?
The current product information lists a temperature range of -40°C to 120°C for the closed-cell inner insulation layer.
What system capacity commonly uses 3/8" x 5/8" tubing?
The current DABUND product information associates 3/8" x 5/8" tubing with some approximately 3–4 ton or 36,000–48,000 BTU ductless air-conditioning systems. This is only a general reference.
Can this line set be used with every 36,000 or 48,000 BTU air conditioner?
No. Different HVAC models can require different refrigerant tubing sizes even when their nominal capacities are similar. Confirm the required tubing in the equipment installation manual.
Is 30 ft suitable for every installation?
No. Confirm that 30 ft falls within the minimum and maximum refrigerant-line lengths permitted by the equipment manufacturer.
Does a 30 ft line require additional refrigerant?
It depends on the HVAC equipment. Check the factory refrigerant charge, included piping-length allowance and refrigerant adjustment instructions provided by the manufacturer.
Does vertical separation matter?
Yes. Confirm the permitted elevation difference between indoor and outdoor equipment in the manufacturer's installation documentation.
Can this line set be used with a heat pump?
It can be considered for compatible heat-pump equipment that specifically requires 3/8" x 5/8" refrigerant tubing and permits the selected piping length.
What accessories can be supplied?
The current product information references communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts. Confirm the exact package contents for this SKU before ordering.
Are other copper tube sizes available?
Yes. The product family includes 1/4" x 3/8", 1/4" x 1/2", 1/4" x 5/8", 3/8" x 5/8", 3/8" x 3/4", 1/2" x 3/4" and 3/8" x 7/8" combinations.
Can DABUND provide OEM or ODM insulated copper pipe?
Yes. OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.
Can I request a sample?
Sample requests are available according to the current sales policy. View sample information.
What payment terms are available?
Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.
What trade terms are available?
Available international trade terms can include EXW, FOB, CFR and CIF.
What is the typical delivery time?
The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on order quantity, product configuration, customization and production schedule.