Home Copper Pipe Pre Insulated Copper Tubing 35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
35 Ft 1/4" X 5/8" Pre Insulated Copper Tubing
1.Insulated Copper Pipe including one set air conditioner insulated copper tube, size 1/4"+5/8" 35 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts. 
2. Both of the two copper pipe end do flaring and nuts. 
3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm. 
4. For the Insulated Copper Pipe, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m. 
5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200. 
6.Professional manufacturer of Insulated Copper Tube, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 10M

Material

99.9% pure copper

Color

Black/White

Keywords

Insulated Copper Tube

Application

HVAC
Inquire
Add to Basket

35 Ft 1/4" x 5/8" Pre-Insulated Copper Tubing

DABUND 35 Ft 1/4" x 5/8" Pre-Insulated Copper Tubing is designed for compatible HVACR and split air-conditioning systems requiring 1/4-inch and 5/8-inch refrigerant tubing.

This configuration uses 1/2" Black Rubber insulation according to the current product information. Both copper tubes are supplied with factory-prepared flared ends and nuts for compatible flare-type HVAC connections.

The copper tubing is identified with ASTM B280 and C12200 DHP references. The 35 ft length is suitable for projects where the selected HVAC equipment permits this piping length and requires the 1/4" x 5/8" tube combination.

Quick Answer: This product is a 35 ft 1/4" x 5/8" pre-insulated copper tubing set with 1/2" Black Rubber insulation, flared copper ends and nuts for compatible HVACR installations.

Selection Notice: The current DABUND product information associates 1/4" x 5/8" tubing with some approximately 2–2.5 ton or 24,000–30,000 BTU systems. This is only a general reference. Always confirm the required refrigerant tubing dimensions from the actual equipment manufacturer's installation documentation.

35 Ft 1/4" x 5/8" Pre-Insulated Copper Tubing Specifications

Product TypePre-Insulated Copper Tubing
Tube Size1/4" x 5/8"
Metric Outside DiameterApproximately 6.35 mm x 15.88 mm
Length35 ft / approximately 10.67 m
Current Insulation Configuration1/2" Black Rubber
Copper Tube ReferenceASTM B280 / C12200 DHP
Tube End PreparationFlared ends with nuts
Black Rubber Temperature Range-40°C to 120°C according to current product information
General Capacity ReferenceSome 24K–30K BTU / approximately 2–2.5 ton systems; actual equipment specification governs
Buyer TypeHVAC distributors, wholesalers, contractors and project buyers

Pre-Insulated Copper Tubing for HVACR Projects

Pre-insulated copper tubing combines refrigerant-grade copper tubing with factory-applied insulation, helping reduce the amount of insulation work required at the installation site.

This 35 ft configuration can be considered for medium-to-long indoor-to-outdoor piping routes where the selected equipment specifically requires 1/4" x 5/8" refrigerant tubing.

For project and wholesale purchasing, buyers should confirm copper tube size, total piping length, insulation type, insulation thickness, package accessories and equipment compatibility before ordering.

ASTM B280 and C12200 Copper Tubing

The copper tubing in this product range is identified with ASTM B280 and C12200 DHP references for HVACR copper tube applications.

The current product information also describes the tubing as all-copper construction and identifies the copper as 99.9% pure.

For commercial orders, required wall thickness and other dimensional requirements should be confirmed according to the exact HVAC equipment or project specification.

Factory-Prepared Flared Ends

Both copper tube ends are supplied with factory-prepared flares and nuts according to the current product information.

Installers should inspect the flare surfaces before connection and verify that the flare dimensions, nuts and connection method match the equipment service valves.

Copper tubing for 35 ft 1/4 x 5/8 pre-insulated HVAC copper tubing

Copper Tubing

Black Rubber insulated 1/4 x 5/8 copper tubing for HVACR

Black Rubber Insulation

Factory-prepared flared ends on pre-insulated copper tubing

Flared Ends

1/2" Black Rubber Insulation

This 35 ft 1/4" x 5/8" product is identified with 1/2" Black Rubber insulation in the current product information.

The insulation provides a thermal and moisture-control layer around the copper tubing and helps limit condensation on the insulated refrigerant line.

The current Black Rubber product information lists a temperature range from -40°C to 120°C.

DABUND also lists other insulation configurations across the wider product range. Buyers should confirm the required insulation material and thickness for the exact order.

Black Rubber insulation used on pre-insulated HVAC copper tubing

Black Rubber Insulation Features

Thermal Insulation

The insulation layer helps reduce heat transfer between the refrigerant tubing and the surrounding environment.

Moisture and Condensation Control

The current product information describes the Black Rubber insulation as functioning as both the insulation layer and moisture-proof layer.

Temperature Range

The listed Black Rubber insulation temperature range is -40°C to 120°C.

Insulation Test References

The current product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for insulation-related testing. Buyers requiring a particular test report or classification should confirm which documentation applies to the exact insulation configuration being ordered.

HVAC Installation Accessories

The current product information references an HVAC installation package that can include pre-insulated copper tubing together with communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts.

Exact package contents should be confirmed specifically for the 35 ft 1/4" x 5/8" product before placing distributor, contractor or project orders.

35 ft 1/4 x 5/8 pre-insulated copper tubing with HVAC installation accessories

Pre-Insulated Copper Tubing Size Options

The wider DABUND product range includes multiple copper tube combinations, insulation thicknesses and tubing lengths for different HVACR projects.

Copper Tube SizeAvailable LengthsBlack Rubber Insulation OptionsListed Flame Class
1/4" + 3/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4" + 1/2"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4" + 5/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 5/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 3/4"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2" + 3/4"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 7/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

Note: The table above represents the wider product family. This page specifically covers the 35 ft 1/4" x 5/8" configuration with 1/2" Black Rubber insulation.

1/4" x 5/8" Tubing for Compatible 24K–30K Systems

The current DABUND product information associates 1/4" x 5/8" tubing with some approximately 2–2.5 ton or 24,000–30,000 BTU split air-conditioning systems.

This should be treated only as a general product-family reference.

Different HVAC equipment with the same nominal capacity can use different refrigerant tube sizes. Always confirm the required liquid and suction line dimensions in the equipment manufacturer's installation documentation.

Selecting 35 Ft Pre-Insulated Copper Tubing

Confirm the Required Copper Tube Size

Verify that the actual HVAC equipment requires 1/4" and 5/8" refrigerant tubing.

Confirm the Required Piping Length

Measure the planned indoor-to-outdoor piping route and confirm that 35 ft is appropriate for the installation.

Check Maximum and Minimum Line Length

Confirm that the planned piping length remains within the minimum and maximum refrigerant-line limits specified by the equipment manufacturer.

Check Vertical Separation

If the indoor and outdoor equipment are installed at different elevations, confirm the permitted vertical separation.

Confirm Refrigerant Charge Requirements

Check the factory refrigerant charge and the piping length included in that charge. Follow the manufacturer's instructions if refrigerant adjustment is required.

Installation Considerations

Inspect the Tubing Before Installation

Inspect the copper tubing and insulation before routing and avoid crushing the tube, creating sharp bends or damaging the insulation layer.

Inspect the Flared Connections

Check the factory-prepared flare surfaces and nuts before connecting the tubing to compatible service valves.

Follow Equipment Tightening Requirements

Follow the HVAC equipment manufacturer's specified flare-joint connection and tightening procedure.

Leak Test and Evacuate the System

Complete the required leak testing and evacuation procedures according to the equipment manufacturer's instructions before system operation.

Confirm Refrigerant Charge Before Commissioning

Verify that the installed piping length and refrigerant charge comply with the equipment manufacturer's requirements before commissioning.

Applications

This 35 ft 1/4" x 5/8" pre-insulated copper tubing can be considered for compatible HVACR systems requiring this tube combination.

  • Compatible ductless mini split installations

  • Compatible split air-conditioning systems

  • Compatible heat-pump projects

  • HVAC replacement projects requiring 1/4" x 5/8" tubing

  • Some compatible 24K–30K BTU systems

  • Distributor and contractor stock programs

  • Commercial HVAC project purchasing

Compatibility should always be verified using the exact HVAC equipment model and manufacturer documentation.

Information to Confirm Before Ordering

Distributors, wholesalers, contractors and project buyers should confirm the following information before placing an order:

  • Copper tube size: 1/4" x 5/8"

  • Required tubing length: 35 ft

  • HVAC equipment model

  • Required insulation material

  • Required insulation thickness

  • Required package accessories

  • Order quantity

  • Packaging requirements

  • OEM or private-label requirements

Pre-Insulated Copper Tubing for Distributors and Contractors

DABUND supplies pre-insulated copper tubing and related HVAC installation products for distributors, wholesalers, contractors and project buyers.

Different copper tube combinations, insulation configurations and lengths are available across the product range.

OEM and ODM requirements can be discussed according to tubing dimensions, insulation configuration, packaging and commercial purchasing requirements.

DABUND Manufacturer Since 2008

DABUND has produced insulated copper pipe, pre-insulated copper tubing, mini split line sets and related HVAC installation products since 2008.

DABUND factory production and packaging of pre-insulated copper tubing

Insulation Test References

The current product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for insulation-related testing.

Because different insulation configurations are available, buyers requiring a particular test report or classification should confirm that the applicable documentation matches the exact product configuration being ordered.

Test certificate for DABUND pre-insulated copper tubing insulation

Exhibition

DABUND presents insulated copper tubing, line sets and related HVAC installation products at industry exhibitions for international buyers.

DABUND pre-insulated copper tubing displayed at HVAC industry exhibitions

Frequently Asked Questions

What size is this pre-insulated copper tubing?

This product uses 1/4" and 5/8" copper tubing.

How long is this pre-insulated copper tubing?

This product is supplied in a 35 ft length.

What insulation is used on this product?

The current product information identifies this configuration with 1/2" Black Rubber insulation.

What copper standards are listed?

The current product information identifies ASTM B280 and C12200 DHP references for the copper tubing.

Are the copper tubing ends flared?

Yes. Both copper tube ends are described as flared and supplied with nuts.

What is the Black Rubber insulation temperature range?

The current product information lists a Black Rubber insulation temperature range from -40°C to 120°C.

What system capacity commonly uses 1/4" x 5/8" tubing?

The current DABUND product information associates 1/4" x 5/8" tubing with some approximately 2–2.5 ton or 24,000–30,000 BTU split air-conditioning systems. This is only a general reference.

Can this tubing be used with every 24,000 or 30,000 BTU air conditioner?

No. HVAC equipment with similar nominal capacities can require different refrigerant tube sizes. Confirm the required tubing in the equipment installation manual.

Is 35 ft suitable for every installation?

No. Confirm that the selected piping length falls within the minimum and maximum refrigerant-line lengths permitted by the equipment manufacturer.

Does a 35 ft installation require additional refrigerant?

It depends on the HVAC equipment. Check the factory refrigerant charge, included piping-length allowance and refrigerant adjustment instructions provided by the manufacturer.

Does vertical separation matter?

Yes. Confirm the permitted elevation difference between indoor and outdoor equipment in the manufacturer's installation documentation.

Can this pre-insulated copper tubing be used with heat pumps?

It can be considered for compatible heat-pump equipment that specifically requires 1/4" x 5/8" refrigerant tubing and permits the selected piping length.

Can this tubing be used for VRF systems?

Only where the applicable VRF piping design specifically requires this tube combination and permits the selected piping configuration.

What accessories can be supplied?

The current product information references communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts. Confirm the exact package contents for the 35 ft 1/4" x 5/8" configuration before ordering.

Are other copper tubing sizes available?

Yes. The current product range includes 1/4" x 3/8", 1/4" x 1/2", 1/4" x 5/8", 3/8" x 5/8", 3/8" x 3/4", 1/2" x 3/4" and 3/8" x 7/8" combinations.

Can DABUND provide OEM or ODM pre-insulated copper tubing?

Yes. OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.

Can I request a sample?

Sample requests are available according to the current sales policy. View sample information.

What payment terms are available?

Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.

What international trade terms are available?

Available trade terms can include EXW, FOB, CFR and CIF.

What is the typical delivery time?

The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on order quantity, product configuration, customization and production schedule.

Related Products

1. 3/8" x 7/8" x 50 ft is the out dimension in inch. 9.52mm - 22.22mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.