50 ft 1/4 in. x 3/8 in. Mini Split Copper Line Set
DABUND 50 ft 1/4 in. x 3/8 in. Copper Line Set is designed for compatible mini split air conditioners, ductless HVAC systems, heat pumps and residential or light commercial refrigerant piping installations.
The paired refrigerant tubing includes a 1/4 in. liquid line and 3/8 in. suction line with a continuous 50 ft length, approximately 15.24 m.
The tubing is manufactured from 99.9% pure copper and supplied with factory-applied insulation to help reduce heat transfer, control condensation and simplify HVAC installation.
Quick Answer: This 50 ft 1/4 x 3/8 mini split line set provides pre-insulated copper liquid and suction lines for compatible HVAC systems requiring these specific refrigerant tube sizes.
50 ft 1/4 x 3/8 Copper Line Set Specifications
| Product Type | Pre-Insulated Mini Split Copper Line Set |
| Line Set Size | 1/4 in. x 3/8 in. |
| Liquid Line | 1/4 in. / 6.35 mm |
| Suction Line | 3/8 in. / 9.52 mm |
| Length | 50 ft / 15.24 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standards | ASTM B280 / C12200 |
| Insulation | Factory-Applied, UV-Resistant |
| Featured Insulation | White PE Configuration Shown |
| Listed Temperature Range | -40°C to 120°C for applicable insulation configuration |
| Source Pressure Reference | 2100–7000 PSI source reference range; confirm exact working and burst pressure for the selected tube configuration |
| Applications | Compatible mini split, heat pump and ductless HVAC systems |
| Listed Refrigerants | R410A, R32 and other compatible HVAC refrigerants |
50 ft Mini Split Copper Line Set Video
1/4 in. Liquid Line and 3/8 in. Suction Line
The refrigerant line set combines a 1/4 in. liquid line for refrigerant delivery with a 3/8 in. suction line for refrigerant vapor return.
Both tube dimensions must match the HVAC equipment manufacturer's specified liquid-line and suction-line sizes. Compatibility should not be determined by nominal system capacity alone.
50 ft Continuous Length for Flexible Installation
The 50 ft continuous refrigerant line provides additional routing flexibility where indoor and outdoor mini split equipment are separated by a moderate distance.
A continuous coil can reduce the need for intermediate tubing extensions or additional refrigerant-line connections compared with joining several shorter sections.
Before installation, confirm that the total 50 ft piping length is within the HVAC manufacturer's maximum permitted line length and elevation requirements.
99.9% Pure Copper Refrigerant Tubing
The refrigerant tubing is manufactured from 99.9% pure copper and references ASTM B280 and C12200.
Copper provides the thermal conductivity, corrosion resistance and flexibility required for compatible professional HVAC refrigerant piping installations.
Factory-Applied Pipe Insulation
Factory-applied insulation helps reduce unwanted heat gain and heat loss along the refrigerant piping while helping control condensation on cold tubing surfaces.
Pre-insulated construction also reduces additional field insulation work and provides more consistent coverage around the refrigerant tubing.
The current product images show a White PE insulated configuration. Insulation material and corresponding test documentation should be confirmed for the exact product configuration before bulk ordering.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Protective Plastic Cap
White PE Insulation
The featured product configuration uses White PE insulation around the copper refrigerant tubing.
The insulation helps reduce thermal exchange and surface condensation while adding physical protection around the copper line set.

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Insulation Layer
Benefits of This Mini Split Copper Line Set
Reduced Field Insulation Work
Factory insulation reduces the amount of on-site insulation wrapping required and provides more consistent coverage along the refrigerant line.
Condensation Control
Proper insulation helps reduce condensation on cold refrigerant piping and limits moisture exposure to surrounding walls, ceilings and building surfaces.
Thermal Protection
Insulation helps limit unwanted thermal exchange between the refrigerant tubing and surrounding environment during HVAC operation.
Continuous 50 ft Refrigerant Run
A continuous 50 ft coil provides flexible routing for compatible projects and can reduce the need for intermediate refrigerant-line connections.
50 ft White PE Insulated Copper Line Set
The featured White PE configuration combines factory-insulated copper tubing with a continuous 50 ft line set for compatible mini split and HVAC installations.

Available Copper Line Set Sizes
The following table shows the size, production-length and White PE insulation options listed for the wider DABUND copper line set family.
| Line Set Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
General Line Set Size and Capacity Reference
The following capacity ranges are general references from the wider DABUND line set family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact liquid-line and suction-line requirements.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000 / 12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000 / 18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000 / 30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000 / 48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000 / 72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
For the 1/4 x 3/8 configuration, the DABUND product family lists 0.75–1.0 ton and 9,000–12,000 BTU as general references. Always verify the actual refrigerant-line dimensions required by the equipment manufacturer.
Compatible HVAC Applications
Compatible ductless mini split air conditioners
Compatible heat-pump systems
Residential HVAC installations
Apartment air-conditioning projects
Office and light commercial HVAC installations
Compatible refrigerant line replacement projects
Refrigerant Compatibility
The source product information lists R410A and R32 among the common refrigerants used with compatible HVAC installations.
Final refrigerant compatibility, required tube size, allowable working pressure and connection requirements must be verified against the specific HVAC equipment manufacturer's technical specifications.
Important Considerations for a 50 ft Line Set
Verify the Maximum Permitted Line Length
Confirm that the HVAC equipment manufacturer permits at least 50 ft of total refrigerant piping.
Check Maximum Elevation Difference
If the indoor and outdoor units are installed at different elevations, confirm the permitted vertical separation specified by the equipment manufacturer.
Check Additional Refrigerant Charge
Depending on the equipment and installed line length, additional refrigerant may be required. Follow the HVAC manufacturer's charging instructions.
Confirm the Exact Tube Sizes
Confirm that the equipment specifically requires a 1/4 in. liquid line and 3/8 in. suction line before ordering.
Installation Guidelines
Measure the Complete Refrigerant Line Route
Measure the full distance between indoor and outdoor equipment before installation to confirm that the 50 ft line set provides suitable routing length.
Avoid Sharp Bends and Kinks
Route the copper tubing using appropriate bend radii to reduce the risk of kinking or restricting the refrigerant line.
Protect Insulation at Wall Penetrations
Use suitable wall sleeves or protective grommets where the insulated tubing passes through walls or structural openings to reduce insulation damage.
Support Long Refrigerant Runs
Use suitable HVAC line clamps, straps or support brackets along the piping route to reduce sagging, vibration and insulation compression.
Follow the Equipment Manufacturer's Instructions
Refrigerant piping, connection preparation, evacuation, charging and commissioning should follow the HVAC equipment manufacturer's installation requirements.
DABUND Mini Split Line Set Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation products for distributors and project customers.

Insulation Test Documentation
The source product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable insulation configurations.
The certificate section refers to Polypropylene or Black Rubber insulation, while this product's main images show White PE. Buyers requiring specific certification should therefore confirm the selected insulation material and corresponding test documentation before ordering.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where distributors and professional buyers can review mini split line sets, insulated copper tubing and related HVAC products.

Frequently Asked Questions
What does 1/4 in. x 3/8 in. mean?
It refers to the listed outside diameters of the two refrigerant tubes: 1/4 in. for the liquid line and 3/8 in. for the suction line.
How long is this mini split line set?
The line set is 50 ft long, equivalent to approximately 15.24 m.
What material is the refrigerant tubing made from?
The source product information lists 99.9% pure copper tubing.
What standards are referenced for the copper tubing?
ASTM B280 and C12200 are referenced in the product information.
Is this copper line set pre-insulated?
Yes. The copper refrigerant tubing is supplied with factory-applied insulation.
What insulation configuration is shown on this product?
The featured product images show a White PE insulated configuration.
What insulation thicknesses are available?
The wider product family lists White PE insulation thicknesses of 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.
What is the listed insulation temperature range?
The source technical table lists a temperature range of -40°C to 120°C. Confirm that this rating applies to the selected insulation configuration before ordering.
What size HVAC system can use a 1/4 x 3/8 line set?
The DABUND product family lists 1/4 x 3/8 as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU systems. Final line-set sizing must follow the equipment manufacturer's required refrigerant-line dimensions.
Can every mini split use this 50 ft line set?
No. Confirm the required liquid-line size, suction-line size, maximum piping length, allowable elevation difference and connection requirements for the specific HVAC equipment.
Does a 50 ft line set require additional refrigerant?
Additional refrigerant may be required depending on the HVAC equipment and total installed refrigerant piping length. Follow the equipment manufacturer's charging instructions.
Is this line set compatible with R410A and R32?
The source product information lists R410A and R32 among the compatible refrigerants. Final suitability should be verified against the HVAC equipment manufacturer's technical specifications.
Can this line set be used outdoors?
The source product information describes the insulation as UV-resistant for compatible indoor and outdoor refrigerant-line installations.
Is additional field insulation required?
Factory-applied insulation reduces additional field wrapping, although local codes and specific installation conditions may require additional protection.
What is the pressure rating?
The source page lists a broad 2100–7000 PSI range. Because actual pressure ratings depend on tube diameter, wall thickness and test method, confirm the working pressure and burst pressure for the exact 1/4 x 3/8 configuration before ordering.
What other copper line set sizes are available?
Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
What production lengths are available?
The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths.
Can DABUND provide free samples?
Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer paying the express freight. View Sample Information
What payment terms are available?
Available payment methods include T/T, L/C at sight and credit card.
What delivery terms are available?
Available delivery terms include EXW, FOB, CFR and CIF.
Does DABUND support OEM and ODM?
Yes. OEM and ODM services, including logo customization, are available for suitable orders.
What is the typical delivery time?
The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.