50 ft 3/8 in. x 3/4 in. Split AC Installation Kit
The DABUND 50 ft 3/8 in. x 3/4 in. Split AC Installation Kit is a complete HVAC copper line set solution for compatible split air conditioners, ductless mini split systems, heat pumps and refrigeration installations.
The kit combines a 50 ft pre-insulated copper refrigerant line set with communication wire, condensate drain hose, wall sleeve, decorative cover, pre-flared copper ends with nuts and related installation fittings.
The refrigerant piping uses a 3/8 in. line and a 3/4 in. line made from 99.9% pure C12200 copper. ASTM B280 is referenced according to product specification, while Black Rubber is the primary insulation configuration shown on this page.
Quick Answer: This 50 ft 3/8 x 3/4 complete HVAC installation kit is generally referenced for compatible 4.5–6 ton / 54,000–72,000 BTU systems. Final compatibility must follow the equipment manufacturer's required pipe sizes, refrigerant type, maximum piping length and charging requirements.
Split AC Installation Kit Video
What Is Included in the 50 ft Installation Kit?
| Insulated Copper Line Set | 3/8 in. + 3/4 in., 50 ft / 15.24 m |
| 3/8 in. Copper Line | 9.52 mm outside diameter |
| 3/4 in. Copper Line | 19.05 mm outside diameter |
| Communication / Control Wire | Included according to kit configuration |
| Condensate Drain Hose | Approximately 3 m according to kit configuration |
| Wall Sleeve | Included |
| Decorative Wall Cover | Included |
| Pre-Flared Ends | Both copper pipe ends are pre-flared according to the source configuration |
| Flare Nuts and Fittings | Included |
Communication-wire specification, drain-hose dimensions, wall-sleeve dimensions and exact accessory quantities should be confirmed for the ordered kit configuration.
3/8 x 3/4 Copper Refrigerant Line Set
This installation kit combines 3/8 in. and 3/4 in. copper refrigerant tubing for compatible HVAC equipment requiring these exact line sizes.
The source page describes the 3/8 in. line as the liquid line and the 3/4 in. line as the suction line for this configuration. Final piping arrangement should always follow the HVAC equipment manufacturer's documentation.
General 4.5–6 Ton / 54,000–72,000 BTU Reference
The wider DABUND product-family table lists the 3/8 in. + 3/4 in. configuration as a general reference for some 4.5–6 ton HVAC systems.
The corresponding family reference is approximately 54,000–72,000 BTU.
These capacity values are general references only. Final pipe-size selection must follow the equipment manufacturer's required liquid-line and suction-line dimensions.
99.9% Pure C12200 Copper Tubing
The source product information specifies 99.9% pure C12200 copper for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC and refrigeration applications.
ASTM B280 Copper Tubing
ASTM B280 and C12200 are referenced according to product specification. Buyers requiring project documentation should confirm the exact tube dimensions, wall thickness and matching technical documentation for the ordered configuration.
Pressure Capability for R410A and R32 Applications
The source page lists a pressure range of approximately 2100–7000 PSI according to specification and references R410A and R32 refrigerant applications.
This range should not be treated as a universal working-pressure rating for every copper tube configuration. Actual allowable pressure depends on tube diameter, wall thickness, operating temperature and exact product specification.
Pre-Flared Copper Ends with Nuts
The source page states that both copper pipe ends are pre-flared and supplied with nuts.
Pre-flared connections can reduce field preparation work when the flare dimensions and supplied nuts match the selected HVAC equipment.
Installers should inspect every flare before connection and tighten the flare nuts according to the equipment manufacturer's specified torque.
Copper Line Set and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Pre-Flared Copper End
Black Rubber Pipe Insulation
Black Rubber is the primary insulation configuration shown on this page and in the wider installation-kit family table.
The source describes Black Rubber insulation as providing both thermal insulation and moisture-resistant functions in one structure.
Condensation Protection
Closed-cell insulation helps reduce moisture penetration and surface condensation around cold refrigerant piping.
Listed Temperature Range
The source page lists a temperature range from approximately -40°C to 120°C for applicable Black Rubber insulation configurations.
UV-Resistant Configurations
UV-resistant insulation configurations are referenced for compatible outdoor installations. Final suitability depends on the exact material, thickness and environmental exposure conditions.

Multi-Layer Insulation Structure
Outer Protective Layer
The source references a UV-resistant protective outer layer for applicable insulation configurations.
High-Density Foam Layer
A high-density foam layer provides thermal insulation around the copper refrigerant line.
Closed-Cell Moisture Barrier
The closed-cell inner structure helps limit water-vapor penetration and surface condensation.
Complete Split AC Accessory Package
This SKU is configured as a complete split-system installation kit rather than only a copper line set.
50 ft 3/8 in. + 3/4 in. insulated copper line set
Communication / control wire
Drain hose, approximately 3 m according to kit configuration
Wall pipe sleeve
Decorative wall cover
Flare nuts
Installation fittings

HVAC Applications
Compatible residential split air-conditioning systems
Ductless mini split systems
Heat-pump systems
Offices and retail HVAC installations
Light commercial HVAC projects
Compatible refrigeration installations
HVAC replacement and upgrade projects
Technical Specifications
| Specification | Detail |
|---|
| Product Name | 50 ft 3/8 in. x 3/4 in. Split AC Installation Kit |
| Product Type | Complete HVAC Copper Line Set Solution |
| Copper Line Size | 3/8 in. + 3/4 in. / 9.52 mm + 19.05 mm |
| Length | 50 ft / 15.24 m |
| Material | 99.9% Pure Copper / C12200 |
| Copper Standard | ASTM B280 / C12200 according to product specification |
| Source-Listed Pressure Range | 2100–7000 PSI according to specification |
| Listed Temperature Range | -40°C to 120°C |
| Insulation | PE / Rubber Foam according to selected specification |
| Pre-Flared Ends | Included with nuts according to source kit configuration |
| Included Accessories | Communication Wire, Drain Hose, Wall Sleeve, Decorative Cover, Flare Nuts and Fittings |
| General Capacity Reference | 4.5–6.0 Ton / 54,000–72,000 BTU |
| Applications | Compatible Split AC / Mini Split / Heat Pump / HVAC / Refrigeration Systems |
Split AC Installation Kit Size Options
| Size | Standard Family Lengths | Black Rubber Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 50 ft / 15.24 m. The wider family table lists standard metric lengths up to 10 m, so buyers should specify the exact 50 ft finished kit configuration when ordering.
Line Set Size and HVAC Capacity Reference
| Line Set Size | General Ton / HP Range | General BTU Range | Typical Application |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton / 0.75P–1P | 9,000–12,000 BTU | Small Mini Split AC |
| 1/4 + 1/2 in. | 1.5–2.0 Ton / 1.5P–2P | 12,000–18,000 BTU | Medium Mini Split AC |
| 1/4 + 5/8 in. | 2.0–2.5 Ton / 2P–2.5P | 24,000–30,000 BTU | Split AC / Heat Pump |
| 3/8 + 5/8 in. | 3.0–4.0 Ton / 3P–4P | 36,000–48,000 BTU | Ductless Commercial AC |
| 3/8 + 3/4 in. | 4.5–6.0 Ton / 4.5P–6P | 54,000–72,000 BTU | Large Split AC |
| 3/8 + 7/8 in. | 6.0–8.0 Ton / 6P–8P | 72,000–96,000 BTU | High-Capacity Ductless HVAC |
These capacity values are general product-family references only. Final line-set sizing must follow the HVAC equipment manufacturer's exact piping requirements.
Important Checks for a 50 ft Refrigerant Run
Confirm Exact Pipe Sizes
Verify that the selected equipment specifically requires a 3/8 in. and 3/4 in. refrigerant-line combination.
Verify Maximum Permitted Piping Length
Confirm that the HVAC equipment manufacturer permits the proposed 50 ft refrigerant piping route.
Check Minimum Permitted Piping Length
Some HVAC equipment also specifies a minimum refrigerant piping length. Confirm both minimum and maximum limits before installation.
Check Maximum Elevation Difference
If indoor and outdoor units are installed at different elevations, verify the manufacturer's maximum permitted vertical separation.
Check Additional Refrigerant Charge
A 50 ft refrigerant run may require additional refrigerant depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions.
Confirm Communication Wire Specification
Communication wire is included according to the source page. Confirm conductor count, wire gauge, voltage rating and compatibility with the selected equipment.
Plan the Condensate Drain Route
Route the approximately 3 m drain hose with suitable slope and follow the indoor-unit manufacturer's condensate-drainage requirements.
Installation Guidelines
Plan the Installation Route
Measure the complete route before uncoiling, cutting or modifying the copper line set.
Maintain Proper Bend Radius
Use appropriate HVAC tube-bending methods and suitable bend radii to reduce the risk of kinking or flattening the copper tubing.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and wall penetrations.
Inspect Pre-Flared Connections
Inspect the factory flare surfaces before connection and tighten the supplied nuts according to the HVAC equipment manufacturer's specified torque.
Keep Copper Ends Clean
Keep open refrigerant-line ends protected from dust, moisture and contamination before final connection.
Pressure Test and Evacuate Before Startup
Refrigerant piping should be leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.
OEM and Custom Split AC Installation Kits
Custom line-set lengths
Custom copper pipe-size combinations
Custom insulation thickness
Black Rubber or PE insulation options
Custom insulation colors
Logo and pipe-marking printing
Private-label packaging
Custom accessory combinations
OEM and ODM supply for distributors and HVAC brands
DABUND HVAC Installation Kit Factory
DABUND manufactures split AC installation kits, mini split line sets, insulated copper pipes, aluminum pipes and related HVAC components for distributors, contractors, wholesalers and OEM customers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations can meet ASTM E84, UL94, ASTM D1056 and ASTM G21 requirements according to product specification.
Black Rubber is the primary insulation configuration shown on this page, so the certificate description is more closely aligned with the featured product configuration. Buyers should still confirm the exact insulation material, thickness and matching test report for the ordered kit.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review mini split line sets, split AC installation kits, insulated copper pipes and related HVAC products.

Frequently Asked Questions
What is included in this 50 ft split AC installation kit?
The source kit includes a 50 ft 3/8 x 3/4 insulated copper line set, communication wire, approximately 3 m drain hose, wall sleeve, decorative cover, pre-flared ends with nuts and installation fittings.
What does 3/8 x 3/4 mean?
It refers to the outside diameters of the paired copper refrigerant tubes. The source page identifies the 3/8 in. line as the liquid line and the 3/4 in. line as the suction line for this configuration.
What HVAC capacity commonly uses a 3/8 x 3/4 line set?
The wider DABUND product family lists 3/8 x 3/4 as a general reference for some 4.5–6 ton or 54,000–72,000 BTU systems. Final pipe sizing must follow the equipment manufacturer's exact requirements.
How long is the copper line set?
This SKU is 50 ft long, equal to 15.24 m.
Are the copper pipe ends pre-flared?
Yes. The source page states that both copper pipe ends are pre-flared and supplied with nuts.
What copper material is used?
The source page specifies 99.9% pure C12200 copper and references ASTM B280 according to product specification.
What insulation is used?
Black Rubber is the primary configuration shown on the page. PE and Rubber Foam insulation options are listed according to selected specification.
What insulation thicknesses are available?
The wider Black Rubber product-family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
What is the listed temperature range?
The source page lists approximately -40°C to 120°C for applicable insulation configurations.
What is the pressure rating?
The source page lists a 2100–7000 PSI range according to specification. Actual allowable working pressure depends on tube diameter, wall thickness, temperature and exact product configuration.
Can this kit be used with R410A or R32?
R410A and R32 are referenced on the source page. Final compatibility depends on copper dimensions, wall thickness, allowable pressure, piping length and HVAC equipment requirements.
Does the kit include communication wire?
Yes. Communication or control wire is included according to the source kit configuration. Confirm the exact conductor and electrical specification for the ordered kit.
Does the kit include a drain hose?
Yes. The source page lists a drain hose of approximately 3 m according to kit configuration.
Is 50 ft suitable for every HVAC system?
No. Confirm the equipment manufacturer's minimum and maximum permitted piping lengths, elevation difference and refrigerant-charge requirements before installation.
Does a 50 ft line require additional refrigerant?
It may. Additional refrigerant depends on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions.
Can this installation kit be used outdoors?
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation material and environmental exposure conditions.
Can DABUND customize the installation kit?
Yes. DABUND supports logo printing, custom insulation colors, custom pipe sizes and lengths, private-label packaging and OEM / ODM configurations.
Is DABUND a manufacturer?
Yes. The source page identifies DABUND as a manufacturer of split AC installation kits, mini split line sets, insulated copper pipes, aluminum pipes and HVAC parts.
Are samples available before bulk ordering?
The source page states that three free samples may be available, with the buyer generally covering express shipping costs. See the free sample page for details.
What payment terms are available?
The source page lists T/T, L/C at sight and credit card among available payment methods, subject to order details.
What delivery terms are available?
EXW, FOB, CFR and CIF are listed among available international delivery terms.
What is the typical delivery time?
The source page lists a normal delivery time of approximately 15–20 days, subject to order quantity, customization requirements and production capacity.
Is professional HVAC installation recommended?
Yes. Refrigerant piping, wiring, condensate drainage, flare connections, leak testing, evacuation, charging and commissioning should follow the HVAC equipment manufacturer's instructions and applicable local requirements.