10 ft 3/8 in. x 3/4 in. Split System AC Installation Kit
The DABUND 10 ft 3/8 in. x 3/4 in. Split System Air Conditioner Installation Kit combines insulated copper refrigerant tubing with essential installation accessories for compatible split AC systems, ductless mini split air conditioners, heat pumps and HVACR projects.
The kit includes paired 3/8 in. and 3/4 in. insulated copper tubing, communication wire cable, a 3 m condensate drain hose, wall pipe, wall cover and related installation parts.
White PE and Black Rubber insulation options are available. The copper tubing is specified to ASTM B280 using C12200 DHP copper for compatible HVAC refrigerant piping applications.
Quick Answer: The 3/8 x 3/4 line-set family is generally referenced for compatible 4.5–6.0 ton / 54,000–72,000 BTU split air-conditioning systems. Final pipe size, permitted line length, elevation difference and refrigerant-charge requirements must follow the HVAC equipment manufacturer's installation manual.
Split System AC Installation Kit Video
What Is a Split System Air Conditioner Installation Kit?
A split system air conditioner installation kit combines refrigerant tubing and installation accessories used to connect compatible indoor and outdoor HVAC equipment.
Instead of purchasing the copper line set, condensate drain hose, communication cable and wall-entry accessories separately, the kit provides the main installation components in one coordinated package.
The 10 ft configuration is suitable for compact HVAC layouts where the indoor and outdoor equipment are installed relatively close together and the equipment manufacturer permits the piping length.
Key Features
10 ft split system air conditioner installation kit
Paired 3/8 in. + 3/4 in. insulated copper tubing
Communication wire cable included
3 m condensate drain hose included
Wall pipe and wall cover included
White PE and Black Rubber insulation options
Flared-end and nut configuration available
ASTM B280 / C12200 DHP copper tubing
Multiple insulation thickness options available
Suitable for compatible split AC, mini split and heat-pump systems
OEM, ODM, logo printing and custom packaging available
What Is Included in the 10 ft Installation Kit?
| Component | Description |
|---|
| 3/8 in. Copper Pipe | Refrigerant line for compatible split AC and mini split systems. |
| 3/4 in. Copper Pipe | Larger refrigerant line used for compatible higher-capacity split AC systems. |
| Pipe Insulation | White PE or Black Rubber insulation for thermal protection and condensation control. |
| Communication Wire Cable | Used for compatible indoor-to-outdoor unit communication. Confirm conductor count, wire gauge and electrical rating before installation. |
| Drain Hose | 3 m condensate drain hose for indoor-unit drainage. |
| Wall Pipe and Cover | Protects the wall penetration and improves the finished installation appearance. |
| Flaring and Nuts | Copper tube ends can be supplied flared with nuts for compatible field connection. |
3/8 in. x 3/4 in. Refrigerant Line Set
This installation kit uses paired 3/8 in. and 3/4 in. copper refrigerant tubing.
Refrigerant-line functions and required pipe diameters vary by HVAC model. Confirm the function of each tube and the required dimensions directly from the equipment manufacturer's installation manual.
General 54,000–72,000 BTU Capacity Reference
The 3/8 in. + 3/4 in. line-set family is generally referenced for some 4.5–6.0 ton split air-conditioning systems.
The corresponding general capacity range is approximately 54,000–72,000 BTU.
These values are general references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact tubing requirements.
Copper Tube and Insulation Standards
ASTM B280 Copper Tube
The copper tubing is specified to ASTM B280 for compatible air-conditioning and refrigeration piping applications.
C12200 DHP Copper
C12200 DHP copper is used for compatible refrigerant-line configurations.
Insulation Options
High-density closed-cell polyethylene foam and Black Rubber insulation configurations are available to provide thermal coverage and help control surface condensation.
Copper Line Set and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Flared-End Configuration Available
White PE and Black Rubber Insulation Options
White PE Insulation
White PE insulation is available for compatible split AC installation-kit configurations and provides factory-applied thermal coverage around the copper tubing.
Black Rubber Insulation
Black Rubber insulation uses a closed-cell structure designed to provide thermal insulation, moisture resistance and condensation control for HVAC refrigerant tubing.
Black Rubber insulation is specified for a temperature range from approximately -40°C to 120°C.
Moisture Control
Closed-cell insulation helps reduce moisture penetration and surface condensation around cold refrigerant tubing when correctly installed and sealed.
Multiple Thickness Options
White PE and Black Rubber insulation are available in multiple thicknesses for different HVAC installation and project requirements.

Complete Split AC Installation Kit
This product combines insulated refrigerant tubing with installation accessories rather than supplying only the copper line set.
Communication wire, a 3 m condensate drain hose, wall pipe, wall cover and other necessary parts help reduce the number of separate accessories required for compatible split-system installations.

Product Specifications
| Item | Specification |
|---|
| Product Name | 10 ft 3/8 in. x 3/4 in. Split System Air Conditioner Installation Kit |
| Line Size | 3/8 in. + 3/4 in. |
| Length | 10 ft |
| Copper Tube Standard | ASTM B280 / C12200 DHP |
| Insulation Options | White PE / Black Rubber |
| Included Accessories | Drain Hose / Wire Cable / Wall Pipe / Wall Cover / Necessary Installation Parts |
| Application | Split AC / Mini Split / Heat Pump / HVACR Installation |
| Customization | OEM / ODM / Logo Printing / Custom Packaging |
Important Checks Before Installation
Confirm the Required 3/8 x 3/4 Tube Sizes
Verify that the selected HVAC equipment specifically requires 3/8 in. and 3/4 in. refrigerant tubing.
Confirm the Function of Each Tube
Confirm the liquid, suction or other refrigerant-line functions directly from the HVAC equipment manufacturer's piping diagram.
Verify the 10 ft Piping Length
Measure the complete indoor-to-outdoor route and confirm that the 10 ft supply length is appropriate for the installation.
Check Minimum and Maximum Piping Length
Some HVAC systems specify both minimum and maximum refrigerant piping lengths. Confirm that the installed route remains within the equipment manufacturer's limits.
Check Maximum Elevation Difference
Verify the permitted vertical separation between indoor and outdoor equipment.
Check Refrigerant Charge Requirements
Confirm whether the equipment's factory refrigerant charge is suitable for the actual installed piping length.
Confirm Communication Wire Compatibility
Confirm conductor count, wire gauge, voltage rating and terminal compatibility before connecting the supplied communication cable.
Maintain Drain Hose Slope
Route the 3 m condensate drain hose with the required downward slope and avoid kinks, traps or upward sections that may restrict drainage.
Installation Guidelines
Confirm the required refrigerant tubing dimensions before installation.
Measure the complete indoor-to-outdoor piping route.
Route the copper tubing without sharp bends, flattening or kinking.
Maintain continuous insulation coverage around the refrigerant lines.
Use the wall pipe and wall cover at the building penetration where appropriate.
Maintain the required downward slope for the condensate drain hose.
Verify communication-wire specifications before electrical connection.
Inspect the flare surface when a flared-end configuration is supplied.
Use the HVAC equipment manufacturer's specified flare-nut torque.
Pressure-test and leak-test the completed refrigerant circuit.
Evacuate, charge and commission the system according to the HVAC equipment manufacturer's instructions.
Split System Air Conditioner Installation Kit Size Options
| Size | Length | Insulation Black Rubber | Flame Resistant |
|---|
| 1/4 + 3/8 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 1/2 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 5/8 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 5/8 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 3/4 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/2 + 3/4 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 7/8 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
Recommended Applications by AC Capacity
| Line Set Size | Common AC Capacity | Typical BTU Range | Typical Application |
|---|
| 1/4 + 3/8 | 0.75 ton - 1.0 ton | 9,000 BTU - 12,000 BTU | Small split AC and mini split system |
| 1/4 + 1/2 | 1.5 ton - 2.0 ton | 12,000 BTU - 18,000 BTU | Residential mini split air conditioner |
| 1/4 + 5/8 | 2.0 ton - 2.5 ton | 24,000 BTU - 30,000 BTU | Split air conditioner system |
| 3/8 + 5/8 | 3.0 ton - 4.0 ton | 36,000 BTU - 48,000 BTU | Ductless mini split and heat pump |
| 3/8 + 3/4 | 4.5 ton - 6.0 ton | 54,000 BTU - 72,000 BTU | Larger split system air conditioner installation |
| 3/8 + 7/8 | 6.0 ton - 8.0 ton | 72,000 BTU - 96,000 BTU | Commercial ductless HVAC systems |
These capacity values are general product-family references. Final refrigerant-line selection must follow the HVAC equipment manufacturer's exact tubing requirements.
OEM and Custom Split AC Installation Kits
Custom refrigerant line sizes
Custom finished lengths
White PE and Black Rubber insulation options
Multiple insulation thickness options
Custom accessory combinations
OEM logo printing
Private-label supply
Custom packaging
Bulk supply for HVACR wholesalers and distributors
DABUND Factory
DABUND manufactures split-system air conditioner installation kits, insulated copper tubing, mini split line sets, aluminum pipes and related HVAC products.

Insulation Test Documentation
Applicable Polypropylene or Black Rubber insulation configurations are available with UV-resistant options and corresponding ASTM E84, UL94, ASTM D1056 and ASTM G21 test references.
White PE is also available as an insulation option for this installation-kit family. For projects requiring specific compliance documentation, confirm the matching test report for the exact insulation material and thickness ordered.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where buyers can review mini split line sets, split AC installation kits and related HVAC products.

Frequently Asked Questions
What is included in the 10 ft 3/8 x 3/4 Split AC Installation Kit?
The kit includes 3/8 in. and 3/4 in. insulated copper tubing, communication wire cable, a 3 m condensate drain hose, wall pipe, wall cover and related installation parts.
How long is the refrigerant line set?
This SKU uses a 10 ft refrigerant line set.
What AC capacity commonly uses a 3/8 x 3/4 line set?
The 3/8 x 3/4 line-set family is generally referenced for some 4.5–6.0 ton or 54,000–72,000 BTU split air-conditioning systems. Always confirm the equipment manufacturer's requirements.
What copper standards apply to this kit?
The copper tubing is specified to ASTM B280 using C12200 DHP copper.
What insulation materials are available?
White PE and Black Rubber insulation configurations are available.
What is the Black Rubber insulation temperature range?
Black Rubber insulation is specified for approximately -40°C to 120°C.
Does the kit include a drain hose?
Yes. The kit includes a 3 m condensate drain hose.
Does the kit include communication wire?
Yes. Communication wire cable is included. Confirm conductor count, wire gauge, voltage rating and HVAC equipment compatibility before installation.
Are flared copper ends available?
Yes. Copper tube ends can be supplied flared with nuts according to the selected configuration.
Is 10 ft suitable for every 54K–72K split AC system?
No. Confirm the equipment manufacturer's required tube size, minimum and maximum piping lengths, elevation limits and refrigerant-charge requirements.
Does a 10 ft line set require additional refrigerant?
It depends on the HVAC equipment's factory charge and specified piping allowance. Follow the manufacturer's refrigerant charging instructions.
Can this kit be used with heat pumps?
Yes, when the heat-pump manufacturer requires the same refrigerant tubing dimensions and the remaining installation specifications match.
Can this kit be used outdoors?
The insulated copper tubing can be used in compatible indoor-to-outdoor HVAC line runs when the selected insulation configuration and installation method are suitable for the environment.
Can DABUND customize the kit?
Yes. DABUND supports custom lengths, insulation materials, insulation thicknesses, OEM logo printing, private labeling and customized packaging.
Is DABUND a manufacturer?
DABUND manufactures split system air conditioner installation kits, mini split line sets, insulated copper tubing and related HVAC products.
Are free samples available?
Up to 3 free samples are available for qualified customers. Express shipping costs may need to be covered by the buyer. Sample requests can be submitted through the DABUND free sample page.
What payment terms are available?
T/T, L/C at sight and credit card are listed among common payment methods, subject to order details.
What delivery terms are available?
EXW, FOB, CFR and CIF are listed among available international delivery terms.
What is the typical delivery time?
Typical delivery time is approximately 15–20 days, subject to order quantity, customization requirements and production scheduling.
Is professional HVAC installation recommended?
Yes. Refrigerant piping, electrical connection, condensate drainage, connection preparation, pressure testing, evacuation, charging and commissioning should follow the HVAC equipment manufacturer's instructions and applicable local requirements.