50 ft 1/4 in. x 3/8 in. Insulated Copper Tubing
The DABUND 50 ft 1/4 in. x 3/8 in. Insulated Copper Tubing is a paired HVAC refrigerant line set for compatible ductless mini split air conditioners, heat pumps and HVACR systems.
The set combines a 1/4 in. liquid line and a 3/8 in. suction line in a 50 ft / approximately 15.24 m coil, with white embossed PE insulation applied around the copper tubing.
The seamless copper tubing is manufactured from C12200 phosphorus-deoxidized copper and is designed to meet ASTM B280 requirements for air-conditioning and refrigeration field service.
Quick Answer: This line set should be used only when the connected HVAC equipment specifies a 1/4 in. liquid line and a 3/8 in. suction line and permits the planned 50 ft refrigerant route. Confirm copper wall thickness, refrigerant, maximum piping length, vertical separation and additional refrigerant-charge requirements before installation.
1/4 x 3/8 x 50 ft Copper Line Set Specifications
| Product Type | Paired pre-insulated HVAC copper tubing / refrigerant line set |
| Liquid Line Outside Diameter | 1/4 in. / 6.35 mm |
| Suction Line Outside Diameter | 3/8 in. / 9.52 mm |
| Coil Length | 50 ft / approximately 15.24 m |
| Copper Material | C12200 DHP seamless copper |
| Copper Standard | ASTM B280 for air-conditioning and refrigeration field service |
| Insulation Type | White embossed PE multilayer insulation |
| Insulation Thickness | 1/2 in. option shown; 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm options available |
| Insulation Temperature Range | -40°C to 120°C, subject to the selected insulation specification |
| Typical Applications | Compatible mini split systems, heat pumps, VRF/VRV branches and HVACR equipment |
| Customization | Tube sizes, wall thickness, insulation, length, printing, cartons and OEM packaging |
Key Features of the 50 ft Insulated Copper Tubing
ASTM B280 C12200 Copper Tubing
The C12200 DHP seamless copper tubing is designed to meet ASTM B280 requirements for air-conditioning and refrigeration field service.
The copper tubing provides the formability required for professional routing, cutting, flaring and brazing according to the connected equipment and installation requirements.
50 ft Paired Copper Coil
The 50 ft / approximately 15.24 m coil provides additional physical routing length between compatible indoor and outdoor HVAC units.
Always confirm that the HVAC equipment permits the planned piping length and whether additional refrigerant is required.
White Multilayer PE Insulation
The white insulation combines an embossed outer layer, cross-linked PE foam and a closed-cell inner structure to provide thermal coverage, moisture resistance and mechanical protection around the copper tubing.
Protected Copper Tube Ends
Plastic caps help prevent dust, moisture and foreign material from entering the refrigerant tubing during storage, transportation and installation preparation.
OEM and Private-Label Supply
DABUND can customize copper tube combinations, copper wall thicknesses, insulation thicknesses, coil lengths, printed identification, cartons and private-label packaging for HVAC distributors, equipment brands and installation-kit suppliers.
Copper Tube and White PE Insulation Construction
The product consists of two seamless copper tubes supplied together as one insulated coil.
The 1/4 in. tube normally functions as the liquid line and the 3/8 in. tube normally functions as the suction or gas line when specified by the connected equipment. Final tube functions must follow the HVAC equipment manufacturer's piping diagram.
The insulation helps reduce unwanted heat transfer and surface condensation while protecting the copper tubing during handling and installation.
Insulation joints, cut ends and outdoor sections should be sealed and protected correctly to maintain continuous insulation coverage.

C12200 Copper Tubing

White PE Insulation

Protected Tube Ends
Three-Layer White PE Insulation
The white insulation system combines an embossed protective film with cross-linked polyethylene foam and a closed-cell inner layer.
This multilayer construction provides thermal insulation, moisture resistance and mechanical protection for compatible HVAC refrigerant-line installations.


Insulation Production

Insulated Pipe Inventory

Closed-Cell Inner Layer
Embossed PE Outer Layer
The embossed PE outer film provides additional protection against normal abrasion, handling wear and environmental exposure.
Cross-Linked PE Foam Middle Layer
The cross-linked PE foam layer has a dense cellular structure designed to reduce unwanted heat transfer, absorb normal installation impact and limit moisture penetration.
Closed-Cell Inner Layer
The closed-cell inner layer fits around the copper tubing and supports thermal and condensation control within the specified temperature range of the selected insulation configuration.
Applications and Equipment Compatibility
A 1/4 in. liquid line paired with a 3/8 in. suction line is specified by selected ductless mini split and heat-pump models.
This size combination is not universally correct for every system with the same BTU or tonnage rating because tubing requirements vary by brand, equipment model, refrigerant, copper wall thickness, piping length and vertical separation.
Use this 50 ft insulated copper tubing only when the equipment installation manual permits both the 1/4 in. and 3/8 in. outside diameters and the planned 50 ft route.
Installation, cutting, flaring, brazing, nitrogen pressure testing, evacuation and refrigerant charging should be performed according to the equipment instructions and applicable requirements.

Available Insulated Copper Tubing Sizes
DABUND supplies multiple paired copper tube combinations, coil lengths and White PE insulation thicknesses for HVAC wholesalers, importers, installation-kit suppliers and private-label brands.
| Tube Size Combination | Available Lengths | White PE Insulation Thickness | Flame-Retardant Options |
| 1/4 + 3/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 options |
| 1/4 + 1/2 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 options |
| 1/4 + 5/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 options |
| 3/8 + 5/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 options |
| 3/8 + 3/4 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 options |
| 1/2 + 3/4 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 options |
| 3/8 + 7/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 options |
OEM Insulated Copper Tubing Manufacturer
DABUND has manufactured insulated copper pipe, mini split line sets and HVAC installation products since 2008.
Wholesale buyers can specify copper tube dimensions, copper wall thickness, insulation construction, coil length, product printing, carton artwork and packaging requirements.
For an accurate quotation, provide the required liquid-line and suction-line outside diameters, copper wall thickness, insulation thickness, coil length, refrigerant type, working-pressure requirement, annual quantity, packaging design, certification requirements and destination port.
DABUND Factory
DABUND produces insulated copper tubing and HVAC installation products for international distributors, importers and private-label buyers.

Quality Documents and Test Reports
The applicable certificate or test report depends on the exact copper tube and insulation configuration ordered.
Available documentation may reference ASTM B280 for copper tubing and ASTM E84, UL 94, ASTM D1056 or ASTM G21 for applicable insulation configurations.
Final compliance should be confirmed against the exact copper wall thickness, insulation material, insulation thickness and destination-market requirement stated in the quotation and purchase order.

DABUND at HVAC Exhibitions
DABUND participates in international HVAC exhibitions where importers, distributors and project buyers can inspect insulated copper tubing, mini split line sets and related air-conditioning installation products.

Frequently Asked Questions
What does 1/4 x 3/8 x 50 ft mean?
It means the paired line set contains one 1/4 in. outside-diameter copper tube and one 3/8 in. outside-diameter copper tube, each supplied in a 50 ft coil. The metric outside diameters are approximately 6.35 mm and 9.52 mm.
Is this insulated copper tubing suitable for every mini split?
No. It should be used only with equipment that specifies a 1/4 in. liquid line and a 3/8 in. suction line. Confirm tube sizes, copper wall thickness, refrigerant, connections and permitted piping length before installation.
Can the full 50 ft line set be used without adding refrigerant?
Not necessarily. Many HVAC systems are factory charged only for a specified piping length. A longer route may require additional refrigerant according to the equipment manufacturer's instructions.
Why is ASTM B280 important for HVAC copper tubing?
ASTM B280 specifies requirements for seamless copper tube intended for air-conditioning and refrigeration field service and provides a recognized basis for defining ACR copper tubing requirements.
What is the purpose of the White PE insulation?
The multilayer White PE insulation helps reduce unwanted heat transfer and surface condensation while providing mechanical protection around the copper tubing.
Is the White PE insulation suitable for outdoor installation?
Outdoor suitability depends on the selected insulation grade, UV exposure, climate and project requirements. Confirm whether a line-set cover, protective tape, coating or external jacket is required.
Is the tubing compatible with R410A or R32?
Compatibility depends on copper wall thickness, pressure rating, fittings, cleanliness and the HVAC equipment specification. State the refrigerant and required working pressure when ordering.
Are flare nuts or installation accessories included?
The standard package configuration should be confirmed in the quotation. DABUND can supply insulated copper tubing alone or customize installation kits with specified flare nuts, communication cable, drain hose, wall sleeve, wrapping tape and other accessories.
Can DABUND customize copper wall thickness and insulation thickness?
Yes. Copper wall thickness and insulation thickness can be configured according to tube diameter, refrigerant pressure, condensation risk, climate and buyer specification.
Can I order OEM printing and private-label packaging?
Yes. DABUND supports OEM and ODM requirements including company names, size and length markings, labels, carton artwork, manuals and private-label packaging.