This unslit pipe insulation features Halogen-Free NBR construction. It can be used for hot/cold water, chilled water, refrigeration, and air conditioning applications. It can also withstand temperatures between -297° to 250°F.
  • k-flex

  • DABUND

  • copper

  • 1~50M

Inquire
Add to Basket

K-FLEX TITAN Insulated Copper Line Set

K-FLEX TITAN insulated line-set insulation is designed for compatible HVAC and refrigeration piping applications where thermal insulation, moisture resistance, flexibility and outdoor protection are required.

The current product information describes flexible closed-cell insulation with a protective outer layer, pressure-resistant elastomeric construction, UV-aging resistance and multiple technical performance characteristics for HVAC and refrigeration applications.

The source also references preslit and preglued flexible pipe insulation using pressure-sensitive adhesive at the seam and a flexible overlap tape with acrylic adhesive for additional closure security.

Quick Answer: K-FLEX TITAN and TITAN HT are closed-cell insulation solutions referenced on this page for insulated HVAC and refrigeration piping, with UV-aging resistance, mold resistance, compression resilience and ASTM E84 25/50 fire-performance data listed in the current technical information.

Material Notice: The current source contains NBR/PVC, elastomeric foam and chemically cross-linked PE descriptions in different sections. Confirm the exact insulation material, jacket construction and technical data sheet for the selected TITAN or TITAN HT configuration before ordering.

K-FLEX Insulation Product Overview

Product RangeK-FLEX TITAN / K-FLEX TITAN HT
StructureClosed-cell flexible insulation according to current source
Installation Features ReferencedPreslit, preglued seam and pressure-sensitive adhesive configuration
Outdoor ProtectionUV-aging resistance listed in technical data
ApplicationsHVAC, refrigeration, chilled-water and compatible thermal-insulation piping applications
CustomizationOEM/ODM, carton printing and pipe-wall identification are referenced

K-FLEX Product PDF

View the current product document for additional K-FLEX information.

K-FLEX product PDF    Download K-FLEX PDF

K-FLEX TITAN Product Video

Closed-Cell Insulation for HVAC Line Sets

The current source describes flexible closed-cell insulation designed for HVAC, refrigeration and piping applications.

A closed-cell structure helps limit moisture penetration while maintaining flexibility around compatible tubing and fittings.

The product information also emphasizes ductility, oxidation resistance and pressure resistance for the insulated line-set construction.

UV-Resistant Protective Layer

The current product information describes an outer protective layer intended to resist UV aging.

UV-aging resistance is also listed as qualified in the TITAN and TITAN HT technical data presented on this page.

Compression Resilience and Flexibility

Elastomeric insulation is designed to remain flexible around piping while recovering from moderate compression.

The current technical table lists a compression resilience ratio of at least 70% for both K-FLEX TITAN and TITAN HT.

K-FLEX TITAN flexible insulated HVAC line set

K-FLEX Flexibility and Appearance Video

OEM and ODM Customization

The current product information states that OEM and ODM requirements are supported.

Cartons can be designed with customer logos and product-size information, and personalized identification can be discussed for the pipe-wall or insulation surface.

Packaging, printing content and other customization requirements should be confirmed before mass production.

Custom K-FLEX TITAN insulated line set packaging and printing

K-FLEX TITAN Technical Parameters

The following table reorganizes the technical data provided in the current source for K-FLEX TITAN and K-FLEX TITAN HT.

PerformanceK-FLEX TITANK-FLEX TITAN HTTest Method
Density≤70 kg/m³≤90 kg/m³GB/T 6343
Water Absorption Ratio in Vacuum≤10.0%≤10.0%GB/T 17794
Dimensional Stability, 105℃ / 7 Days≤10.0%≤10.0%GB/T 8811
Noise Reduction Performance~32 dB~32 dBGB/T 4760
Fungus ResistanceNo Mold GrowthNo Mold GrowthASTM G21
Operating Temperature Range-50℃ to +105℃-50℃ to +150℃GB/T 17794
CorrosivenesspH NeutralpH NeutralGB/T 17393
Anti-Aging, 150 hSlightly WrinkledSlightly WrinkledGB/T 16259
UV Aging ResistanceQualifiedQualifiedGB/T 16259
Compression Resilience Ratio≥70%≥70%GB/T 6669
Tear Strength9 N/cm9 N/cmGB/T 10808
Fire Resistance Performance25/5025/50ASTM E84

Technical values should be confirmed against the current model-specific data sheet before specifying the product for a project.

K-FLEX TITAN and TITAN HT technical parameters

TITAN vs TITAN HT

ParameterTITANTITAN HT
Density≤70 kg/m³≤90 kg/m³
Temperature Range-50℃ to +105℃-50℃ to +150℃
Compression Resilience≥70%≥70%
Fungus ResistanceNo Mold GrowthNo Mold Growth
ASTM E8425/5025/50

Moisture and Water-Vapor Resistance

Closed-cell insulation is designed to limit moisture movement through the insulation structure.

The current product information references a high humidity-resistance factor and lists a vacuum water-absorption ratio of no more than 10.0% for TITAN and TITAN HT.

Mold and Fungus Resistance

The current technical table lists “No Mold Growth” under ASTM G21 for both K-FLEX TITAN and TITAN HT.

The opening product description also references an antimicrobial agent intended to provide resistance to mold, fungi and bacteria.

ASTM E84 25/50 Fire Performance

Fire-resistance performance of 25/50 according to ASTM E84 is listed in the current technical table for both TITAN and TITAN HT.

Buyers requiring fire-performance documentation should confirm that the applicable report covers the exact insulation configuration and production specification being purchased.

Noise Reduction

The current technical table lists approximately 32 dB noise-reduction performance for both TITAN and TITAN HT under GB/T 4760.

Corrosion Protection

The current product description emphasizes corrosion resistance and protection of the underlying pipe body through the insulation and external protective layer.

The technical data also lists the material as pH neutral under GB/T 17393.

Labor-Saving Installation

The opening source describes preslit and preglued insulation with pressure-sensitive adhesive on the seam.

This type of installation design is intended to reduce cutting and adhesive-application work during installation compared with insulation that requires separate field gluing.

HVAC and Refrigeration Applications

The current source identifies flexible insulation for multiple thermal-insulation applications.

  • Refrigerant piping

  • HVAC insulated line sets

  • Chilled-water piping

  • Hot-water plumbing insulation

  • Liquid-heating systems

  • Solar thermal applications

  • Other compatible insulated piping applications

How to Select K-FLEX TITAN Insulation

Confirm TITAN or TITAN HT

Determine which product range is appropriate for the required operating temperature and project specification. The current table lists TITAN up to +105℃ and TITAN HT up to +150℃.

Confirm Pipe Diameter

Match the insulation inside diameter to the outside diameter of the copper or other compatible pipe being insulated.

Confirm Insulation Thickness

Select insulation thickness according to thermal, condensation-control and project requirements. The current page source does not provide a complete insulation-thickness selection table.

Confirm Outdoor Exposure

For outdoor installation, confirm the required UV resistance, protective jacket and installation method for the selected configuration.

Confirm Fire and Project Requirements

Where ASTM E84, ASTM G21 or other performance documentation is required, confirm that the report applies to the exact model, thickness and construction being supplied.

Information to Confirm Before Ordering

HVAC distributors, wholesalers, contractors and professional installers should confirm:

  • TITAN or TITAN HT configuration

  • Exact insulation material

  • Pipe outside diameter

  • Required insulation thickness

  • Operating temperature

  • Indoor or outdoor installation

  • Required UV protection

  • Required fire-performance documentation

  • Required mold-resistance documentation

  • Length and packaging configuration

  • OEM or private-label printing requirements

  • Order quantity

The current source does not provide a complete pipe-size, insulation-thickness or line-set dimension table. Confirm these specifications for the exact product configuration before ordering.

Frequently Asked Questions

What is K-FLEX TITAN used for?

The current product information identifies it for compatible HVAC, refrigeration and insulated piping applications where flexible closed-cell insulation is required.

What is the difference between K-FLEX TITAN and TITAN HT?

The main differences shown in the current technical table are density and operating-temperature range. TITAN is listed at ≤70 kg/m³ and -50℃ to +105℃, while TITAN HT is listed at ≤90 kg/m³ and -50℃ to +150℃.

What material is K-FLEX TITAN made from?

The current source contains several material descriptions, including NBR/PVC, elastomeric foam and chemically cross-linked PE. Confirm the exact material construction for the selected product before ordering.

What is the operating temperature range?

The current technical table lists -50℃ to +105℃ for TITAN and -50℃ to +150℃ for TITAN HT.

Does K-FLEX TITAN resist mold growth?

The technical table lists “No Mold Growth” under ASTM G21 for TITAN and TITAN HT.

Is K-FLEX TITAN UV resistant?

UV-aging resistance is listed as qualified under GB/T 16259 in the current technical information.

What is the compression resilience ratio?

The current technical table lists a compression resilience ratio of at least 70% for both TITAN and TITAN HT.

What is the tear strength?

The current source lists 9 N/cm for TITAN and TITAN HT under GB/T 10808.

What fire-performance rating is listed?

The current technical table lists 25/50 according to ASTM E84 for both TITAN and TITAN HT.

What is the water absorption ratio?

Vacuum water absorption is listed at no more than 10.0% for both products.

Is the insulation pre-slit and pre-glued?

The opening product information describes preslit and preglued insulation with a pressure-sensitive adhesive seam.

Can the packaging be customized?

Yes. The current source states that OEM/ODM packaging, logo printing and product identification can be discussed.

Can I request a sample?

Sample requests can be discussed according to the current sales policy.    View sample information.

What is the typical delivery time?

The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on configuration, quantity, customization and production schedule.

Related Products

Insulated Copper Pipe works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units, 99.9% Pure copper pipe meets ASTM B280 and C12200 standard, 1/4“-3/8” is the out dimension in inch, 6.35mm - 9.52mm is the out dimension in metric.
Used with nuts and bolts and provide a greater bearing surface to prevent the nut or bolt head tearing through the fastened material, flat washers are used to support and spread the load across the baring area of the bolt and nut to prevent pull through.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.