75 ft 1/4 in. x 1/2 in. Insulated Copper Pipe
DABUND 75 ft 1/4 in. x 1/2 in. Insulated Copper Pipe provides paired refrigerant tubing for compatible mini split air conditioners, heat pumps, HVAC systems and refrigeration applications.
The paired line set combines a 1/4 in. copper tube with a 1/2 in. copper tube and provides a 75 ft length, approximately 22.86 m, for HVAC installations requiring additional piping reach between indoor and outdoor equipment.
Factory-applied insulation helps reduce unwanted thermal exchange and surface condensation while protecting the copper tubing during compatible residential and commercial air-conditioning installations.
Quick Answer: This 75 ft 1/4 x 1/2 insulated copper pipe is intended for compatible HVAC systems requiring this exact tubing combination. The wider DABUND product family lists 1/4 x 1/2 as a general reference for 1.5–2.0 ton / 12,000–18,000 BTU systems, but equipment manufacturer specifications must take priority.
Insulated Copper Pipe Video
75 ft 1/4 x 1/2 Copper Pipe Specifications
| Product Type | Insulated HVAC Refrigerant Copper Line Set |
| Line Set Size | 1/4 in. + 1/2 in. |
| Tube Size 1 | 1/4 in. / 6.35 mm |
| Tube Size 2 | 1/2 in. / 12.70 mm |
| Length | 75 ft / approximately 22.86 m |
| Copper Type | Refrigeration-grade soft annealed copper tubing; product imagery identifies 99.9% pure copper |
| Featured Insulation | Black Rubber |
| Family Insulation Thicknesses | 8 / 9 / 10 / 13 / 19 / 25.4 mm |
| Listed Insulation Temperature Range | -40°C to 120°C; confirm applicability to the exact ordered insulation configuration |
| General Capacity Reference | 1.5–2.0 Ton / 12,000–18,000 BTU |
| Applications | Compatible Mini Split / Heat Pump / HVAC / Refrigeration Systems |
Refrigeration-Grade Soft Copper Tubing
The source page describes the tubing as refrigeration-grade, soft annealed copper designed for HVAC and refrigeration applications.
Soft copper tubing provides installation flexibility for routes that require bends around walls, equipment, structural elements or other obstacles.
Thermal Conductivity
Copper provides high thermal conductivity for refrigerant piping applications and is commonly used in air-conditioning and refrigeration systems.
Corrosion Resistance
Refrigeration-grade copper provides corrosion resistance when properly installed and used within the operating conditions specified by the HVAC equipment manufacturer.
Smooth Refrigerant Flow
Smooth copper tubing provides a continuous refrigerant path when properly sized and installed for the selected HVAC system.
Black Rubber Insulation
Black Rubber is the insulation configuration prominently shown in the product images and the wider insulated copper-pipe family table.
Factory-applied insulation helps limit heat transfer and reduces surface condensation around cold refrigerant tubing.
Closed-Cell Insulation
The source describes the insulation as providing both a thermal insulation layer and moisture-resistant layer around the copper tubing.
Moisture and Condensation Protection
The insulation structure helps reduce water-vapor penetration and surface condensation during normal HVAC operation.
UV-Resistant Configuration
UV-resistant insulation is referenced on the source page. Final outdoor suitability depends on the exact insulation configuration, environmental exposure and installation method.
Listed Temperature Range
The Black Rubber insulation section lists a temperature range of approximately -40°C to 120°C. Confirm this range for the exact configuration ordered.
HVAC Copper Pipe and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Protective Plastic Cap
Black Rubber Insulation Detail
The Black Rubber insulation surrounds the copper refrigerant tubing to provide thermal and moisture protection.

75 ft Length for Extended Installation Routes
The 75 ft line set equals approximately 22.86 m and provides additional routing flexibility where compatible indoor and outdoor HVAC equipment are separated by a greater distance.
A continuous tubing run can reduce unnecessary intermediate joints compared with connecting several shorter pieces.
The physical 75 ft length does not mean that every mini split or heat-pump system permits a 75 ft installed refrigerant run. Always confirm the equipment manufacturer's piping limits before installation.
Compatible HVAC Applications
Compatible mini split air conditioners
Ductless HVAC systems
Heat-pump systems
Residential air-conditioning installations
Commercial HVAC projects requiring this pipe size
Compatible refrigeration equipment
Replacement AC refrigerant lines
Final compatibility must be confirmed from the equipment manufacturer's required copper tube sizes, refrigerant type, permitted piping length and installation requirements.
General 12,000–18,000 BTU Capacity Reference
The wider DABUND product family lists the 1/4 in. + 1/2 in. tubing combination as a general reference for some 1.5–2.0 ton mini split systems.
The corresponding family reference is approximately 12,000–18,000 BTU.
These capacity values are general references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact specifications.
Important Checks for a 75 ft Refrigerant Run
Confirm Exact Copper Tube Sizes
Verify that the selected HVAC equipment specifically requires a 1/4 in. and 1/2 in. copper refrigerant-line combination.
Verify Maximum Permitted Piping Length
Confirm that the selected equipment permits the proposed 75 ft refrigerant piping route.
Check Maximum Elevation Difference
If the indoor and outdoor units are installed at different elevations, verify the manufacturer's maximum permitted vertical separation.
Check Additional Refrigerant Charge
A 75 ft refrigerant run may require additional refrigerant depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions.
Check Equivalent Piping Length
Bends, fittings and elevation changes may affect equivalent piping length. Follow the equipment manufacturer's engineering limits rather than relying only on the physical copper length.
Installation Guidelines
Plan the Complete Piping Route
Measure and plan the complete refrigerant route before uncoiling, cutting or modifying the copper tubing.
Cut and Flare with HVAC Tools
The source describes the tubing as suitable for cutting and flaring with standard HVAC tools. Prepare connections according to the HVAC equipment manufacturer's instructions.
Avoid Sharp Bends and Kinks
Use appropriate HVAC tube-bending methods and suitable bend radii to reduce the risk of copper deformation and refrigerant-flow restriction.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and wall penetrations.
Support the Refrigerant Line
Use suitable HVAC-rated supports, clips or straps along the piping route to reduce sagging, vibration and mechanical stress.
Pressure Test and Evacuate Before Startup
Refrigerant piping should be leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.
Black Rubber Insulated Copper Line Set

Available Insulated Copper Pipe Sizes
| Size | Available Lengths | Black Rubber Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 75 ft / approximately 22.86 m. The wider product-family table lists 20 m and 25 m as nearby standard metric lengths, so buyers should specify the exact finished 75 ft configuration when ordering.
General Line Set Size and Capacity Reference
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
These capacity values are general product-family references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact requirements.
OEM and Customization Options
DABUND supports OEM and ODM supply for HVAC distributors, wholesalers and project buyers.
Different insulated copper line-set lengths
Custom insulation thickness
Packaging customization
OEM and ODM configurations
Bulk supply for distributors and contractors
DABUND Insulated Copper Pipe Factory
DABUND manufactures insulated copper pipe, mini split line sets and related HVAC components for distributors, contractors and professional project buyers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations reference ASTM E84, UL94, ASTM D1056 and ASTM G21.
Black Rubber is the main insulation configuration shown on this page. Buyers requiring project-specific compliance documentation should still confirm the exact insulation material, thickness and corresponding test report for the ordered 75 ft configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review insulated copper pipe, mini split line sets and related HVAC products.

Frequently Asked Questions
What is 75 ft 1/4 x 1/2 insulated copper pipe used for?
It is used as refrigerant piping between compatible indoor and outdoor HVAC or refrigeration equipment requiring a 1/4 in. and 1/2 in. copper tube combination.
How long is the copper line set?
This SKU is 75 ft long, approximately 22.86 m.
What size HVAC system can use a 1/4 x 1/2 line set?
The wider DABUND product family lists 1/4 x 1/2 as a general reference for some 1.5–2.0 ton or 12,000–18,000 BTU systems. Final tubing size must follow the HVAC equipment manufacturer's exact specification.
What copper material is used?
The source describes refrigeration-grade soft annealed copper tubing, while the product imagery identifies 99.9% pure copper.
What insulation is used?
Black Rubber is the insulation configuration prominently shown in the product imagery and wider insulated copper-pipe family table.
What insulation thicknesses are available?
The wider Black Rubber family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
What is the listed insulation temperature range?
The source Black Rubber insulation section lists approximately -40°C to 120°C. Confirm the applicable range for the exact insulation configuration ordered.
Are the copper pipe ends pre-flared?
The current source page does not clearly state that this exact 75 ft SKU is supplied pre-flared. The tubing is described as suitable for cutting and flaring using standard HVAC tools.
Can every mini split use a 75 ft refrigerant line?
No. Confirm the HVAC equipment manufacturer's maximum permitted piping length, maximum elevation difference and refrigerant-charge requirements before installation.
Does a 75 ft refrigerant run require additional refrigerant?
Additional refrigerant may be required depending on the equipment's factory charge and included piping allowance. Follow the equipment manufacturer's charging instructions.
Can this insulated copper pipe be used outdoors?
UV-resistant and weather-resistant insulation characteristics are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation configuration and exposure conditions.
Can the 75 ft copper pipe be shortened?
Yes. The source describes the tubing as suitable for cutting and flaring using standard HVAC tools. Installation should follow the equipment manufacturer's requirements.
Can DABUND customize the insulated copper line set?
Yes. The source page references OEM and ODM customization for different lengths, insulation thicknesses and packaging configurations.
Is professional HVAC installation recommended?
Yes. Refrigerant piping should be installed, leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.