50 ft 1/4 in. x 1/2 in. Insulated Copper Pipe
DABUND 50 ft 1/4 in. x 1/2 in. Insulated Copper Pipe provides paired refrigerant tubing for compatible mini split air conditioners, heat pumps, HVAC systems and refrigeration applications.
The paired tubing combines a 1/4 in. liquid line with a 1/2 in. suction line and provides a 50 ft length, approximately 15.24 m, for installations requiring additional refrigerant piping reach between indoor and outdoor equipment.
The source product information specifies 99.9% pure copper with ASTM B280 / C12200 referenced for the refrigerant tubing, together with factory-applied insulation for HVAC and refrigeration use.
Quick Answer: This 50 ft 1/4 x 1/2 insulated copper pipe combines a 6.35 mm liquid line and 12.70 mm suction line with factory-applied insulation for compatible mini split, heat-pump and HVAC installations.
Insulated Copper Pipe Video
50 ft 1/4 x 1/2 Copper Pipe Specifications
| Product Type | Pre-Insulated HVAC Refrigerant Copper Line Set |
| Line Set Size | 1/4 in. + 1/2 in. |
| Liquid Line | 1/4 in. / 6.35 mm |
| Suction Line | 1/2 in. / 12.70 mm |
| Length | 50 ft / approximately 15.24 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 |
| Featured Insulation | Black Rubber shown in product image and family table |
| Other Source-Listed Insulation | UV-resistant polyethylene foam; White / Black insulation options are listed |
| Family Insulation Thicknesses | 8 / 9 / 10 / 13 / 19 / 25.4 mm |
| Listed Temperature Range | -40°C to 120°C; confirm applicability to the exact insulation configuration |
| Source-Listed Pressure Range | 2100–7000 PSI; actual allowable pressure depends on tube dimensions, wall thickness and temperature |
| Listed Refrigerants | R410A / R32 / R22; final compatibility must follow equipment specifications |
| General Capacity Reference | 1.5–2.0 Ton / 12,000–18,000 BTU based on the product-family table |
| Applications | Compatible Mini Split / Heat Pump / Central HVAC / Refrigeration |
50 ft Refrigerant Line for HVAC Installations
The 50 ft / 15.24 m length provides routing flexibility for compatible installations where indoor and outdoor HVAC equipment are separated by a moderate distance.
A continuous copper run can reduce unnecessary intermediate joints compared with connecting several shorter tubing sections, provided the complete piping route remains within the equipment manufacturer's permitted limits.
Typical applications may include residential mini split installations, heat pumps, offices, apartments, central air-conditioning systems and compatible refrigeration equipment.
1/4 in. Liquid Line and 1/2 in. Suction Line
This line set uses a 1/4 in. copper liquid line and a 1/2 in. copper suction line.
Buyers should verify that the selected mini split, heat-pump, central HVAC or refrigeration equipment specifically requires these exact refrigerant-line dimensions.
Required tubing sizes vary between HVAC manufacturers and individual models, so nominal system capacity should not be used as the sole selection criterion.
ASTM B280 C12200 Copper Tubing
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200 for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC and refrigeration piping applications.
Appropriate HVAC tube-bending tools and suitable bend radii should be used to reduce the risk of kinking, flattening or refrigerant-flow restriction.
Pressure Capability for R410A, R32 and R22 Applications
The source page lists a pressure range of 2100–7000 PSI and references R410A, R32 and R22 applications.
Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and the exact tubing configuration. Confirm the applicable technical specification before installation.
Factory-Applied Insulation
The source technical specification identifies UV-resistant polyethylene foam insulation, while the product images and family table prominently show a Black Rubber configuration.
White and Black insulation options are also listed. Buyers should therefore confirm the exact insulation material and thickness required for the ordered 50 ft SKU.
Thermal Insulation
Factory-applied insulation helps reduce unwanted thermal exchange between the refrigerant tubing and surrounding environment.
Condensation Protection
Closed-cell insulation helps reduce moisture penetration and surface condensation around cold refrigerant lines.
UV-Resistant Configurations
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability depends on the exact insulation material, thickness, exposure conditions and installation method.
Listed Temperature Range
The source specification lists an insulation temperature range of approximately -40°C to 120°C. Confirm the applicable rating for the exact insulation configuration ordered.
Three-Layer Polyethylene Insulation Structure
The source page describes a three-layer polyethylene-based insulation structure for applicable configurations.
Outer Layer
An embossed polyethylene film is referenced as the outer protective layer with UV-resistant and wear-resistant characteristics.
Middle Layer
IXPE foam is referenced for thermal protection, impact absorption and moisture resistance.
Inner Layer
A closed-cell inner structure is referenced for thermal insulation and reduced water penetration.
Copper Pipe and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Protective Plastic Cap
Black Rubber Insulation Detail
Black Rubber insulation is prominently shown in the source product imagery and wider insulated copper-pipe family table.

Compatible HVAC Applications
Compatible ductless mini split air conditioners
Heat-pump systems
Central air-conditioning systems requiring this pipe size
Compatible VRF / VRV systems
Refrigeration equipment
Residential HVAC replacement projects
Final compatibility must be confirmed from the equipment manufacturer's required liquid-line diameter, suction-line diameter, refrigerant, design pressure and permitted piping length.
General 12,000–18,000 BTU Capacity Reference
An earlier paragraph on the source page broadly mentions 9,000–18,000 BTU applications for this product.
However, the wider DABUND product-family table specifically maps the 1/4 in. + 1/2 in. configuration to approximately 1.5–2.0 ton and 12,000–18,000 BTU systems.
For this page, 12,000–18,000 BTU should be treated as the more specific general family reference. Final line-set sizing must follow the HVAC equipment manufacturer's exact specifications.
Important Checks for a 50 ft Refrigerant Run
Verify Maximum Permitted Piping Length
Confirm that the selected HVAC system permits the proposed 50 ft refrigerant piping route.
Confirm Exact Refrigerant Pipe Sizes
Verify that the equipment specifically requires a 1/4 in. liquid line and 1/2 in. suction line.
Check Maximum Elevation Difference
If indoor and outdoor units are installed at different elevations, confirm the manufacturer's maximum permitted vertical separation.
Check Refrigerant Charge Requirements
A 50 ft refrigerant run may require additional refrigerant depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions.
Installation Guidelines
Plan the Piping Route
Measure and plan the complete refrigerant route before uncoiling, cutting or modifying the tubing.
Avoid Sharp Bends and Kinks
Use appropriate HVAC tube-bending methods and suitable bend radii to reduce the risk of copper deformation or restricted refrigerant flow.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and wall penetrations.
Keep Copper Ends Protected
Keep open copper tube ends capped or sealed during storage and installation to reduce moisture and contamination entering the refrigerant circuit.
Pressure Test and Evacuate Before Startup
Refrigerant piping should be pressure-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.
OEM and Custom Insulated Copper Pipe Options
Custom insulation thickness
White or black insulation options
Custom logo printing
Customized packaging
Meter marking printing
Custom copper tube lengths
Private-label branding
Black Rubber Insulated Copper Line Set

Available Insulated Copper Pipe Sizes
| Size | Available Lengths | Black Rubber Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 50 ft / approximately 15.24 m. The wider family table lists 15 m as the closest standard metric production length, so buyers should specify the exact finished 50 ft configuration when ordering.
General Line Set Size and Capacity Reference
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
These capacity values are general product-family references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact specifications.
DABUND Insulated Copper Pipe Factory
DABUND manufactures insulated copper pipe, mini split line sets and related HVAC components for distributors, contractors and project buyers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations reference ASTM E84, UL94, ASTM D1056 and ASTM G21.
Because the source page also lists polyethylene foam insulation, buyers requiring compliance documentation should confirm the exact insulation material, thickness and corresponding test report for the ordered 50 ft configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review insulated copper pipe, mini split line sets and related HVAC products.

Frequently Asked Questions
What is 50 ft 1/4 x 1/2 insulated copper pipe used for?
It is used as refrigerant piping between compatible indoor and outdoor HVAC or refrigeration equipment requiring a 1/4 in. liquid line and 1/2 in. suction line.
How long is this copper line set?
The product is 50 ft long, approximately 15.24 m.
What size HVAC system can use a 1/4 x 1/2 line set?
The wider DABUND product-family table lists 1/4 x 1/2 as a general reference for some 1.5–2.0 ton or 12,000–18,000 BTU systems. Final pipe size must follow the equipment manufacturer's exact specification.
Why does an earlier section mention 9,000–18,000 BTU?
The source page contains a broader 9,000–18,000 BTU statement, while the detailed product-family table specifically maps 1/4 x 1/2 to 12,000–18,000 BTU. The equipment manufacturer's required tube sizes should always take priority.
What copper material is used?
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200.
What insulation is used?
The source technical specification lists UV-resistant polyethylene foam, while the product image and family table prominently show Black Rubber insulation. White and Black insulation options are also listed, so the exact ordered configuration should be confirmed.
What insulation thicknesses are available?
The wider Black Rubber product-family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
What is the listed insulation temperature range?
The source page lists approximately -40°C to 120°C. Confirm the applicable range for the exact insulation configuration ordered.
Is this copper pipe compatible with R410A, R32 and R22?
R410A, R32 and R22 are referenced on the source page. Final compatibility must be confirmed against the HVAC equipment manufacturer's refrigerant, pipe-size and design-pressure requirements.
What is the pressure rating?
The source page lists a pressure range of 2100–7000 PSI. Actual allowable pressure depends on copper tube diameter, wall thickness, operating temperature and exact product configuration.
Can every mini split use a 50 ft refrigerant run?
No. Confirm the HVAC equipment manufacturer's maximum permitted piping length, maximum elevation difference and refrigerant-charge requirements before installation.
Does a 50 ft refrigerant run require additional refrigerant?
Additional refrigerant may be required depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions for the actual installed length.
Can this insulated copper pipe be used outdoors?
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation material and environmental exposure conditions.
Can the 50 ft copper pipe be shortened?
Yes. The copper tubing can be shortened using appropriate HVAC cutting, deburring and connection procedures while following the equipment manufacturer's installation requirements.
Can DABUND customize the insulated copper pipe?
Yes. The source page lists custom insulation thickness, white or black insulation, logo printing, customized packaging, meter markings and custom copper tube lengths.
Is professional HVAC installation recommended?
Yes. Refrigerant piping should be installed, pressure-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.