100 ft 1/4 in. x 1/2 in. Pre-Insulated Copper Tube
DABUND 100 ft 1/4 in. x 1/2 in. Pre-Insulated Copper Tube provides paired refrigerant piping for compatible mini split air conditioners, heat pumps, central HVAC systems and refrigeration applications.
The line set combines a 1/4 in. liquid line with a 1/2 in. suction line and provides a continuous 100 ft length, approximately 30.48 m, for projects requiring an extended refrigerant piping route.
The source product information specifies 99.9% pure copper with ASTM B280 / C12200 referenced for the tubing, together with factory-applied insulation for professional HVAC and refrigeration installations.
Quick Answer: This 100 ft 1/4 x 1/2 pre-insulated copper tube combines a 6.35 mm liquid line and 12.70 mm suction line with White PE insulation for compatible long-distance mini split, heat-pump and HVAC installations.
Pre-Insulated Copper Tube Video
100 ft 1/4 x 1/2 Copper Tube Specifications
| Product Name | 100 ft 1/4 x 1/2 Pre-Insulated Copper Tube |
| Model | DBJ-003 |
| Brand | DABUND |
| Line Set Size | 1/4 in. + 1/2 in. |
| Liquid Line | 1/4 in. / 6.35 mm |
| Suction Line | 1/2 in. / 12.70 mm |
| Length | 100 ft / approximately 30.48 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 |
| Featured Insulation | White PE / high-density polyethylene foam |
| Color Options | White / Black |
| Listed Temperature Range | -40°C to 120°C; confirm applicability to the exact insulation configuration |
| Source-Listed Pressure Range | 2100–7000 PSI; actual allowable pressure depends on tube dimensions, wall thickness and operating temperature |
| Listed Refrigerants | R410A / R32 / R22; final compatibility must follow equipment specifications |
| General Capacity Reference | 1.5–2.0 Ton / 12,000–18,000 BTU |
| Applications | Compatible Mini Split / Heat Pump / Central HVAC / Refrigeration |
100 ft Long Refrigerant Line for HVAC Projects
The 100 ft / 30.48 m continuous copper line provides routing flexibility for compatible HVAC installations where indoor and outdoor equipment are separated by a greater distance.
A continuous tubing run can reduce unnecessary intermediate joints compared with joining several shorter sections, provided the complete installation remains within the HVAC equipment manufacturer's piping limits.
Typical project environments may include homes, apartments, offices, commercial buildings and compatible refrigeration installations.
1/4 in. Liquid Line and 1/2 in. Suction Line
The source configuration identifies the 1/4 in. copper tube as the liquid refrigerant line and the 1/2 in. tube as the suction return line.
Buyers should verify that the selected mini split, heat-pump, central HVAC or refrigeration equipment specifically requires these exact tubing diameters.
Required pipe sizes vary between HVAC manufacturers and equipment models, so nominal system capacity should not be used as the sole selection criterion.
ASTM B280 C12200 Copper Refrigerant Tubing
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200 for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible air-conditioning and refrigeration piping applications.
Appropriate HVAC tube-bending tools and suitable bend radii should be used to reduce the risk of kinking, flattening or restricting refrigerant flow.
Pressure Capability for R410A, R32 and R22 Applications
The source page lists a pressure range of 2100–7000 PSI and references R410A, R32 and R22 refrigerant applications.
Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and exact tubing configuration. Confirm the applicable technical specification before use with a particular HVAC or refrigeration system.
White PE Pre-Insulated Copper Tube
White PE insulation is the main configuration shown in the product images and wider pre-insulated copper-tube family table on this page.
The source specification identifies high-density polyethylene foam insulation, while other sections also reference Polypropylene insulation configurations.
Thermal Insulation
Factory-applied insulation helps reduce unwanted thermal exchange around the copper refrigerant tubing.
Condensation Protection
A closed-cell insulation structure helps reduce moisture penetration and surface condensation around cold refrigerant piping.
UV-Resistant Configuration
UV-resistant insulation is referenced on the source page. Final outdoor suitability depends on the exact insulation material, thickness, exposure conditions and installation method.
Listed Temperature Range
The source specification lists an insulation temperature range of approximately -40°C to 120°C. Confirm the applicable rating for the exact configuration ordered.
Three-Layer White PE Insulation Structure
Outer Layer
The source describes an anti-aging embossed PE film outer layer with UV resistance and wear protection.
Middle Layer
IXPE foam is referenced as the middle layer for thermal insulation and moisture resistance.
Inner Layer
A closed-cell inner structure is referenced for thermal insulation and reduced water penetration.
Copper Tube and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Protective Plastic Cap
White PE Embossed Insulation

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
Compatible HVAC Applications
Compatible ductless mini split air conditioners
Heat-pump systems
Central air-conditioning systems requiring this pipe size
VRF / VRV systems requiring this tubing combination
Compatible refrigeration equipment
HVAC replacement projects
Final compatibility must be confirmed from the equipment manufacturer's required liquid-line diameter, suction-line diameter, refrigerant, operating pressure and permitted piping length.
General 12,000–18,000 BTU Capacity Reference
The wider DABUND product family lists the 1/4 in. + 1/2 in. configuration as a general reference for some 1.5–2.0 ton mini split systems.
The corresponding family reference is approximately 12,000–18,000 BTU.
These values are general references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact technical requirements.
Important Checks for a 100 ft Refrigerant Run
Verify Maximum Permitted Piping Length
A physical 100 ft coil does not mean every HVAC system permits a 100 ft installed refrigerant run. Confirm the equipment manufacturer's maximum piping length before installation.
Confirm Exact Refrigerant Pipe Sizes
Verify that the selected equipment specifically requires a 1/4 in. liquid line and 1/2 in. suction line.
Check Maximum Elevation Difference
For multi-story installations, confirm the maximum permitted vertical separation between the indoor and outdoor equipment.
Check Additional Refrigerant Charge
A 100 ft refrigerant run may require additional refrigerant beyond the equipment's factory charge. Follow the manufacturer's charging instructions for the actual installed piping length.
Check Equivalent Piping Length
Bends, fittings and elevation changes can increase equivalent piping length. Follow the equipment manufacturer's engineering limits rather than relying only on physical copper length.
Provide Proper Pipe Support
Use suitable HVAC-rated supports, clips or straps to reduce sagging, vibration and mechanical stress along the extended piping route.
Installation Guidelines
Plan the Complete Piping Route
Measure and plan the complete piping route before uncoiling, cutting or modifying the copper tubing.
Avoid Sharp Bends and Kinks
Use suitable HVAC tube-bending methods and appropriate bend radii to reduce the risk of tube deformation and refrigerant-flow restriction.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and wall penetrations.
Keep Copper Ends Protected
Keep open copper tube ends capped or sealed during storage and installation to reduce moisture and contamination entering the refrigerant circuit.
Pressure Test and Evacuate Before Startup
Refrigerant piping should be pressure-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.
OEM and Custom Copper Line Set Options
Custom insulation thickness
White or black insulation options
Logo printing
Customized packaging
Meter marking printing
Custom copper tube lengths
Company name and size marking on insulation
White PE Pre-Insulated Copper Line Set

Available Pre-Insulated Copper Tube Sizes
| Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 100 ft / approximately 30.48 m. The wider family table lists 30 m as the closest standard metric production length, so buyers should specify the exact finished 100 ft configuration when ordering.
General Line Set Size and Capacity Reference
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
These capacity values are general product-family references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact specifications.
DABUND Pre-Insulated Copper Tube Factory
DABUND manufactures pre-insulated copper tubing, mini split line sets and related HVAC components for distributors, contractors and project buyers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations reference ASTM E84, UL94, ASTM D1056 and ASTM G21.
Because the featured configuration on this page is White PE / polyethylene foam, buyers requiring compliance documentation should confirm the exact insulation material, thickness and corresponding test report for the ordered SKU.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review pre-insulated copper tubing, mini split line sets and related HVAC products.

Frequently Asked Questions
What is 100 ft 1/4 x 1/2 pre-insulated copper tube used for?
It is used as refrigerant piping between compatible indoor and outdoor HVAC or refrigeration equipment requiring a 1/4 in. liquid line and 1/2 in. suction line.
How long is this copper tube?
The product is 100 ft long, approximately 30.48 m.
What size HVAC system can use a 1/4 x 1/2 line set?
The wider DABUND product family lists 1/4 x 1/2 as a general reference for some 1.5–2.0 ton or 12,000–18,000 BTU systems. Final tubing size must follow the equipment manufacturer's exact specification.
What copper material is used?
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200.
What insulation is used?
White PE / high-density polyethylene foam is the main insulation configuration shown on this page. Black insulation is also listed as an available color option.
What insulation thicknesses are available?
The wider White PE product-family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
What is the listed insulation temperature range?
The source page lists approximately -40°C to 120°C. Confirm the applicable range for the exact insulation configuration ordered.
Is this copper tubing compatible with R410A, R32 and R22?
R410A, R32 and R22 are referenced on the source page. Final compatibility must be confirmed against the HVAC equipment manufacturer's refrigerant, pipe-size and design-pressure requirements.
What is the pressure rating?
The source page lists a pressure range of 2100–7000 PSI. Actual allowable pressure depends on tube diameter, wall thickness, operating temperature and exact product configuration.
Can every HVAC system use a 100 ft refrigerant run?
No. Confirm the HVAC equipment manufacturer's maximum permitted piping length, maximum elevation difference and refrigerant-charge requirements before installation.
Does a 100 ft refrigerant run require additional refrigerant?
Additional refrigerant may be required depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions for the actual installed length.
Can this pre-insulated copper tube be used outdoors?
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation material and environmental exposure conditions.
Can the 100 ft copper tube be shortened?
Yes. The tubing can be shortened using appropriate HVAC cutting, deburring and connection procedures while following the equipment manufacturer's installation requirements.
Can DABUND customize the copper line set?
Yes. The source page lists custom insulation thickness, white or black insulation, logo printing, customized packaging, meter markings and custom tube lengths.
Is professional HVAC installation recommended?
Yes. Refrigerant piping should be installed, pressure-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.