50 ft 1/2 in. x 3/4 in. Insulated Copper Tube Kit
The DABUND 50 ft 1/2 in. x 3/4 in. Insulated Copper Tube Kit is a pre-insulated HVAC refrigerant line set and accessory package for compatible mini split air conditioners, heat pumps, ductless HVAC systems, VRF systems and split AC installations.
The kit includes a 50 ft / approximately 15.24 m pair of 1/2 in. and 3/4 in. copper refrigerant tubes with factory-applied White PE insulation, communication wire cable, 3 m drain hose, wall pipe, wall cover, flare nuts and installation accessories.
Both copper tube ends are flared and supplied with nuts to support compatible HVAC refrigerant connections.
Quick Answer: This 1/2 in. x 3/4 in. line-set combination should be selected when the HVAC equipment manufacturer specifically requires these two copper tube diameters. There is no reliable universal tonnage or BTU mapping for the 1/2 x 3/4 combination.
50 ft Insulated Copper Tube Kit Video
Complete HVAC Refrigerant Line Set and Accessories
This product combines insulated copper refrigerant tubing with key installation accessories for compatible HVAC projects.
50 ft / approx. 15.24 m paired copper refrigerant tubing
1/2 in. and 3/4 in. copper tube sizes
12.7 mm and 19.05 mm metric sizes
Factory-applied White PE insulation
Pre-flared copper tube ends
Flare nuts included
Communication wire cable included
3 m condensate drain hose included
Wall pipe included
Wall cover included
Additional installation parts included
Key Features
50 ft insulated copper tube kit for compatible HVAC installations
1/2 in. x 3/4 in. paired refrigerant tubing
ASTM B280 and C12200 DHP copper specification
High-density closed-cell White PE insulation
Black Rubber insulation options also available
White PE insulation thickness options available
Black Rubber insulation thickness options available
Pre-flared tube ends with flare nuts
3 m condensate drain hose included
Communication wiring cable included
Wall pipe and protective wall cover included
OEM logo printing and private-label packaging available
Technical Specifications
| Specification | Detail |
| Product Name | 50 ft 1/2 in. x 3/4 in. Insulated Copper Tube |
| Length | 50 ft / approx. 15.24 m |
| Line Size | 1/2 in. x 3/4 in. |
| Metric Size | 12.7 mm x 19.05 mm |
| Copper Standard | ASTM B280 and C12200 DHP |
| Insulation Material | High-density closed-cell polyethylene foam / White PE insulation |
| Insulation Options | White PE and Black Rubber insulation available |
| Temperature Range | -40°C to 120°C |
| Included Accessories | Wire cable, drain hose, wall pipe, wall cover, flare nuts and installation parts |
| Application | Mini split, heat pump, ductless AC, VRF and HVACR installation |
1/2 in. x 3/4 in. Refrigerant Tube Size
This product combines 1/2 in. and 3/4 in. copper refrigerant tubes with outside diameters of approximately 12.7 mm and 19.05 mm.
The exact liquid-line and suction-line functions of the two tubes should be confirmed from the HVAC equipment manufacturer's piping diagram.
Do not select this line-set combination using nominal HVAC capacity alone. Required refrigerant-line sizes vary between manufacturers and equipment models.
50 ft Length for HVAC Installation
The 50 ft / approximately 15.24 m tubing length provides additional routing flexibility for compatible residential and light commercial HVAC projects.
A physical 50 ft line set does not mean every HVAC system permits a 50 ft refrigerant run. Confirm the equipment manufacturer's maximum piping length, minimum piping length where applicable, elevation limit and refrigerant-charge requirements before installation.
ASTM B280 and C12200 DHP Copper Tube
The copper tubing is specified to ASTM B280 using C12200 DHP copper for HVAC refrigerant-line applications.
Confirm the required copper tube wall thickness and pressure specification against the HVAC equipment requirements for the exact project.
Pre-Flared Ends with Flare Nuts
Both copper tube ends are flared and supplied with nuts for compatible HVAC refrigerant connections.
Inspect each flare surface before assembly and tighten flare connections using the torque specified by the HVAC equipment manufacturer.
Complete the required pressure testing, leak testing and evacuation before commissioning the refrigerant system.
White PE Insulation
The primary insulation configuration uses high-density closed-cell polyethylene foam with a White PE outer structure.
Thermal Protection
The insulation helps reduce unwanted heat transfer between the copper refrigerant tubing and the surrounding environment.
Condensation Control
The closed-cell structure helps reduce surface condensation and moisture penetration around cold refrigerant tubing.
Temperature Range
Applicable insulation configurations are specified for temperatures from approximately -40°C to 120°C.
UV-Resistant Outer Surface
UV-resistant insulation configurations are available for compatible indoor-to-outdoor HVAC refrigerant-line routes.
White PE and Black Rubber Insulation Options
White PE and Black Rubber insulation options are available for different HVAC market and project requirements.
White PE insulation thickness options include 3/8 in., 1/2 in., 3/4 in., 1 in., 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.
Black Rubber insulation thickness options include 1/2 in., 3/4 in., 1 in., 13 mm, 17 mm, 19 mm and 25.4 mm.
Communication Wire Cable
A communication wire cable is included for compatible indoor-to-outdoor HVAC wiring applications.
Confirm conductor count, wire gauge, voltage rating and equipment compatibility against the exact HVAC model before installation.
3 m Condensate Drain Hose
The kit includes a 3 m condensate drain hose for routing condensate away from the compatible indoor unit.
Install the drain hose with the slope and routing conditions required by the HVAC equipment manufacturer.
Wall Pipe and Wall Cover
The included wall pipe and wall cover are used around the wall penetration where refrigerant tubing, wiring and drain components pass between indoor and outdoor areas.
These components help protect the line set at the penetration point and provide a cleaner finished installation.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Copper Nut
Three-Layer Insulation Structure
Outer Layer: UV-Resistant PE Film
The outer layer uses UV-resistant embossed PE film to provide wear resistance and protection during compatible indoor and outdoor HVAC installations.
Middle Layer: IXPE Foam
The middle layer uses dense-cell IXPE foam for thermal insulation, water resistance and impact protection.
Inner Layer: Closed-Cell Structure
The inner closed-cell structure helps maintain thermal coverage and moisture resistance around the copper tubing.

Insulation Production and Storage

Thermal Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
HVAC and Refrigeration Applications
Compatible mini split air conditioners
Heat-pump systems
Ductless HVAC systems
VRF installations
Split air-conditioning systems
HVACR installation projects
Replacement refrigerant-line projects
Important Checks Before Installation
Confirm Both Copper Tube Sizes
Verify that the HVAC equipment specifically requires 1/2 in. and 3/4 in. refrigerant tubing.
Confirm Each Tube's Function
Confirm the liquid-line, suction-line or other refrigerant-circuit function of each tube from the HVAC equipment manufacturer's piping diagram.
Verify Maximum Piping Length
Confirm that the actual installed refrigerant route remains within the equipment manufacturer's maximum permitted piping length.
Check Minimum Piping Length
Some HVAC systems specify a minimum refrigerant piping length. Confirm this requirement where applicable.
Check Maximum Elevation Difference
Verify the maximum permitted vertical separation between indoor and outdoor HVAC equipment.
Check Refrigerant Charge Requirements
Confirm whether the equipment's factory charge covers the actual installed piping length or whether additional refrigerant is required.
Confirm Communication Cable Compatibility
Confirm conductor count, wire gauge, voltage rating and wiring requirements for the exact HVAC equipment before installation.
Installation Guidelines
Measure the complete refrigerant-line route before installation.
Confirm the required 1/2 in. and 3/4 in. copper tube diameters.
Confirm the function of both refrigerant tubes.
Verify maximum and minimum permitted piping lengths.
Check the maximum permitted elevation difference.
Confirm any additional refrigerant-charge requirement.
Plan the route to avoid unnecessary sharp bends.
Protect the insulation at wall penetrations and support points.
Route the 3 m drain hose according to the equipment installation requirements.
Confirm the included communication cable matches the HVAC equipment.
Inspect the pre-flared ends before connection.
Tighten flare nuts using the equipment manufacturer's specified torque.
Pressure-test and leak-test the completed refrigerant circuit.
Evacuate and commission the system according to the equipment manufacturer's instructions.
B2B Supply for HVACR Wholesalers
DABUND supplies insulated copper tube kits for HVAC contractors, wholesalers, distributors, importers and private-label brands.
Custom insulation thickness, product marking, logo printing and export packaging are available for qualifying OEM and bulk orders.

Insulated Copper Tube Size Options
| Size | Length | Insulation White PE | Flame Resistant |
| 1/4 + 3/8 | 3 m / 4 m / 5 m / 7 m / 10 m | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 | 3 m / 4 m / 5 m / 7 m / 10 m | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 | 3 m / 4 m / 5 m / 7 m / 10 m | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 | 3 m / 4 m / 5 m / 7 m / 10 m | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 | 3 m / 4 m / 5 m / 7 m / 10 m | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 | 3 m / 4 m / 5 m / 7 m / 10 m | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 | 3 m / 4 m / 5 m / 7 m / 10 m | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm | M1 / B1 |
Length Note: This SKU is 50 ft / approximately 15.24 m. The table above shows standard metric lengths available across the wider insulated copper tube range.
Recommended Applications by AC Capacity
| Line Set Size | Common AC Capacity | Typical BTU Range | Typical Application |
| 1/4 + 3/8 | 0.75 ton - 1.0 ton | 9,000 BTU - 12,000 BTU | Small mini split air conditioner |
| 1/4 + 1/2 | 1.5 ton - 2.0 ton | 12,000 BTU - 18,000 BTU | Residential mini split system |
| 1/4 + 5/8 | 2.0 ton - 2.5 ton | 24,000 BTU - 30,000 BTU | Split air conditioner system |
| 3/8 + 5/8 | 3.0 ton - 4.0 ton | 36,000 BTU - 48,000 BTU | Ductless mini split and heat pump |
| 3/8 + 3/4 | 4.5 ton - 6.0 ton | 54,000 BTU - 72,000 BTU | Larger split AC installation |
| 3/8 + 7/8 | 6.0 ton - 8.0 ton | 72,000 BTU - 96,000 BTU | Commercial ductless HVAC systems |
The 1/2 in. x 3/4 in. combination does not have a universal tonnage or BTU mapping. Select this product according to the exact refrigerant-line sizes specified by the HVAC equipment manufacturer.
OEM and Custom Insulated Copper Tube Kits
Multiple copper tube size combinations
Custom finished lengths
White PE and Black Rubber insulation options
Multiple insulation thicknesses
Custom product marking
Company logo printing
Length and size printing
Private-label packaging
Bulk supply for HVAC wholesalers and importers
DABUND Factory
DABUND manufactures insulated copper tubing, mini split line sets, aluminum pipes and related HVAC products for contractors, wholesalers, distributors, importers and private-label customers.

Insulation Test Documentation
Applicable Polypropylene or Black Rubber insulation configurations can be supplied with UV-resistant options and test documentation referencing ASTM E84, UL94, ASTM D1056 and ASTM G21.
White PE is the primary insulation configuration for this product. For projects requiring specific flame, smoke, UV or other compliance documentation, confirm the matching test report for the exact insulation material and thickness ordered.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where buyers can review insulated copper tubing, mini split line sets and related HVAC products.

Frequently Asked Questions
What is the 50 ft 1/2 x 3/4 insulated copper tube used for?
It is used as paired pre-insulated refrigerant tubing for compatible mini split air conditioners, heat pumps, ductless HVAC systems, VRF systems and split AC installations requiring 1/2 in. and 3/4 in. copper tubes.
What does 1/2 x 3/4 mean?
It refers to the outside diameters of the two copper refrigerant tubes. The metric equivalents are approximately 12.7 mm and 19.05 mm.
What AC capacity uses a 1/2 x 3/4 line set?
There is no reliable universal tonnage or BTU mapping for this tube combination. Confirm the exact required refrigerant-line sizes from the HVAC equipment manufacturer's installation manual.
Is this copper tube pre-flared?
Yes. Both copper tube ends are flared and supplied with nuts for compatible HVAC refrigerant connections.
What accessories are included?
The kit includes communication wire cable, a 3 m drain hose, wall pipe, wall cover, flare nuts and installation parts.
What insulation options are available?
White PE and Black Rubber insulation options are available in multiple thicknesses.
Does the copper tubing meet ASTM B280?
The copper tubing is specified to ASTM B280 using C12200 DHP copper.
Is a 50 ft line set suitable for every compatible HVAC system?
No. Confirm the equipment manufacturer's maximum and minimum piping lengths, maximum elevation difference and refrigerant-charge requirements before installation.
Can DABUND customize this insulated copper tube kit?
Yes. DABUND supports custom lengths, insulation thicknesses, product marking, logo printing and private-label packaging for OEM and bulk orders.
Is DABUND a manufacturer?
DABUND manufactures insulated copper tubing, mini split line sets, aluminum pipes and related HVAC products.