Home Copper Pipe Insulated Copper Tube 50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
50 ft 1/2 x 3/4 Insulated Copper Tube Kit
1.Insulated copper pipe including one set air conditioner insulated copper pipe, size 1/2"+3/4"50 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts. 
2. Both of the two copper pipe end do flaring and nuts. 
3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm. 
4. For the insulated copper pipe, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m. 
5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200. 
6.Professional manufacturer of insulated copper pipe, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 10M

Material

99.9% pure copper

Color

Black/White

Keywords

Mini Split Installation Kit

Application

HVAC
Inquire
Add to Basket

50 ft 1/2 in. x 3/4 in. Insulated Copper Tube Kit

The DABUND 50 ft 1/2 in. x 3/4 in. Insulated Copper Tube Kit is a pre-insulated HVAC refrigerant line set and accessory package for compatible mini split air conditioners, heat pumps, ductless HVAC systems, VRF systems and split AC installations.

The kit includes a 50 ft / approximately 15.24 m pair of 1/2 in. and 3/4 in. copper refrigerant tubes with factory-applied White PE insulation, communication wire cable, 3 m drain hose, wall pipe, wall cover, flare nuts and installation accessories.

Both copper tube ends are flared and supplied with nuts to support compatible HVAC refrigerant connections.

Quick Answer: This 1/2 in. x 3/4 in. line-set combination should be selected when the HVAC equipment manufacturer specifically requires these two copper tube diameters. There is no reliable universal tonnage or BTU mapping for the 1/2 x 3/4 combination.

50 ft Insulated Copper Tube Kit Video

Complete HVAC Refrigerant Line Set and Accessories

This product combines insulated copper refrigerant tubing with key installation accessories for compatible HVAC projects.

  • 50 ft / approx. 15.24 m paired copper refrigerant tubing

  • 1/2 in. and 3/4 in. copper tube sizes

  • 12.7 mm and 19.05 mm metric sizes

  • Factory-applied White PE insulation

  • Pre-flared copper tube ends

  • Flare nuts included

  • Communication wire cable included

  • 3 m condensate drain hose included

  • Wall pipe included

  • Wall cover included

  • Additional installation parts included

Key Features

  • 50 ft insulated copper tube kit for compatible HVAC installations

  • 1/2 in. x 3/4 in. paired refrigerant tubing

  • ASTM B280 and C12200 DHP copper specification

  • High-density closed-cell White PE insulation

  • Black Rubber insulation options also available

  • White PE insulation thickness options available

  • Black Rubber insulation thickness options available

  • Pre-flared tube ends with flare nuts

  • 3 m condensate drain hose included

  • Communication wiring cable included

  • Wall pipe and protective wall cover included

  • OEM logo printing and private-label packaging available

Technical Specifications

SpecificationDetail
Product Name50 ft 1/2 in. x 3/4 in. Insulated Copper Tube
Length50 ft / approx. 15.24 m
Line Size1/2 in. x 3/4 in.
Metric Size12.7 mm x 19.05 mm
Copper StandardASTM B280 and C12200 DHP
Insulation MaterialHigh-density closed-cell polyethylene foam / White PE insulation
Insulation OptionsWhite PE and Black Rubber insulation available
Temperature Range-40°C to 120°C
Included AccessoriesWire cable, drain hose, wall pipe, wall cover, flare nuts and installation parts
ApplicationMini split, heat pump, ductless AC, VRF and HVACR installation

1/2 in. x 3/4 in. Refrigerant Tube Size

This product combines 1/2 in. and 3/4 in. copper refrigerant tubes with outside diameters of approximately 12.7 mm and 19.05 mm.

The exact liquid-line and suction-line functions of the two tubes should be confirmed from the HVAC equipment manufacturer's piping diagram.

Do not select this line-set combination using nominal HVAC capacity alone. Required refrigerant-line sizes vary between manufacturers and equipment models.

50 ft Length for HVAC Installation

The 50 ft / approximately 15.24 m tubing length provides additional routing flexibility for compatible residential and light commercial HVAC projects.

A physical 50 ft line set does not mean every HVAC system permits a 50 ft refrigerant run. Confirm the equipment manufacturer's maximum piping length, minimum piping length where applicable, elevation limit and refrigerant-charge requirements before installation.

ASTM B280 and C12200 DHP Copper Tube

The copper tubing is specified to ASTM B280 using C12200 DHP copper for HVAC refrigerant-line applications.

Confirm the required copper tube wall thickness and pressure specification against the HVAC equipment requirements for the exact project.

Pre-Flared Ends with Flare Nuts

Both copper tube ends are flared and supplied with nuts for compatible HVAC refrigerant connections.

Inspect each flare surface before assembly and tighten flare connections using the torque specified by the HVAC equipment manufacturer.

Complete the required pressure testing, leak testing and evacuation before commissioning the refrigerant system.

White PE Insulation

The primary insulation configuration uses high-density closed-cell polyethylene foam with a White PE outer structure.

Thermal Protection

The insulation helps reduce unwanted heat transfer between the copper refrigerant tubing and the surrounding environment.

Condensation Control

The closed-cell structure helps reduce surface condensation and moisture penetration around cold refrigerant tubing.

Temperature Range

Applicable insulation configurations are specified for temperatures from approximately -40°C to 120°C.

UV-Resistant Outer Surface

UV-resistant insulation configurations are available for compatible indoor-to-outdoor HVAC refrigerant-line routes.

White PE and Black Rubber Insulation Options

White PE and Black Rubber insulation options are available for different HVAC market and project requirements.

White PE insulation thickness options include 3/8 in., 1/2 in., 3/4 in., 1 in., 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.

Black Rubber insulation thickness options include 1/2 in., 3/4 in., 1 in., 13 mm, 17 mm, 19 mm and 25.4 mm.

Communication Wire Cable

A communication wire cable is included for compatible indoor-to-outdoor HVAC wiring applications.

Confirm conductor count, wire gauge, voltage rating and equipment compatibility against the exact HVAC model before installation.

3 m Condensate Drain Hose

The kit includes a 3 m condensate drain hose for routing condensate away from the compatible indoor unit.

Install the drain hose with the slope and routing conditions required by the HVAC equipment manufacturer.

Wall Pipe and Wall Cover

The included wall pipe and wall cover are used around the wall penetration where refrigerant tubing, wiring and drain components pass between indoor and outdoor areas.

These components help protect the line set at the penetration point and provide a cleaner finished installation.

Copper Line Set and Insulation Video

99.9 percent pure copper tube for HVAC insulated copper tube

99.9% Pure Copper

White PE insulated copper tube for HVAC line set

White PE Insulated Pipe

copper nut for insulated copper tube kit

Copper Nut

Three-Layer Insulation Structure

Outer Layer: UV-Resistant PE Film

The outer layer uses UV-resistant embossed PE film to provide wear resistance and protection during compatible indoor and outdoor HVAC installations.

Middle Layer: IXPE Foam

The middle layer uses dense-cell IXPE foam for thermal insulation, water resistance and impact protection.

Inner Layer: Closed-Cell Structure

The inner closed-cell structure helps maintain thermal coverage and moisture resistance around the copper tubing.

White PE embossed insulated pipe for 50 ft 1/2 x 3/4 insulated copper tube

Insulation Production and Storage

thermal insulation pipe production for insulated copper tube

Thermal Insulation Pipe Production

warehouse for insulated copper tube

Insulation Pipe Warehouse

inner layer insulated pipe for HVAC copper tube

Inner Layer Insulated Pipe

HVAC and Refrigeration Applications

  • Compatible mini split air conditioners

  • Heat-pump systems

  • Ductless HVAC systems

  • VRF installations

  • Split air-conditioning systems

  • HVACR installation projects

  • Replacement refrigerant-line projects

Important Checks Before Installation

Confirm Both Copper Tube Sizes

Verify that the HVAC equipment specifically requires 1/2 in. and 3/4 in. refrigerant tubing.

Confirm Each Tube's Function

Confirm the liquid-line, suction-line or other refrigerant-circuit function of each tube from the HVAC equipment manufacturer's piping diagram.

Verify Maximum Piping Length

Confirm that the actual installed refrigerant route remains within the equipment manufacturer's maximum permitted piping length.

Check Minimum Piping Length

Some HVAC systems specify a minimum refrigerant piping length. Confirm this requirement where applicable.

Check Maximum Elevation Difference

Verify the maximum permitted vertical separation between indoor and outdoor HVAC equipment.

Check Refrigerant Charge Requirements

Confirm whether the equipment's factory charge covers the actual installed piping length or whether additional refrigerant is required.

Confirm Communication Cable Compatibility

Confirm conductor count, wire gauge, voltage rating and wiring requirements for the exact HVAC equipment before installation.

Installation Guidelines

  1. Measure the complete refrigerant-line route before installation.

  2. Confirm the required 1/2 in. and 3/4 in. copper tube diameters.

  3. Confirm the function of both refrigerant tubes.

  4. Verify maximum and minimum permitted piping lengths.

  5. Check the maximum permitted elevation difference.

  6. Confirm any additional refrigerant-charge requirement.

  7. Plan the route to avoid unnecessary sharp bends.

  8. Protect the insulation at wall penetrations and support points.

  9. Route the 3 m drain hose according to the equipment installation requirements.

  10. Confirm the included communication cable matches the HVAC equipment.

  11. Inspect the pre-flared ends before connection.

  12. Tighten flare nuts using the equipment manufacturer's specified torque.

  13. Pressure-test and leak-test the completed refrigerant circuit.

  14. Evacuate and commission the system according to the equipment manufacturer's instructions.

B2B Supply for HVACR Wholesalers

DABUND supplies insulated copper tube kits for HVAC contractors, wholesalers, distributors, importers and private-label brands.

Custom insulation thickness, product marking, logo printing and export packaging are available for qualifying OEM and bulk orders.

50 ft 1/2 x 3/4 insulated copper tube kit with accessories

Insulated Copper Tube Size Options

SizeLengthInsulation White PEFlame Resistant
1/4 + 3/83 m / 4 m / 5 m / 7 m / 10 m8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mmM1 / B1
1/4 + 1/23 m / 4 m / 5 m / 7 m / 10 m8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mmM1 / B1
1/4 + 5/83 m / 4 m / 5 m / 7 m / 10 m8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mmM1 / B1
3/8 + 5/83 m / 4 m / 5 m / 7 m / 10 m8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mmM1 / B1
3/8 + 3/43 m / 4 m / 5 m / 7 m / 10 m8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mmM1 / B1
1/2 + 3/43 m / 4 m / 5 m / 7 m / 10 m8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mmM1 / B1
3/8 + 7/83 m / 4 m / 5 m / 7 m / 10 m8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mmM1 / B1

Length Note: This SKU is 50 ft / approximately 15.24 m. The table above shows standard metric lengths available across the wider insulated copper tube range.

Recommended Applications by AC Capacity

Line Set SizeCommon AC CapacityTypical BTU RangeTypical Application
1/4 + 3/80.75 ton - 1.0 ton9,000 BTU - 12,000 BTUSmall mini split air conditioner
1/4 + 1/21.5 ton - 2.0 ton12,000 BTU - 18,000 BTUResidential mini split system
1/4 + 5/82.0 ton - 2.5 ton24,000 BTU - 30,000 BTUSplit air conditioner system
3/8 + 5/83.0 ton - 4.0 ton36,000 BTU - 48,000 BTUDuctless mini split and heat pump
3/8 + 3/44.5 ton - 6.0 ton54,000 BTU - 72,000 BTULarger split AC installation
3/8 + 7/86.0 ton - 8.0 ton72,000 BTU - 96,000 BTUCommercial ductless HVAC systems

The 1/2 in. x 3/4 in. combination does not have a universal tonnage or BTU mapping. Select this product according to the exact refrigerant-line sizes specified by the HVAC equipment manufacturer.

OEM and Custom Insulated Copper Tube Kits

  • Multiple copper tube size combinations

  • Custom finished lengths

  • White PE and Black Rubber insulation options

  • Multiple insulation thicknesses

  • Custom product marking

  • Company logo printing

  • Length and size printing

  • Private-label packaging

  • Bulk supply for HVAC wholesalers and importers

DABUND Factory

DABUND manufactures insulated copper tubing, mini split line sets, aluminum pipes and related HVAC products for contractors, wholesalers, distributors, importers and private-label customers.

DABUND factory for 50 ft insulated copper tube production

Insulation Test Documentation

Applicable Polypropylene or Black Rubber insulation configurations can be supplied with UV-resistant options and test documentation referencing ASTM E84, UL94, ASTM D1056 and ASTM G21.

White PE is the primary insulation configuration for this product. For projects requiring specific flame, smoke, UV or other compliance documentation, confirm the matching test report for the exact insulation material and thickness ordered.

SGS certificate for insulated copper tube

International HVAC Exhibitions

DABUND participates in international HVAC exhibitions where buyers can review insulated copper tubing, mini split line sets and related HVAC products.

DABUND HVAC exhibition for insulated copper tube products

Frequently Asked Questions

What is the 50 ft 1/2 x 3/4 insulated copper tube used for?

It is used as paired pre-insulated refrigerant tubing for compatible mini split air conditioners, heat pumps, ductless HVAC systems, VRF systems and split AC installations requiring 1/2 in. and 3/4 in. copper tubes.

What does 1/2 x 3/4 mean?

It refers to the outside diameters of the two copper refrigerant tubes. The metric equivalents are approximately 12.7 mm and 19.05 mm.

What AC capacity uses a 1/2 x 3/4 line set?

There is no reliable universal tonnage or BTU mapping for this tube combination. Confirm the exact required refrigerant-line sizes from the HVAC equipment manufacturer's installation manual.

Is this copper tube pre-flared?

Yes. Both copper tube ends are flared and supplied with nuts for compatible HVAC refrigerant connections.

What accessories are included?

The kit includes communication wire cable, a 3 m drain hose, wall pipe, wall cover, flare nuts and installation parts.

What insulation options are available?

White PE and Black Rubber insulation options are available in multiple thicknesses.

Does the copper tubing meet ASTM B280?

The copper tubing is specified to ASTM B280 using C12200 DHP copper.

Is a 50 ft line set suitable for every compatible HVAC system?

No. Confirm the equipment manufacturer's maximum and minimum piping lengths, maximum elevation difference and refrigerant-charge requirements before installation.

Can DABUND customize this insulated copper tube kit?

Yes. DABUND supports custom lengths, insulation thicknesses, product marking, logo printing and private-label packaging for OEM and bulk orders.

Is DABUND a manufacturer?

DABUND manufactures insulated copper tubing, mini split line sets, aluminum pipes and related HVAC products.

Related Products

1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 3/8" x 3/4" is the out dimension in inch. 9.52mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 3/8" x 3/4" is the out dimension in inch. 9.52mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.