3/8" x 3/4" Mini Split Line Set
DABUND 3/8" x 3/4" Mini Split Line Set combines two insulated copper tubes for compatible split air conditioning, heat pump and HVACR installations.
The copper tube outside diameters are 3/8" and 3/4", equivalent to approximately 9.52 mm and 19.05 mm. Current product information identifies the copper tubing as ASTM B280 / C12200 DHP and primarily presents Black Rubber insulation.
Available production lengths listed for this product range include 15 m, 20 m, 25 m, 30 m and 50 m, providing multiple coil-length options for HVAC distributors, contractors and project buyers.
Quick Answer: This page covers the 3/8" x 3/4" insulated copper line set size rather than one fixed length. The listed range includes 15–50 m coils with multiple insulation thickness options.
Compatibility Notice: Confirm that the exact HVAC equipment requires 3/8" and 3/4" refrigerant tubing before ordering. Similar-capacity systems can require different liquid-line and suction-line dimensions.
3/8" x 3/4" Mini Split Line Set Specifications
| Product Type | Pre-Insulated Copper Mini Split Line Set |
| Copper Tube Size | 3/8" + 3/4" |
| Metric Outside Diameter | Approx. 9.52 mm + 19.05 mm |
| Copper Specification | ASTM B280 / C12200 DHP according to current product information |
| Primary Displayed Insulation | Black Rubber |
| Available Lengths | 15 m / 20 m / 25 m / 30 m / 50 m |
| Insulation Thickness Options | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm according to configuration |
| Listed Temperature Range | Selected insulation configurations: approximately -40°C to 120°C |
| Applications | Compatible split AC, heat pump and HVACR systems |
| OEM Printing | Company name, size and length markings can be discussed according to order requirements |
Key Features of 3/8" x 3/4" Insulated Copper Line Set
9.52 mm and 19.05 mm Copper Tube Pair
The nominal 3/8" and 3/4" copper tube outside diameters correspond to approximately 9.52 mm and 19.05 mm.
These dimensions must match the refrigerant piping requirements specified by the indoor and outdoor HVAC equipment.
ASTM B280 / C12200 Copper Tubing
Current product information identifies the copper tubing as C12200 DHP copper and references ASTM B280 for HVAC and refrigeration copper tube applications.
Multiple Coil Lengths from 15 m to 50 m
Listed production lengths include 15 m, 20 m, 25 m, 30 m and 50 m, allowing professional buyers to choose coil lengths according to project and inventory requirements.
Paired Insulated Copper Tubes
The two insulated copper tubes are supplied together as a paired line set for organized transportation, storage and installation.
OEM Identification Printing
DABUND can discuss customized insulation printing such as company name, copper tube size and length identification for OEM and private-label orders.

Copper Refrigerant Tubing

Black Rubber Insulation

Protective Plastic Cap
Black Rubber Pipe Insulation
The current 3/8" x 3/4" product page primarily presents Black Rubber insulated tubing. Closed-cell insulation is designed to reduce unwanted heat transfer and help control condensation around refrigerant copper piping.
Thermal Insulation
The closed-cell insulation structure helps reduce heat transfer between the refrigerant piping and surrounding air.
Condensation Control
Properly installed insulation helps limit moisture penetration and reduce surface condensation around refrigerant copper tubing.
Temperature Range
Current product information lists selected insulation configurations with an approximate temperature range from -40°C to 120°C. Confirm the exact material specification for the ordered configuration.
Available Insulation Testing
Current product information references ASTM E84, UL 94, ASTM D1056, ASTM G21, ASTM C1427 and UL 723 for selected insulation configurations. Buyers should confirm which reports and standards apply to the exact material being ordered.

3/8" x 3/4" Black Rubber Copper Line Set
The 3/8" x 3/4" configuration provides paired insulated copper tubing for compatible HVAC installations requiring approximately 9.52 mm and 19.05 mm outside-diameter refrigerant lines.
Some higher-capacity split HVAC systems may use this pipe combination, but pipe sizing varies between equipment manufacturers and models. Confirm the required dimensions from the equipment technical documentation before ordering.

Available Mini Split Line Set Sizes
The broader product range includes multiple copper tube combinations, coil lengths and insulation thickness options. The table below preserves the size information from the original product page.
| Size | Length | Insulation Thickness | Listed Flame-Resistant Options |
| 1/4 + 3/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 1/2 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 5/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 5/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 3/4 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/2 + 3/4 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 7/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
How to Select a 3/8" x 3/4" Mini Split Line Set
Confirm Both Refrigerant Pipe Sizes
Verify that the HVAC equipment requires 3/8" and 3/4" outside-diameter copper tubing. Do not select a line set only from nominal system capacity.
Select the Required Coil Length
Available listed lengths include 15 m, 20 m, 25 m, 30 m and 50 m. Choose a coil length according to project requirements and the equipment manufacturer's permitted piping length.
Check Maximum Actual and Equivalent Piping Length
For longer installations, confirm the maximum actual refrigerant piping length and any equivalent-length calculations required by the equipment manufacturer.
Check Vertical Separation
Where indoor and outdoor units are installed at different elevations, verify the maximum permitted vertical separation specified for the exact HVAC system.
Confirm Refrigerant Charging Requirements
Some HVAC systems include a factory refrigerant charge for only a specified standard piping length. Follow the equipment manufacturer's instructions to determine whether additional refrigerant is required.
Confirm Copper Wall Thickness and Pressure Requirements
Allowable working and test pressure depends on copper tube diameter, wall thickness, material specification and product configuration. Confirm the technical data for the exact line set rather than applying one pressure value to all tubing sizes.
Is 3/8" x 3/4" Compatible With My HVAC System?
The 3/8" x 3/4" combination is used by selected split air conditioning and heat pump systems, including some higher-capacity equipment.
The original product information associates this size with some systems in approximately 54,000–72,000 BTU classes, but this should be treated only as a general reference rather than a universal sizing rule.
Always confirm the required liquid-line and suction-line dimensions from the exact HVAC equipment manufacturer's installation manual.
Applications
The 3/8" x 3/4" insulated copper line set can be used with compatible HVAC and refrigeration equipment where these exact refrigerant piping dimensions are specified.
Compatible split air conditioning systems
Compatible ductless HVAC equipment
Compatible heat pump systems
Commercial HVAC installations
HVACR project piping
Distributor and contractor supply
For HVAC Distributors and Project Buyers
DABUND supplies insulated copper line sets to HVAC distributors, wholesalers, importers, contractors and project suppliers requiring different copper tube combinations, coil lengths and insulation configurations.
The 3/8" x 3/4" page functions as a size-specific purchasing reference, with multiple coil lengths available for distribution inventory and project requirements.
OEM and Custom Mini Split Line Sets
DABUND supports OEM and ODM supply according to the required insulated copper line-set configuration.
Multiple copper tube combinations
15 m, 20 m, 25 m, 30 m and 50 m listed coil lengths
Multiple insulation thickness options
Company-name printing
Pipe-size identification
Length or meter marking
Private-label requirements
Why Choose DABUND Mini Split Line Sets?
HVAC Manufacturing Experience Since 2008
DABUND has manufactured HVAC components since 2008, supplying insulated copper tubing, mini split line sets and related HVAC products to international customers.
Multiple Copper Sizes and Coil Lengths
The product range includes multiple copper tube combinations and coil lengths for different distribution and installation requirements.
Custom Identification for B2B Orders
Product identification and printing requirements can be discussed for OEM, distributor and private-label orders.
DABUND Factory and Export Packaging
DABUND supplies insulated copper pipe, mini split line sets and related HVAC components for international B2B customers.

Insulation Testing and Product Documentation
Current product information references ASTM E84, UL 94, ASTM D1056 and ASTM G21 for selected insulation configurations. Applicable reports and material scope should be confirmed for the exact product being ordered.

International HVAC Exhibitions
DABUND participates in international exhibitions to present mini split line sets, insulated copper tubing and related HVAC products to distributors and professional buyers.

Frequently Asked Questions
What size is the 3/8" x 3/4" mini split line set in millimeters?
The nominal outside diameters are approximately 9.52 mm for the 3/8" tube and 19.05 mm for the 3/4" tube.
What copper specification is used?
Current product information identifies the copper tubing as C12200 DHP and references ASTM B280.
What lengths are available for the 3/8" x 3/4" line set?
Listed production lengths include 15 m, 20 m, 25 m, 30 m and 50 m.
What insulation is used on this line set?
The current product page primarily presents Black Rubber insulated tubing. Other insulation configurations appear in the broader product range and should be confirmed when ordering.
What insulation thicknesses are available?
Current product information lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options according to configuration.
What HVAC capacity commonly uses a 3/8" x 3/4" line set?
The original product information associates this pipe combination with some systems around 54,000–72,000 BTU. This is only a general reference because actual refrigerant pipe sizing varies by equipment manufacturer and model.
Can I choose a 3/8" x 3/4" line set only by BTU?
No. Confirm the required refrigerant pipe outside diameters in the equipment manufacturer's installation manual before ordering.
Is the 3/8" x 3/4" line set suitable for every mini split system?
No. Different HVAC systems require different refrigerant pipe dimensions, wall thicknesses and installation conditions.
Can a 50 m coil be used on any system that requires 3/8" x 3/4" tubing?
Not automatically. Even when the tube diameters match, the HVAC equipment manufacturer may limit maximum actual piping length, equivalent length and vertical separation.
Does a longer refrigerant line require additional refrigerant?
It may. Refrigerant charging requirements depend on the factory-charge allowance and piping-length instructions for the exact HVAC equipment.
What pressure can the 3/8" x 3/4" copper tubing handle?
Allowable working and test pressure depends on copper tube diameter, wall thickness, material specification and the selected product configuration. Confirm the technical data for the exact tubing being ordered.
Can DABUND print my company name on the insulation?
Yes. Current product information states that company name, tube size, length and related identification can be printed according to order requirements.
Can I get samples before placing a bulk order?
Yes. According to the current product information, DABUND can provide three sample pieces, with the buyer covering express shipping costs. View sample information.
What payment terms are available?
Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.
What delivery terms are available?
Available international trade terms can include EXW, FOB, CFR and CIF.
What is the typical delivery time?
Current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on order quantity, product specification, customization and production schedule.