75 ft 1/2 in. x 3/4 in. Pre-Insulated Copper Pipe
DABUND 75 ft 1/2 in. x 3/4 in. Pre-Insulated Copper Pipe provides an extended refrigerant piping solution for compatible commercial air-conditioning, heat-pump, HVAC and refrigeration installations.
The paired copper tubing combines a 1/2 in. liquid line with a 3/4 in. suction line and provides a continuous 75 ft length, approximately 22.86 m, for projects requiring greater separation between indoor and outdoor equipment.
Manufactured from 99.9% pure copper with ASTM B280 / C12200 referenced in the source product information, the tubing is supplied with factory-applied insulation for professional HVAC and refrigeration piping applications.
Quick Answer: This 75 ft 1/2 x 3/4 pre-insulated copper line set combines high-purity copper tubing with factory insulation for compatible long-distance HVAC and refrigeration installations. Final equipment compatibility should be confirmed from the manufacturer's specified pipe sizes and piping limits.
75 ft Pre-Insulated Copper Pipe Video
75 ft 1/2 x 3/4 Copper Pipe Specifications
| Brand | DABUND |
| Product Type | Pre-Insulated Copper Refrigerant Line Set |
| Pipe Size | 1/2 in. + 3/4 in. |
| Liquid Line | 1/2 in. / 12.70 mm |
| Suction Line | 3/4 in. / 19.05 mm |
| Length | 75 ft / approximately 22.86 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 referenced in source product information |
| Featured Insulation | Black Rubber shown in the product images and family table |
| Other Source-Listed Insulation | Polypropylene / PE and PE / IXPE configurations are also referenced on the page |
| Listed Temperature Range | -40°C to 120°C; confirm applicability to the selected insulation configuration |
| Source-Listed Pressure Range | 2100–7000 PSI; applicable rating depends on tube dimensions and wall thickness |
| Listed Refrigerant | R410A is specifically referenced; final compatibility must follow equipment requirements |
| Applications | Compatible HVAC / Air Conditioning / Refrigeration Systems |
What Is a 75 ft Pre-Insulated Copper Line Set?
A 75 ft pre-insulated copper line set provides paired refrigerant piping for compatible HVAC systems where the indoor and outdoor equipment are separated by a longer-than-standard routing distance.
This product combines a 1/2 in. liquid line, a 3/4 in. suction line and factory-applied insulation in a continuous 75 ft coil.
Typical layouts may include large residential properties, commercial buildings, rooftop equipment and compatible refrigeration projects requiring extended copper piping.
75 ft Length for Extended HVAC Installations
The 75 ft / 22.86 m continuous coil provides additional installation flexibility where indoor and outdoor HVAC equipment cannot be positioned close together.
Using a continuous refrigerant piping run can reduce unnecessary intermediate joints, provided the installed route remains within the HVAC equipment manufacturer's permitted piping limits.
Long refrigerant runs require careful verification of maximum piping length, maximum elevation difference and additional refrigerant charging requirements before installation.
1/2 in. Liquid Line and 3/4 in. Suction Line
This configuration combines a 1/2 in. liquid refrigerant line with a 3/4 in. suction return line.
Before ordering, verify that the selected air-conditioning, heat-pump or refrigeration equipment specifically requires these exact copper tube diameters.
Required refrigerant pipe dimensions vary by equipment manufacturer and model, so the equipment specification should always take priority over general capacity-based selection.
99.9% Pure Copper with ASTM B280 / C12200
The source product information specifies 99.9% pure copper and references ASTM B280 and C12200 for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC and refrigeration piping systems.
Suitable HVAC tube-bending methods and appropriate bend radii should be used to reduce the risk of kinking, flattening or restricting refrigerant flow.
Pressure Capability and Refrigerant Applications
The source product information lists a pressure range of 2100–7000 PSI and specifically references R410A refrigerant applications.
Actual allowable working pressure depends on tube diameter, copper wall thickness, operating temperature and exact product configuration. Confirm the applicable technical specification before selecting the tubing for a specific HVAC system.
Insulation Options for HVAC Refrigerant Piping
The current product page references several insulation configurations. The product photographs and wider product-family table prominently show Black Rubber insulation, while another technical section references Polypropylene / PE.
Buyers should therefore confirm the exact insulation material, thickness, flame-resistance requirement and outdoor exposure requirement when placing an order.
Black Rubber Insulation
The featured product images show Black Rubber insulated copper tubing. The source information lists a temperature range of approximately -40°C to 120°C for this insulation description.
PE / Polypropylene Insulation Options
PE and Polypropylene insulation are also referenced in the technical specification. Confirm the exact construction when these materials are required for a project.
Copper Line Set and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Protective Plastic Cap
Black Rubber Insulation Detail
Black Rubber insulation acts as both a thermal layer and moisture-resistant barrier around the copper refrigerant piping.
A closed-cell insulation structure helps reduce water-vapor penetration and condensation around cold refrigerant lines.

Applications
Commercial HVAC Systems
Suitable for compatible commercial air-conditioning systems requiring a 1/2 in. liquid line and 3/4 in. suction line.
Large Residential HVAC Systems
The 75 ft length can provide additional routing flexibility in larger residential properties when the selected HVAC equipment permits the required piping distance.
Rooftop HVAC Installations
Extended piping can support compatible projects where outdoor equipment is installed on a roof or at another remote location.
Refrigeration Systems
Refrigeration is listed as an application in the technical specification. Final tubing size, pressure and refrigerant suitability must be confirmed for the specific refrigeration equipment.
Important Checks for a 75 ft Refrigerant Run
Verify Maximum Permitted Piping Length
Confirm that the selected HVAC equipment permits at least the required 75 ft refrigerant piping route.
Confirm the Exact Pipe Diameters
Verify that the equipment specifically requires a 1/2 in. liquid line and 3/4 in. suction line.
Check Maximum Elevation Difference
For multi-story and rooftop installations, confirm the maximum permitted vertical separation between indoor and outdoor equipment.
Check Additional Refrigerant Charge
A 75 ft installation may require additional refrigerant beyond the equipment's factory charge. Follow the equipment manufacturer's charging instructions for the actual installed piping length.
Provide Proper Pipe Support
Use suitable HVAC-rated supports, clips or straps to reduce sagging, vibration and mechanical stress along the refrigerant piping route.
Installation Guidelines
Plan the Complete Piping Route
Measure and plan the complete piping route before uncoiling or cutting the copper tubing.
Avoid Sharp Bends and Kinks
Use appropriate tube-bending tools and suitable bend radii to reduce the risk of tube deformation and restricted refrigerant flow.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation, especially around bends, supports and wall penetrations.
Keep Copper Tube Ends Protected
Keep open copper tube ends sealed during storage and installation to reduce moisture and contamination entering the refrigerant piping.
Pressure Test and Evacuate Before Startup
Follow the equipment manufacturer's pressure-testing, evacuation, refrigerant charging and commissioning procedures before startup.

Available Pre-Insulated Copper Pipe Sizes
| Size | Available Lengths | Black Rubber Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific product is 75 ft / approximately 22.86 m. The wider product-family table lists 20 m and 25 m as adjacent standard production lengths, so buyers should specify the required finished 75 ft configuration when ordering.
Line Set Size Selection
DABUND supplies multiple refrigerant-line size combinations for different HVAC equipment requirements. The exact liquid-line and suction-line dimensions should be selected from the equipment manufacturer's technical documentation.
| Available Size | Selection Guidance |
|---|
| 1/4 + 3/8 in. | Confirm exact OEM equipment requirement |
| 1/4 + 1/2 in. | Confirm exact OEM equipment requirement |
| 1/4 + 5/8 in. | Confirm exact OEM equipment requirement |
| 3/8 + 5/8 in. | Confirm exact OEM equipment requirement |
| 3/8 + 3/4 in. | Confirm exact OEM equipment requirement |
| 1/2 + 3/4 in. | This product; confirm equipment-specific compatibility |
| 3/8 + 7/8 in. | Confirm exact OEM equipment requirement |
DABUND Manufacturing and OEM Capabilities
Production Capacity
The source product information states that DABUND operates two factories and supports ongoing bulk production for HVAC distributors and project customers.
OEM and ODM Customization
International Supply
DABUND supplies insulated copper pipe and related HVAC products to international distributors, contractors and project customers.
Packaging and Delivery
Standard export packaging
Customized packaging available
Source-listed delivery time: approximately 15–20 days
Final production and delivery time should be confirmed according to order quantity, insulation configuration, packaging and customization requirements.
DABUND Pre-Insulated Copper Pipe Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC components for distributors, contractors and project buyers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations reference ASTM E84, UL94, ASTM D1056 and ASTM G21.
Buyers requiring project-specific compliance documents should confirm the exact insulation material, insulation thickness and corresponding test report for the ordered configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review insulated copper piping, line sets and related HVAC products.

Frequently Asked Questions
What is a 75 ft 1/2 x 3/4 pre-insulated copper line set used for?
It is used as refrigerant piping between compatible HVAC or refrigeration equipment requiring a 1/2 in. liquid line and 3/4 in. suction line.
How long is this pre-insulated copper pipe?
The product is 75 ft long, approximately 22.86 m.
What HVAC capacity is a 1/2 x 3/4 line set suitable for?
Capacity cannot be determined reliably from pipe size alone. Confirm the exact 1/2 in. liquid-line and 3/4 in. suction-line requirement from the HVAC equipment manufacturer's technical documentation.
Can every compatible system use a 75 ft refrigerant run?
No. Confirm the equipment manufacturer's maximum permitted piping length, maximum elevation difference and refrigerant charging requirements before installation.
Does a 75 ft line set require additional refrigerant?
Additional refrigerant may be required depending on the equipment's factory charge and total installed piping length. Follow the manufacturer's charging instructions.
What copper material is used?
The source technical specification lists 99.9% pure copper and references ASTM B280.
What insulation material is used?
The current page references multiple insulation configurations. Product images and the family table show Black Rubber, while the technical specification also lists Polypropylene / PE. Confirm the exact insulation material for the ordered SKU.
What insulation thicknesses are available?
The wider Black Rubber product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thicknesses.
What is the listed temperature range?
The source technical specification lists approximately -40°C to 120°C. Confirm that the rating applies to the exact insulation configuration ordered.
What is the pressure rating?
The source page lists a pressure range of 2100–7000 PSI. The applicable rating depends on tube diameter, wall thickness, temperature and the exact copper configuration.
Is R410A supported?
R410A is specifically referenced in the source product information. Final compatibility must still be confirmed against the HVAC equipment manufacturer's piping and pressure requirements.
Is the insulation suitable for outdoor installation?
UV-resistant insulation is referenced in the source page. Final outdoor suitability should be confirmed for the exact insulation material and exposure conditions.
Can the 75 ft copper tubing be shortened?
The tubing can be shortened when suitable HVAC cutting, deburring and connection procedures are used according to the equipment manufacturer's installation requirements.
Can DABUND customize the line set?
Yes. The source product information lists logo printing, custom insulation thickness and customized packaging as OEM and ODM options.
Is DABUND a manufacturer?
Yes. The source page identifies DABUND as a manufacturer of insulated copper pipe, mini split line sets and related HVAC components.
Can I request free samples?
The source page states that up to three free samples can be supplied for qualified requests, with express freight paid by the buyer. View Sample Information
What payment terms are available?
Listed payment options include T/T, L/C at sight and credit card.
What delivery terms are available?
Listed delivery terms include EXW, FOB, CFR and CIF.
What is the typical delivery time?
The source product information lists approximately 15–20 days, depending on order quantity and customization requirements.