35 ft 1/4 in. x 3/8 in. AC Installation Kit
DABUND 35 ft 1/4 in. x 3/8 in. AC Installation Kit provides the main components required for compatible ductless mini split air conditioner and heat-pump installations.
The kit combines a 35 ft insulated copper refrigerant line set with communication wire, a 3 m drain hose, wall sleeve, wall cover and related installation accessories.
The refrigerant tubing uses a 1/4 in. liquid line and 3/8 in. suction line made from 99.9% pure copper, with ASTM B280 / C12200 referenced in the source product information.
Quick Answer: This 35 ft 1/4 x 3/8 mini split installation kit combines insulated copper tubing, communication wire, drain hose, wall sleeve, cover and installation accessories for compatible HVAC systems requiring this exact pipe size.
AC Installation Kit Video
What Is Included in the 35 ft AC Installation Kit?
| Insulated Copper Line Set | 1/4 in. + 3/8 in., 35 ft / approximately 10.67 m |
| Liquid Line | 1/4 in. / 6.35 mm |
| Suction Line | 3/8 in. / 9.52 mm |
| Communication Wire | Included according to the source kit configuration |
| Drain Hose | 3 m |
| Wall Sleeve Pipe | Included |
| Wall Cover | Included |
| Installation Accessories | Included according to the source package description |
The exact communication-wire specification, wall-sleeve dimensions and accessory quantities should be confirmed for the ordered kit configuration.
Technical Specifications
| Product Type | Complete Mini Split AC Installation Kit |
| Line Set Size | 1/4 in. + 3/8 in. |
| Length | 35 ft / approximately 10.67 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 |
| Connection | Pre-Flared Ends with Nuts |
| Featured Insulation | White PE shown in product images and family table |
| Alternative Insulation | Black Rubber is also listed as an available option |
| Insulation Thickness Options | 8 / 9 / 10 / 13 / 19 / 25.4 mm shown in the family table |
| General Capacity Reference | 0.75–1.0 Ton / 9,000–12,000 BTU |
| Applications | Compatible Mini Split AC / Heat Pump / Ductless HVAC Systems |
Complete Mini Split Installation Package
This product is supplied as an AC installation-kit configuration rather than insulated copper tubing alone.
Combining the refrigerant piping with communication wire, condensate drain hose and wall-entry components can simplify procurement for HVAC contractors, distributors and project buyers.
1/4 in. Liquid Line and 3/8 in. Suction Line
The refrigerant line set combines a 1/4 in. liquid line with a 3/8 in. suction return line.
Buyers should verify that the selected mini split or heat-pump model specifically requires these exact refrigerant-line diameters before ordering.
Nominal BTU capacity should only be used as an initial reference because required line sizes vary between HVAC manufacturers and equipment models.
General 9,000–12,000 BTU Capacity Reference
The wider DABUND product family lists the 1/4 in. + 3/8 in. configuration as a general reference for some 0.75–1.0 ton mini split systems.
The corresponding family reference is approximately 9,000–12,000 BTU.
These capacity values are general references only. Final line-set sizing must follow the HVAC equipment manufacturer's exact pipe-size requirements.
ASTM B280 C12200 Copper Refrigerant Tubing
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200 for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible air-conditioning and refrigeration piping applications.
Pre-Flared Copper Ends with Nuts
The source page states that both ends of the copper tubing are pre-flared and supplied with nuts for connection to compatible equipment.
Pre-flared ends can reduce field preparation when the flare geometry and nut sizes match the HVAC equipment.
Installers should inspect each flare before connection and tighten flare nuts according to the HVAC equipment manufacturer's specified torque requirements.
White PE and Black Rubber Insulation Options
The source page lists both White PE and Black Rubber insulation configurations for different project requirements.
White PE Insulation
White PE is the insulation configuration prominently shown in the product images and the wider AC installation-kit family table on this page.
The source describes White PE as available in multiple insulation thicknesses from 8 mm to 25.4 mm.
Black Rubber Insulation
Black Rubber insulation is also listed as an option for projects requiring a different insulation configuration.
Buyers should confirm the exact insulation material, thickness, color and compliance requirements for the ordered kit.
Three-Layer White PE Insulation Structure
The source page describes a three-layer insulation structure for the White PE configuration.
Outer Layer
UV-resistant embossed PE film is referenced as the protective outer layer.
Middle Layer
High-density IXPE foam is referenced for thermal insulation, cushioning and moisture resistance.
Inner Layer
A closed-cell inner insulation structure is referenced for thermal protection around the copper tubing.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Copper Nut
White PE Embossed Insulation

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
Compatible HVAC Applications
Compatible ductless mini split air conditioners
Heat-pump systems
Residential HVAC installations
Light commercial HVAC projects requiring this pipe size
Compatible refrigeration applications
Final compatibility must be confirmed from the equipment manufacturer's required liquid-line diameter, suction-line diameter, refrigerant, electrical requirements and permitted piping length.
35 ft Length for Flexible Installation Routes
The 35 ft line set equals approximately 10.67 m and provides routing flexibility for compatible installations where indoor and outdoor equipment are moderately separated.
Before installation, verify that the selected HVAC equipment permits the proposed piping length and remains within the manufacturer's minimum and maximum refrigerant-line limits.
OEM and Customization Services
Custom line-set lengths
Custom insulation thickness
White PE or Black Rubber insulation options
Logo printing
Private-label packaging
Bulk supply for wholesalers and distributors
OEM and ODM configurations
Complete AC Installation Kit

Available AC Installation Kit Sizes
| Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 35 ft / approximately 10.67 m. The wider family table lists 10 m as the closest standard metric configuration, so buyers should specify the exact finished 35 ft kit when ordering.
General Line Set Size and Capacity Reference
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
These capacity values are general product-family references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact requirements.
Important Checks Before Installation
Confirm Exact Refrigerant Pipe Sizes
Verify that the selected HVAC equipment specifically requires a 1/4 in. liquid line and 3/8 in. suction line.
Verify Permitted Piping Length
Confirm that the equipment manufacturer permits the proposed 35 ft refrigerant piping route.
Check Maximum Elevation Difference
If the indoor and outdoor units are installed at different elevations, confirm the manufacturer's maximum permitted vertical separation.
Check Refrigerant Charge Requirements
Confirm whether a 35 ft run falls within the equipment's factory refrigerant-charge allowance and follow the manufacturer's charging instructions.
Confirm Communication Wire Specification
Verify that the supplied communication wire matches the electrical and communication requirements of the selected HVAC equipment.
Confirm Drain Hose Routing
Plan the condensate drain route with suitable slope and follow the indoor-unit manufacturer's drainage requirements.
Installation Guidelines
Inspect the Pre-Flared Connections
Inspect each copper flare before connection and tighten flare nuts according to the HVAC equipment manufacturer's specified torque.
Avoid Sharp Bends
Use appropriate HVAC tube-bending methods and suitable bend radii to reduce the risk of tube deformation or restricted refrigerant flow.
Secure the Line Set Properly
Use suitable clamps or supports to reduce vibration and mechanical stress along the installed refrigerant piping route.
Protect Wall Entry Points
Use the wall sleeve and suitable protection where the line set passes through the building structure to reduce damage to the insulation and copper tubing.
Pressure Test and Evacuate Before Startup
Refrigerant piping should be leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.
DABUND HVAC Installation Kit Factory
DABUND manufactures insulated copper pipe, mini split line sets and related HVAC components for distributors, contractors and project buyers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations reference ASTM E84, UL94, ASTM D1056 and ASTM G21.
Because the featured configuration on this page is White PE, buyers requiring compliance documentation should confirm the exact White PE insulation material, thickness and corresponding test report for the ordered kit.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review AC installation kits, insulated copper line sets and related HVAC products.

Frequently Asked Questions
What is included in the 35 ft AC installation kit?
The source kit includes a 35 ft 1/4 x 3/8 insulated copper line set, communication wire, 3 m drain hose, wall sleeve, wall cover and installation accessories.
How long is the copper line set?
The copper line set is 35 ft long, approximately 10.67 m.
What size mini split can use a 1/4 x 3/8 line set?
The wider DABUND product family lists 1/4 x 3/8 as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU systems. Final tubing size must follow the HVAC equipment manufacturer's exact specification.
Are the copper tubes pre-flared?
Yes. The source page states that both ends of the copper tubing are pre-flared and supplied with nuts.
What copper material is used?
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200.
What insulation options are available?
The source page lists both White PE and Black Rubber insulation options. White PE is the configuration prominently shown in the product images and AC installation-kit family table.
What insulation thicknesses are available?
The wider White PE family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
Does the kit include communication wire?
Yes. Communication wire is listed as part of the source kit configuration. Confirm the conductor specification and compatibility with the selected HVAC equipment.
Does the kit include a drain hose?
Yes. The source page lists a 3 m drain hose as part of the kit.
Does the kit include a wall sleeve and cover?
Yes. A wall sleeve pipe and cover are listed as part of the source package.
Can this installation kit be used with heat pumps?
Heat-pump systems are listed as an application. Final compatibility depends on the equipment manufacturer's required pipe sizes, electrical specification and installation requirements.
Is 35 ft suitable for every mini split installation?
No. Confirm the equipment manufacturer's minimum and maximum permitted piping lengths, elevation limits and refrigerant-charge requirements before installation.
Can DABUND customize the AC installation kit?
Yes. The source page lists custom lengths, insulation thickness, private-label packaging, logo printing and bulk-order options.
Is professional HVAC installation recommended?
Yes. Refrigerant piping, electrical wiring, condensate drainage, leak testing, evacuation and system commissioning should follow the HVAC equipment manufacturer's instructions and applicable local requirements.