35 Ft 1/4" x 3/8" Mini Split Installation Kit
DABUND 35 ft 1/4" x 3/8" Mini Split Installation Kit combines pre-insulated copper refrigerant tubing with commonly required installation accessories for compatible ductless mini split air conditioners and heat pump systems.
The kit includes a 35 ft / approximately 10.67 m pair of 1/4" and 3/8" copper tubing, communication wire cable, a 3 m drain hose, wall pipe and wall cover. Both ends of the copper tubing are flared and supplied with nuts.
The copper tube outside diameters are approximately 6.35 mm and 9.52 mm. On compatible HVAC equipment, the 1/4" tube commonly functions as the liquid refrigerant line while the 3/8" tube commonly functions as the suction or gas return line.
The current product description specifies 1/2" White PE insulation. Black Rubber insulation and multiple insulation thickness options are also available according to the ordered configuration.
Quick Answer: This is a 35 ft / approximately 10.67 m complete mini split installation kit with 1/4" and 3/8" insulated copper tubing, flared ends with nuts, communication cable, drain hose, wall pipe and wall cover for compatible HVAC installations.
Compatibility Notice: Confirm the required refrigerant pipe dimensions, allowable piping length, connection size, communication cable specification and condensate drain arrangement for the exact indoor and outdoor equipment before ordering.
What Is Included in the 35 Ft Mini Split Installation Kit?
| Insulated Copper Tubing | 1/4" + 3/8", 35 ft / approx. 10.67 m |
| Copper Tube Ends | Flared ends with nuts |
| Communication Wire Cable | Included according to kit configuration |
| Drain Hose | 3 m |
| Wall Pipe | Included |
| Wall Cover | Included |
| Current Insulation | 1/2" White PE according to current product description |
35 Ft 1/4" x 3/8" Mini Split Kit Specifications
| Brand | DABUND |
| Product Type | Complete Mini Split Installation Kit |
| Copper Tube Size | 1/4" + 3/8" |
| Metric Outside Diameter | Approx. 6.35 mm + 9.52 mm |
| Common Line Function | 1/4" liquid line + 3/8" suction/gas line on compatible equipment |
| Length | 35 ft / approx. 10.67 m |
| Copper Material | C12200 DHP according to specification |
| Copper Tube Standard | ASTM B280 specification available |
| Primary Insulation | 1/2" White PE |
| White PE Thickness Options | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm according to configuration |
| Black Rubber Options | 13 mm / 17 mm / 19 mm / 25.4 mm according to configuration |
| Drain Hose | 3 m |
| Applications | Compatible mini split AC and heat pump installations |
| OEM / ODM | Available according to ordered configuration |
Key Features of the 35 Ft Mini Split Installation Kit
1/4" and 3/8" Refrigerant Copper Tubing
The kit contains paired 1/4" and 3/8" copper refrigerant tubing. On compatible HVAC systems, the smaller 1/4" tube commonly serves as the liquid line while the larger 3/8" tube commonly serves as the suction or gas return line.
35 Ft / 10.67 m Installation Length
The 35 ft copper line provides approximately 10.67 m of refrigerant piping. It provides additional routing distance compared with 20 ft, 25 ft and 30 ft kits while remaining shorter than a 50 ft extended installation kit.
Pre-Flared Ends With Nuts
Both copper tube ends are supplied with flared connections and nuts, reducing field preparation where the supplied connection dimensions match the HVAC equipment.
Communication Cable Included
Communication wire cable is included according to the selected kit configuration. Confirm conductor count, wire size and connection requirements against the exact equipment wiring diagram.
Drain Hose, Wall Pipe and Wall Cover
A 3 m drain hose, wall pipe and wall cover are included to support condensate drainage and routing of refrigerant tubing and wiring through the building wall.
White PE Insulated Copper Tubing
The current product configuration uses 1/2" White PE insulation. The insulation helps reduce heat transfer and provides a protective layer around the refrigerant copper tubing.

Copper Refrigerant Tubing

White PE Insulated Pipe

Flared Ends With Nuts
White PE Insulation Structure
The displayed White PE insulation uses a multi-layer structure designed to provide thermal insulation and physical protection around the copper refrigerant tubing.


Insulation Pipe Production

Insulated Pipe Warehouse

Inner Insulation Layer
Embossed PE Outer Layer
The outer layer uses embossed PE film designed to provide surface protection, wear resistance and resistance to aging conditions.
Dense-Cell Foam Middle Layer
The middle layer uses dense-cell foam designed to provide thermal insulation, impact absorption and resistance to water penetration.
Closed-Cell Inner Layer
The inner insulation layer uses a closed-cell structure to support thermal insulation around the copper tubing. Selected configurations are listed with a temperature range of approximately -40°C to 120°C.
Available Insulation Testing
Current product information references insulation testing related to ASTM E84, UL 94, ASTM D1056, ASTM G21, ASTM C1427 and UL 723 according to the selected insulation material and specification. Buyers should confirm the applicable documentation for the exact ordered configuration.
Why Choose a 35 Ft Complete Mini Split Installation Kit?
A complete mini split installation kit combines refrigerant copper tubing with commonly required installation accessories in one package.
Compared with purchasing only an insulated copper line set, the kit also includes communication cable, drain hose, wall pipe and wall cover according to the selected configuration.
At approximately 10.67 m, the 35 ft configuration provides additional routing flexibility where a 30 ft kit may be slightly too short but a 50 ft kit would create unnecessary excess refrigerant piping.

35 Ft Mini Split Installation Considerations
Verify the Required 1/4" x 3/8" Refrigerant Pipe Sizes
Confirm that the exact HVAC equipment requires approximately 6.35 mm and 9.52 mm outside-diameter refrigerant tubing. Similar-capacity equipment can require different piping dimensions.
Confirm the 35 Ft Piping Length
Verify that approximately 35 ft / 10.67 m is suitable for the planned installation and falls within the minimum and maximum refrigerant piping limits specified by the equipment manufacturer.
Check the Pre-Flared Connections
The copper tubing is supplied with flared ends and nuts. Inspect the flare surfaces and confirm the connection dimensions before final assembly.
Verify Communication Cable Requirements
Communication and electrical requirements vary between mini split systems. Confirm conductor count, wire size and connection requirements for the exact equipment model.
Plan the Condensate Drain Route
The kit includes a 3 m drain hose. Because the refrigerant copper line is approximately 10.67 m long, confirm whether the supplied drain hose is sufficient for the planned condensate drainage route.
Check Refrigerant Charging Instructions
Some HVAC systems include a factory refrigerant charge for only a specified standard piping length. Follow the equipment manufacturer's instructions to determine whether a 35 ft installation requires refrigerant adjustment.
Check Vertical Separation
If the indoor and outdoor units are installed at different elevations, confirm the maximum permitted vertical separation specified for the exact HVAC system.
Is 1/4" x 3/8" Compatible With My Mini Split?
The 1/4" x 3/8" refrigerant piping combination is used by selected ductless mini split air conditioners and heat pump systems.
Some systems in approximately 9,000–12,000 BTU classes may use these pipe dimensions, but this is not a universal sizing rule.
Similar-capacity equipment can require different liquid-line and suction-line sizes. Always verify the exact manufacturer's installation manual before ordering.
Available Mini Split Installation Kit Sizes
The current SKU is a 35 ft / approximately 10.67 m 1/4" x 3/8" installation kit. The broader product range also includes multiple copper tube combinations and metric kit lengths.
| Size | Length | Insulation White PE | Flame Resistant |
| 1/4 + 3/8 | Current SKU: 35 ft / approx. 10.67 m; general range: 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 1/2 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 5/8 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 5/8 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 3/4 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/2 + 3/4 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 7/8 | 3m / 4m / 5m / 7m / 10m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
Mini Split Installation Kits for HVAC Distributors
DABUND supplies mini split installation kits to HVAC distributors, wholesalers, importers, contractors, project suppliers and private-label brands.
The 35 ft 1/4" x 3/8" White PE configuration provides a complete installation package for compatible HVAC projects requiring approximately 10.67 m of refrigerant piping.
OEM and Custom Mini Split Installation Kits
DABUND supports OEM and ODM supply according to the required installation-kit configuration.
Custom copper tube combinations
Custom kit lengths
White PE or Black Rubber insulation options
Multiple insulation thicknesses
Communication cable configuration
Drain hose and wall-accessory configuration
Printed product identification
Private-label packaging
Why Choose DABUND Mini Split Installation Kits?
HVAC Manufacturing Experience Since 2008
DABUND has manufactured HVAC components since 2008, supplying mini split installation kits, insulated copper tubing, line sets and related HVAC products to international customers.
Complete Installation Kit Configuration
Insulated copper tubing, communication cable, drain hose, wall pipe and wall cover can be supplied together as one installation-kit package.
Multiple Sizes and Insulation Options
Multiple copper tube combinations, kit lengths and insulation configurations are available according to buyer requirements.
DABUND Factory
DABUND manufactures insulated copper pipe, mini split line sets, installation kits and related HVAC components for international B2B customers.

SGS Testing and Insulation Standards
Current product information references insulation testing related to ASTM E84, UL 94, ASTM D1056 and ASTM G21, while copper tubing is available to ASTM B280 and C12200 specifications. Buyers should confirm applicable documentation for the exact ordered configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions to present mini split installation kits, insulated copper tubing and related HVAC products to distributors, importers and professional buyers.

Frequently Asked Questions
What is included in the 35 ft mini split installation kit?
The current product information lists a 35 ft 1/4" x 3/8" insulated copper line set, communication wire cable, 3 m drain hose, wall pipe and wall cover, together with other accessories according to the selected kit configuration.
How long is the copper refrigerant line?
The copper refrigerant line is 35 ft long, equivalent to approximately 10.67 m.
What are the metric sizes of 1/4" and 3/8" copper tubing?
A 1/4" copper tube has an outside diameter of approximately 6.35 mm, while a 3/8" copper tube has an outside diameter of approximately 9.52 mm.
Are the copper tubing ends already flared?
Yes. The current product information states that both copper tube ends are flared and supplied with nuts.
Which tube is normally the liquid line and which is the suction line?
On compatible HVAC systems, the 1/4" tube commonly functions as the liquid line while the 3/8" tube commonly functions as the suction or gas line. Always verify the equipment manufacturer's piping specification.
What mini split capacity uses a 1/4" x 3/8" line set?
Some systems in approximately 9,000–12,000 BTU classes may use this pipe combination, but this is not universal. Similar-capacity equipment can require different refrigerant pipe dimensions.
Can I select the kit by BTU capacity alone?
No. Confirm refrigerant tube dimensions, connection size, allowable piping length, electrical requirements and drainage arrangement for the exact HVAC model.
When should I choose a 35 ft installation kit?
A 35 ft kit can be useful where a 30 ft installation kit is slightly too short but a 50 ft kit would leave substantial excess piping, provided that the equipment manufacturer permits approximately 10.67 m of refrigerant piping.
Is a 35 ft line set suitable for every mini split?
No. Verify that approximately 35 ft / 10.67 m falls within the minimum and maximum refrigerant piping limits specified by the equipment manufacturer.
Does a 35 ft line set require additional refrigerant?
It depends on the equipment. Follow the manufacturer's factory-charge and refrigerant piping instructions to determine whether additional refrigerant is required.
What insulation is used on this kit?
The current product description specifies 1/2" White PE insulation. Black Rubber insulation is also listed as an available option for selected configurations.
What White PE insulation thicknesses are available?
Current product information lists White PE thickness options including 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm according to configuration.
Is Black Rubber insulation also available?
Yes. Black Rubber insulation is also listed as an available configuration. Confirm the insulation material and thickness when ordering.
How long is the included drain hose?
The current product information lists a 3 m drain hose.
Is the drain hose the same length as the 35 ft copper line?
No. The source product information lists a 3 m drain hose while the copper line is approximately 10.67 m long. Confirm the condensate drainage route before installation.
Can DABUND customize the installation kit?
Yes. OEM and ODM configurations can include different copper tube combinations, kit lengths, insulation options, printed product identification and installation accessories according to buyer requirements.
Can I get samples before placing a bulk order?
Yes. According to the current product information, DABUND can provide three sample pieces for evaluation, with the buyer covering express shipping costs. View sample information.
What payment terms are available?
Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.
What delivery terms are available?
International trade terms can include EXW, FOB, CFR and CIF according to the buyer's logistics requirements.
What is the typical delivery time?
Current product information lists typical delivery at approximately 15–20 days. Actual lead time depends on order quantity, product specification, customization and production schedule.
Who should install the mini split installation kit?
Refrigerant piping connections, electrical wiring, pressure testing, evacuation, refrigerant charging and condensate drainage should be completed by qualified HVAC personnel according to local requirements and the equipment manufacturer's instructions.