35 ft 1/4 in. x 1/2 in. Split AC Installation Kit
DABUND 35 ft 1/4 in. x 1/2 in. Split System Air Conditioner Installation Kit combines a pre-insulated copper refrigerant line set with essential accessories for compatible split AC, mini split and ductless HVAC installations.
The kit includes a 1/4 in. liquid line and 1/2 in. suction line with factory-applied insulation, together with communication wire, condensate drain hose, wall pipe, protective wall cover and flare fittings.
The refrigerant line set is 35 ft long, approximately 10.67 m, and is manufactured from 99.9% pure copper. The featured configuration uses White PE insulation for compatible indoor and outdoor refrigerant-line installations.
Quick Answer: This 35 ft 1/4 x 1/2 split AC installation kit provides a pre-insulated copper line set plus communication wire, drain hose, wall-entry components and flare fittings in one package.
35 ft Split AC Installation Kit Specifications
| Product Type | Complete Split System AC Installation Kit |
| Line Set Size | 1/4 in. x 1/2 in. |
| Liquid Line | 1/4 in. |
| Suction Line | 1/2 in. |
| Length | 35 ft / 10.67 m |
| Copper Material | 99.9% Pure Copper |
| Insulation | Factory-Applied, UV-Resistant |
| Featured Insulation | White PE Configuration Shown |
| Included Accessories | Communication wire, drain hose, wall pipe & cover, flare fittings |
| Applications | Compatible split AC, mini split and ductless HVAC systems |
| Listed Refrigerants | R410A, R32 and similar compatible HVAC refrigerants |
Split System AC Installation Kit Video
What Is Included in the 35 ft Installation Kit?
| Component | Description |
|---|
| Copper Refrigerant Line Set | 35 ft 1/4 in. liquid line + 1/2 in. suction line |
| Factory Insulation | Pre-installed insulation around the copper refrigerant tubing |
| Communication Wire | For compatible indoor-to-outdoor unit signal connection |
| Condensate Drain Hose | For condensate drainage from compatible indoor units |
| Wall Pipe | Protects the line set where it passes through the wall |
| Wall Cover | Provides a cleaner and protected wall-entry finish |
| Flare Fittings | For compatible refrigerant-line connections |
99.9% Pure Copper Refrigerant Line Set
The refrigerant tubing is manufactured from 99.9% pure copper for compatible split-system and ductless HVAC refrigerant piping applications.
The 1/4 in. liquid line and 1/2 in. suction line should always be checked against the HVAC equipment manufacturer's specified refrigerant piping dimensions before installation.
Copper tubing provides the flexibility required for routing between compatible indoor and outdoor HVAC equipment while supporting refrigerant transfer through the system.
Factory-Applied White PE Insulation
The featured product configuration uses White PE insulation around the copper refrigerant tubing.
Factory-applied insulation helps reduce unwanted heat transfer and helps control surface condensation around the refrigerant lines.
Pre-insulated tubing also reduces the amount of additional insulation work required during field installation.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Copper Flare Nut
White PE Pipe Insulation
White PE insulation provides a factory-applied protective layer around the copper tubing to help reduce thermal exchange and condensation.

Insulation Production

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulation
Complete Installation Accessories
The 35 ft installation kit combines the refrigerant line set with the main accessories required for a compatible split-system installation, helping reduce the number of components that must be sourced separately.

Available Split System Installation Kit Sizes
The following table shows standard size, length and White PE insulation options listed for the wider DABUND installation kit family. The current product on this page is the 35 ft / 10.67 m 1/4 x 1/2 configuration.
| Line Set Size | Listed Standard Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
General Line Set Size and Capacity Reference
The following capacity ranges are general references listed for the wider DABUND product family. Final refrigerant-line sizing must always follow the HVAC equipment manufacturer's specified piping dimensions.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000 / 12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000 / 18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000 / 30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000 / 48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000 / 72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
For the 1/4 x 1/2 combination, the product family lists 1.5–2.0 ton and 12,000–18,000 BTU as general references. Final selection must be based on the equipment manufacturer's required liquid-line and suction-line dimensions.
Compatible HVAC Applications
Compatible split air-conditioning systems
Ductless mini split systems
Residential HVAC installations
Apartment air-conditioning projects
Office HVAC installations
Compatible light commercial applications
Refrigerant Compatibility
The source product information lists R410A and R32 among the common refrigerants used with compatible HVAC systems.
Final refrigerant compatibility, allowable system pressure, required copper tube sizes and maximum piping length should be verified against the specific HVAC equipment manufacturer's technical specifications.
How to Select the Correct Split AC Installation Kit
Confirm the Required Refrigerant Line Sizes
Verify that the equipment requires a 1/4 in. liquid line and 1/2 in. suction line. Both tube dimensions must match the HVAC manufacturer's specifications.
Confirm the Required Installation Length
Measure the complete route between indoor and outdoor equipment and confirm that the 35 ft refrigerant line length is suitable.
Verify the Maximum Permitted Line Length
Check the HVAC manufacturer's maximum refrigerant piping length and allowable elevation difference before installation.
Confirm Communication Wire Requirements
Verify that the included communication wire specification is compatible with the indoor and outdoor equipment being connected.
Check Condensate Drainage Requirements
Confirm the condensate drain routing, hose size and required slope according to the indoor unit manufacturer's installation instructions.
Installation Considerations
Plan the Line Route Before Installation
Plan the complete refrigerant piping route before installation to reduce unnecessary bends, kinks and mechanical stress on the copper tubing.
Protect Lines at Wall Penetrations
Use the included wall pipe and protective cover where the refrigerant lines pass through the wall to help reduce abrasion and damage to the insulation.
Support the Refrigerant Line Set
Use suitable clips, straps or HVAC line brackets along the piping route to reduce sagging, vibration and insulation compression.
Follow Equipment Manufacturer Instructions
Refrigerant piping, flare connections, condensate drainage, electrical connection, evacuation, charging and commissioning should follow the equipment manufacturer's instructions.
Why Choose This 35 ft Split AC Installation Kit?
Complete Installation Package
The kit combines the pre-insulated copper refrigerant line set with essential installation accessories, reducing the need to source each component separately.
99.9% Pure Copper Tubing
The refrigerant line set uses 99.9% pure copper tubing for compatible HVAC applications.
Factory-Applied Insulation
Factory insulation helps reduce thermal transfer and condensation while reducing additional field insulation work.
Suitable for Residential and Light Commercial Projects
The kit is designed for compatible residential, apartment, office and light commercial split-system installations.
DABUND HVAC Factory
DABUND manufactures insulated copper pipe, mini split line sets, installation kits, aluminum pipe and related HVAC installation products.

Insulation Test Documentation
The source product information references insulation test standards including ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable insulation configurations.
Insulation material and applicable test documentation can vary by configuration. Buyers requiring specific certification should confirm the selected insulation material, thickness and supporting reports before ordering.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where distributors and professional buyers can review split-system installation kits, insulated copper line sets and related HVAC products.

Frequently Asked Questions
What is included in the 35 ft split AC installation kit?
The kit includes a 35 ft 1/4 in. x 1/2 in. pre-insulated copper line set, communication wire, condensate drain hose, wall pipe, wall cover and flare fittings.
What does 1/4 in. x 1/2 in. mean?
It refers to the listed outside diameters of the refrigerant tubes: 1/4 in. for the liquid line and 1/2 in. for the suction line.
How long is the refrigerant line set?
The line set is 35 ft long, equivalent to approximately 10.67 m.
What material is the refrigerant tubing made from?
The product information lists 99.9% pure copper tubing.
Is the copper tubing pre-insulated?
Yes. The refrigerant tubing is supplied with factory-applied insulation.
What insulation configuration is shown?
The featured product images show a White PE insulated configuration.
What size system can use a 1/4 x 1/2 line set?
The DABUND product family lists 1/4 in. x 1/2 in. as a general reference for some 1.5–2.0 ton or 12,000–18,000 BTU systems. Final refrigerant-line sizing must follow the equipment manufacturer's specifications.
Does the kit include communication wire?
Yes. Communication wire is included for compatible indoor-to-outdoor equipment connections.
Does the kit include a condensate drain hose?
Yes. A condensate drain hose is included in the listed accessory package.
Are wall-entry accessories included?
Yes. A wall pipe and protective wall cover are included for compatible installations.
Are flare fittings included?
Yes. Flare fittings are included in the listed installation accessory package.
Can every split AC system use this 35 ft installation kit?
No universal compatibility should be assumed. Check the required refrigerant-line sizes, permitted piping length, flare connection requirements and communication wiring for the specific HVAC equipment.
Is this installation kit listed for R410A and R32?
The source product information lists R410A and R32 among the compatible refrigerants. Final suitability should be verified against the HVAC equipment manufacturer's specifications.
Can the insulated line set be used outdoors?
The product information lists UV-resistant insulation for compatible outdoor refrigerant-line installations.
Is additional field insulation required?
Factory-applied insulation reduces the need for additional field wrapping, although local requirements and project conditions may require additional protection.
What other line set sizes are available?
Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
Can DABUND provide free samples?
Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer paying the express freight. View Sample Information
What payment terms are available?
Available payment methods include T/T, L/C at sight and credit card.
What delivery terms are available?
Available delivery terms include EXW, FOB, CFR and CIF.
Does DABUND support OEM and ODM?
Yes. OEM and ODM services, including logo customization, are available for suitable orders.
What is the typical delivery time?
The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.