Home Mini Split Line Set AC Line Set 3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
3/8" x 7/8" x 100 ft AC Line Set | Heavy-Duty Pre-Insulated Copper Refrigerant Line for HVAC Systems
1. 3/8" x 7/8" is the out dimension in inch. 9.52mm - 22.22mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

AC Line Set

Application

HVAC
Inquire
Add to Basket

100 ft 3/8 in. x 7/8 in. AC Line Set

DABUND 100 ft 3/8 in. x 7/8 in. AC Line Set provides an extended pre-insulated copper refrigerant piping solution for compatible split air conditioners, heat pumps, commercial HVAC systems and refrigeration installations.

The paired refrigerant tubing combines a 3/8 in. liquid line with a 7/8 in. suction line and provides a continuous 100 ft length for installations where indoor and outdoor equipment are positioned farther apart.

Manufactured from 99.9% pure copper with ASTM B280 / C12200 referenced in the source product information, the tubing is supplied with factory-applied Black Rubber insulation to help reduce thermal exchange and condensation during compatible HVAC operation.

Quick Answer: This 100 ft 3/8 x 7/8 AC line set combines high-purity copper tubing, Black Rubber insulation and an extended continuous coil for compatible large-capacity HVAC and refrigeration installations.

100 ft AC Line Set Video

100 ft 3/8 x 7/8 AC Line Set Specifications

Product TypePre-Insulated Copper AC Refrigerant Line Set
Pipe Size3/8 in. x 7/8 in.
Liquid Line3/8 in. / approximately 9.52 mm
Suction Line7/8 in. / approximately 22.23 mm
Length100 ft / approximately 30.5 m
Copper Material99.9% Pure Copper
Copper StandardASTM B280 / C12200 as referenced in source product information
Featured InsulationBlack Rubber
Listed Temperature Range-40°C to 120°C
Source-Listed Pressure Range2100–7000 PSI; confirm the applicable rating for the exact tube diameter and wall thickness
Listed RefrigerantsR410A and R32; final compatibility must follow equipment requirements
ApplicationsCompatible Split AC, Heat Pump, Commercial HVAC and Refrigeration Systems

100 ft Long Line Set for Extended HVAC Installations

The 100 ft continuous refrigerant line provides additional routing flexibility for compatible installations where the indoor and outdoor HVAC equipment are separated by a substantial distance.

Typical project layouts may include large residential properties, commercial air-conditioning systems, multi-story buildings and rooftop equipment installations.

A continuous long coil can help reduce unnecessary intermediate joints, provided the complete piping route remains within the HVAC equipment manufacturer's allowable refrigerant piping limits.

3/8 in. Liquid Line and 7/8 in. Suction Line

The paired copper refrigerant tubing combines a 3/8 in. liquid line with a 7/8 in. suction return line.

Before ordering, verify that the specific HVAC or refrigeration equipment requires these exact refrigerant-line dimensions.

Refrigerant pipe size should not be selected from nominal BTU or tonnage alone because required line diameters can vary between manufacturers, equipment families and individual models.

ASTM B280 C12200 Copper Refrigerant Tubing

The source product information specifies 99.9% pure copper and references ASTM B280 refrigeration tubing and C12200 copper.

Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC refrigerant piping applications.

The source content also describes the tubing as soft annealed copper for easier bending. Suitable HVAC bending tools and bend radii should still be used to reduce the risk of kinking or flattening the tubing.

Pressure Capability for R410A and R32 Applications

The source product information lists a pressure range of 2100–7000 PSI and references R410A and R32 refrigerant applications.

Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and the exact ordered configuration. Confirm the applicable tubing specification before selecting the line set for a particular HVAC system.

Black Rubber Insulated Copper Pipe

The featured product configuration uses Black Rubber insulation around the copper refrigerant tubing.

The insulation acts as both a thermal barrier and moisture-resistant layer, helping reduce unwanted heat exchange and surface condensation along the refrigerant piping route.

The source product information lists an insulation temperature range of approximately -40°C to 120°C.

Copper Pipe and Insulation Video

99.9 percent pure copper HVAC refrigerant tubing

99.9% Pure Copper

black rubber insulated copper AC line set

Black Rubber Insulated Pipe

protective plastic cap for HVAC copper refrigerant tubing

Protective Plastic Cap

Black Rubber Insulation Structure

Black Rubber insulation helps reduce unwanted heat transfer between refrigerant tubing and ambient air while providing moisture resistance around the cold copper line.

The source product information describes the insulation as having a closed-cell structure for moisture control and thermal protection.

black rubber closed cell insulation for HVAC copper pipe

Insulation Performance for Indoor and Outdoor Installations

Thermal Protection

High-density insulation helps reduce thermal exchange and maintain the refrigerant piping temperature along the installed route.

Condensation Control

Closed-cell insulation helps reduce water-vapor penetration and condensation buildup around cold refrigerant tubing.

UV and Outdoor Protection

The source product information describes applicable insulation configurations as using a UV-resistant outer structure for indoor and outdoor applications.

Flame-Resistance Documentation

The source certificate section references UL94, ASTM E84, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber insulation configurations. Confirm the exact insulation thickness and corresponding report required for the ordered product.

General 6–8 Ton HVAC Capacity Reference

The wider DABUND product family lists the 3/8 in. + 7/8 in. tubing combination as a general reference for some 6–8 ton or 72,000–96,000 BTU HVAC systems.

This is a general sizing reference only. Final pipe sizing must follow the HVAC equipment manufacturer's exact liquid-line and suction-line requirements.

Compatible HVAC and Refrigeration Applications

  • Compatible large-capacity split air-conditioning systems

  • Commercial heat-pump systems

  • Central HVAC systems requiring this pipe size

  • Commercial air-conditioning installations

  • Multi-story and rooftop HVAC projects

  • Compatible commercial refrigeration equipment

  • Extended refrigerant piping installations

Final compatibility should be confirmed from the equipment manufacturer's required line sizes, refrigerant type, maximum piping length, maximum elevation difference and pressure requirements.

Critical Checks for a 100 ft Refrigerant Run

Verify Maximum Permitted Piping Length

Confirm that the specific HVAC equipment permits at least the required 100 ft refrigerant piping route. Do not assume that every 6–8 ton system can use a 100 ft line set.

Confirm the Exact Pipe Sizes

Verify that the equipment specifically requires a 3/8 in. liquid line and 7/8 in. suction line.

Check Maximum Elevation Difference

Multi-story and rooftop installations may involve substantial vertical separation. Confirm the equipment manufacturer's maximum permitted elevation difference.

Check Additional Refrigerant Charge

A 100 ft refrigerant run may require additional refrigerant beyond the equipment's factory charge. Follow the equipment manufacturer's charging formula for the actual installed piping length.

Consider Equivalent Piping Length

Bends, fittings, elevation changes and other piping components can affect effective piping length. Follow the HVAC equipment manufacturer's engineering requirements rather than relying only on physical coil length.

Provide Proper Pipe Support

Use suitable HVAC-rated clips, straps or supports along the piping route to reduce sagging, vibration and mechanical stress on the copper tubing and insulation.

Installation Guidelines

Plan the Complete Refrigerant Route

Plan and measure the complete route before uncoiling or cutting the copper refrigerant tubing.

Maintain Proper Bend Radius

Use appropriate tube-bending methods and suitable bend radii to reduce the risk of kinking, flattening or restricting refrigerant flow.

Keep Pipe Ends Sealed

Keep open copper tube ends capped or sealed during storage and installation to reduce moisture and contamination entering the refrigerant system.

Protect the Insulation

Avoid crushing, cutting or leaving unnecessary gaps in the insulation, particularly around bends, supports and wall penetrations.

Use Correct Connection Procedures

Follow the HVAC equipment manufacturer's approved flaring, brazing and connection procedures for the selected system.

Pressure Test and Evacuate Before Startup

Follow the equipment manufacturer's approved pressure-testing, evacuation, refrigerant charging and commissioning procedures before startup.

OEM and Custom AC Line Set Options

The source product information lists customization options for importers, distributors and HVAC brands.

  • Custom pipe-size combinations

  • Custom lengths

  • Multiple insulation thicknesses

  • Logo printing on insulation

  • Private-label branding

  • Custom packaging

  • Bulk production support

100 ft 3/8 x 7/8 Black Rubber insulated copper AC line set

Available AC Line Set Sizes

SizeAvailable LengthsBlack Rubber InsulationListed Flame-Resistance Options
1/4 + 3/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 1/2 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 7/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

Length Note: The wider product-family table lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths. This specific product is 100 ft, approximately 30.5 m, so buyers should specify the required finished 100 ft length when ordering.

General Line Set Size and Capacity Reference

The following capacity ranges are general references from the wider DABUND AC line set family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact requirements.

Line Set SizeGeneral Ton ReferenceGeneral BTU Reference
1/4 + 3/8 in.0.75–1.0 Ton9,000–12,000 BTU
1/4 + 1/2 in.1.5–2.0 Ton12,000–18,000 BTU
1/4 + 5/8 in.2.0–2.5 Ton24,000–30,000 BTU
3/8 + 5/8 in.3.0–4.0 Ton36,000–48,000 BTU
3/8 + 3/4 in.4.5–6.0 Ton54,000–72,000 BTU
3/8 + 7/8 in.6.0–8.0 Ton72,000–96,000 BTU

For the 3/8 x 7/8 configuration, the DABUND product family lists 6.0–8.0 ton and 72,000–96,000 BTU as general references. Actual compatibility must be confirmed from the equipment manufacturer's specified liquid-line and suction-line dimensions.

Why Choose the DABUND 100 ft 3/8 x 7/8 AC Line Set?

Extended 100 ft Refrigerant Run

The continuous long coil provides routing flexibility for compatible commercial, multi-story and rooftop HVAC installations.

ASTM B280 / C12200 Copper

The source product information specifies 99.9% pure copper with ASTM B280 and C12200 referenced for the refrigerant tubing.

Black Rubber Factory Insulation

Factory-applied Black Rubber insulation provides thermal and moisture protection around the copper refrigerant piping.

OEM and Bulk Supply Options

Private-label branding, logo printing, custom packaging and bulk production support are listed for distributors, importers and HVAC brands.

DABUND AC Line Set Factory

DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC products for distributors, contractors and project customers.

DABUND factory manufacturing AC line sets and insulated copper pipe

Insulation Test Documentation

The source certificate section states that applicable Polypropylene or Black Rubber mini split line set insulation references ASTM E84, UL94, ASTM D1056 and ASTM G21.

Because this product page prominently features Black Rubber insulation, the certificate description is generally aligned with the displayed insulation type. Project buyers should still confirm the exact insulation thickness and corresponding test report for the ordered SKU.

DABUND Black Rubber AC line set insulation test documentation

International HVAC Exhibitions

DABUND participates in international HVAC exhibitions where distributors and professional buyers can review insulated copper tubing, AC line sets and related HVAC products.

DABUND AC line set at international HVAC exhibition

Frequently Asked Questions

What is a 3/8 x 7/8 AC line set used for?

It carries refrigerant between compatible indoor and outdoor HVAC equipment using a 3/8 in. liquid line and 7/8 in. suction line.

How long is this AC line set?

The product is 100 ft long, approximately 30.5 m.

What size HVAC system can use a 3/8 x 7/8 line set?

The wider DABUND product family lists 3/8 x 7/8 as a general reference for some 6–8 ton or 72,000–96,000 BTU systems. Final sizing must follow the HVAC equipment manufacturer's exact piping requirements.

Can every 6–8 ton HVAC system use a 100 ft line set?

No. Capacity alone does not determine compatibility. Confirm the required pipe sizes, maximum permitted piping length, elevation difference and refrigerant charging requirements for the specific equipment model.

Does a 100 ft line set require additional refrigerant?

Additional refrigerant may be required depending on the equipment's factory charge and total installed refrigerant piping length. Follow the equipment manufacturer's charging instructions.

What copper material is used?

The source product information specifies 99.9% pure copper and references ASTM B280 / C12200.

What insulation material is used?

The featured configuration uses Black Rubber insulation.

What insulation thicknesses are available?

The wider Black Rubber product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thicknesses.

What is the listed insulation temperature range?

The source product information lists approximately -40°C to 120°C.

Is the AC line set compatible with R410A and R32?

R410A and R32 are listed in the source product information. Final compatibility must be confirmed against the equipment manufacturer's refrigerant, tubing and pressure requirements.

What is the pressure rating?

The source page lists a pressure range of 2100–7000 PSI. Because allowable pressure depends on tube diameter, wall thickness, operating temperature and exact configuration, confirm the applicable rating for the ordered tubing.

Is this line set suitable for outdoor installation?

The source product information describes applicable insulation configurations as UV resistant and suitable for indoor and outdoor installations. Final outdoor suitability should be confirmed for the exact ordered insulation configuration and exposure conditions.

Can the 100 ft copper line set be shortened?

The copper tubing can be cut to suit the required project length when appropriate HVAC cutting, deburring, flaring or brazing procedures are used according to the equipment design.

What other AC line set sizes are available?

Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.

Does DABUND support OEM and ODM orders?

Yes. The source product information lists private-label branding, logo printing, insulation customization, custom packaging and bulk production support.

Is DABUND a manufacturer?

Yes. DABUND identifies itself as a manufacturer of insulated copper pipe, mini split line sets and related HVAC products.

Related Products

1. 3/8" x 7/8" x 50 ft is the out dimension in inch. 9.52mm - 22.22mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 3/8"+3/4" 50 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts.  2. Both of the two copper pipe end do flaring and nuts.  3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm.  4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m.  5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200.  6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
1. 3/8" x 5/8" is the out dimension in inch. 9.52mm - 15.88mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 3/8" x 7/8" is the out dimension in inch. 9.52mm - 22.22mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.