100 ft 3/8 in. x 7/8 in. Copper Line Set
The DABUND 100 ft 3/8 in. x 7/8 in. Copper Line Set is a heavy-duty pre-insulated refrigerant piping solution for compatible large mini split systems, VRF systems, commercial HVAC equipment, heat pumps and refrigeration applications.
The paired line set combines a 3/8 in. liquid line with a 7/8 in. suction line and provides a continuous 100 ft length, approximately 30.48 m, for projects requiring extended refrigerant piping between indoor and outdoor equipment.
The source product information specifies 99.9% pure copper and references ASTM B280 and C12200 for the copper tubing. Black Rubber is the main insulation configuration shown on this page, while PE and IXPE foam insulation options are also available.
Quick Answer: This 100 ft 3/8 x 7/8 insulated copper line set is intended for compatible high-capacity HVAC systems requiring these exact pipe sizes. The wider DABUND product-family table references 6–8 ton / 72,000–96,000 BTU systems, but final line-set sizing must follow the equipment manufacturer's installation manual.
100 ft Copper Line Set Video
100 ft 3/8 x 7/8 Copper Line Set Specifications
| Product Type | Heavy-Duty Pre-Insulated HVAC Refrigerant Copper Line Set |
| Liquid Line | 3/8 in. / 9.52 mm |
| Suction Line | 7/8 in. / 22.22 mm |
| Length | 100 ft / approximately 30.48 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 according to product specification |
| Featured Insulation | Black Rubber |
| Other Insulation Options | UV-Resistant PE / IXPE Foam |
| Listed Temperature Range | -40°C to 120°C; confirm for exact insulation configuration |
| Source-Listed Pressure Range | 2100–7000 PSI according to specification; actual allowable pressure depends on tube dimensions, wall thickness and temperature |
| Referenced Refrigerants | R410A / R32, subject to equipment and tubing requirements |
| General Family Capacity Reference | 6–8 Ton / 72,000–96,000 BTU |
| Applications | Compatible Large Mini Split / VRF / Commercial HVAC / Heat Pump / Refrigeration Systems |
3/8 in. Liquid Line and 7/8 in. Suction Line
The paired refrigerant line set uses a 3/8 in. liquid line and a 7/8 in. suction return line.
This larger pipe-size combination is used in compatible high-capacity HVAC equipment where the manufacturer specifically requires these refrigerant-line diameters.
Do not select refrigerant piping by nominal BTU capacity alone. Required line sizes vary by HVAC manufacturer, model, refrigerant and system design.
99.9% Pure Copper Refrigerant Tubing
The source product information specifies 99.9% pure copper and references C12200 DHP copper and ASTM B280 refrigeration tubing requirements.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC and refrigeration piping applications.
ASTM B280 and C12200
ASTM B280 and C12200 are referenced according to the product specification. Buyers requiring project-specific documentation should confirm the exact copper tube specification and wall thickness supplied with the ordered SKU.
Pressure Capability for R410A and R32 Applications
The source page lists an approximate pressure range of 2100–7000 PSI according to specification and references R410A and R32 refrigerant applications.
Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and exact tubing configuration. Confirm the applicable engineering data before specifying the line set for a particular HVAC or refrigeration system.
100 ft Length for Long-Distance HVAC Installations
The 100 ft continuous line equals approximately 30.48 m and provides additional routing flexibility for large buildings, commercial projects and complex HVAC layouts.
A continuous line can reduce unnecessary intermediate joints compared with joining multiple shorter tubing sections, provided the complete installation remains within the HVAC equipment manufacturer's piping limits.
Long refrigerant runs require additional engineering checks, including permitted piping length, equivalent piping length, elevation difference, refrigerant charge and proper support.
Copper Line Set and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Plastic Cap Protection
Black Rubber Pipe Insulation
Black Rubber is the primary insulation configuration shown on this page and in the wider line-set family table.
The insulation works as both a thermal layer and moisture-resistant layer around the copper refrigerant tubing.
Listed Temperature Range
The source Black Rubber section lists an operating range of approximately -40°C to 120°C. Confirm the applicable rating for the exact insulation thickness and configuration ordered.
Condensation Protection
Closed-cell insulation helps reduce surface condensation and moisture penetration around cold refrigerant lines.
UV-Resistant Configurations
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability depends on the exact insulation material, thickness and exposure conditions.

PE and IXPE Insulation Options
The source technical information also lists PE and IXPE foam insulation options for this copper line-set family.
Outer Protective Layer
UV-resistant PE film is referenced as an outer layer for applicable multi-layer insulation configurations.
Middle IXPE Foam Layer
High-density IXPE foam is referenced as a middle layer for thermal protection.
Inner Closed-Cell Layer
A closed-cell inner structure is referenced for thermal insulation and moisture control.
Typical Applications
Compatible large mini split air-conditioning systems
Multi-zone HVAC systems
VRF systems
Commercial HVAC projects
Ductless heat-pump systems
Industrial refrigeration applications where specifications match
Cold-storage refrigeration projects where pipe size and pressure requirements match
HVAC Capacity Reference for 3/8 x 7/8 Line Sets
The wider DABUND line-set family table maps the 3/8 in. + 7/8 in. configuration to approximately 6–8 ton / 72,000–96,000 BTU systems.
Another product-description section on the source page references selected 48,000–60,000 BTU applications. This illustrates why line-set size should not be selected by nominal capacity alone.
Final compatibility must follow the HVAC equipment manufacturer's required liquid-line size, suction-line size, refrigerant, wall thickness, piping length and design conditions.
Technical Specifications
| Parameter | Details |
|---|
| Product Name | 100 ft 3/8 in. x 7/8 in. Copper Line Set |
| Product Type | Heavy-Duty Insulated HVAC Refrigeration Pipe |
| Size | 3/8 in. Liquid Line + 7/8 in. Suction Line |
| Length | 100 ft / approximately 30.48 m |
| Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 according to specification |
| Source-Listed Pressure Range | 2100–7000 PSI according to specification |
| Listed Temperature Range | -40°C to 120°C |
| Insulation Options | UV-Resistant PE / IXPE Foam / Black Rubber |
| Applications | Large HVAC / VRF / Mini Split / Heat Pump / Compatible Refrigeration Systems |
Black Rubber Copper Line Set

Mini Split Line Set Size Options
| Size | Standard Family Lengths | Black Rubber Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 100 ft / approximately 30.48 m. The wider family table lists 30 m as the closest standard metric production length, so buyers should specify the exact finished 100 ft configuration when ordering.
Line Set Size and HVAC Capacity Reference
| Line Set Size | General Ton / HP Range | General BTU Range | Typical Application |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton / 0.75P–1P | 9,000–12,000 BTU | Small Mini Split AC |
| 1/4 + 1/2 in. | 1.5–2.0 Ton / 1.5P–2P | 12,000–18,000 BTU | Medium Mini Split AC |
| 1/4 + 5/8 in. | 2.0–2.5 Ton / 2P–2.5P | 24,000–30,000 BTU | Split AC / Heat Pump |
| 3/8 + 5/8 in. | 3.0–4.0 Ton / 3P–4P | 36,000–48,000 BTU | Ductless Commercial AC |
| 3/8 + 3/4 in. | 4.5–6.0 Ton / 4.5P–6P | 54,000–72,000 BTU | Large Split AC |
| 3/8 + 7/8 in. | 6.0–8.0 Ton / 6P–8P | 72,000–96,000 BTU | High-Capacity Ductless HVAC |
These capacity values are general product-family references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact requirements.
OEM and Custom Copper Line Set Options
Custom line-set lengths
Custom copper pipe-size combinations
Custom insulation thickness
Black Rubber / PE / IXPE foam options
Logo printing on insulation
Custom packaging
Private-label branding
Bulk manufacturing for distributors and contractors
Important Checks for a 100 ft Refrigerant Run
Confirm Exact Pipe Sizes
Verify that the selected HVAC or refrigeration equipment specifically requires a 3/8 in. liquid line and 7/8 in. suction line.
Verify Maximum Permitted Piping Length
A physical 100 ft line set does not mean every HVAC system permits a 100 ft installed refrigerant run. Confirm the manufacturer's maximum permitted piping length before installation.
Check Minimum Permitted Piping Length
Some HVAC equipment also specifies a minimum refrigerant piping length. Confirm both minimum and maximum limits from the installation manual.
Check Maximum Elevation Difference
If indoor and outdoor equipment are installed at different elevations, verify the manufacturer's maximum permitted vertical separation.
Check Additional Refrigerant Charge
A 100 ft refrigerant run may require additional refrigerant beyond the equipment's factory charge. Follow the manufacturer's charging instructions for the actual installed piping length.
Check Equivalent Piping Length
Bends, fittings and vertical elevation can increase equivalent piping length beyond the physical 100 ft length. Follow the equipment manufacturer's engineering limits for the complete route.
Support Long Pipe Runs
Use suitable brackets, clamps or HVAC line supports to reduce sagging, vibration, insulation compression and mechanical stress along the extended route.
Installation Guidelines
Plan the Complete Routing Path
Measure and plan the complete refrigerant piping route before uncoiling, cutting or installing the copper tubing.
Maintain Proper Bend Radius
Use appropriate HVAC tube-bending methods to reduce the risk of kinking, flattening or damaging the copper tube and surrounding insulation.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and building penetrations.
Keep Copper Ends Protected
Keep open copper tube ends sealed or capped during storage and installation to reduce moisture, dust and contamination entering the refrigerant circuit.
Use the Correct Connection Method
Prepare brazed, flared or other approved connections according to the equipment manufacturer's instructions and the applicable HVAC installation procedure.
Pressure Test and Evacuate Before Startup
Refrigerant piping should be leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.
DABUND Copper Line Set Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC components for distributors, contractors, wholesalers and OEM customers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations can meet ASTM E84, UL94, ASTM D1056 and ASTM G21 requirements according to product specification.
Black Rubber is the primary insulation configuration shown on this page, making the certificate description more closely aligned with the featured configuration. Buyers should still confirm the exact insulation material, thickness and matching test report for the ordered SKU.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review copper line sets, insulated HVAC refrigeration pipe and related HVAC components.

Frequently Asked Questions
What is a 100 ft 3/8 x 7/8 copper line set used for?
It is used as pre-insulated refrigerant piping between compatible indoor and outdoor HVAC or refrigeration equipment requiring a 3/8 in. liquid line and 7/8 in. suction line.
How long is this copper line set?
This SKU is 100 ft long, approximately 30.48 m.
What HVAC capacity can use a 3/8 x 7/8 line set?
The wider DABUND product-family table lists 3/8 x 7/8 as a general reference for some 6–8 ton or 72,000–96,000 BTU systems. Another source section references selected 48,000–60,000 BTU applications. Final line-set sizing must therefore follow the equipment manufacturer's exact specification.
What copper material is used?
The source page specifies 99.9% pure copper and references ASTM B280 and C12200 according to product specification.
What insulation options are available?
Black Rubber, PE and IXPE foam options are listed. Black Rubber is the primary insulation configuration shown on this page.
What insulation thicknesses are available?
The wider Black Rubber product-family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
What is the listed working temperature range?
The source page lists approximately -40°C to 120°C for applicable insulation configurations. Confirm the rating for the exact material ordered.
What is the pressure rating?
The source page lists a 2100–7000 PSI range according to specification. Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and exact product configuration.
Can this line set be used with R410A or R32?
R410A and R32 are referenced on the source page. Final compatibility depends on pipe size, wall thickness, allowable working pressure, installation length and equipment requirements.
Can every compatible HVAC system use a 100 ft refrigerant run?
No. Confirm the equipment manufacturer's maximum permitted piping length, elevation difference and refrigerant-charge requirements before installation.
Does a 100 ft line require additional refrigerant?
Additional refrigerant may be required depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions for the actual installed length.
Why is equivalent piping length important?
Bends, fittings and elevation changes may increase equivalent piping length beyond the physical 100 ft tube length. Equipment engineering limits should be checked for the complete installation route.
Can this copper line set be installed outdoors?
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation material and environmental exposure conditions.
Can DABUND customize this copper line set?
Yes. DABUND supports custom lengths, pipe-size combinations, insulation thickness, insulation material, logo printing, private labeling and custom packaging.
Is DABUND a manufacturer?
Yes. The source page identifies DABUND as a manufacturer of insulated copper pipe, mini split line sets, aluminum pipe and HVAC parts.
Are samples available before a bulk order?
The source page states that three free samples may be available, with the buyer generally covering express shipping costs. See the free sample page for details.
What payment terms are available?
The source page lists T/T, L/C at sight and credit card among available payment methods, subject to order requirements.
What delivery terms are available?
EXW, FOB, CFR and CIF are listed among available international delivery terms.
What is the typical delivery time?
The source page lists a normal delivery time of approximately 15–20 days, subject to quantity, production capacity and customization requirements.
Is professional HVAC installation recommended?
Yes. Refrigerant piping should be installed, connected, pressure-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.