75 ft 1/2 in. x 3/4 in. Insulated Copper Tubing
The DABUND 75 ft 1/2 in. x 3/4 in. Insulated Copper Tubing is a pre-insulated HVAC refrigerant line solution for compatible mini split systems, ductless air conditioners, heat pumps and light commercial HVAC applications requiring these copper tube diameters.
The tubing is supplied in a 75 ft length, equal to approximately 22.86 m, and uses 99.9% pure copper with factory-applied insulation for thermal protection, condensation control and easier field installation.
The listed product configuration identifies a 1/2 in. line and a 3/4 in. line. Final liquid-line and suction-line functions must be confirmed from the HVAC equipment manufacturer's piping specification because line assignments can vary by system design.
Quick Answer: This 75 ft pre-insulated copper tubing is intended for HVAC systems that specifically require 1/2 in. and 3/4 in. refrigerant tubing. There is no reliable universal Ton or BTU mapping for this pipe-size combination. Always verify pipe size, permitted piping length, elevation difference, refrigerant type and additional charge requirements before installation.
75 ft Insulated Copper Tubing Video
75 ft 1/2 x 3/4 Copper Tubing Overview
75 ft / approximately 22.86 m length
1/2 in. and 3/4 in. copper tube outside diameters
99.9% pure copper tubing
ASTM B280 and C12200 referenced for the copper tubing
Factory-applied insulation
Black Rubber insulation shown as the primary configuration
UV-resistant insulation configurations available
Compatible with applicable R410A and R32 HVAC systems when specifications match
Suitable for residential and light commercial HVAC projects
What Does 1/2 in. x 3/4 in. Mean?
The 1/2 in. and 3/4 in. dimensions refer to the outside diameters of the paired copper refrigerant tubes.
The listed configuration describes the 1/2 in. tube as the liquid line and the 3/4 in. tube as the suction line. However, the exact function of each tube should be verified from the equipment manufacturer's piping diagram before installation.
Do not select this product only by nominal HVAC capacity. The required refrigerant-line diameters depend on the specific equipment model and system design.
No Universal Ton or BTU Mapping for 1/2 x 3/4 Tubing
The 1/2 in. x 3/4 in. combination is used in HVAC systems that specifically require these pipe sizes, but there is no reliable universal Ton or BTU range that applies to every system.
Two HVAC systems with similar nominal capacity may specify different refrigerant-line diameters depending on refrigerant type, compressor design, piping length and equipment engineering.
Always use the equipment manufacturer's installation manual as the primary reference for pipe sizing.
75 ft Length for Extended HVAC Refrigerant Runs
The 75 ft length equals approximately 22.86 m and provides additional routing flexibility for installations where indoor and outdoor HVAC equipment are positioned farther apart.
Typical project layouts may include second-story installations, rooftop condensers, wider residential buildings, apartments and light commercial HVAC projects.
A continuous copper run can reduce the number of field joints required compared with combining several shorter sections, provided the total installed length remains within the equipment manufacturer's limits.
99.9% Pure Copper Refrigerant Tubing
The tubing is manufactured from 99.9% pure copper for HVAC refrigerant piping applications.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible cooling and heat-pump systems.
ASTM B280 and C12200
ASTM B280 and C12200 are referenced for the copper tubing. Buyers requiring technical documentation should confirm the exact outside diameter, wall thickness, temper and matching documents for the ordered configuration.
Factory-Applied Insulation
Factory-applied insulation reduces additional field wrapping work and provides continuous thermal coverage around the copper refrigerant tubing.
Condensation Control
Closed-cell insulation helps reduce moisture penetration and surface condensation around cold refrigerant tubing when correctly installed and sealed.
Thermal Protection
The insulation helps reduce unwanted heat transfer between the refrigerant line and surrounding environment.
UV-Resistant Outdoor Configurations
UV-resistant insulation configurations are available for compatible outdoor HVAC installations. Final outdoor suitability depends on the exact insulation specification, exposure conditions and installation environment.
R410A and R32 Refrigerant Applications
R410A and R32 are referenced among compatible HVAC refrigerant applications when the copper tube dimensions, wall thickness, system pressure requirements and equipment specifications match.
Refrigerant compatibility should be confirmed against the equipment manufacturer's installation manual rather than assumed from pipe diameter alone.
Copper Tubing and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Plastic Cap Protection
Black Rubber Pipe Insulation
Black Rubber is the primary insulation configuration shown for this product. The closed-cell structure provides thermal protection and moisture resistance around the refrigerant tubing.
Black Rubber insulation for HVAC refrigerant lines
Listed temperature range from -40°C to 120°C
Moisture and condensation control
Thermal insulation and moisture-resistant functions in one structure
Reduced field wrapping work
Compatible indoor and outdoor HVAC piping applications

HVAC Applications
Compatible mini split air conditioners
Ductless heat-pump systems
Residential HVAC installations
Apartment and multi-room AC projects
Light commercial air-conditioning systems
Extended refrigerant piping projects
Replacement and retrofit HVAC installations
Technical Specifications
| Feature | Detail |
|---|
| Product Name | 75 ft 1/2 in. x 3/4 in. Insulated Copper Tubing |
| Length | 75 ft / 22.86 m |
| Tube Diameter 1 | 1/2 in. / 12.7 mm OD |
| Tube Diameter 2 | 3/4 in. / 19.05 mm OD |
| Material | 99.9% Pure Copper |
| Copper Specification | ASTM B280 / C12200 |
| Featured Insulation | Factory-Applied Black Rubber Insulation |
| Listed Temperature Range | -40°C to 120°C for applicable Black Rubber configurations |
| Referenced Refrigerants | R410A / R32 and similar refrigerants when equipment specifications match |
| Applications | Mini Split AC / Ductless HVAC / Heat Pump / Light Commercial HVAC |
| Capacity Selection | Follow equipment manufacturer's required pipe sizes; no universal Ton / BTU mapping |
Important Checks for a 75 ft Refrigerant Run
Confirm Exact Tube Sizes
Verify that the selected HVAC equipment specifically requires 1/2 in. and 3/4 in. refrigerant tubing.
Confirm the Function of Each Tube
The listed configuration identifies 1/2 in. as the liquid line and 3/4 in. as the suction line, but the equipment manufacturer's piping diagram should be checked before installation.
Verify Maximum Permitted Piping Length
A physical 75 ft line set does not mean every compatible HVAC system permits a 75 ft refrigerant run. Check the manufacturer's maximum allowed piping length.
Check Minimum Permitted Piping Length
Some HVAC systems specify a minimum refrigerant piping length. Confirm both minimum and maximum requirements before installation.
Check Maximum Elevation Difference
If indoor and outdoor units are installed at different elevations, verify the equipment manufacturer's maximum permitted vertical separation.
Check Additional Refrigerant Charge
A 75 ft refrigerant run may require additional refrigerant depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions.
Check Equivalent Piping Length
Bends, fittings and elevation changes can increase equivalent piping length beyond the physical 75 ft tube length. Follow the equipment manufacturer's engineering limits for the complete route.
Support Long Refrigerant Runs
Use suitable HVAC-rated brackets, clips or supports along the refrigerant line to reduce sagging, vibration, insulation compression and mechanical stress.
Installation Guidelines
Measure the complete refrigerant route before cutting or positioning the copper tubing.
Confirm the required 1/2 in. and 3/4 in. tubing dimensions and each line's function.
Use suitable HVAC tube-cutting and bending tools.
Avoid sharp bends, flattening or kinking the copper tubing.
Maintain continuous insulation coverage around the refrigerant lines.
Use wall sleeves, grommets or protective covers at wall penetrations.
Keep open copper tube ends protected from moisture and contamination.
Prepare flared, brazed or other approved connections according to equipment requirements.
Pressure-test and leak-test the completed refrigerant circuit.
Evacuate, charge and commission the system according to the equipment manufacturer's instructions.

Insulated Copper Tubing Size Options
| Size | Standard Family Lengths | Black Rubber Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 75 ft / 22.86 m. The family table lists standard metric production lengths, so buyers should specify the exact finished 75 ft configuration when ordering.
General Line Set Size Reference
| Line Set Size | General Ton Range | General BTU Range | Common Application |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU | Small Mini Split AC |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU | Residential Mini Split AC |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU | Split AC Systems |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU | Mini Split / Heat Pump |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU | Larger Split AC |
| 1/2 + 3/4 in. | Follow Equipment Manual | Varies by HVAC Model | HVAC Systems Requiring 1/2 x 3/4 Tubing |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU | Commercial Ductless HVAC |
Capacity values for the other line-set sizes are general product-family references. The 1/2 x 3/4 configuration should be selected strictly according to the equipment manufacturer's piping requirements.
OEM and Custom Insulated Copper Tubing
Custom copper tube sizes
Custom line-set lengths
Custom insulation thickness
Black Rubber insulation options
UV-resistant insulation configurations
Logo and company-name printing
Pipe-size and length markings
Private-label packaging
OEM and ODM supply
DABUND Insulated Copper Tubing Factory
DABUND manufactures insulated copper pipes, mini split line sets, aluminum pipes and related HVAC products for distributors, contractors, wholesalers and OEM buyers.

Insulation Test Documentation
Applicable Polypropylene or Black Rubber insulation configurations are available with UV-resistant options and corresponding ASTM E84, UL94, ASTM D1056 and ASTM G21 test references.
Black Rubber is the primary insulation configuration shown for this product. Buyers requiring compliance documentation should confirm the exact insulation material, thickness and matching test report for the ordered configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review insulated copper tubing, mini split line sets and related HVAC products.

Frequently Asked Questions
What does 1/2 x 3/4 insulated copper tubing mean?
It refers to paired copper refrigerant tubing with outside diameters of 1/2 in. and 3/4 in. The exact function of each tube should be confirmed from the HVAC equipment manufacturer's piping specification.
How long is this insulated copper tubing?
This SKU is 75 ft long, equal to approximately 22.86 m.
What HVAC capacity uses 1/2 x 3/4 tubing?
There is no reliable universal Ton or BTU mapping for 1/2 x 3/4 tubing. Use this size only when the HVAC or refrigeration equipment manufacturer specifies these tube diameters.
Which tube is the liquid line and which is the suction line?
This product description lists the 1/2 in. tube as the liquid line and the 3/4 in. tube as the suction line. Confirm these functions against the specific equipment installation manual before installation.
What copper material is used?
The tubing is specified as 99.9% pure copper with ASTM B280 and C12200 referenced for the copper material.
What insulation is used?
Black Rubber is the primary insulation configuration shown for this product, with factory-applied UV-resistant insulation referenced for outdoor HVAC applications.
What insulation thicknesses are available?
The wider product-family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm Black Rubber insulation options.
What is the listed temperature range?
The Black Rubber configuration is listed for approximately -40°C to 120°C. Confirm the exact insulation specification for the ordered product.
Can this tubing be used with R410A and R32?
R410A and R32 are referenced for compatible applications. Final compatibility depends on copper dimensions, wall thickness, piping length, system pressure requirements and the equipment manufacturer's specifications.
Is the full 75 ft length suitable for every HVAC system?
No. Confirm the equipment manufacturer's minimum and maximum permitted piping lengths, elevation limits and refrigerant-charge requirements before installation.
Does a 75 ft refrigerant run require additional refrigerant?
It may. Additional refrigerant depends on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions for the actual installed length.
Can the 75 ft tubing be cut to a shorter length?
Yes. The copper tubing can be cut to the required project length. Proper cutting, deburring, connection preparation, leak testing and evacuation are required after modification.
Are the copper ends pre-flared?
The current product specification does not identify this 75 ft tubing as pre-flared. Confirm the required tube-end preparation before ordering.
Can this tubing be used outdoors?
UV-resistant insulation configurations are available for compatible outdoor HVAC installations. Final suitability depends on the exact insulation specification and environmental exposure.
Can DABUND customize the insulation with my logo?
Yes. DABUND supports OEM and ODM customization including logo, brand name, tube size, length and meter markings on the insulation jacket.
Can I get a sample before bulk ordering?
Samples can be provided for qualified buyers. Express shipping costs may need to be covered by the buyer. Sample requests can also be submitted through the DABUND free sample page.
Is DABUND a manufacturer?
Yes. DABUND manufactures insulated copper pipes, mini split line sets, aluminum pipes and related HVAC products.
What payment terms are available?
T/T, L/C at sight and credit card are listed among common payment methods, subject to order details.
What delivery terms are available?
EXW, FOB, CFR and CIF are listed among available international delivery terms.
What is the typical delivery time?
Typical delivery time is approximately 15–20 days, subject to order quantity, customization requirements and production scheduling.
Is professional HVAC installation recommended?
Yes. Cutting, bending, connection preparation, pressure testing, evacuation, refrigerant charging and commissioning should follow the HVAC equipment manufacturer's instructions and applicable local requirements.