3/8 in. x 7/8 in. x 100 ft Refrigeration Copper Line Set
DABUND 3/8 in. x 7/8 in. x 100 ft refrigeration copper line set is designed for compatible air-conditioning, refrigeration, ductless mini split and heat-pump installations.
The twin copper line set combines 3/8 in. and 7/8 in. seamless copper tubing with pre-installed insulation, helping simplify refrigerant piping installation between compatible indoor and outdoor HVAC equipment.
The copper tubing is made from 99.9% pure copper and meets ASTM B280 and C12200 requirements. The 3/8 in. and 7/8 in. outside diameters correspond to approximately 9.52 mm and 22.22 mm.
Quick Answer: This 100 ft pre-insulated refrigeration copper line set uses 3/8 in. and 7/8 in. ASTM B280 copper tubing for compatible long-run HVAC and refrigeration installations.
3/8 x 7/8 x 100 ft Copper Line Set Specifications
| Product Type | Pre-Insulated Refrigeration Copper Line Set |
| Copper Tube Size | 3/8 in. x 7/8 in. |
| Metric Outside Diameter | 9.52 mm x 22.22 mm |
| Length | 100 ft |
| Copper Purity | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 DHP |
| Insulation | Pre-insulated; White PE configurations available |
| Listed Temperature Range | -40°C to 120°C for applicable insulation configurations |
| Applications | Air conditioning, refrigeration, ductless mini split, heat pump and HVAC systems |
| Customization | Company name, tube size, length and other agreed markings |
Refrigeration Copper Pipe Video
Key Features of 100 ft 3/8 x 7/8 Copper Line Set
3/8 in. and 7/8 in. outside-diameter copper tubing.
Metric outside diameters of approximately 9.52 mm and 22.22 mm.
99.9% pure copper manufactured to ASTM B280 and C12200 requirements.
100 ft length for extended refrigerant piping routes.
Pre-installed insulation helps reduce additional field insulation work.
Designed for compatible air-conditioning, refrigeration, mini split and heat-pump installations.
Custom printing can include company name, tube size and length information.
ASTM B280 C12200 Refrigeration Copper Tubing
The copper tubing is manufactured from C12200 DHP copper for HVAC and refrigeration piping applications.
Seamless copper coils provide a continuous refrigerant piping route while reducing the number of field joints required across longer installations.
Always select liquid-line and suction-line dimensions according to the HVAC or refrigeration equipment manufacturer's installation specifications.

99.9% Pure Copper

White PE Insulation

Protective Plastic Cap
Pre-Insulated Refrigeration Copper Pipe
Pre-installed insulation helps reduce heat transfer between the refrigerant tubing and the surrounding environment while helping limit condensation on cold piping surfaces.
DABUND supplies multiple insulation configurations for different HVAC and refrigeration requirements. Confirm the required insulation material, thickness and applicable test documentation when ordering.

PE Insulation Construction

Insulation Pipe Production

Insulation Pipe Warehouse

Closed-Cell Insulation
Embossed PE Outer Layer
Available PE insulation constructions use an embossed outer film designed for wear resistance, UV resistance and protection during HVAC installation.
IXPE Foam Layer
Dense cross-linked PE foam helps provide thermal insulation, impact absorption and resistance to moisture penetration.
Closed-Cell Inner Structure
The closed-cell inner structure helps reduce heat transfer and moisture penetration around the refrigerant tubing.
Applicable insulation configurations are listed for temperatures from -40°C to 120°C.

Available Refrigeration Copper Pipe Sizes
| Copper Tube Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15m / 20m / 25m / 30m / 50m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15m / 20m / 25m / 30m / 50m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15m / 20m / 25m / 30m / 50m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15m / 20m / 25m / 30m / 50m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15m / 20m / 25m / 30m / 50m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15m / 20m / 25m / 30m / 50m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15m / 20m / 25m / 30m / 50m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
General Line Set Size and Capacity Reference
The following capacity ranges are general references for the DABUND copper line set family. Final tube sizing must follow the HVAC or refrigeration equipment manufacturer's specifications.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000 / 12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000 / 18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000 / 30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000 / 48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000 / 72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
Equipment requirements vary according to system design, refrigerant, piping length and elevation. Confirm the specified liquid-line and suction-line dimensions before ordering.
Why Choose a 100 ft Refrigeration Copper Line Set?
A 100 ft copper line set provides additional routing length where indoor and outdoor HVAC or refrigeration equipment must be installed farther apart.
Longer coils can reduce the need for intermediate joints across extended piping routes, depending on the actual equipment layout and installation method.
Before installation, confirm maximum allowable piping length, elevation difference, additional refrigerant requirements and line-size requirements with the equipment manufacturer.
HVAC and Refrigeration Applications
Ductless mini split air conditioners
Heat-pump systems
VRF installations
Central air-conditioning systems
Unitary HVAC systems
Compatible refrigeration equipment
OEM and Private-Label Copper Tubing
DABUND produces insulation in-house and supports customized identification for suitable wholesale and distribution orders.
Printing can include company name, copper tube size, length and other agreed information for HVAC and refrigeration distributors and private-label customers.
Refrigeration Copper Pipe Manufacturer
DABUND has manufactured refrigeration copper pipe, insulated copper line sets and HVAC installation products since 2008.
Product lines include insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation parts for distributors and project customers.

Insulation Test and Certification Options
DABUND offers insulation constructions referenced with ASTM E84, UL94, ASTM D1056 and ASTM G21 requirements.
For project purchasing, specify the required insulation construction, thickness, flame-resistance level and supporting test documentation before production.

International HVAC Exhibitions
DABUND participates in international exhibitions where HVAC and refrigeration distributors can review copper line sets and related installation products.

Frequently Asked Questions
What size copper tubing is included in this refrigeration line set?
This product uses 3/8 in. and 7/8 in. outside-diameter copper tubing, approximately 9.52 mm and 22.22 mm.
How long is this refrigeration copper line set?
This product configuration is 100 ft long.
What copper standard does the tubing meet?
The copper tubing is manufactured to ASTM B280 and C12200 requirements.
Is this seamless copper tubing?
Yes. The product is supplied as seamless copper pipe coils for compatible air-conditioning and refrigeration applications.
Is the copper tubing pre-insulated?
Yes. Pre-insulated configurations are available for compatible HVAC and refrigeration installations.
What insulation configurations are available?
White PE insulation configurations are available. Confirm the required insulation material, thickness and performance requirements before ordering.
What is the listed insulation temperature range?
Applicable insulation configurations are listed for temperatures from -40°C to 120°C.
What system size can use a 3/8 x 7/8 line set?
A 3/8 in. x 7/8 in. line set is listed as a general reference for some 6–8 ton or 72,000–96,000 BTU systems. Final sizing must follow the equipment manufacturer's requirements.
Can a 100 ft line set be used with any HVAC system?
No. Confirm the equipment manufacturer's maximum allowable refrigerant-line length, elevation difference, additional refrigerant requirements and required copper tube sizes before installation.
Can this copper line set be used for heat pumps?
Yes, provided the heat-pump manufacturer specifies 3/8 in. and 7/8 in. refrigerant tubing and permits the required line length.
What other refrigeration copper pipe sizes are available?
Available combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
What production lengths are available?
Listed production lengths include 15 m, 20 m, 25 m, 30 m and 50 m.
Can DABUND print our company name on the insulation?
Yes. Custom printing can include company name, tube size, length and other agreed product identification.
Is DABUND a refrigeration copper pipe manufacturer?
Yes. DABUND has manufactured refrigeration copper pipe and HVAC installation products since 2008.
Why is insulation used on refrigeration copper tubing?
Insulation helps reduce heat transfer between the refrigerant line and the surrounding environment and helps control condensation on cold pipe surfaces.
Should refrigerant line installation be performed by an HVAC professional?
HVAC and refrigeration line installation requires proper tube preparation, joining, pressure testing, evacuation and system commissioning. Installation should follow the equipment manufacturer's instructions and applicable professional requirements.