3/8 in. x 7/8 in. x 30 ft Copper Line Set
The DABUND 3/8 in. x 7/8 in. x 30 ft Copper Line Set is a pre-insulated HVAC refrigerant piping solution for compatible high-capacity mini split air conditioners, ductless heat pumps, central HVAC systems and light commercial cooling applications.
The paired line set combines a 3/8 in. liquid line with a 7/8 in. suction line and provides a fixed 30 ft length, approximately 9.14 m, for connecting compatible indoor and outdoor HVAC equipment.
The source product information specifies 99.9% pure copper and factory-applied insulation. ASTM B280 and C12200 are referenced for the copper tubing, while PE / Polypropylene foam insulation is listed for this SKU.
Quick Answer: This 30 ft 3/8 x 7/8 pre-insulated copper line set is intended for compatible HVAC equipment requiring these exact refrigerant-line sizes. The wider DABUND product family lists 3/8 x 7/8 as a general reference for some 6–8 ton / 72,000–96,000 BTU systems, but the equipment manufacturer’s specification must take priority.
30 ft Copper Line Set Video
3/8 x 7/8 x 30 ft Line Set Specifications
| Product Type | Pre-Insulated HVAC Refrigerant Copper Line Set |
| Liquid Line | 3/8 in. / approximately 9.52 mm |
| Suction Line | 7/8 in. / approximately 22.22 mm |
| Length | 30 ft / approximately 9.14 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standards | ASTM B280 / C12200 referenced according to product specification |
| Featured Insulation | Factory-Applied White PE / Polypropylene Foam |
| Listed Working Temperature | -40°C to 120°C; confirm for the exact insulation configuration ordered |
| Source-Listed Pressure Range | 2100–7000 PSI according to specification; actual allowable pressure depends on tube size, wall thickness and temperature |
| Referenced Refrigerants | R410A / R32, subject to equipment and tubing specification |
| General Capacity Reference | 6–8 Ton / 72,000–96,000 BTU |
| Applications | Compatible Mini Split / Ductless Heat Pump / Central HVAC / Light Commercial Systems |
3/8 in. Liquid Line and 7/8 in. Suction Line
This line set uses a 3/8 in. liquid refrigerant line and 7/8 in. suction return line.
Buyers should verify that the selected HVAC equipment specifically requires these exact copper tube diameters before ordering or installation.
Required refrigerant-line dimensions vary by equipment manufacturer, model, refrigerant and system design, so nominal tonnage or BTU capacity should only be used as an initial reference.
30 ft Length for HVAC Refrigerant Routing
The fixed 30 ft length equals approximately 9.14 m and is intended for compatible installations with a moderate distance between indoor and outdoor HVAC equipment.
A continuous refrigerant line can reduce unnecessary intermediate couplings compared with connecting several shorter sections, provided the route fits within the equipment manufacturer's permitted piping length.
Typical project environments may include residential properties, apartments, multi-zone applications and light commercial HVAC installations.
99.9% Pure Copper Refrigerant Tubing
The source product information specifies 99.9% pure copper for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC refrigerant piping applications.
ASTM B280 and C12200
ASTM B280 and C12200 are referenced in the source product information according to the copper tube specification. Buyers requiring project documentation should confirm the exact tube standard supplied with the ordered SKU.
Pressure Capability for R410A and R32 Applications
The source page lists a pressure range of approximately 2100–7000 PSI according to specification and references R410A and R32 HVAC systems.
Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and the exact ordered configuration. Confirm the applicable technical specification before installation.
Factory-Applied HVAC Insulation
Factory-applied insulation surrounds the copper refrigerant tubing to help reduce unwanted thermal exchange and surface condensation.
Thermal Protection
Insulation helps limit heat gain and heat loss along the refrigerant piping and supports stable temperature conditions around the copper line.
Condensation Control
The insulated structure helps reduce surface condensation around cold refrigerant tubing and protects surrounding building materials from moisture exposure.
UV-Resistant Configurations
UV-resistant insulation configurations are referenced on the source page for compatible outdoor installations. Final outdoor suitability depends on the exact insulation material, thickness and environmental exposure.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Plastic Cap Protection
White PE Insulation
White PE is the main insulation configuration shown in the product imagery and wider family table on this page.
The source technical specification identifies factory-applied UV-resistant PE / Polypropylene foam insulation for this product.

Insulation Production and Structure

Thermal Insulation Pipe Production

Insulated Pipe Warehouse

Inner Layer Insulated Pipe
Typical HVAC Applications
Compatible high-capacity mini split air conditioners
Ductless heat-pump systems
Central HVAC systems requiring this line size
Residential HVAC installations
Light commercial cooling and heating projects
Final compatibility must be confirmed from the equipment manufacturer's required liquid-line size, suction-line size, refrigerant, design pressure and permitted piping length.
General 72,000–96,000 BTU Capacity Reference
The wider DABUND product family lists the 3/8 in. + 7/8 in. line-set configuration as a general reference for some 6–8 ton ductless HVAC systems.
The corresponding family reference is approximately 72,000–96,000 BTU.
These capacity values are general references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact requirements.
Technical Specifications
| Feature | Specification |
|---|
| Product Name | 3/8 in. x 7/8 in. x 30 ft Copper Line Set |
| Line Set Length | 30 ft / approximately 9.14 m |
| Liquid Line | 3/8 in. / approximately 9.52 mm |
| Suction Line | 7/8 in. / approximately 22.22 mm |
| Material | 99.9% Pure Copper |
| Insulation | Factory-Applied UV-Resistant PE / Polypropylene Foam Insulation |
| Listed Working Temperature | -40°C to 120°C |
| Source-Listed Pressure Range | 2100–7000 PSI according to specification |
| Applications | Mini Split / Ductless AC / Heat Pump / Central HVAC |
| Copper Standards | ASTM B280 / C12200 according to specification |
| Insulation Documentation | Applicable insulation test standards depend on exact material and configuration |
Installation Considerations
Confirm Exact Refrigerant Line Sizes
Verify that the selected HVAC equipment specifically requires a 3/8 in. liquid line and 7/8 in. suction line.
Verify Permitted Piping Length
Confirm that the equipment manufacturer permits the proposed 30 ft refrigerant piping route and check any minimum piping-length requirement.
Check Maximum Elevation Difference
If indoor and outdoor units are installed at different elevations, verify the manufacturer's maximum permitted vertical separation.
Check Refrigerant Charge Requirements
Confirm whether the 30 ft installation falls within the equipment's factory refrigerant-charge allowance and follow the manufacturer's charging instructions.
Plan the Routing Path
Measure the installation route before fitting the line set and avoid unnecessary sharp bends that could deform the copper tubing.
Protect Insulation at Penetrations
Use suitable protective sleeves or grommets where the line set passes through walls, floors or other building structures.
Support the Refrigerant Line
Use suitable HVAC supports or brackets to reduce sagging, vibration and insulation compression along the route.
Pressure Test and Evacuate Before Startup
Refrigerant piping should be leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's installation instructions and applicable local requirements.
White PE Copper Line Set

Copper Line Set Size Options
| Size | Standard Family Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 30 ft / approximately 9.14 m. The wider family table lists metric production rolls beginning at 15 m, so the fixed 30 ft SKU should be treated separately from those standard family roll lengths.
Line Set Size and HVAC Capacity Reference
| Line Set Size | General Ton / HP Range | General BTU Range | Typical Application |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton / 0.75P–1P | 9,000–12,000 BTU | Small mini split AC |
| 1/4 + 1/2 in. | 1.5–2.0 Ton / 1.5P–2P | 12,000–18,000 BTU | Medium mini split AC |
| 1/4 + 5/8 in. | 2.0–2.5 Ton / 2P–2.5P | 24,000–30,000 BTU | Split AC / Heat Pump |
| 3/8 + 5/8 in. | 3.0–4.0 Ton / 3P–4P | 36,000–48,000 BTU | Ductless commercial AC |
| 3/8 + 3/4 in. | 4.5–6.0 Ton / 4.5P–6P | 54,000–72,000 BTU | Large split AC |
| 3/8 + 7/8 in. | 6.0–8.0 Ton / 6P–8P | 72,000–96,000 BTU | High-Capacity Ductless HVAC |
These capacity values are general product-family references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact requirements.
OEM and Custom Copper Line Set Options
Custom copper tube sizes
Custom line-set lengths
Custom insulation thickness
PE / Polypropylene / other available insulation options
Logo printing on insulation
Private-label packaging
Bulk supply for distributors and HVAC brands
OEM and ODM configurations
DABUND Copper Line Set Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC components for distributors, contractors, wholesalers and OEM customers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations can meet ASTM E84, UL94, ASTM D1056 and ASTM G21 requirements according to product specification.
Because the primary product imagery on this page shows White PE insulation, buyers requiring compliance documents should confirm the exact insulation material and matching test report for the ordered White PE configuration rather than assuming the certificate applies automatically.

International HVAC Exhibitions
DABUND participates in HVAC exhibitions where professional buyers can review mini split line sets, copper refrigerant line kits and related HVAC components.

Frequently Asked Questions
What is a 3/8 x 7/8 x 30 ft copper line set used for?
It is used as refrigerant piping between compatible indoor and outdoor HVAC equipment requiring a 3/8 in. liquid line and 7/8 in. suction line.
How long is this copper line set?
This SKU is 30 ft long, approximately 9.14 m.
What size HVAC system can use a 3/8 x 7/8 line set?
The wider DABUND product family lists 3/8 x 7/8 as a general reference for some 6–8 ton or 72,000–96,000 BTU ductless HVAC systems. Final pipe sizing must follow the equipment manufacturer's exact requirements.
What copper material is used?
The source product information specifies 99.9% pure copper and references ASTM B280 and C12200 according to product specification.
What insulation is used?
The technical specification lists factory-applied UV-resistant PE / Polypropylene foam insulation. White PE is the primary configuration shown in the product imagery.
What insulation thicknesses are available?
The wider White PE family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
What is the listed working temperature range?
The source technical table lists approximately -40°C to 120°C. Confirm the applicable range for the exact insulation configuration ordered.
What is the pressure rating?
The source page lists a 2100–7000 PSI range according to specification. Actual allowable working pressure depends on tube diameter, wall thickness, operating temperature and exact product configuration.
Can this line set be used with R410A or R32 systems?
R410A and R32 are referenced on the source page. Final compatibility depends on the equipment manufacturer's required line sizes, wall thickness, pressure rating and installation requirements.
Is 30 ft suitable for every HVAC installation?
No. Confirm the HVAC equipment manufacturer's minimum and maximum permitted piping length, elevation limits and refrigerant-charge requirements before installation.
Does a 30 ft refrigerant run require additional refrigerant?
Additional refrigerant may or may not be required depending on the equipment's factory charge and included piping allowance. Follow the equipment manufacturer's charging instructions.
Can this copper line set be used outdoors?
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation material and environmental exposure conditions.
Can DABUND customize this copper line set?
Yes. The source page lists custom pipe sizes, lengths, insulation materials, insulation thicknesses, logo printing, private-label packaging and bulk-production options.
Is DABUND a manufacturer?
Yes. The source page identifies DABUND as a manufacturer of insulated copper pipe, mini split line sets, aluminum pipe and HVAC parts.
Are samples available before a bulk order?
The source page states that three free samples may be available, with the buyer generally covering express shipping costs. See the free sample page for details.
What payment terms are available?
The source page lists T/T, L/C at sight and credit card among available payment methods, subject to order requirements.
What delivery terms are available?
EXW, FOB, CFR and CIF are listed among available international delivery terms.
What is the typical delivery time?
The source page lists a normal delivery time of approximately 15–20 days, subject to order quantity, production capacity and customization requirements.
Is professional HVAC installation recommended?
Yes. Refrigerant piping should be installed, leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.