1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 1/4"+1/2" 25 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts.
2. Both of the two copper pipe end do flaring and nuts.
3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm.
4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m.
5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200.
6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
25 ft 1/4 in. x 1/2 in. Mini Split Air Conditioner Installation Kit
The DABUND 25 ft 1/4 in. x 1/2 in. Mini Split Air Conditioner Installation Kit is a complete HVAC line set package for compatible ductless mini split air conditioners, heat pumps, residential HVAC systems and light commercial installations.
The kit includes factory-insulated 1/4 in. liquid-line and 1/2 in. suction-line copper tubing, communication wire, condensate drain hose, wall pipe sleeve, wall cover, flare nuts and installation accessories for indoor-to-outdoor HVAC connections.
The copper tubing is made from 99.9% pure copper and is available with White PE or Black Rubber factory-applied insulation.
Quick Answer: The 1/4 x 1/2 line-set family is commonly used with compatible 1.5–2.0 ton / 12,000–18,000 BTU mini split systems. Final pipe size, piping length and refrigerant requirements must follow the HVAC equipment manufacturer's installation manual.
Mini Split Installation Kit Video
What Is a Mini Split Air Conditioner Installation Kit?
A mini split air conditioner installation kit combines the refrigerant line set and key installation accessories used to connect compatible indoor and outdoor HVAC equipment.
Instead of sourcing copper tubing, communication wiring, condensate drainage and wall-entry accessories separately, the kit provides the main installation components in one package.
The 25 ft configuration is suitable for HVAC projects where the actual indoor-to-outdoor route and equipment piping limits match this line-set length.
What Is Included in This 25 ft Installation Kit?
Component
Description
1/4 in. Copper Line
Liquid line for high-pressure refrigerant delivery in compatible mini split systems.
1/2 in. Copper Line
Suction line for refrigerant vapor return to the outdoor compressor.
Factory-Applied Insulation
White PE or Black Rubber insulation for thermal protection and condensation control.
Flared Ends and Nuts
Prepared copper line ends for faster HVAC installation and connection.
Communication Wire Cable
Used for indoor and outdoor unit electrical communication connection.
Condensate Drain Hose
Helps manage condensate discharge from the indoor unit.
Wall Pipe Sleeve and Cover
Protects wall penetration and improves the final installation appearance.
Additional Installation Parts
May include putty, protective caps and mounting accessories for installation support.
Key Features
25 ft / 7.62 m complete mini split installation kit
1/4 in. liquid line and 1/2 in. suction line
99.9% pure copper tubing
Factory-applied insulation
White PE and Black Rubber insulation options
Pre-flared copper line ends with nuts
Communication wire included
Condensate drain hose included
Wall pipe sleeve and wall cover included
Suitable for compatible mini split, ductless HVAC and heat-pump systems
R410A and R32 referenced for compatible applications
OEM logo printing and customized packaging available
1/4 in. Liquid Line and 1/2 in. Suction Line
1/4 in. Liquid Line
The 1/4 in. copper tube is used as the liquid refrigerant line in this configuration.
1/2 in. Suction Line
The 1/2 in. copper tube is used as the suction refrigerant line in this configuration.
Always confirm the required liquid-line and suction-line diameters from the HVAC equipment manufacturer's installation manual before ordering.
General 12,000–18,000 BTU Capacity Reference
The 1/4 in. + 1/2 in. line-set family is commonly used with some 1.5–2.0 ton mini split air-conditioning systems.
The corresponding general capacity range is approximately 12,000–18,000 BTU.
These values are general references only. Final refrigerant-line selection must follow the HVAC equipment manufacturer's exact piping specification.
25 ft Refrigerant Line Set
The refrigerant line set is supplied in a 25 ft length, equal to approximately 7.62 m.
The length provides routing flexibility for compatible residential and light commercial mini split installations.
The physical 25 ft supply length does not mean every compatible HVAC system permits a 25 ft refrigerant run. Confirm the equipment manufacturer's piping limits before installation.
Pre-Flared Ends with Nuts
The copper refrigerant lines are supplied with pre-flared ends and nuts to reduce field preparation work during compatible HVAC installation.
Inspect each flare surface before connection and tighten the nuts using the torque specified by the HVAC equipment manufacturer.
Pressure testing, leak testing and evacuation are still required before commissioning the refrigerant circuit.
Factory-Applied Insulation
Factory-applied insulation provides consistent thermal coverage around the copper refrigerant tubing and reduces additional field insulation work.
White PE Insulation
White PE insulation is available for compatible mini split installation-kit configurations.
Black Rubber Insulation
Black Rubber insulation is also available for compatible HVAC projects requiring a different insulation configuration.
Condensation Control
Proper insulation helps reduce surface condensation around cold refrigerant tubing and protects nearby building surfaces from dripping moisture.
Essential HVAC Installation Accessories
Pre-insulated copper refrigerant line set
Communication wiring cable
Condensate drain hose
Wall pipe sleeve
Wall cover
Flare nuts
Protective caps and supporting installation accessories
Copper Line Set and Insulation Video
99.9% Pure Copper
White PE Insulated Pipe
Copper Nut
Pipe Insulation Tubing
Factory-applied thermal insulation for consistent coverage
Helps reduce unwanted heat gain and heat loss
Helps minimize condensation on the pipe surface
Protects copper tubing during indoor and outdoor installation
8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm thickness options available
M1 and B1 flame-resistance options available for applicable configurations
Insulation Production and Storage
Thermal Insulation Pipe Production
Insulation Pipe Warehouse
Inner Layer Insulated Pipe
HVAC Applications
Compatible mini split air conditioners
Ductless HVAC systems
Heat-pump refrigerant-line installations
Residential cooling and heating systems
Light commercial HVAC installations
Replacement projects
Retrofit projects
New HVAC installations
R410A and R32 are referenced for compatible applications when the HVAC equipment requires the listed tubing sizes and the remaining system requirements match.
Technical Specifications
Feature
Detail
Product Name
25 ft 1/4 in. x 1/2 in. Mini Split Air Conditioner Installation Kit
Line Set Length
25 ft / 7.62 m
Liquid Line Diameter
1/4 in. outer diameter
Suction Line Diameter
1/2 in. outer diameter
Material
99.9% Pure Copper
Insulation
Factory-Applied Thermal Insulation
Included Accessories
Communication Wire / Drain Hose / Wall Pipe and Cover / Flare Nuts
Applications
Mini Split and Ductless HVAC Systems
Compatible Refrigerants
R410A / R32 and Similar HVAC Refrigerants
Important Checks Before Installation
Confirm the Required 1/4 x 1/2 Line Size
Verify that the selected HVAC equipment specifically requires a 1/4 in. liquid line and a 1/2 in. suction line.
Verify the 25 ft Route
Measure the complete indoor-to-outdoor route and confirm that 25 ft / 7.62 m is appropriate for the installation.
Check Minimum and Maximum Piping Length
Confirm the HVAC equipment manufacturer's permitted minimum and maximum refrigerant piping lengths.
Check Elevation Difference
Verify the maximum permitted vertical separation between the indoor and outdoor equipment.
Check Refrigerant Charge Requirements
Confirm whether the equipment's factory refrigerant charge covers the actual installed piping length or whether additional refrigerant is required.
Confirm Communication Wire Compatibility
Confirm conductor count, wire gauge, voltage rating and terminal compatibility before connecting the supplied communication wire.
Maintain Drain Hose Slope
Route the condensate drain hose with the required downward slope and avoid kinks or upward sections that could restrict drainage.
Installation Guidelines
Confirm the required 1/4 in. and 1/2 in. refrigerant tube sizes.
Measure the complete indoor-to-outdoor line-set route.
Route the copper tubing without sharp bends, flattening or kinking.
Maintain continuous insulation coverage around the refrigerant lines.
Use the wall pipe sleeve and cover at the wall penetration.
Maintain the required downward slope for condensate drainage.
Verify communication-wire compatibility before electrical connection.
Inspect the pre-flared ends before assembly.
Use the HVAC equipment manufacturer's specified flare-nut torque.
Pressure-test and leak-test the completed refrigerant circuit.
Evacuate, charge and commission the system according to the equipment manufacturer's instructions.
Mini Split Air Conditioner Kit Size Options
Size
Length
Insulation White PE
Flame Resistant
1/4 + 3/8
3m / 4m / 5m / 7m / 10m
8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm
M1 / B1
1/4 + 1/2
3m / 4m / 5m / 7m / 10m
8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm
M1 / B1
1/4 + 5/8
3m / 4m / 5m / 7m / 10m
8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm
M1 / B1
3/8 + 5/8
3m / 4m / 5m / 7m / 10m
8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm
M1 / B1
3/8 + 3/4
3m / 4m / 5m / 7m / 10m
8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm
M1 / B1
1/2 + 3/4
3m / 4m / 5m / 7m / 10m
8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm
M1 / B1
3/8 + 7/8
3m / 4m / 5m / 7m / 10m
8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm
M1 / B1
Recommended Applications by AC Capacity
Line Set Size
Common AC Capacity
Typical BTU Range
Typical Application
1/4 + 3/8
0.75 ton - 1.0 ton
9,000 BTU - 12,000 BTU
Small mini split air conditioner
1/4 + 1/2
1.5 ton - 2.0 ton
12,000 BTU - 18,000 BTU
Residential mini split system
1/4 + 5/8
2.0 ton - 2.5 ton
24,000 BTU - 30,000 BTU
Split air conditioner system
3/8 + 5/8
3.0 ton - 4.0 ton
36,000 BTU - 48,000 BTU
Ductless mini split and heat pump
3/8 + 3/4
4.5 ton - 6.0 ton
54,000 BTU - 72,000 BTU
Larger split AC installation
3/8 + 7/8
6.0 ton - 8.0 ton
72,000 BTU - 96,000 BTU
Commercial ductless HVAC systems
These capacity values are general product-family references. Final line-set selection must follow the HVAC equipment manufacturer's exact piping requirements.
OEM and Custom Mini Split Installation Kits
Custom refrigerant line sizes
Custom line-set lengths
White PE and Black Rubber insulation options
Multiple insulation thickness options
Custom accessory combinations
OEM logo printing
Brand and length markings
Private-label packaging
Bulk supply for HVAC distributors and wholesalers
DABUND Factory
DABUND manufactures mini split installation kits, mini split line sets, insulated copper tubing, aluminum pipes and related HVAC products.
Insulation Test Documentation
Applicable Polypropylene or Black Rubber insulation configurations are available with UV-resistant options and corresponding ASTM E84, UL94, ASTM D1056 and ASTM G21 test references.
White PE is also available as an insulation option for this product family. For projects requiring specific compliance documentation, confirm the matching test report for the exact insulation material and thickness ordered.
International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where buyers can review mini split line sets, installation kits and related HVAC products.
Frequently Asked Questions
What is included in the 25 ft 1/4 x 1/2 mini split installation kit?
The kit includes a pre-insulated copper line set, communication wire, condensate drain hose, wall pipe sleeve, wall cover, flare nuts and other installation accessories.
What does 1/4 x 1/2 mean?
It refers to the outside diameters of the two refrigerant tubes. This configuration uses a 1/4 in. liquid line and a 1/2 in. suction line.
How long is the refrigerant line set?
The line set is 25 ft long, equal to approximately 7.62 m.
What AC capacity commonly uses a 1/4 x 1/2 line set?
The 1/4 x 1/2 line-set family is commonly used with some 1.5–2.0 ton or 12,000–18,000 BTU mini split systems. Final sizing must follow the equipment manufacturer's requirements.
What copper material is used?
The refrigerant tubing is made from 99.9% pure copper.
Are the copper line ends pre-flared?
Yes. This kit includes pre-flared copper line ends with nuts.
What insulation options are available?
White PE and Black Rubber factory-applied insulation options are available.
Does the kit include communication wire?
Yes. Communication wire is included. Confirm conductor count, wire gauge, voltage rating and equipment compatibility before installation.
Does the kit include a drain hose?
Yes. A condensate drain hose is included for compatible indoor-unit drainage.
Is 25 ft suitable for every 12K–18K mini split?
No. Confirm the HVAC equipment manufacturer's minimum and maximum permitted piping lengths, elevation limits and refrigerant-charge requirements.
Can this kit be used with R410A and R32?
R410A and R32 are referenced for compatible applications when the HVAC equipment specifications and refrigerant piping requirements match.
Can this kit be used with heat pumps?
Yes, when the heat-pump manufacturer specifies a 1/4 in. liquid line and a 1/2 in. suction line and the remaining installation requirements match.
Can this installation kit be used outdoors?
The factory-insulated copper tubing can be used for compatible indoor-to-outdoor HVAC connections when the selected insulation configuration and installation method are suitable for the environment.
Can DABUND customize the installation kit?
Yes. DABUND supports custom lengths, insulation thicknesses, insulation materials, logo printing and customized packaging for OEM and ODM customers.
Is DABUND a manufacturer?
DABUND manufactures mini split air conditioner kits, mini split line sets, insulated copper tubing, aluminum pipes and related HVAC products.
Are free samples available?
Up to 3 free samples are available for qualified customers. Express shipping costs may need to be covered by the buyer. Sample requests can be submitted through the DABUND free sample page.
What payment terms are available?
T/T, L/C at sight and credit card are available subject to order details.
What delivery terms are available?
DABUND can offer EXW, FOB, CFR and CIF for international orders.
What is the typical delivery time?
Normal delivery time is usually 15–20 days, subject to order requirements and factory scheduling.
1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.
7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 3/8" x 3/4" is the out dimension in inch. 9.52mm - 19.05mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.
7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 3/8" x 3/4" is the out dimension in inch. 9.52mm - 19.05mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.
7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.
7. Insulation we produce by ourself, can print your company name, size, meters etc.
INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.
We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.