Home Copper Pipe Insulated Copper Pipe 100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
100 ft 1/2″ x 3/4″ Insulated Copper Pipe for Mini Split HVAC Systems
1. 1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

  • 1/4,3/8,1/2,5/8,3/4,7/8,1,1-1/8

Material

99.9% pure copper

Color

Black/White

Keywords

Insulated Copper Pipe

Application

HVAC
Inquire
Add to Basket

100 ft 1/2 in. x 3/4 in. Pre-Insulated Copper Line Set

DABUND 100 ft 1/2 in. x 3/4 in. Pre-Insulated Copper Line Set is designed for compatible HVAC, air-conditioning, heat-pump and refrigeration installations requiring an extended refrigerant piping run.

The twin-tube configuration includes a 1/2 in. liquid line and 3/4 in. suction line. The 100 ft length equals approximately 30.48 m, providing additional routing flexibility between compatible indoor and outdoor HVAC equipment.

The refrigerant tubing is manufactured from 99.9% pure copper and references ASTM B280 and C12200. Factory-applied insulation helps reduce heat transfer, control condensation and protect the refrigerant tubing during installation and operation.

Quick Answer: This 100 ft 1/2 x 3/4 insulated copper line set provides a continuous long-run refrigerant piping solution for compatible HVAC systems requiring these specific tube dimensions.

100 ft 1/2 x 3/4 Copper Line Set Specifications

Product TypePre-Insulated Copper Refrigerant Line Set
Line Set Size1/2 in. x 3/4 in.
Liquid Line1/2 in. / 12.70 mm
Suction Line3/4 in. / 19.05 mm
Length100 ft / 30.48 m
Copper Material99.9% Pure Copper
Copper StandardsASTM B280 / C12200
InsulationFactory-Applied, UV-Resistant; White PE Configuration Shown
Listed Temperature Range-40°C to 120°C for applicable insulation configuration
Source Pressure Reference2100–7000 PSI general source range; confirm exact working and burst pressure for the selected configuration
ApplicationsCompatible mini split, ductless, central HVAC and refrigerant piping applications
Listed RefrigerantsR410A, R32 and other compatible HVAC refrigerants

100 ft Insulated Copper Pipe Video

Extended 100 ft Refrigerant Piping Length

The 100 ft continuous line set provides additional routing flexibility for installations where indoor and outdoor HVAC equipment are separated by a significant distance.

Extended line lengths may be useful for multi-story buildings, rooftop equipment, larger properties and projects requiring long horizontal refrigerant piping routes.

A continuous coil can also reduce the need to join multiple shorter sections of refrigerant tubing, provided the complete installation remains within the equipment manufacturer's permitted line length.

99.9% Pure Copper Refrigerant Tubing

The refrigerant tubing is manufactured from 99.9% pure copper and references ASTM B280 and C12200 for HVAC refrigerant-line applications.

Copper provides thermal conductivity, corrosion resistance and the flexibility required for professional refrigerant-line routing.

Always verify that the HVAC equipment requires a 1/2 in. liquid line and 3/4 in. suction line before ordering. Refrigerant piping dimensions must follow the equipment manufacturer's specifications.

Factory-Applied Pipe Insulation

Factory-applied insulation helps reduce unwanted heat gain and heat loss along the refrigerant piping while helping control surface condensation.

Pre-insulated construction also reduces additional insulation work during field installation and provides a more consistent finished refrigerant piping system.

The current product images show a White PE insulated configuration. Insulation material should be confirmed for the selected product specification before bulk ordering.

Copper Tubing and Insulation Video

99.9 percent pure copper HVAC refrigerant pipe

99.9% Pure Copper

white PE insulated copper refrigerant pipe

White PE Insulated Pipe

protective plastic cap for insulated copper refrigerant tubing

Protective Plastic Cap

White PE Insulation

White PE insulation configurations are available for DABUND insulated copper refrigerant tubing.

The insulation helps reduce thermal exchange and condensation while providing additional physical protection around the copper refrigerant line.

white PE embossed insulation for HVAC copper tubing

Insulation Production and Structure

thermal insulation pipe production equipment

Insulation Pipe Production

warehouse for insulated HVAC copper pipe

Insulation Pipe Warehouse

inner insulation layer for HVAC refrigerant tubing

Inner Insulation Layer

Benefits of Pre-Insulated Copper Tubing

Reduced Field Insulation Work

Factory-applied insulation reduces the amount of manual insulation wrapping required during field installation.

Condensation Control

The insulation helps limit surface condensation around cold refrigerant piping and reduces moisture contact with surrounding building surfaces.

Thermal Protection

Insulation helps reduce unwanted heat transfer between the refrigerant tubing and the surrounding environment over extended piping runs.

Continuous Long-Run Installation

A continuous 100 ft coil can reduce intermediate connections where the complete refrigerant piping route falls within the equipment manufacturer's allowable line length.

100 ft White PE Insulated Copper Line Set

The featured White PE configuration combines pre-insulated copper refrigerant tubing with a continuous 100 ft coil for compatible long-run HVAC projects.

100 ft 1/2 x 3/4 white PE insulated copper line set

Available Insulated Copper Pipe Sizes

Copper Tube SizeAvailable LengthsWhite PE InsulationListed Flame-Resistance Options
1/4 + 3/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 1/2 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 7/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

General Line Set Size and Capacity Reference

The following capacity ranges are general references from the wider DABUND insulated copper pipe family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact piping requirements.

Line Set SizeGeneral Ton ReferenceGeneral BTU Reference
1/4 + 3/8 in.0.75–1.0 Ton9,000 / 12,000 BTU
1/4 + 1/2 in.1.5–2.0 Ton12,000 / 18,000 BTU
1/4 + 5/8 in.2.0–2.5 Ton24,000 / 30,000 BTU
3/8 + 5/8 in.3.0–4.0 Ton36,000 / 48,000 BTU
3/8 + 3/4 in.4.5–6.0 Ton54,000 / 72,000 BTU
3/8 + 7/8 in.6.0–8.0 Ton72,000–96,000 BTU

The source family reference does not provide a specific tonnage or BTU mapping for the 1/2 x 3/4 combination. For this product, confirm compatibility directly from the HVAC equipment manufacturer's required liquid-line and suction-line dimensions.

Compatible HVAC Applications

  • Compatible mini split air conditioners

  • Ductless heat-pump systems

  • Central air-conditioning systems requiring compatible 1/2 x 3/4 refrigerant lines

  • Residential HVAC installations

  • Commercial HVAC installations

  • Compatible long-run refrigeration piping applications

Refrigerant Compatibility

The source product information lists R410A and R32 among the common refrigerants used with compatible HVAC installations.

Final refrigerant compatibility, working pressure, pipe dimensions and connection requirements must be verified against the specific HVAC equipment manufacturer's technical data.

Important Considerations for a 100 ft Line Set

Verify Maximum Permitted Line Length

Confirm that the HVAC equipment manufacturer permits a total refrigerant piping length of at least 100 ft.

Check Maximum Elevation Difference

For multi-story, rooftop or vertically separated installations, check the maximum permitted elevation difference between the indoor and outdoor units.

Check Additional Refrigerant Charge

Long refrigerant piping runs may require additional refrigerant according to the equipment manufacturer's charging instructions.

Confirm the Exact Pipe Size

A 100 ft line length does not determine the required tube diameter. Verify that the specific equipment requires a 1/2 in. liquid line and 3/4 in. suction line.

Support the Refrigerant Line

Use suitable HVAC clamps, straps or brackets along long piping routes to reduce sagging, vibration and mechanical stress on the copper tubing and insulation.

Installation Guidelines

Plan the Complete Line Route

Measure and plan the full piping route before installation to reduce unnecessary bends, kinks and stress on the refrigerant tubing.

Protect Tubing at Wall Penetrations

Use suitable wall sleeves or grommets where the insulated tubing passes through walls, ceilings or other structural penetrations to reduce abrasion.

Maintain Insulation Integrity

Avoid damaging or excessively compressing the insulation during routing and fastening because this can reduce thermal and condensation-control performance.

Follow the Equipment Manufacturer's Instructions

Refrigerant piping, connection, evacuation, charging and commissioning should follow the HVAC equipment manufacturer's installation instructions.

DABUND Insulated Copper Pipe Factory

DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation products for distribution and project supply.

DABUND factory producing insulated copper pipe and HVAC line sets

Insulation Test Documentation

The source product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable insulation configurations.

Insulation material and supporting documentation may vary by product configuration. Buyers requiring specific certification should confirm the selected insulation material, thickness and applicable test report before ordering.

test documentation for DABUND insulated copper pipe

International HVAC Exhibitions

DABUND participates in international HVAC exhibitions where distributors and professional buyers can review insulated copper tubing, mini split line sets and related HVAC installation products.

DABUND insulated copper line set at HVAC trade show

Frequently Asked Questions

What does 1/2 in. x 3/4 in. mean?

It refers to the listed outside diameters of the refrigerant tubes: 1/2 in. for the liquid line and 3/4 in. for the suction line.

How long is this insulated copper line set?

The product is 100 ft long, equivalent to approximately 30.48 m.

What copper material is used?

The source product information lists 99.9% pure copper tubing.

What standards are referenced for the copper tubing?

ASTM B280 and C12200 are referenced in the product information.

Is the copper tubing pre-insulated?

Yes. The copper tubing is supplied with factory-applied insulation.

What insulation configuration is shown?

The featured product images show a White PE insulated configuration.

What insulation thicknesses are available?

Listed White PE insulation thicknesses include 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.

What is the listed insulation temperature range?

The source technical table lists a temperature range of -40°C to 120°C for the applicable insulation configuration.

What is the pressure rating?

The source page lists a broad 2100–7000 PSI reference range. Because exact pressure rating can depend on tube size, wall thickness and test method, confirm the working pressure and burst pressure for the selected 1/2 x 3/4 configuration before ordering.

Can every HVAC system use a 100 ft refrigerant line?

No. Confirm the equipment manufacturer's maximum permitted piping length, elevation difference, required tube dimensions and refrigerant charging requirements.

Does a 100 ft line set require additional refrigerant?

Additional refrigerant may be required depending on the HVAC equipment and total installed line length. Follow the equipment manufacturer's charging instructions.

Is this tubing listed for R410A and R32?

The source information lists R410A and R32 among the compatible refrigerants. Final suitability should be confirmed against the equipment manufacturer's specifications.

Can this insulated copper pipe be used outdoors?

The source product information lists UV-resistant insulation for compatible indoor and outdoor refrigerant-line installations.

Is additional field insulation required?

Factory-applied insulation reduces additional field wrapping, although local codes, installation conditions and project requirements may require extra protection.

What other copper line sizes are available?

Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.

What production lengths are available?

The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths.

Can DABUND provide free samples?

Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer paying the express freight.    View Sample Information

What payment terms are available?

Available payment methods include T/T, L/C at sight and credit card.

What delivery terms are available?

Available delivery terms include EXW, FOB, CFR and CIF.

Does DABUND support OEM and ODM?

Yes. OEM and ODM services, including logo customization, are available for suitable orders.

What is the typical delivery time?

The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.

Related Products

1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 3/8" x 3/4" is the out dimension in inch. 9.52mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.