Home Copper Pipe Pre Insulated Copper Tubing 1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 100 ft Pre-Insulated Copper Tubing for HVAC & Air Conditioning Systems
1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

Pre Insulated Copper Tubing

Application

HVAC
Inquire
Add to Basket

100 ft 1/2 in. x 3/4 in. Pre-Insulated Copper Tubing

DABUND 100 ft 1/2 in. x 3/4 in. Pre-Insulated Copper Tubing provides a long-length refrigerant piping solution for compatible air-conditioning, heat-pump, HVAC and refrigeration systems requiring extended piping between equipment.

The paired copper tubing combines a 1/2 in. liquid line with a 3/4 in. suction line and provides a continuous 100 ft length, approximately 30.5 m.

Manufactured from 99.9% pure C12200 copper with ASTM B280 referenced in the source product information, the tubing is factory insulated to help reduce thermal exchange, surface condensation and additional field insulation work.

Quick Answer: This 100 ft 1/2 x 3/4 pre-insulated copper line set combines ASTM B280 copper tubing with factory-applied insulation for compatible long-distance HVAC and refrigeration installations. Final pipe sizing and allowable piping length must follow the equipment manufacturer's specifications.

100 ft Pre-Insulated Copper Tubing Video

100 ft 1/2 x 3/4 Copper Tubing Specifications

Product TypePre-Insulated Copper Refrigerant Line Set
Pipe Size1/2 in. x 3/4 in.
Liquid Line1/2 in. / 12.70 mm
Suction Line3/4 in. / 19.05 mm
Length100 ft / approximately 30.5 m
Copper Material99.9% Pure C12200 Copper
Copper StandardASTM B280
Featured InsulationBlack Rubber shown in product images and family table
Other Source-Listed InsulationPolypropylene / Rubber and PE / IXPE structures are also referenced on the page
Listed Temperature Range-40°C to 120°C; confirm applicability to the exact insulation configuration
Source-Listed Pressure Range2100–7000 PSI; confirm the applicable rating for the exact tube dimensions and wall thickness
Listed RefrigerantsR410A / R32; final compatibility must follow equipment specifications
ApplicationsCompatible HVAC / Air Conditioning / Heat Pump / Refrigeration Systems

100 ft Long-Length HVAC Refrigerant Line Set

The 100 ft continuous copper line provides additional routing flexibility for compatible installations where indoor and outdoor HVAC equipment are separated by a substantial distance.

Typical layouts may include large residential properties, commercial buildings, rooftop installations, multi-floor HVAC projects and compatible refrigeration applications.

Using a continuous long coil can reduce unnecessary intermediate joints, provided the installed refrigerant piping route remains within the HVAC equipment manufacturer's permitted piping limits.

1/2 in. Liquid Line and 3/4 in. Suction Line

This product combines a 1/2 in. liquid refrigerant line with a 3/4 in. suction return line.

Before ordering, verify that the intended HVAC or refrigeration equipment specifically requires these exact copper tubing diameters.

Refrigerant-line dimensions should not be selected from nominal system capacity alone because required liquid-line and suction-line sizes vary between equipment manufacturers, equipment families and individual models.

ASTM B280 C12200 Copper Refrigerant Tubing

The source product information specifies 99.9% pure C12200 copper and references ASTM B280 refrigeration tubing.

Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC and refrigeration piping.

Appropriate HVAC tube-bending tools and suitable bend radii should be used to reduce the risk of kinking, flattening or restricting refrigerant flow.

Pressure Capability for R410A and R32 Applications

The source product information lists a pressure range of 2100–7000 PSI and references R410A and R32 refrigerant applications.

Actual allowable working pressure depends on tube diameter, copper wall thickness, operating temperature and the exact ordered configuration. Confirm the applicable tubing specification before using the line set with a particular HVAC or refrigeration system.

Black Rubber Pre-Insulated Copper Tubing

The product images and wider product-family table prominently show Black Rubber insulation around the copper refrigerant tubing.

Black Rubber insulation acts as both a thermal layer and moisture-resistant barrier, helping reduce unwanted thermal exchange and condensation around cold refrigerant lines.

The source page lists a temperature range of approximately -40°C to 120°C for the Black Rubber insulation description.

Multi-Layer Insulation Structure

Another section of the source page describes a multi-layer insulation structure consisting of a protective outer layer, thermal insulation layer and closed-cell inner structure.

Protective Outer Layer

The source describes a UV-resistant protective outer layer intended to reduce environmental exposure of the insulation.

Thermal Insulation Layer

An insulating middle layer helps reduce heat transfer between the refrigerant tubing and surrounding air.

Closed-Cell Inner Structure

The closed-cell inner structure helps reduce water-vapor penetration and surface condensation around cold copper refrigerant lines.

Copper Line Set and Insulation Video

99.9 percent pure copper HVAC refrigerant tubing

99.9% Pure Copper

Black Rubber pre-insulated copper HVAC refrigerant tubing

Black Rubber Insulated Pipe

protective plastic cap for HVAC copper refrigerant tubing

Protective Plastic Cap

Black Rubber Insulation Detail

Black Rubber insulation provides a thermal and moisture-resistant layer around the copper refrigerant tubing.

Proper insulation coverage helps reduce condensation and protects the piping route from unnecessary moisture exposure.

Black Rubber closed-cell insulation for HVAC copper pipe

Black Rubber Copper Pipe Structure

Black Rubber pre-insulated copper tubing structure for HVAC systems

Compatible HVAC and Refrigeration Applications

  • Compatible commercial air-conditioning systems

  • Heat-pump systems

  • Central HVAC systems requiring this pipe size

  • Compatible mini split systems requiring 1/2 x 3/4 tubing

  • Compatible VRF / VRV systems where approved by the equipment manufacturer

  • Commercial refrigeration systems

  • Rooftop and multi-floor HVAC projects

  • Extended refrigerant piping installations

Final compatibility must be confirmed from the equipment manufacturer's required pipe sizes, refrigerant, maximum piping length, elevation limits and pressure requirements.

Important Checks for a 100 ft Refrigerant Run

Verify Maximum Permitted Piping Length

Confirm that the specific HVAC or refrigeration equipment permits at least the required 100 ft refrigerant piping route.

Confirm the Exact Pipe Sizes

Verify that the equipment specifically requires a 1/2 in. liquid line and 3/4 in. suction line.

Check Maximum Elevation Difference

For multi-floor and rooftop installations, confirm the maximum permitted vertical separation between indoor and outdoor equipment.

Check Additional Refrigerant Charge

A 100 ft installation may require additional refrigerant beyond the equipment's factory charge. Follow the equipment manufacturer's charging instructions for the actual installed piping length.

Consider Equivalent Piping Length

Bends, fittings and elevation changes can affect effective piping length. Follow the HVAC equipment manufacturer's engineering requirements rather than relying only on physical coil length.

Provide Proper Pipe Support

Use suitable HVAC-rated clips, straps or supports along the piping route to reduce sagging, vibration and mechanical stress on the copper tubing and insulation.

Installation Guidelines

Plan the Complete Refrigerant Route

Measure and plan the entire piping route before uncoiling or cutting the copper tubing.

Avoid Sharp Bends and Kinks

Use suitable tube-bending methods and appropriate bend radii to reduce the risk of copper tube deformation or restricted refrigerant flow.

Protect the Insulation

Avoid crushing, cutting or leaving unnecessary gaps in the insulation, particularly around bends, supports and wall penetrations.

Keep Pipe Ends Protected

Keep open copper tube ends sealed during storage and installation to reduce moisture and contamination entering the refrigeration circuit.

Pressure Test and Evacuate Before Startup

Follow the equipment manufacturer's approved pressure-testing, evacuation, refrigerant charging and commissioning procedures before startup.

OEM and Customization Options

  • Black or White insulation options

  • Logo printing on insulation

  • Custom insulation thickness

  • Custom lengths

  • Customized packaging

  • OEM and ODM production

Customization options are intended for HVAC distributors, importers, contractors and brand owners requiring project-specific or private-label configurations.

100 ft 1/2 x 3/4 Black Rubber pre-insulated copper HVAC line set

Available Pre-Insulated Copper Tubing Sizes

SizeAvailable LengthsBlack Rubber InsulationListed Flame-Resistance Options
1/4 + 3/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 1/2 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 7/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

Length Note: This product is 100 ft / approximately 30.5 m. The wider product-family table lists 30 m as a standard production length, so buyers should specify the required finished 100 ft length when ordering.

Line Set Size Selection

DABUND supplies multiple copper tube combinations for different HVAC equipment requirements. The exact size must be selected according to the equipment manufacturer's specified liquid-line and suction-line dimensions.

Line Set SizeGeneral Family Reference
1/4 + 3/8 in.0.75–1.0 Ton / 9,000–12,000 BTU general reference
1/4 + 1/2 in.1.5–2.0 Ton / 12,000–18,000 BTU general reference
1/4 + 5/8 in.2.0–2.5 Ton / 24,000–30,000 BTU general reference
3/8 + 5/8 in.3.0–4.0 Ton / 36,000–48,000 BTU general reference
3/8 + 3/4 in.4.5–6.0 Ton / 54,000–72,000 BTU general reference
1/2 + 3/4 in.No separate capacity mapping is provided in the source family table; confirm the exact equipment requirement
3/8 + 7/8 in.6.0–8.0 Ton / 72,000–96,000 BTU general reference

DABUND Manufacturing and Supply Capabilities

In-House Insulation Production

The source product information states that DABUND produces insulation in-house, supporting multiple insulation and customization configurations.

OEM and Private Label Support

Logo printing, insulation color options, custom lengths and OEM / ODM configurations are listed for suitable distributor and project orders.

International Supply

DABUND supplies pre-insulated copper tubing and related HVAC products to contractors, distributors and OEM buyers in international markets.

DABUND Pre-Insulated Copper Tubing Factory

DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC products for professional and distribution markets.

DABUND factory manufacturing pre-insulated copper tubing and HVAC line sets

Insulation Test Documentation

The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations reference ASTM E84, UL94, ASTM D1056 and ASTM G21.

Project buyers should confirm the exact insulation material, insulation thickness and corresponding test report for the ordered SKU rather than applying a general certificate to every available insulation configuration.

DABUND Black Rubber and Polypropylene insulation test documentation

International HVAC Exhibitions

DABUND participates in international HVAC exhibitions where distributors and professional buyers can review pre-insulated copper tubing, line sets and related HVAC products.

DABUND pre-insulated copper tubing at international HVAC exhibition

Frequently Asked Questions

What is 100 ft 1/2 x 3/4 pre-insulated copper tubing used for?

It is used as refrigerant piping between compatible HVAC or refrigeration equipment requiring a 1/2 in. liquid line and 3/4 in. suction line.

How long is this copper line set?

The product is 100 ft long, approximately 30.5 m.

What HVAC capacity is a 1/2 x 3/4 line set suitable for?

The source family table does not provide a separate tonnage or BTU mapping for 1/2 x 3/4 tubing. Confirm the exact pipe-size requirement from the HVAC equipment manufacturer's technical documentation.

Can every compatible HVAC system use a 100 ft line set?

No. Confirm the maximum permitted piping length, exact tube sizes, maximum elevation difference and refrigerant charging requirements for the specific HVAC model.

Does a 100 ft line set require additional refrigerant?

Additional refrigerant may be required depending on the equipment's factory charge and total installed piping length. Follow the equipment manufacturer's charging instructions.

What copper material is used?

The source product information specifies 99.9% pure C12200 copper and ASTM B280 refrigeration tubing.

What insulation is shown on this product?

The product images and wider family table prominently show Black Rubber insulation. The source page also references Polypropylene and PE / IXPE insulation structures, so the exact insulation material should be confirmed when ordering.

What Black Rubber insulation thicknesses are available?

The wider product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.

What is the listed temperature range?

The source product information lists approximately -40°C to 120°C. Confirm that the rating applies to the exact insulation material and configuration ordered.

Is the copper tubing compatible with R410A and R32?

R410A and R32 are referenced in the source product information. Final compatibility must be confirmed against the equipment manufacturer's refrigerant, tube-size and operating-pressure requirements.

What is the pressure rating?

The source page lists a pressure range of 2100–7000 PSI. The applicable pressure rating depends on tube diameter, wall thickness, operating temperature and exact configuration.

Can the tubing be used outdoors?

UV-resistant insulation configurations are referenced in the source product information. Final outdoor suitability should be confirmed for the exact insulation material and project exposure conditions.

Can the 100 ft copper tubing be shortened?

The tubing can be shortened when appropriate HVAC cutting, deburring, flaring or brazing procedures are used according to the equipment design and installation instructions.

Can DABUND customize the copper tubing?

Yes. The source page lists custom insulation colors, logo printing, custom lengths and OEM / ODM production options.

Is DABUND a manufacturer?

Yes. DABUND identifies itself as a manufacturer of insulated copper tubing, mini split line sets and related HVAC products.

Related Products

Please select a data source

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.