1. 1/4" x 3/8" is the out dimension in inch. 6.35mm - 9.52mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

Insulated Copper Pipe for Split AC

Application

HVAC
Inquire
Add to Basket

82 Ft 1/4" x 3/8" Insulated Copper Pipe for Split AC

DABUND 82 ft 1/4" x 3/8" Insulated Copper Pipe is a pre-insulated twin copper refrigerant piping solution for compatible split air conditioners, ductless mini split systems and heat pumps.

The paired copper tubing includes a 1/4" tube and a 3/8" tube, equivalent to approximately 6.35 mm and 9.52 mm outside diameter. The continuous coil length is 82 ft, approximately 25 m.

On compatible HVAC equipment, the 1/4" tube commonly functions as the liquid refrigerant line while the 3/8" tube functions as the suction or gas return line. Exact refrigerant piping dimensions should always be verified against the specifications for the specific indoor and outdoor equipment combination.

High-purity copper tubing is available to ASTM B280 and C12200 DHP specifications according to the ordered configuration. The displayed product uses black rubber insulation designed to provide thermal protection and help control condensation around refrigerant piping.

Quick Answer: This product is an 82 ft / approximately 25 m insulated copper pipe set containing 1/4" and 3/8" copper tubing, approximately 6.35 mm and 9.52 mm OD, with black rubber insulation for compatible split AC installations.

Compatibility Notice: An 82 ft refrigerant piping run is not suitable for every split AC system. Confirm the required tube sizes, maximum actual line length, equivalent piping length, vertical separation, refrigerant type and additional refrigerant requirements for the exact HVAC model.

82 Ft 1/4" x 3/8" Insulated Copper Pipe Specifications

BrandDABUND
Product TypePre-Insulated Copper Refrigerant Pipe
Copper Tube Size1/4" + 3/8"
Metric Outside DiameterApprox. 6.35 mm + 9.52 mm
Common Line Function1/4" liquid line + 3/8" suction/gas line on compatible equipment
Length82 ft / approx. 25 m
Copper MaterialHigh-purity copper / C12200 DHP according to specification
Copper Tube StandardASTM B280 specification available
Displayed InsulationBlack rubber closed-cell insulation
Insulation Thickness Options8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm
Selected Temperature RangeApprox. -40°C to 120°C depending on insulation specification
ApplicationsCompatible split AC, ductless mini split, heat pump and selected refrigeration systems
OEM / ODMLength, insulation, printing, branding and packaging customization

Key Features of the 82 Ft Insulated Copper Pipe

1/4" Liquid Line and 3/8" Suction Line

On compatible split AC and heat pump systems, the smaller 1/4" copper tube commonly serves as the liquid refrigerant line while the larger 3/8" tube serves as the suction or gas return line.

Their approximate outside diameters are 6.35 mm and 9.52 mm. Refrigerant piping requirements vary between HVAC models, so both dimensions should be verified before ordering.

Approx. 25 m Continuous Refrigerant Piping

The 82 ft length is approximately 25 m, providing an extended piping option for compatible installations where shorter 50 ft or 75 ft line sets do not provide enough routing distance.

Where permitted by the equipment manufacturer, one continuous coil can reduce intermediate refrigerant piping joints compared with connecting multiple shorter copper sections.

C12200 DHP Copper Tubing

High-purity copper provides good formability, thermal conductivity and corrosion resistance for professional HVAC refrigerant piping applications.

ASTM B280 and C12200 DHP specifications are available according to the ordered configuration. Buyers requiring a specific tube wall thickness or pressure performance should confirm the applicable technical data before ordering.

Factory-Applied Black Rubber Insulation

The displayed configuration uses black rubber insulation around the copper tubing to provide thermal protection and help control condensation along the refrigerant piping route.

Multiple Insulation Thickness Options

Available black rubber insulation thicknesses include 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm according to the selected configuration.

OEM Printing and Private Label Supply

Company name, copper tube dimensions, coil length and other product identification can be printed on the insulation for HVAC distributors, wholesalers, importers and private-label brands.

High purity copper tubing for 82 ft 1/4 x 3/8 insulated copper pipe

High-Purity Copper

Black rubber insulated copper pipe for split AC

Black Rubber Insulated Pipe

Protective plastic cap for insulated copper refrigerant pipe

Protective Plastic Caps

Black Rubber Insulation for Split AC Copper Pipe

Closed-cell black rubber insulation helps reduce unwanted heat transfer and moisture penetration while supporting condensation control around refrigerant copper tubing.

  • Closed-cell structure for moisture resistance

  • Thermal protection for refrigerant piping

  • Helps reduce surface condensation

  • Flexible construction for long piping routes

  • UV-resistant configurations available

  • Multiple insulation thickness options

  • Selected configurations with temperature ranges from approximately -40°C to 120°C

Closed-cell black rubber insulation for split AC copper piping

Thermal Protection

The closed-cell insulation structure helps reduce heat transfer between the refrigerant tubing and surrounding air.

Condensation Control

Black rubber insulation helps reduce water-vapor penetration and surface condensation. Insulation joints and field-repaired sections should be properly sealed during installation.

Flexible Extended-Run Routing

Flexible insulation helps installers route extended refrigerant piping through walls, ceilings, attics, service shafts and mechanical spaces while protecting the copper tubing.

UV-Resistant Options

UV-resistant insulation configurations are available for outdoor piping sections. Additional protective line covers may be used where greater weather or mechanical protection is required.

Insulation Testing Options

Available insulation configurations include testing related to ASTM E84, UL 94, ASTM D1056, ASTM G21, ASTM C1427 and UL 723 according to the selected insulation material and specification. Buyers should confirm applicable documentation for the exact product configuration being ordered.

Why Choose an 82 Ft Insulated Copper Pipe?

An 82 ft copper pipe set is approximately 25 m long, making it a practical metric-length option for compatible split AC installations requiring more piping distance than standard shorter coils.

The approximately 25 m continuous coil can be useful where indoor and outdoor units are separated by larger building layouts, multiple rooms, ceilings, service shafts or other extended routing paths.

A continuous coil may reduce intermediate copper joints, but the exact HVAC equipment must permit both the actual and equivalent refrigerant piping length.

82 ft 1/4 x 3/8 black rubber insulated copper pipe for split AC

82 Ft Split AC Piping Installation Considerations

Verify the Required 1/4" x 3/8" Pipe Sizes

Confirm that the exact indoor and outdoor HVAC equipment requires approximately 6.35 mm and 9.52 mm outside-diameter refrigerant tubing. Do not select refrigerant pipe dimensions only from system capacity.

Confirm Maximum Actual Piping Length

Verify that the equipment manufacturer permits approximately 82 ft / 25 m of actual refrigerant piping. Some split AC systems have maximum line-length limits below this distance.

Calculate Equivalent Piping Length

Elbows, bends and routing conditions can affect equivalent refrigerant piping length. Follow the equipment manufacturer's equivalent-length calculation method where specified.

Check Maximum Vertical Separation

If indoor and outdoor equipment are installed at different elevations, confirm the maximum permitted vertical separation specified by the HVAC equipment manufacturer.

Confirm Additional Refrigerant Requirements

Some split AC systems include a factory refrigerant charge for only a specified standard piping length. An 82 ft installation may require additional refrigerant according to the manufacturer's charging instructions.

Review Extended-Line Installation Requirements

Some HVAC equipment manufacturers specify additional requirements for extended refrigerant piping runs. Review the installation manual for the exact model before planning an approximately 25 m refrigerant line.

Support Long Horizontal and Vertical Sections

Extended refrigerant piping should be properly supported to reduce sagging, vibration and mechanical stress on the copper tubing, insulation and field connections.

Protect Insulation at Structural Penetrations

Use suitable sleeves, grommets or other protection where insulated copper piping passes through walls, floors, roofs or other structural openings.

Is 1/4" x 3/8" Compatible With My Split AC?

The 1/4" x 3/8" refrigerant piping combination is used by selected ductless mini split air conditioners and heat pump systems.

Some systems in approximately 9,000–12,000 BTU classes may use these dimensions, but this is not a universal sizing rule.

Equipment with similar nominal capacity can require different refrigerant pipe dimensions. Always verify the required liquid-line and suction-line sizes for the exact equipment model.

Applications of the 82 Ft Insulated Copper Pipe

Split Air Conditioning Systems

Suitable for compatible split AC systems that specifically require 1/4" and 3/8" refrigerant piping and permit an approximately 25 m piping route.

Ductless Mini Split Systems

Can be supplied for compatible ductless mini split systems using this paired copper tube combination.

Heat Pump Systems

Suitable for compatible heat pump systems where the manufacturer's specified pipe dimensions and maximum piping length match this configuration.

Multi-Level HVAC Installations

The approximately 25 m coil can provide additional routing flexibility in compatible multi-level installations, provided that the manufacturer's vertical-separation requirements are followed.

Residential and Light-Commercial Projects

The 82 ft length can support compatible residential and light-commercial installations where building layout requires an extended refrigerant piping route.

Available Insulated Copper Pipe Sizes

SizeLength OptionsBlack Rubber InsulationFlame-Resistant Options
1/4 + 3/8Current SKU: 82 ft / approx. 25 m; broader production options include 15m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/4 + 1/215m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/4 + 5/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 5/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 3/415m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/2 + 3/415m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 7/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1

Insulated Copper Pipe for HVAC Distributors

DABUND supplies insulated copper pipe to HVAC distributors, wholesalers, importers, contractors, engineering companies, project suppliers and private-label brands.

The 82 ft 1/4" x 3/8" black rubber insulated configuration provides an approximately 25 m stocking option for buyers serving compatible split AC, mini split and heat pump installations.

OEM and Custom Insulated Copper Pipe Supply

DABUND supports OEM and ODM production for HVAC distributors, importers and private-label brands.

  • Custom copper tube combinations

  • Custom coil lengths

  • Multiple insulation thicknesses

  • Company name and specification printing

  • Private-label packaging

  • Custom product identification

  • Bulk supply for distributors and project buyers

Why Choose DABUND Insulated Copper Pipe?

HVAC Manufacturing Experience Since 2008

DABUND has manufactured HVAC components since 2008, supplying insulated copper pipe, mini split line sets and related HVAC products to international customers.

Multiple Sizes, Lengths and Insulation Options

Multiple copper tube combinations, coil lengths and insulation thicknesses allow distributors to source refrigerant piping configurations according to installation and market requirements.

OEM and Private-Label Support

Insulation printing, product identification and packaging can be customized for HVAC brands, wholesalers and distributors.

DABUND Factory and Export Packaging

DABUND manufactures insulated copper pipe, mini split line sets and related HVAC components for international B2B customers.

DABUND insulated copper pipe factory and export packaging

SGS Testing and Insulation Standards

Available insulation configurations include testing related to ASTM E84, UL 94, ASTM D1056 and ASTM G21 according to the selected insulation material and specification. Buyers should confirm applicable documentation for the exact product configuration being ordered.

SGS testing documentation for DABUND insulated copper pipe

International HVAC Exhibitions

DABUND participates in international HVAC exhibitions to present insulated copper pipe, mini split line sets and related HVAC products to distributors, importers and professional buyers.

DABUND insulated copper pipe at international HVAC exhibition

Frequently Asked Questions

What is an 82 ft 1/4" x 3/8" insulated copper pipe set?

It is a paired refrigerant piping system containing 1/4" and 3/8" outside-diameter copper tubing with factory-applied insulation. The coil length is approximately 82 ft or 25 m.

What are the metric sizes of 1/4" and 3/8" copper tubing?

A 1/4" copper tube has an outside diameter of approximately 6.35 mm, while a 3/8" copper tube has an outside diameter of approximately 9.52 mm.

Which tube is the liquid line and which is the suction line?

On compatible systems, the 1/4" tube commonly functions as the liquid line while the 3/8" tube functions as the suction or gas line. Always verify the equipment manufacturer's piping specification.

What split AC capacity uses a 1/4" x 3/8" pipe set?

Some systems in approximately 9,000–12,000 BTU classes may use this pipe combination, but this is not universal. Similar-capacity equipment can require different refrigerant pipe dimensions.

Can I select the insulated copper pipe by BTU capacity alone?

No. Refrigerant pipe sizing depends on equipment design, refrigerant type, actual piping length, vertical separation and manufacturer specifications.

Why is 82 ft approximately 25 m?

An 82 ft coil is approximately 25 m long, making this configuration practical for buyers and projects that commonly specify refrigerant copper piping in metric lengths.

Can every split AC use an 82 ft refrigerant pipe?

No. Verify that approximately 82 ft / 25 m falls within the maximum actual and equivalent refrigerant piping limits permitted by the exact equipment model.

Does an 82 ft installation require additional refrigerant?

It may. Some HVAC systems include a factory refrigerant charge for only a specified standard piping length. Follow the equipment manufacturer's instructions to determine whether additional refrigerant is required.

Does vertical separation matter with an 82 ft piping run?

Yes. Verify the maximum permitted vertical separation between indoor and outdoor equipment before planning an extended refrigerant piping route.

What is equivalent refrigerant piping length?

Actual length is the measured copper piping route. Equivalent length may also account for bends and other piping conditions according to the equipment manufacturer's calculation method.

What insulation is shown on this product?

The displayed product configuration uses black rubber closed-cell insulation designed to provide thermal protection and help control condensation around refrigerant copper tubing.

What insulation thicknesses are available?

Available insulation thickness options include 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm depending on the selected configuration.

Is UV-resistant insulation available?

Yes. UV-resistant insulation configurations are available according to the selected insulation material and specification.

What pressure rating does the copper tubing have?

Allowable working and test pressure depends on copper tube diameter, wall thickness, material specification and ordered configuration. Buyers requiring a specific pressure rating should confirm the applicable technical data before ordering.

Can DABUND customize the insulated copper pipe?

Yes. OEM and ODM options include copper tube combinations, coil lengths, insulation thickness, printed identification and private-label packaging.

Can I get samples before placing a bulk order?

Yes. According to the current product information, DABUND can provide three sample pieces for evaluation, with the buyer covering express shipping costs. View sample information.

What payment terms are available?

Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.

What delivery terms are available?

International trade terms can include EXW, FOB, CFR and CIF according to the buyer's logistics requirements.

What is the typical delivery time?

Current product information lists typical delivery at approximately 15–20 days. Actual lead time depends on order quantity, product specification, customization and production schedule.

Who should install an 82 ft insulated copper refrigerant pipe?

Refrigerant piping, flare or brazed connections, pressure testing, evacuation, refrigerant charging and extended-line setup should be completed by qualified HVAC personnel according to local requirements and the equipment manufacturer's instructions.

Related Products

1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 3/8" x 3/4" is the out dimension in inch. 9.52mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.