100 ft 1/4 in. x 3/8 in. Insulated Copper Pipe
The DABUND 100 ft 1/4 in. x 3/8 in. Insulated Copper Pipe is a pre-insulated HVAC refrigerant line set for compatible mini split air conditioners, heat pumps, air-conditioning systems and refrigeration applications requiring an extended piping route.
The paired line set combines a 1/4 in. liquid line with a 3/8 in. suction line and provides a continuous 100 ft length, equal to approximately 30.48 m.
The source product information specifies 99.9% pure copper and references ASTM B280 and C12200 according to product specification. White PE is the primary insulation configuration shown on this page, while other insulation configurations are also available.
Quick Answer: This 100 ft 1/4 x 3/8 pre-insulated copper line set is generally referenced for compatible 0.75–1.0 ton / 9,000–12,000 BTU mini split systems. Because 100 ft is a long refrigerant run, always verify the HVAC equipment manufacturer's permitted piping length, elevation difference and additional refrigerant-charge requirements.
100 ft Insulated Copper Pipe Video
100 ft 1/4 x 3/8 HVAC Line Set Specifications
| Product Type | Pre-Insulated HVAC Copper Refrigerant Line Set |
| Liquid Line | 1/4 in. / 6.35 mm |
| Suction Line | 3/8 in. / 9.52 mm |
| Length | 100 ft / approximately 30.48 m |
| Structure | Twin Pre-Insulated Copper Pipes |
| Copper Material | 99.9% Pure Copper |
| Copper Standards | ASTM B280 / C12200 according to product specification |
| Featured Insulation | White PE |
| Other Insulation Options | High-Density PE / Rubber Insulation Options |
| Listed Temperature Range | -40°C to 120°C; confirm for exact insulation configuration |
| Source-Listed Pressure Range | 2100–7000 PSI according to specification; actual allowable pressure depends on tube dimensions, wall thickness and temperature |
| Referenced Refrigerant | R410A; other refrigerants require specification confirmation |
| General Capacity Reference | 0.75–1.0 Ton / 9,000–12,000 BTU |
| Applications | Compatible Mini Split AC / Heat Pump / HVAC / Refrigeration Systems |
1/4 in. Liquid Line and 3/8 in. Suction Line
This line set combines a 1/4 in. liquid refrigerant line with a 3/8 in. suction line.
The 1/4 x 3/8 configuration is widely used in compatible small-capacity mini split systems, but required line dimensions vary by equipment manufacturer and model.
Always verify both the liquid-line and suction-line requirements from the HVAC equipment installation manual before ordering.
General 9,000–12,000 BTU Capacity Reference
The wider DABUND product family lists the 1/4 in. + 3/8 in. configuration as a general reference for some 0.75–1.0 ton mini split air conditioners.
The corresponding family reference is approximately 9,000–12,000 BTU.
These capacity values are general references only. Final refrigerant-line sizing and maximum permitted piping length must follow the HVAC equipment manufacturer's exact specifications.
99.9% Pure Copper Refrigerant Tubing
The source page specifies 99.9% pure copper for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC and refrigeration piping applications.
ASTM B280 and C12200
ASTM B280 and C12200 are referenced according to product specification. Buyers requiring project documentation should confirm the exact copper tube dimensions, wall thickness and applicable test documentation for the ordered configuration.
Pressure Capability for Modern HVAC Refrigerants
The source page lists a pressure range of approximately 2100–7000 PSI according to specification and references R410A applications.
Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and exact product configuration. Confirm the applicable engineering specification before installation.
100 ft Length for Extended HVAC Installations
The continuous 100 ft line equals approximately 30.48 m and provides additional routing flexibility for compatible HVAC installations requiring a longer indoor-to-outdoor refrigerant path.
A continuous copper line can reduce unnecessary intermediate joints compared with connecting multiple shorter sections, provided the complete installation remains within the HVAC equipment manufacturer's allowable piping limits.
A physical 100 ft line set does not mean every 9K or 12K mini split permits a 100 ft refrigerant run.
Factory-Applied Insulation
Factory-applied insulation surrounds the copper tubing and reduces additional field insulation work.
UV-Resistant Insulation
The source page references UV-resistant insulation for compatible indoor and outdoor HVAC environments. Final outdoor suitability depends on the exact insulation material, thickness and exposure conditions.
Listed Temperature Range
Applicable insulation configurations are listed with a temperature range of approximately -40°C to 120°C. Confirm the rating for the exact ordered material.
Condensation and Moisture Protection
The closed-cell insulation structure helps reduce moisture penetration and surface condensation around cold refrigerant piping.
Three-Layer Insulation Structure
Outer Protective Layer
UV-resistant PE film is referenced as the outer protective layer for applicable multi-layer insulation configurations.
Middle IXPE Foam Layer
IXPE foam is referenced as the middle thermal-insulation layer.
Inner Closed-Cell Layer
An airtight closed-cell inner structure is referenced for thermal and moisture protection around the refrigerant tubing.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Plastic Cap Protection
White PE Insulation
White PE is the primary insulation configuration shown in the product imagery and wider product-family table.
The insulation provides factory-applied coverage around the refrigerant tubing and helps reduce field wrapping work.

Insulation Production and Structure

Thermal Insulation Pipe Production

Insulated Pipe Warehouse

Inner Layer Insulated Pipe
Typical HVAC Applications
Compatible residential air-conditioning installations
Mini split air conditioners
Heat-pump systems
Commercial HVAC systems requiring this line size
Compatible refrigeration systems
Long-distance refrigerant-line installations where equipment limits permit
Benefits of Pre-Insulated Copper Pipe
Reduced Field Insulation Work
Factory-applied insulation reduces additional on-site wrapping and simplifies installation preparation.
Consistent Insulation Coverage
Factory insulation helps provide consistent coverage around the paired refrigerant lines.
Condensation Protection
Closed-cell insulation helps reduce condensation around cold copper tubing when the selected thickness and material match the operating environment.
OEM and Customization Options
Custom insulation colors including black and white
Logo printing on insulation
Custom line-set lengths
Custom copper pipe-size combinations
Pipe markings
Custom packaging for distributors and private-label brands
OEM and ODM manufacturing support
White PE Copper Line Set

Insulated Copper Pipe Size Options
| Size | Standard Family Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 100 ft / approximately 30.48 m. The wider family table lists 30 m as the closest standard metric length, so buyers should specify the exact finished 100 ft configuration when ordering.
Line Set Size and HVAC Capacity Reference
| Line Set Size | General Ton / HP Range | General BTU Range | Typical Application |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton / 0.75P–1P | 9,000–12,000 BTU | Small Mini Split AC |
| 1/4 + 1/2 in. | 1.5–2.0 Ton / 1.5P–2P | 12,000–18,000 BTU | Medium Mini Split AC |
| 1/4 + 5/8 in. | 2.0–2.5 Ton / 2P–2.5P | 24,000–30,000 BTU | Split AC / Heat Pump |
| 3/8 + 5/8 in. | 3.0–4.0 Ton / 3P–4P | 36,000–48,000 BTU | Ductless Commercial AC |
| 3/8 + 3/4 in. | 4.5–6.0 Ton / 4.5P–6P | 54,000–72,000 BTU | Large Split AC |
| 3/8 + 7/8 in. | 6.0–8.0 Ton / 6P–8P | 72,000–96,000 BTU | High-Capacity Ductless HVAC |
These capacity values are general product-family references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact requirements.
Important Checks for a 100 ft Refrigerant Run
Confirm Exact Pipe Sizes
Verify that the selected HVAC equipment specifically requires a 1/4 in. liquid line and 3/8 in. suction line.
Verify Maximum Permitted Piping Length
Confirm that the HVAC equipment permits a 100 ft refrigerant piping route. Many small mini split systems have maximum piping lengths below 100 ft.
Check Minimum Permitted Piping Length
Some equipment also specifies a minimum refrigerant piping length. Confirm both minimum and maximum limits before installation.
Check Maximum Elevation Difference
If indoor and outdoor units are installed at different elevations, verify the manufacturer's maximum permitted vertical separation.
Check Additional Refrigerant Charge
A 100 ft refrigerant run may require additional refrigerant beyond the equipment's factory charge. Follow the manufacturer's charging instructions for the actual installed piping length.
Check Equivalent Piping Length
Bends, fittings and elevation changes may increase equivalent piping length beyond the physical 100 ft line. Follow the equipment manufacturer's engineering limits for the complete installation route.
Support Long Pipe Runs
Use appropriate HVAC clamps, straps or brackets along long refrigerant runs to reduce sagging, vibration, insulation compression and mechanical stress.
Installation Guidelines
Plan the Complete Routing Path
Measure and plan the entire refrigerant route before uncoiling, cutting or modifying the copper tubing.
Avoid Sharp Bends and Kinks
Use suitable HVAC tube-bending methods and appropriate bend radii to reduce the risk of tube flattening or refrigerant-flow restriction.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and wall penetrations.
Keep Copper Ends Protected
Keep open copper ends capped or sealed during storage and installation to reduce moisture, dust and contamination entering the refrigerant circuit.
Pressure Test and Evacuate Before Startup
Refrigerant piping should be properly connected, leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.
DABUND Insulated Copper Pipe Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC components for contractors, distributors, wholesalers and OEM customers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations can meet ASTM E84, UL94, ASTM D1056 and ASTM G21 requirements according to product specification.
White PE is the primary insulation configuration shown on this page. Buyers requiring certification for White PE should therefore confirm the exact material, thickness and corresponding test report rather than assuming that Polypropylene or Black Rubber documentation applies automatically.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review mini split line sets, insulated copper pipes, HVAC air-conditioning line sets and related products.

Frequently Asked Questions
What is a 1/4 x 3/8 insulated copper pipe used for?
It is used as refrigerant piping between compatible indoor and outdoor HVAC equipment requiring a 1/4 in. liquid line and 3/8 in. suction line.
How long is this copper line set?
This SKU is 100 ft long, approximately 30.48 m.
What HVAC capacity commonly uses a 1/4 x 3/8 line set?
The wider DABUND product family lists 1/4 x 3/8 as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU mini split systems. Final pipe sizing must follow the equipment manufacturer's exact requirements.
Can every 9K or 12K mini split use a 100 ft line set?
No. Many small mini split systems have maximum piping lengths shorter than 100 ft. Confirm maximum line length, elevation difference and refrigerant-charge requirements before installation.
What copper material is used?
The source page specifies 99.9% pure copper and references ASTM B280 and C12200 according to product specification.
What insulation is shown on this page?
White PE is the primary insulation configuration shown in the product imagery and wider product-family table.
What insulation thicknesses are available?
The wider White PE product-family table lists insulation thicknesses of 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.
What is the listed insulation temperature range?
The source page lists approximately -40°C to 120°C for applicable insulation configurations. Confirm the rating for the exact ordered material.
What is the pressure rating?
The source page lists a 2100–7000 PSI range according to specification. Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and exact product configuration.
Can this insulated copper pipe be used with R410A?
R410A is referenced on the source page. Final compatibility depends on the equipment manufacturer's required pipe dimensions, copper wall thickness, allowable pressure and installation requirements.
Does a 100 ft refrigerant run require additional refrigerant?
It may. Additional refrigerant depends on the HVAC equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions for the actual installed length.
Why should equivalent piping length be checked?
Bends, fittings and elevation changes can increase equivalent piping length beyond the physical 100 ft copper length. Check the equipment manufacturer's engineering limits for the complete route.
Can this insulated copper pipe be used outdoors?
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation material and exposure conditions.
Can DABUND customize the insulated copper pipe?
Yes. The source page lists custom insulation colors, logo printing, pipe markings, custom lengths, pipe-size combinations and private-label packaging.
Who typically buys this product?
The product is intended for HVAC contractors, mini split installers, distributors, wholesalers, importers, refrigeration project buyers and private-label HVAC brands.
Is professional HVAC installation recommended?
Yes. Refrigerant piping should be installed, connected, leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.