Home AC Accessories Manifold Gauge Set Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
Dabund Brand Refrigerant Gauge Manifold – Professional HVAC Manifold Gauge Set Supplier
  • DABUND

  • Brass

Application

R134a R404a R22 R12
Inquire
Add to Basket

Professional HVAC Refrigerant Gauge Manifold Set

DABUND Refrigerant Gauge Manifold is designed for HVAC technicians, refrigeration contractors, service companies, distributors and professional tool buyers who require reliable pressure measurement during air-conditioning and refrigeration service.

The manifold gauge set combines a durable brass manifold body, analog high- and low-pressure gauges, double O-ring piston valves and refrigerant charging connections for professional HVAC diagnostic, charging and evacuation work.

The source product specification lists compatibility with R134a, R404a, R22 and R12 refrigerants, making this configuration suitable for a range of compatible air-conditioning and refrigeration service applications.

Quick Answer: This DABUND HVAC manifold gauge set uses a brass body, analog high- and low-pressure gauges and double O-ring piston valves for compatible R134a, R404a, R22 and R12 refrigeration systems.

Refrigerant Gauge Manifold and Charging Hose

DABUND HVAC refrigerant gauge manifold double meter valve

Testing Manifold Double Meter Valve

refrigerant filling hose for HVAC manifold gauge set

Refrigerant Filling Hose

What Is a Refrigerant Gauge Manifold?

A refrigerant gauge manifold, also known as an HVAC manifold gauge set, is a professional service tool used to monitor refrigerant-side pressures and assist technicians during diagnostic, charging and evacuation procedures.

The manifold connects to compatible HVAC or refrigeration service ports through refrigerant hoses and allows the technician to read both low-side and high-side system pressure.

Measure High- and Low-Side Pressure

Separate analog gauges provide pressure information from the low-pressure and high-pressure sides of the refrigeration circuit.

Assist HVAC System Diagnosis

Pressure readings can help trained technicians identify abnormal operating conditions that may be associated with refrigerant charge problems, restrictions, leaks or other system faults.

Support Refrigerant Charging

The manifold provides controlled service connections for compatible refrigerant charging procedures when used according to the HVAC equipment manufacturer's service instructions.

Support Evacuation Procedures

A manifold gauge set can also form part of the service connection between the refrigeration system and appropriate evacuation equipment during professional installation or repair work.

DABUND Manifold Gauge Set Technical Specifications

ParameterDetails
BrandDABUND
MaterialBrass
Gauge TypeAnalog High- and Low-Pressure Gauges
Listed RefrigerantsR134a / R404a / R22 / R12
Valve TypeDouble O-Ring Piston Valve
ApplicationsHVAC / Air Conditioning / Refrigeration Service

Brass Manifold Body for Professional HVAC Service

The manifold body is manufactured from brass, providing a durable service platform for compatible HVAC and refrigeration pressure testing and charging applications.

Corrosion Resistance

Brass provides useful corrosion resistance for professional HVAC service tools when the manifold is correctly used, stored and maintained.

Durable Valve Body

The metal manifold body provides structural support for the pressure gauges, valves and service hose connections.

Designed for Repeated Service Work

The product is positioned for professional technicians and contractors who routinely service air-conditioning and refrigeration equipment.

Analog High- and Low-Pressure Gauges

The DABUND manifold uses separate analog gauges for monitoring the low-pressure and high-pressure sides of compatible refrigeration systems.

Low-Side Gauge

The low-side gauge allows trained technicians to monitor suction-side pressure during compatible diagnostic and service procedures.

High-Side Gauge

The high-side gauge provides pressure information from the discharge or liquid side of compatible refrigeration systems when connected according to the equipment service procedure.

Clear Analog Reading

Analog dial gauges provide technicians with direct pressure readings during system commissioning, maintenance and troubleshooting.

Double O-Ring Piston Valve Design

The source product specification identifies a double O-ring piston valve design for the manifold.

Sealing Performance

The double O-ring design is intended to provide a controlled seal around the valve mechanism during compatible testing and charging procedures.

Smooth Valve Operation

Piston-style valve operation allows technicians to control manifold service ports during professional refrigeration work.

Refrigerant Compatibility

The source product specification lists the following refrigerants for this manifold gauge configuration:

  • R134a

  • R404a

  • R22

  • R12

Refrigerant compatibility should be verified against the exact gauge scale, hose connections, service-port requirements and pressure range of the manifold configuration being ordered.

Do not assume compatibility with refrigerants that are not listed for this product configuration without confirming the technical specification with the supplier.

Sight Glass for Refrigerant Monitoring

The source product description identifies a sight glass as one of the manifold features, allowing the technician to visually monitor refrigerant conditions during compatible service procedures.

Applications of the DABUND HVAC Manifold Gauge Set

Air Conditioning System Maintenance

Manifold gauges are used by trained HVAC technicians during compatible AC system diagnosis, refrigerant charging and maintenance procedures.

Refrigeration System Testing

The gauge set can be used to monitor refrigerant-side pressure in compatible refrigeration and cooling equipment.

HVAC Installation and Commissioning

During professional installation, a manifold gauge can form part of the service setup used for pressure monitoring, evacuation and refrigerant charging according to the equipment manufacturer's procedures.

HVAC Repair and Troubleshooting

High- and low-side pressure readings provide useful diagnostic information when trained technicians investigate abnormal HVAC or refrigeration system operation.

What to Check Before Ordering a Manifold Gauge Set

Confirm Refrigerant Type

Confirm that the required refrigerant is included on the gauge scale and supported by the manifold configuration.

Confirm Pressure Range

Verify that both high-side and low-side gauge ranges are suitable for the HVAC or refrigeration equipment being serviced.

Confirm Service-Port Connections

Check manifold and hose fitting sizes against the service connections used on the target equipment.

Confirm Hose Configuration

Confirm the number, length and connection type of the refrigerant hoses supplied with the ordered configuration.

Confirm Gauge Calibration Requirements

Professional users should confirm gauge calibration and inspection requirements according to their service procedures and local regulations.

Why Choose DABUND Refrigerant Gauge Manifold?

Brass Manifold Construction

The source product specification identifies brass as the manifold body material.

High- and Low-Side Analog Gauges

Separate analog gauges provide direct high- and low-side system pressure readings.

Double O-Ring Valve Design

Double O-ring piston valves are listed for controlled manifold operation during compatible HVAC service procedures.

Multi-Refrigerant Configuration

The source specification lists R134a, R404a, R22 and R12 for this gauge configuration.

Professional HVAC Applications

The manifold is positioned for technicians, contractors, service companies and distributors serving HVAC and refrigeration markets.

DABUND Manufacturing and Quality Control

Pressure Accuracy Inspection

The source page states that pressure accuracy is included in the product quality-control process.

Valve Sealing Inspection

Valve sealing is also listed among the quality-control checks.

Overall Performance Testing

Overall manifold performance is referenced as part of the inspection process before product supply.

OEM and ODM Manifold Gauge Services

DABUND lists OEM and ODM support for suitable distributors, importers and HVAC tool buyers.

  • Customized branding

  • Customized packaging

  • Product configuration customization

Buyers requiring customized gauges should confirm refrigerant scales, hose configuration, connection sizes, packaging and branding requirements before production.

Packaging and Delivery

  • Standard export packaging

  • Customized packaging available

  • Source-listed delivery time: approximately 15–20 days

Final production and delivery time should be confirmed according to order quantity, product configuration and customization requirements.

Safety Guidelines for Manifold Gauge Use

Refrigeration service should be performed by trained personnel using equipment and procedures appropriate for the specific refrigerant and HVAC system.

Verify Gauge Calibration

Check gauge condition and calibration before relying on pressure readings for service decisions.

Check Hose Connections

Confirm that refrigerant hoses and service connections are securely attached and compatible with the equipment before beginning service work.

Follow the Equipment Service Procedure

Operate manifold valves according to the HVAC equipment manufacturer's service instructions and the manifold gauge operating procedure.

Frequently Asked Questions

What is a refrigerant gauge manifold used for?

A refrigerant gauge manifold is used by HVAC technicians to monitor high- and low-side refrigerant pressure and assist with diagnostic, charging and evacuation procedures.

What refrigerants are listed for this DABUND manifold gauge?

The source product specification lists R134a, R404a, R22 and R12.

Is this an analog manifold gauge set?

Yes. The technical specification identifies analog high- and low-pressure gauges.

What material is the manifold body made from?

The source product specification lists brass as the manifold material.

What type of valve does the manifold use?

The technical specification lists a double O-ring piston valve design.

Can the manifold gauge be used for refrigerant charging?

Yes. Refrigerant charging is listed as one of the intended manifold functions when the tool is used by trained personnel according to the equipment manufacturer's service procedure.

Can the gauge set be used during system evacuation?

Yes. The source product description identifies evacuation as one of the HVAC service processes supported by a manifold gauge set.

Can a manifold gauge detect refrigerant leaks?

Pressure readings can help technicians identify abnormal system conditions that may indicate a refrigerant loss or other fault, but dedicated leak-detection procedures may still be required to locate an actual leak.

Does the manifold have a sight glass?

The source product description lists a sight glass for visually monitoring refrigerant conditions during compatible service procedures.

Is this manifold gauge suitable for professional HVAC technicians?

Yes. The product is positioned for HVAC technicians, contractors and refrigeration service professionals.

Can DABUND customize the manifold gauge set?

Yes. OEM and ODM options listed in the source include branding, packaging and product configuration customization.

What should I confirm before ordering?

Confirm the required refrigerant scales, gauge pressure ranges, hose configuration, service-port connection sizes and any OEM packaging or branding requirements.

What is the typical delivery time?

The source product information lists approximately 15–20 days. Final delivery time depends on quantity and customization requirements.

Is DABUND an HVAC manifold gauge supplier?

Yes. DABUND supplies refrigerant gauge manifolds and related HVAC tools and components for professional and distributor markets.

Related Products

Product name: Anti-vibration rubber pads Composition:natural rubber + carbon clack +anti-aging system. Scope:Home air conditiong Product Features:Hot galvanize screw, rubber material, durable Design, strong rubber Product Advantages: Anti-corrosion, shock absorber noise reduction, easy to install
1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 3/8"+3/4" 25 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts.  2. Both of the two copper pipe end do flaring and nuts.  3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm.  4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m.  5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200.  6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
Hot rolled plate construction,Strong and Durable. Anti-rusting,anti-corrosion and weather resistant,Perfect for long-term outdoor use. Fits most of mini split ductless air conditioner heat pump systems.  

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.