75 ft 1/4 in. x 3/8 in. Mini Split Line Set
DABUND 75 ft 1/4 in. x 3/8 in. Mini Split Line Set provides pre-insulated copper refrigerant tubing for compatible ductless air conditioners, heat pumps and split-system HVAC installations requiring an extended piping route.
The paired refrigerant tubing combines a 1/4 in. liquid line with a 3/8 in. suction line and provides a 75 ft length, approximately 22.9 m.
Manufactured from 99.9% pure seamless copper, the tubing is supplied with factory-applied Black Rubber insulation to help reduce thermal exchange, control condensation and simplify compatible HVAC installation.
Quick Answer: This 75 ft 1/4 x 3/8 mini split line set combines high-purity seamless copper tubing with Black Rubber insulation for compatible residential, ductless and heat-pump HVAC installations.
75 ft Mini Split Line Set Video
75 ft 1/4 x 3/8 Line Set Specifications
| Product Type | Pre-Insulated Mini Split Refrigerant Line Set |
| Line Set Size | 1/4 in. x 3/8 in. |
| Liquid Line | 1/4 in. / approximately 6.35 mm |
| Suction Line | 3/8 in. / approximately 9.52 mm |
| Length | 75 ft / approximately 22.9 m |
| Copper Material | 99.9% Pure Seamless Copper |
| Insulation | Factory-Applied Thermal Insulation |
| Featured Insulation | Black Rubber |
| Listed Insulation Temperature Range | -40°C to 120°C |
| Applications | Compatible Mini Split, Ductless AC, Heat Pump and Light Commercial HVAC Systems |
1/4 in. Liquid Line and 3/8 in. Suction Line
The paired copper refrigerant tubing combines a 1/4 in. liquid line with a 3/8 in. suction return line.
Before ordering, verify that the specific mini split or heat-pump system requires these exact refrigerant-line diameters.
Refrigerant piping should not be selected only by nominal BTU or tonnage because required liquid-line and suction-line sizes can vary between HVAC manufacturers and equipment models.
75 ft Length for Extended Mini Split Installations
The 75 ft line set provides additional routing flexibility where compatible indoor and outdoor HVAC equipment are separated by a longer distance than a standard short installation.
It can support compatible residential homes, apartments, offices, multi-zone projects and light commercial installations where shorter refrigerant lines do not provide sufficient reach.
Before installing a 75 ft refrigerant run, confirm the HVAC equipment manufacturer's maximum permitted piping length, allowable elevation difference and any additional refrigerant charging requirements.
99.9% Pure Seamless Copper Refrigerant Tubing
The source product information specifies 99.9% pure seamless copper construction for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and flexibility for routing compatible refrigerant piping through walls, ceilings and outdoor installation routes.
Proper bending methods and appropriate bend radii should be used to reduce the risk of kinking or flattening the tubing during installation.
Factory-Applied Black Rubber Insulation
The featured configuration uses Black Rubber insulation around the copper refrigerant tubing.
The source product information describes Black Rubber insulation as providing both a thermal insulation layer and a moisture-resistant layer, helping reduce condensation around cold refrigerant piping.
The listed operating temperature range for the Black Rubber insulation is approximately -40°C to 120°C.
Copper Line Set and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Protective Plastic Cap
Black Rubber Pipe Insulation
Black Rubber insulation helps reduce unwanted heat transfer between the refrigerant piping and the surrounding environment.
Its moisture-resistant structure helps reduce condensation on cold copper tubing and limits moisture exposure around the refrigerant piping route.

Benefits of the 75 ft Mini Split Line Set
Extended Installation Reach
The 75 ft length provides additional routing flexibility where compatible indoor and outdoor HVAC units cannot be installed close together.
Reduced Thermal Exchange
Factory-applied insulation helps reduce unwanted heat exchange between the refrigerant tubing and surrounding air.
Condensation Control
Black Rubber insulation helps reduce surface condensation on cold refrigerant tubing and protects the surrounding installation area from moisture exposure.
Flexible Copper Routing
Seamless copper tubing can be routed through compatible walls, ceilings and exterior paths when suitable HVAC bending methods are used.
Compatible HVAC Applications
Compatible residential split air conditioners
Ductless mini split systems
Heat-pump refrigerant lines
Multi-zone ductless systems
Retrofit and replacement HVAC projects
Light commercial air-conditioning installations
Final compatibility should be confirmed from the HVAC equipment manufacturer's required liquid-line size, suction-line size, maximum permitted piping length and installation instructions.
Important Considerations for a 75 ft Refrigerant Run
Verify Maximum Permitted Line Length
Confirm that the specific mini split or heat-pump system permits at least the required 75 ft refrigerant piping route before installation.
Confirm the Exact Pipe Sizes
Verify that the selected HVAC equipment specifically requires a 1/4 in. liquid line and 3/8 in. suction line.
Check Maximum Elevation Difference
If indoor and outdoor equipment are installed at different heights, confirm the maximum vertical separation permitted by the equipment manufacturer.
Check Additional Refrigerant Requirements
Additional refrigerant may be required depending on the HVAC equipment, factory refrigerant charge and total installed piping length. Follow the equipment manufacturer's charging instructions.
Support the Refrigerant Line
Use suitable HVAC-rated clips, straps or supports along the route to reduce sagging, vibration and mechanical stress on the tubing and insulation.
Installation Guidelines
Measure the Required Line Length
Measure the complete refrigerant piping route before cutting or installing the copper tubing.
Avoid Sharp Bends and Kinks
Use suitable tube-bending methods and bend radii to reduce the risk of copper tube deformation or restricted refrigerant flow.
Use Proper Flaring and Sealing
If the tubing is shortened, use appropriate HVAC cutting, deburring, flaring and sealing procedures before making refrigerant connections.
Maintain Continuous Insulation Coverage
Avoid cutting, crushing or leaving unnecessary gaps in the Black Rubber insulation, especially at bends, supports and wall penetrations.
Pressure Test Before Startup
Follow the HVAC equipment manufacturer's approved pressure-testing, evacuation and commissioning procedures before system startup.

Available Mini Split Line Set Sizes
| Line Set Size | Available Lengths | Black Rubber Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: The wider product family table lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths. This specific SKU is approximately 22.9 m, so buyers should confirm the exact 75 ft configuration when ordering.
General Line Set Size and Capacity Reference
The following capacity ranges are general references from the wider DABUND mini split line set family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact piping requirements.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
For the 1/4 x 3/8 configuration, the DABUND product family lists 0.75–1.0 ton and 9,000–12,000 BTU as general references. Actual compatibility must be confirmed from the HVAC equipment manufacturer's exact refrigerant piping requirements.
Why Choose the DABUND 75 ft 1/4 x 3/8 Line Set?
Extended 75 ft Refrigerant Run
The extended length provides routing flexibility for compatible projects requiring greater separation between indoor and outdoor HVAC equipment.
99.9% Pure Seamless Copper
High-purity seamless copper construction provides flexible refrigerant tubing for compatible residential and light commercial HVAC projects.
Black Rubber Insulation
Factory-applied Black Rubber insulation provides thermal protection and helps control condensation around cold refrigerant tubing.
Multiple Production Options
The wider DABUND line set family offers multiple tube-size combinations, lengths and insulation thicknesses for distributor and project requirements.
DABUND Mini Split Line Set Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC products for distributors, contractors and project customers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber mini split line set insulation references ASTM E84, UL94, ASTM D1056 and ASTM G21.
Buyers requiring project-specific compliance documentation should confirm the selected Black Rubber insulation thickness and corresponding test report before ordering.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where distributors and professional buyers can review mini split line sets, insulated copper tubing and related HVAC products.

Frequently Asked Questions
What does 1/4 in. x 3/8 in. mean?
It refers to the outside diameters of the two refrigerant tubes: 1/4 in. for the liquid line and 3/8 in. for the suction return line.
How long is this mini split line set?
The line set is 75 ft long, approximately 22.9 m.
What material is the refrigerant tubing made from?
The source product information specifies 99.9% pure seamless copper.
What insulation material is used?
The featured product configuration uses Black Rubber insulation.
What is the listed Black Rubber insulation temperature range?
The source product information lists approximately -40°C to 120°C.
What Black Rubber insulation thicknesses are available?
The wider product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thicknesses.
What size mini split can use a 1/4 x 3/8 line set?
The DABUND product family lists 1/4 x 3/8 as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU systems. Final pipe sizing must follow the HVAC equipment manufacturer's exact requirements.
Is this line set compatible with every mini split brand?
Universal compatibility should not be assumed. Confirm the required liquid-line diameter, suction-line diameter, permitted piping length and connection requirements for the specific HVAC model.
Can every mini split use a 75 ft refrigerant line?
No. Verify the equipment manufacturer's maximum permitted refrigerant piping length and allowable elevation difference before installation.
Does a 75 ft line set require additional refrigerant?
Additional refrigerant may be required depending on the HVAC equipment, factory refrigerant charge and total installed piping length. Follow the equipment manufacturer's charging instructions.
Can the copper line set be shortened?
Yes. The source product information states that the copper tubing can be trimmed to suit specific installation lengths. Proper HVAC cutting, deburring, re-flaring and sealing procedures should be used after modification.
Does the line set need additional insulation?
The line set is factory pre-insulated. Additional protection may still be required depending on outdoor exposure, wall penetrations, local installation requirements or project specifications.
Can the line set be installed outdoors?
The source product information describes the insulation jacket as UV- and moisture-resistant. Final outdoor suitability should be confirmed for the selected configuration and exposure conditions.
What other mini split line set sizes are available?
Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
What production lengths are available?
The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths. This specific product is approximately 22.9 m, so confirm the 75 ft SKU when ordering.
Is DABUND a manufacturer?
Yes. The source product information identifies DABUND as a manufacturer of mini split line sets, insulated copper pipe and related HVAC products.
Can DABUND provide free samples?
Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer responsible for express freight. View Sample Information
What payment terms are available?
Listed payment options include T/T, L/C at sight and credit card.
What delivery terms are available?
Listed delivery terms include EXW, FOB, CFR and CIF.
Does DABUND support OEM and ODM?
Yes. OEM and ODM services, including logo customization, are available for suitable orders.
What is the typical delivery time?
The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.