Home Copper Pipe Insulated Copper Tubing 1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1/2" x 3/4" x 75 ft Insulated Copper Tubing for HVAC & Air Conditioning Systems
1. 1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

Insulated Copper Tubing

Application

HVAC
Inquire
Add to Basket

75 ft 1/2 in. x 3/4 in. Insulated Copper Tubing

The DABUND 75 ft 1/2 in. x 3/4 in. Insulated Copper Tubing is a pre-insulated HVAC refrigerant line set for compatible mini split systems, heat pumps, central air-conditioning systems and refrigeration applications requiring extended piping routes.

The paired line set combines a 1/2 in. liquid line with a 3/4 in. suction line and provides a continuous 75 ft length, equal to 22.86 m, for longer indoor-to-outdoor refrigerant connections.

The source product information specifies 99.9% pure copper and references ASTM B280 and C12200 according to product specification. Black Rubber is the primary insulation configuration shown on this page, while PE and Polypropylene insulation options are also available.

Quick Answer: This 75 ft 1/2 x 3/4 pre-insulated copper line set is intended for compatible HVAC and refrigeration equipment requiring these exact pipe sizes. The source narrative references selected 3–6 ton systems, but the wider family capacity table does not provide a specific Ton or BTU mapping for 1/2 x 3/4, so final selection should follow the equipment manufacturer's installation manual.

75 ft Insulated Copper Tubing Video

75 ft 1/2 x 3/4 Copper Tubing Specifications

Product TypePre-Insulated HVAC Copper Line Set
Liquid Line1/2 in. / 12.70 mm
Suction Line3/4 in. / 19.05 mm
Length75 ft / 22.86 m
Copper Material99.9% Pure Copper
Copper StandardsASTM B280 / C12200 according to product specification
Featured InsulationBlack Rubber
Other Insulation OptionsPE / Polypropylene
Listed Temperature Range-40°C to 120°C; confirm for exact insulation configuration
Source-Listed Pressure Range2100–7000 PSI according to specification; actual allowable pressure depends on tube dimensions, wall thickness and temperature
Referenced RefrigerantsR410A / R32 when copper and equipment specifications match
ApplicationsCompatible Mini Split / Heat Pump / Central HVAC / Refrigeration Systems

1/2 in. Liquid Line and 3/4 in. Suction Line

This paired HVAC line set uses a 1/2 in. liquid line and a 3/4 in. suction line.

The configuration is intended for compatible equipment where the HVAC or refrigeration manufacturer specifically requires these refrigerant-line diameters.

Do not select the line set by nominal system tonnage alone. Pipe-size requirements vary by equipment model, refrigerant and system design.

75 ft Length for Extended HVAC Installations

The continuous 75 ft length equals 22.86 m and provides additional routing flexibility for compatible projects where indoor and outdoor equipment are separated by a greater distance.

Typical project environments may include rooftop HVAC units, multi-story buildings, large residential installations and commercial HVAC projects.

A continuous copper line can reduce unnecessary intermediate connections compared with joining multiple shorter sections, provided the complete route remains within the HVAC equipment manufacturer's permitted piping limits.

99.9% Pure Copper Refrigerant Tubing

The source page specifies 99.9% pure copper for this insulated refrigerant line set.

Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC and refrigeration piping applications.

ASTM B280 and C12200

ASTM B280 and C12200 are referenced according to product specification. Buyers requiring project documentation should confirm the exact copper tube dimensions, wall thickness and corresponding technical documentation for the ordered configuration.

Pressure Capability for R410A and R32 Applications

The source page lists a pressure range of approximately 2100–7000 PSI according to specification and references R410A and R32 applications.

Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and exact product configuration. Confirm the applicable engineering data before specifying the product for a particular HVAC or refrigeration system.

Factory-Applied HVAC Insulation

Factory-applied insulation surrounds the copper tubing and reduces additional field insulation work.

The source page lists high-density Polypropylene, PE and Rubber insulation options depending on the selected product specification.

UV-Resistant Configurations

UV-resistant insulation configurations are referenced for compatible outdoor installations. Final suitability depends on the exact insulation material, thickness and environmental exposure conditions.

Listed Temperature Range

Applicable insulation configurations are listed with a temperature range of approximately -40°C to 120°C. Confirm the rating for the exact ordered material.

Moisture and Condensation Protection

Closed-cell insulation helps reduce moisture penetration and surface condensation around cold refrigerant piping.

Triple-Layer Insulation Structure

The source describes a multi-layer structure for applicable PE insulation configurations.

Outer UV-Resistant PE Layer

UV-resistant PE film is referenced as the outer protective layer.

Middle IXPE Foam Layer

IXPE foam is referenced as the middle thermal-insulation layer.

Inner Closed-Cell Layer

A closed-cell airtight inner layer is referenced for thermal and moisture protection.

Typical HVAC Applications

  • Compatible mini split air conditioners

  • Heat-pump systems

  • Central air-conditioning systems

  • Residential HVAC installations

  • Commercial HVAC projects

  • Compatible refrigeration systems

  • Long-distance refrigerant-line installations where equipment limits permit

HVAC Capacity Selection for 1/2 x 3/4 Tubing

The source narrative states that 1/2 x 3/4 tubing may be used in selected larger HVAC systems and references an approximate 3–6 ton / 36,000–72,000 BTU range depending on equipment configuration.

However, the wider product-family capacity table does not provide a dedicated capacity mapping for the 1/2 x 3/4 configuration.

For this reason, system capacity should only be treated as a secondary reference. Final selection should be based on the equipment manufacturer's specified 1/2 in. liquid line and 3/4 in. suction line requirements.

Copper Line Set and Insulation Video

99.9 percent pure copper for 75 ft insulated copper tubing

99.9% Pure Copper

Black Rubber insulated 1/2 x 3/4 HVAC copper tubing

Black Rubber Insulated Pipe

plastic cap protection for AC copper pipe line set

Plastic Cap Protection

Black Rubber Insulation

Black Rubber is the primary insulation configuration shown in the product imagery and wider product-family table.

The source describes Black Rubber as providing both thermal insulation and moisture-resistant functions in one structure.

Thermal Protection

The insulation helps limit unwanted heat transfer around the refrigerant tubing.

Moisture Control

The Black Rubber configuration is described as combining insulation and moisture-resistant functions, helping reduce surface condensation in compatible HVAC applications.

Black Rubber insulation structure for insulated copper tubing

Technical Specifications

FeatureDetails
Product Name1/2 in. x 3/4 in. x 75 ft Insulated Copper Tubing
Product TypePre-Insulated HVAC Copper Line Set
Length75 ft / 22.86 m
Liquid Line1/2 in. / 12.70 mm
Suction Line3/4 in. / 19.05 mm
Material99.9% Pure Copper
InsulationUV-Resistant / Flame-Retardant Options According to Specification
Listed Temperature Range-40°C to 120°C
Source-Listed Pressure Range2100–7000 PSI according to specification
StandardsASTM B280 / C12200 according to product specification

OEM and Custom Insulated Copper Tubing

  • Custom insulation colors including black and white

  • Logo printing on insulation

  • Custom line-set lengths

  • Custom copper pipe-size combinations

  • Custom insulation thickness

  • Private-label packaging

  • Bulk supply for distributors and contractors

  • OEM and ODM manufacturing support

Black Rubber Copper Line Set

75 ft 1/2 x 3/4 Black Rubber insulated copper tubing

Insulated Copper Tubing Size Options

SizeStandard Family LengthsBlack Rubber InsulationListed Flame-Resistance Options
1/4 + 3/8 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 1/2 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 5/8 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 5/8 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 3/4 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2 + 3/4 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 7/8 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

Length Note: This specific SKU is 75 ft / 22.86 m. The wider family table lists 20 m and 25 m as nearby standard metric production lengths, so buyers should specify the exact finished 75 ft configuration when ordering.

General Line Set Size and Capacity Reference

Line Set SizeGeneral Ton / HP RangeGeneral BTU RangeTypical Application
1/4 + 3/8 in.0.75–1.0 Ton / 0.75P–1P9,000–12,000 BTUSmall Mini Split AC
1/4 + 1/2 in.1.5–2.0 Ton / 1.5P–2P12,000–18,000 BTUMedium Mini Split AC
1/4 + 5/8 in.2.0–2.5 Ton / 2P–2.5P24,000–30,000 BTUSplit AC / Heat Pump
3/8 + 5/8 in.3.0–4.0 Ton / 3P–4P36,000–48,000 BTUDuctless Commercial AC
3/8 + 3/4 in.4.5–6.0 Ton / 4.5P–6P54,000–72,000 BTULarge Split AC
3/8 + 7/8 in.6.0–8.0 Ton / 6P–8P72,000–96,000 BTUHigh-Capacity Ductless HVAC

Important: The source family capacity table does not provide a specific Ton or BTU mapping for 1/2 + 3/4 in. tubing. Final line sizing should therefore be based on the equipment manufacturer's required pipe dimensions.

Important Checks for a 75 ft Refrigerant Run

Confirm Exact Pipe Sizes

Verify that the selected HVAC or refrigeration equipment specifically requires a 1/2 in. liquid line and 3/4 in. suction line.

Verify Maximum Permitted Piping Length

Confirm that the equipment manufacturer permits a 75 ft refrigerant piping route.

Check Minimum Permitted Piping Length

Some equipment also specifies a minimum refrigerant piping length. Confirm both minimum and maximum limits before installation.

Check Maximum Elevation Difference

If indoor and outdoor equipment are installed at different elevations, verify the manufacturer's maximum permitted vertical separation.

Check Additional Refrigerant Charge

A 75 ft refrigerant run may require additional refrigerant beyond the equipment's factory charge. Follow the equipment manufacturer's charging instructions for the actual installed length.

Check Equivalent Piping Length

Bends, fittings and elevation changes may increase equivalent piping length beyond the physical 75 ft tubing length. Follow the manufacturer's engineering limits for the complete route.

Support Long Pipe Runs

Use appropriate HVAC clamps, straps or brackets to reduce sagging, vibration, insulation compression and mechanical stress along extended runs.

Installation Guidelines

Plan the Complete Routing Path

Measure and plan the complete refrigerant route before uncoiling, cutting or modifying the copper tubing.

Avoid Sharp Bends and Kinks

Use suitable HVAC tube-bending methods and appropriate bend radii to reduce the risk of copper deformation or refrigerant-flow restriction.

Protect the Insulation

Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and building penetrations.

Keep Copper Ends Protected

Keep open copper tube ends capped or sealed before final connection to reduce moisture, dust and contamination entering the refrigerant circuit.

Pressure Test and Evacuate Before Startup

Refrigerant piping should be properly connected, leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.

DABUND Insulated Copper Tubing Production

DABUND manufactures insulated copper tubing, mini split line sets, installation kits and related HVAC components for distributors, contractors, wholesalers and OEM customers.

DABUND Black Rubber insulated copper tubing production

Insulation Test Documentation

The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations can meet ASTM E84, UL94, ASTM D1056 and ASTM G21 requirements according to product specification.

Because Black Rubber is the primary configuration shown on this page, the certificate description is more closely aligned with the featured insulation type. Buyers should still confirm the exact insulation material, thickness and matching test report for the ordered configuration.

SGS certificate for DABUND insulated copper tubing

International HVAC Exhibitions

DABUND participates in international HVAC exhibitions where professional buyers can review insulated copper tubing, mini split line sets and related HVAC products.

DABUND insulated copper tubing at international HVAC exhibition

Frequently Asked Questions

What is 1/2 x 3/4 x 75 ft insulated copper tubing used for?

It is used as pre-insulated refrigerant piping between compatible HVAC or refrigeration equipment requiring a 1/2 in. liquid line and 3/4 in. suction line.

How long is this insulated copper tubing?

This SKU is 75 ft long, equal to 22.86 m.

What HVAC capacity uses a 1/2 x 3/4 line set?

The source narrative references selected 3–6 ton / 36,000–72,000 BTU systems, but the wider family capacity table does not provide a dedicated mapping for 1/2 x 3/4. Final selection must therefore follow the equipment manufacturer's required pipe sizes.

What copper material is used?

The source page specifies 99.9% pure copper and references ASTM B280 and C12200 according to product specification.

What insulation options are available?

Black Rubber, PE and Polypropylene insulation options are referenced. Black Rubber is the primary configuration shown on this page.

What insulation thicknesses are available?

The wider Black Rubber family table lists insulation thicknesses of 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.

What is the listed temperature range?

The source page lists approximately -40°C to 120°C for applicable insulation configurations. Confirm the applicable rating for the exact ordered material.

What is the pressure rating?

The source page lists a 2100–7000 PSI range according to specification. Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and exact configuration.

Can this tubing be used with R410A or R32?

R410A and R32 are referenced on the source page. Final compatibility depends on pipe size, wall thickness, allowable working pressure, piping length and HVAC equipment requirements.

Is 75 ft suitable for every HVAC installation?

No. Confirm the HVAC equipment manufacturer's minimum and maximum permitted piping lengths, elevation limits and additional refrigerant-charge requirements before installation.

Does a 75 ft refrigerant run require additional refrigerant?

Additional refrigerant may be required depending on the equipment's factory charge and included piping allowance. Follow the equipment manufacturer's charging instructions for the actual installed length.

Can this insulated copper tubing be used outdoors?

UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation material and exposure conditions.

Can DABUND customize the insulated copper tubing?

Yes. DABUND supports custom insulation colors, insulation thickness, line-set lengths, copper pipe sizes, logo printing and private-label packaging.

Who typically buys this product?

The product is intended for HVAC contractors, installers, distributors, wholesalers, importers, refrigeration project buyers and private-label HVAC brands.

Is professional HVAC installation recommended?

Yes. Refrigerant piping should be installed, connected, leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.

Related Products

Please select a data source

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.