Home Line Set Cover Line Set Cover Kit Line Set Cover Kit Flexible Duct for Mini Split AC
Line Set Cover Kit Flexible Duct for Mini Split AC
Line Set Cover Kit Flexible Duct for Mini Split AC
Line Set Cover Kit Flexible Duct for Mini Split AC
Line Set Cover Kit Flexible Duct for Mini Split AC
Line Set Cover Kit Flexible Duct for Mini Split AC
Line Set Cover Kit Flexible Duct for Mini Split AC
Line Set Cover Kit Flexible Duct for Mini Split AC
Line Set Cover Kit Flexible Duct for Mini Split AC
Features:
Easy to install, all parts can be separate in the middle for quick installation
Fit for Any previous and existing house building
Made of High quality PVC, great protects the pipes
Works with most most Central Air Conditioner system, Heat Pump, Ductless Mini Split using.
  • DBJ-010

  • DABUND

  • PVC

Application

Mini Split Air Conditioner

Color

White
Inquire
Add to Basket

PVC Flexible Duct for Mini Split Line Set Cover

DABUND Line Set Cover Flexible Duct is a PVC accessory designed for compatible ductless mini split, heat pump and central air-conditioning line set cover systems.

The flexible section is designed for installation routes where a straight duct or fixed-angle fitting is not suitable, helping the protective cover follow difficult or irregular piping paths while continuing to conceal refrigerant pipes, insulation and electrical wiring.

The current product information describes the line set cover components as being made from high-quality PVC in a light beige color, with heat resistance, flexibility, corrosion resistance and protection against outdoor weather and UV exposure.

Quick Answer: This PVC Flexible Duct is a line set cover accessory for routing protected mini split piping through difficult installation areas where a flexible transition is needed.

Flexible Duct Product Overview

Product TypeLine Set Cover Flexible Duct
MaterialPVC
ColorLight beige according to current product information
Main FunctionFlexible transition for difficult or irregular HVAC line set cover routes
Protected ComponentsRefrigerant pipes, insulation and electrical wiring
ApplicationsDuctless mini split, heat pump and central air-conditioning systems
Installation DesignDesigned for flexible routing around difficult installation areas
Outdoor ProtectionWeather and UV resistance are referenced in the current product information

Flexible Transition for HVAC Line Set Covers

Not every refrigerant piping route can be covered using only straight ducts and fixed-angle fittings. The Flexible Duct is intended for sections where the line set cover needs to follow a more difficult installation path.

The current product information specifically describes the line set cover system as being designed for easier bending over and around difficult applications.

This allows the cover system to continue protecting the enclosed copper pipes and wiring while adapting to changes in the installation route.

Durable PVC Construction

The current product information identifies high-quality PVC as the material used for the flexible duct and related line set cover components.

Heat resistance, flexibility and corrosion resistance are listed among the product characteristics for compatible HVAC installations.

PVC flexible duct for mini split line set cover

Designed for Difficult Installation Routes

The Flexible Duct is intended for installation sections where rigid straight ducts or fixed fittings cannot easily follow the required route.

The current product description emphasizes flexibility and suitable internal space for compatible copper piping, allowing the protective cover system to adapt around difficult areas.

Mini split flexible PVC line set cover system

Protects Copper Pipes and Wiring

The PVC line set cover system helps conceal and protect refrigerant piping, pipe insulation and electrical wiring between compatible indoor and outdoor HVAC equipment.

Flexible Duct allows that protective enclosure to continue through installation sections that require more adaptable routing than a rigid straight duct can provide.

Flexible HVAC PVC line set cover accessory for refrigerant piping

Easy Installation

The current product information states that components within the line set cover system can be separated in the middle for faster installation.

This construction supports compatible new installations and retrofit projects where refrigerant lines and electrical wiring are already installed.

Flexible PVC HVAC duct fitting for mini split line set cover

Weather and UV Protection

The current product information describes the PVC line set cover system as suitable for outdoor use and as helping protect the enclosed piping from weather exposure and UV radiation.

Exact UV-aging test data, outdoor service-life values and operating-temperature limits are not supplied in the current source and should be confirmed if required for a project specification.

Flexible Duct Applications

The Flexible Duct is intended for use as part of compatible PVC line set cover systems in:

  • Ductless mini split air-conditioning installations

  • Heat-pump installations

  • Central air-conditioning piping installations

  • HVAC line set routes with irregular transitions

  • Installation paths around obstacles

  • Exterior refrigerant-pipe protection systems

  • HVAC wiring and pipe concealment systems

  • New construction and retrofit projects

Why Use a Flexible Duct Fitting?

Straight ducts are suitable for linear sections, while fixed elbows and bends are used for defined changes in direction.

A Flexible Duct is useful where the actual installation route cannot be matched easily by a standard rigid fitting.

It provides a more adaptable connection between sections of the cover system while helping maintain protection and concealment of the enclosed piping.

Flexible Duct vs Other Line Set Cover Fittings

ComponentPrimary Function
Flexible DuctProvides an adaptable transition for difficult or irregular installation routes
Straight DuctCovers straight sections of piping and wiring
Upright BendProvides a fixed directional transition
Wall CoverFinishes the transition around a wall-entry or wall-exit section
End CapFinishes the end section of the protective cover system

How to Select the Correct Flexible Duct

Confirm the Matching Line Set Cover Size

The Flexible Duct should match the size and profile of the straight PVC line set cover used in the installation.

Confirm the Pipe Bundle Size

Measure the combined outside dimensions of the insulated refrigerant pipes, electrical wiring and any additional components that need to pass through the flexible cover section.

Confirm the Required Route

Review the actual installation path and identify the section where a flexible transition is required instead of a straight duct or fixed-angle fitting.

Confirm the Required Flexible Length

The current source does not provide the available Flexible Duct lengths. Confirm the required length according to the installation route before ordering.

Confirm Compatibility with Other Fittings

Confirm that the Flexible Duct connects correctly with the straight ducts and other fittings in the complete line set cover system.

Information to Confirm Before Ordering

HVAC distributors, wholesalers, contractors and installers should confirm:

  • Required Flexible Duct size

  • Matching straight duct size

  • Required Flexible Duct length

  • Line set outside dimensions

  • Installation route

  • Required transition shape

  • Number of Flexible Duct sections required

  • Other required line set cover fittings

  • Required color

  • Order quantity

  • Packaging requirements

  • OEM or private-label requirements

The current product information does not provide the Flexible Duct length, width, height, minimum bending radius, allowable bending angle, PVC thickness or matching duct-size table. Confirm these dimensions for the exact product before ordering.

Flexible Line Set Cover Fittings for HVAC Distributors

DABUND has supplied HVAC installation products since 2008, including PVC line set covers and related installation accessories.

OEM and ODM requirements can be discussed according to fitting configuration, packaging and commercial purchasing requirements.

Frequently Asked Questions

What is a Flexible Duct for a mini split line set cover?

It is a flexible PVC accessory used in a compatible line set cover system where the protective duct needs to follow a difficult or irregular installation route.

What material is the Flexible Duct made from?

The current product information identifies PVC as the material.

What color is the Flexible Duct?

The current source describes the line set cover components as light beige.

When should I use a Flexible Duct instead of a rigid bend?

A Flexible Duct is useful where the installation route cannot be followed easily with a straight duct or fixed-angle fitting and a more adaptable transition is required.

Is it suitable for ductless mini split systems?

Yes. Ductless mini split systems are specifically listed among the intended applications.

Can it be used with heat pumps?

Yes. Heat-pump applications are included in the current product information.

Can it be used with central air conditioning?

Central air-conditioning systems are also referenced, provided the cover-system dimensions match the piping installation.

Can it protect electrical wires as well as refrigerant pipes?

Yes. The current product description specifically refers to protecting and concealing both pipes and wires.

Is the Flexible Duct suitable for outdoor installation?

The current product information describes the PVC line set cover system as suitable for outdoor environments and as helping protect piping from weather and UV exposure.

Can it be installed around existing line sets?

The current source states that components in the line set cover system can be separated for easier installation around compatible existing piping.

What size Flexible Duct do I need?

Match the Flexible Duct to the straight cover size and make sure it provides sufficient internal space for the insulated refrigerant lines and electrical wiring.

What is the minimum bending radius?

The current product information does not provide a numerical minimum bending radius. Confirm the allowable bending range for the exact Flexible Duct before ordering or installation.

Is this a complete line set cover kit?

No. This page focuses on the Flexible Duct accessory. Straight ducts and other fittings should be selected according to the complete installation route.

Can DABUND provide OEM or ODM Flexible Ducts?

Yes. OEM and ODM requirements can be discussed according to product configuration, packaging and commercial purchasing requirements.

Is DABUND a manufacturer?

Yes. The current product information identifies DABUND as the manufacturer.

Can I request a sample?

Sample requests can be discussed according to the current sales policy.    View sample information.

What payment terms are available?

Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.

What delivery terms are available?

Available international trade terms can include EXW, FOB, CFR and CIF.

What is the typical delivery time?

The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on product configuration, order quantity, customization and production schedule.

Related Products

1. 1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 3/8"+3/4" 15 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts.  2. Both of the two copper pipe end do flaring and nuts.  3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm.  4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m.  5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200.  6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 3/8"+5/8" 25 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts.  2. Both of the two copper pipe end do flaring and nuts.  3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm.  4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m.  5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200.  6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 3/8"+3/4" 10 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts.  2. Both of the two copper pipe end do flaring and nuts.  3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm.  4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m.  5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200.  6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.