50 ft 3/8 in. x 5/8 in. Mini Split Line Set
DABUND 50 ft 3/8 in. x 5/8 in. Mini Split Line Set is a pre-insulated copper refrigerant line designed for compatible mini split air conditioners, ductless heat pumps and HVAC systems.
The line set combines a 3/8 in. liquid line with a 5/8 in. suction line and provides a continuous 50 ft refrigerant piping length, approximately 15.24 m.
The refrigerant tubing is manufactured from 99.9% pure copper and supplied with factory-applied Black Rubber insulation to help reduce thermal exchange, control condensation and protect the tubing during HVAC installation and operation.
Quick Answer: This 50 ft 3/8 x 5/8 mini split line set combines pre-insulated copper refrigerant tubing with Black Rubber insulation for compatible ductless AC, heat-pump and HVAC applications.
50 ft 3/8 x 5/8 Line Set Specifications
| Product Type | Pre-Insulated Mini Split Refrigerant Line Set |
| Line Set Size | 3/8 in. x 5/8 in. |
| Liquid Line | 3/8 in. / approximately 9.52 mm |
| Suction Line | 5/8 in. / approximately 15.88 mm |
| Length | 50 ft / approximately 15.24 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standards | ASTM B280 / C12200 |
| Insulation | Factory-Applied, UV-Resistant |
| Featured Insulation | Black Rubber |
| Listed Insulation Temperature Range | -40°C to 120°C |
| Source Pressure Reference | 2100–7000 PSI source reference range; confirm exact working and burst pressure for the selected configuration |
| Applications | Compatible mini split, ductless AC, heat pump and HVAC installations |
| Listed Refrigerants | R410A, R32 and similar compatible HVAC refrigerants |
50 ft Mini Split Line Set Video
3/8 in. Liquid Line and 5/8 in. Suction Line
This refrigerant line set combines a 3/8 in. liquid line for refrigerant feed with a 5/8 in. suction line for vapor return.
Both tube sizes should be verified against the HVAC equipment manufacturer's installation manual before ordering because refrigerant-line dimensions vary by equipment model and system design.
50 ft Length for Flexible HVAC Installation
The 50 ft continuous line length provides additional routing flexibility where the indoor and outdoor HVAC units are separated by a moderate distance.
A continuous coil can reduce the need for intermediate refrigerant-line connections compared with joining multiple shorter tubing sections.
Before installation, confirm that 50 ft is within the equipment manufacturer's maximum permitted refrigerant piping length and elevation requirements.
99.9% Pure Copper Refrigerant Tubing
The line set uses 99.9% pure copper tubing and references ASTM B280 and C12200 for HVAC refrigerant piping applications.
Copper provides thermal conductivity, corrosion resistance and the flexibility required for routing between compatible indoor and outdoor HVAC equipment.
Factory-Applied Black Rubber Insulation
The featured 50 ft line set uses Black Rubber insulation around the copper refrigerant tubing.
Factory-applied insulation helps reduce unwanted heat gain or heat loss and helps limit surface condensation on cold refrigerant piping.
The source product information lists the Black Rubber insulation for a temperature range of -40°C to 120°C and describes the insulation as providing both thermal and moisture protection.
Copper Line Set and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Protective Plastic Cap
Black Rubber Insulation Details
Black Rubber insulation provides both thermal protection and moisture resistance around the copper refrigerant tubing.
The listed temperature range for this insulation configuration is -40°C to 120°C.
The factory-applied insulation reduces the need for additional field wrapping while providing consistent coverage along the line set.

Benefits of This Mini Split Line Set
Reduced Field Insulation Work
Factory-applied insulation reduces additional insulation wrapping during installation and provides consistent coverage around the copper tubing.
Condensation Control
Proper insulation helps reduce surface condensation on cold refrigerant piping and limits moisture exposure to walls, ceilings and nearby building materials.
Thermal Protection
The insulation helps reduce unwanted thermal exchange between the refrigerant piping and the surrounding environment during cooling and heating operation.
Continuous 50 ft Refrigerant Run
The continuous 50 ft coil can simplify compatible installations by reducing the need for intermediate tubing extensions or connections.
50 ft Black Rubber Mini Split Line Set
The featured Black Rubber configuration combines factory-insulated copper refrigerant tubing with a 50 ft continuous coil for compatible mini split and HVAC projects.

Available Mini Split Line Set Sizes
The following table shows the sizes, production lengths and Black Rubber insulation options listed for the wider DABUND mini split line set family.
| Line Set Size | Available Lengths | Black Rubber Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
General Line Set Size and Capacity Reference
The following capacity ranges are general references listed for the wider DABUND mini split line set family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact piping specifications.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000 / 12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000 / 18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000 / 30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000 / 48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000 / 72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
For the 3/8 x 5/8 combination, the DABUND product family lists 3.0–4.0 ton and 36,000–48,000 BTU as general references. Final selection must be based on the HVAC equipment manufacturer's required liquid-line and suction-line dimensions.
Compatible HVAC Applications
Compatible mini split air conditioners
Ductless heat-pump systems
Residential HVAC installations
Light commercial HVAC installations
Compatible extended refrigerant piping runs
Refrigerant Compatibility
The source product information lists R410A and R32 among the common refrigerants used with compatible mini split and ductless HVAC systems.
Final refrigerant compatibility, working pressure, required tubing dimensions and connection requirements should be verified against the specific equipment manufacturer's technical documentation.
Important Considerations for a 50 ft Mini Split Line Set
Verify the Maximum Permitted Line Length
Confirm that the HVAC equipment manufacturer permits a total refrigerant piping length of at least 50 ft.
Check the Maximum Elevation Difference
Where the indoor and outdoor units are installed at different elevations, confirm the maximum vertical separation permitted by the equipment manufacturer.
Check Additional Refrigerant Requirements
Depending on the HVAC equipment and total refrigerant-line length, an additional refrigerant charge may be required. Follow the manufacturer's charging instructions.
Confirm the Exact Pipe Sizes
Confirm that the equipment specifically requires a 3/8 in. liquid line and 5/8 in. suction line before ordering.
Installation Guidelines
Plan the Refrigerant Line Route
Measure and plan the complete route between indoor and outdoor units before installation to confirm that the 50 ft line set provides sufficient length.
Avoid Sharp Bends and Kinks
Route the copper tubing with suitable bend radii to reduce the risk of kinking or restricting refrigerant flow.
Protect Insulation at Wall Penetrations
Use suitable wall sleeves or protective grommets where the insulated line set passes through walls or other structural penetrations.
Support the Refrigerant Lines
Use suitable line clamps, straps or HVAC support brackets along the piping route to reduce sagging, vibration and mechanical stress on the tubing and insulation.
Follow the Equipment Manufacturer's Instructions
Refrigerant piping, connections, evacuation, charging and commissioning should follow the HVAC equipment manufacturer's installation instructions.
DABUND Mini Split Line Set Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation products for distributors and project customers.

Insulation Test Documentation
The source product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber insulation configurations.
Buyers requiring specific project documentation should confirm the selected insulation material, insulation thickness and corresponding test reports before ordering.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where distributors and professional buyers can review mini split line sets, insulated copper tubing and related HVAC installation products.

Frequently Asked Questions
What does 3/8 in. x 5/8 in. mean?
It refers to the listed outside diameters of the refrigerant tubes: 3/8 in. for the liquid line and 5/8 in. for the suction line.
How long is this mini split line set?
The line set is 50 ft long, equivalent to approximately 15.24 m.
What material is the refrigerant tubing made from?
The source product information lists 99.9% pure copper tubing.
What standards are referenced for the copper tubing?
ASTM B280 and C12200 are referenced in the source product information.
What insulation material is used?
The featured product configuration uses Black Rubber insulation.
What is the listed temperature range of the Black Rubber insulation?
The source product information lists a temperature range of -40°C to 120°C for the Black Rubber insulation.
What insulation thicknesses are available?
Listed Black Rubber insulation thicknesses include 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.
What size HVAC system can use a 3/8 x 5/8 line set?
The DABUND product family lists 3/8 in. x 5/8 in. as a general reference for some 3.0–4.0 ton or 36,000–48,000 BTU systems. Final line-set sizing must follow the equipment manufacturer's required refrigerant-line dimensions.
Can every mini split use this 50 ft line set?
No. Confirm the required liquid-line and suction-line sizes, maximum permitted refrigerant piping length, elevation difference and connection requirements for the specific HVAC system.
Does a 50 ft line set require additional refrigerant?
Additional refrigerant may be required depending on the HVAC equipment and total installed line length. Follow the equipment manufacturer's refrigerant charging instructions.
Is this line set listed for R410A and R32?
The source product information lists R410A and R32 among the compatible refrigerants. Final suitability should be confirmed against the HVAC equipment manufacturer's specifications.
Can this line set be used outdoors?
The source product information describes the factory-applied insulation as UV-resistant for compatible outdoor refrigerant-line installations.
Is additional field insulation required?
Factory-applied insulation reduces the need for additional field wrapping, although local codes and specific project conditions may require additional protection.
What is the pressure rating?
The source page lists a broad 2100–7000 PSI reference range. Because actual pressure ratings depend on tube diameter, wall thickness and test method, confirm the working pressure and burst pressure for the exact 3/8 x 5/8 configuration before ordering.
What other mini split line set sizes are available?
Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
What production lengths are available?
The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths.
Can DABUND provide free samples?
Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer paying the express freight. View Sample Information
What payment terms are available?
Available payment methods include T/T, L/C at sight and credit card.
What delivery terms are available?
Available delivery terms include EXW, FOB, CFR and CIF.
Does DABUND support OEM and ODM?
Yes. OEM and ODM services, including logo customization, are available for suitable orders.
What is the typical delivery time?
The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.