75 ft 3/8 in. x 7/8 in. Insulated Copper Pipe
The DABUND 75 ft 3/8 in. x 7/8 in. Insulated Copper Pipe is a pre-insulated refrigerant line set for compatible high-capacity split air conditioners, ductless HVAC systems, heat pumps, VRF/VRV systems and commercial air-conditioning projects.
The paired line set combines a 3/8 in. liquid line with a 7/8 in. suction line and provides a fixed 75 ft length, approximately 22.86 m, for HVAC installations requiring a longer refrigerant piping route.
The source product information specifies 99.9% pure copper and references ASTM B280 and C12200 for the copper tubing. White PE is the main insulation configuration shown on this page, while Black Rubber insulation is also available.
Quick Answer: This 75 ft 3/8 x 7/8 insulated copper line set is generally referenced for compatible 6–8 ton / 72,000–96,000 BTU HVAC systems. Final compatibility must be confirmed from the equipment manufacturer's required pipe sizes, maximum piping length, elevation limit and refrigerant-charge requirements.
Insulated Copper Pipe Video
75 ft 3/8 x 7/8 Copper Line Set Specifications
| Product Type | Pre-Insulated HVAC Copper Line Set |
| Liquid Line | 3/8 in. / 9.52 mm |
| Suction Line | 7/8 in. / 22.22 mm |
| Length | 75 ft / approximately 22.86 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 according to product specification |
| Featured Insulation | White PE |
| Alternative Insulation | Black Rubber Foam |
| Listed Temperature Range | -40°C to 120°C; confirm for exact insulation configuration |
| General Capacity Reference | 6–8 Ton / 72,000–96,000 BTU |
| Applications | Compatible Split AC / Commercial HVAC / VRF / VRV / Heat Pump / Ductless Systems |
3/8 in. Liquid Line and 7/8 in. Suction Line
This line set combines a 3/8 in. liquid refrigerant line with a 7/8 in. suction return line.
The 3/8 x 7/8 configuration is used in compatible higher-capacity HVAC equipment where the manufacturer specifies these exact refrigerant-line diameters.
Final pipe sizing should always follow the HVAC equipment manufacturer's installation manual rather than relying only on nominal tonnage or BTU capacity.
99.9% Pure Copper Refrigerant Tubing
The source page specifies 99.9% pure copper for the refrigerant tubing and references ASTM B280 and C12200 according to product specification.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC and refrigeration piping applications.
ASTM B280 and C12200
ASTM B280 and C12200 are referenced for the copper tubing. Buyers requiring project-specific compliance documentation should confirm the exact tubing specification supplied with the ordered SKU.
75 ft Length for Extended HVAC Installations
The 75 ft refrigerant line equals approximately 22.86 m and provides routing flexibility where compatible indoor and outdoor HVAC equipment are separated by a greater distance.
A continuous line can reduce unnecessary intermediate joints compared with connecting multiple shorter tubing sections, provided the installed route remains within the HVAC equipment manufacturer's permitted piping limits.
Typical applications may include large residential air-conditioning projects, commercial HVAC systems, VRF/VRV installations and ductless heat-pump systems.
Factory-Applied Insulation
Factory-applied insulation surrounds the copper tubing to reduce unwanted thermal exchange and surface condensation while simplifying field installation.
White PE is the primary insulation configuration shown on this page. Black Rubber foam is also listed as an available insulation option.
Thermal Protection
Insulation helps reduce heat gain or heat loss along the refrigerant line and provides a more consistent thermal barrier around the copper tubing.
Moisture and Condensation Protection
Closed-cell insulation helps reduce moisture penetration and surface condensation around cold refrigerant piping.
UV-Resistant Configurations
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability depends on the exact insulation material, thickness and environmental exposure conditions.
Typical Applications for 3/8 x 7/8 Line Sets
Compatible large split air conditioners
Commercial HVAC systems
VRF and VRV systems requiring this pipe size
Ductless heat-pump systems
Large residential air-conditioning projects
Long-distance refrigerant piping installations
General 72,000–96,000 BTU Capacity Reference
The wider DABUND product family lists the 3/8 in. + 7/8 in. line-set configuration as a general reference for some 6–8 ton HVAC systems.
The corresponding family reference is approximately 72,000–96,000 BTU.
These values are general references only. Final pipe size, permitted piping length and system compatibility must follow the HVAC equipment manufacturer's exact specifications.
Copper Line Set Video

99.9% Pure Copper

White PE Insulated Pipe

Plastic Cap Protection
Three-Layer White PE Insulation Structure
The source page describes a multi-layer PE insulation structure for applicable White PE configurations.


Thermal Insulation Pipe Production

Insulated Pipe Warehouse

Inner Layer Insulated Pipe
Outer Protective Layer
The source describes an embossed PE film outer layer with UV-resistant and wear-resistant characteristics.
Middle IXPE Foam Layer
IXPE foam is referenced as the middle layer for thermal insulation, cushioning and reduced water penetration.
Inner Closed-Cell Layer
A closed-cell inner structure is referenced for thermal insulation and moisture control around the copper refrigerant tubing.
White PE Copper Line Set

Insulated Copper Pipe Size Options
| Size | Standard Family Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 75 ft / approximately 22.86 m. The wider product-family table lists 20 m and 25 m as nearby standard metric production lengths, so buyers should specify the exact finished 75 ft configuration when ordering.
Line Set Size and HVAC Capacity Reference
| Line Set Size | General Ton / HP Range | General BTU Range | Typical Application |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton / 0.75P–1P | 9,000–12,000 BTU | Small Split AC |
| 1/4 + 1/2 in. | 1.5–2.0 Ton / 1.5P–2P | 12,000–18,000 BTU | Medium Mini Split AC |
| 1/4 + 5/8 in. | 2.0–2.5 Ton / 2P–2.5P | 24,000–30,000 BTU | Split AC / Heat Pump |
| 3/8 + 5/8 in. | 3.0–4.0 Ton / 3P–4P | 36,000–48,000 BTU | Ductless Commercial AC |
| 3/8 + 3/4 in. | 4.5–6.0 Ton / 4.5P–6P | 54,000–72,000 BTU | Large Split AC |
| 3/8 + 7/8 in. | 6.0–8.0 Ton / 6P–8P | 72,000–96,000 BTU | High-Capacity Ductless HVAC |
These capacity values are general product-family references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact specifications.
Benefits of Pre-Insulated Copper Line Sets
Factory-Applied Insulation
Factory insulation reduces additional field wrapping work and provides more consistent coverage around the copper tubing.
Condensation Protection
Closed-cell insulation helps reduce surface condensation and moisture exposure around cold refrigerant lines.
Longer Routing Options
The 75 ft length provides additional routing flexibility for compatible HVAC projects where the indoor and outdoor equipment are separated by a greater distance.
Important Checks for a 75 ft Refrigerant Run
Confirm Exact Refrigerant Pipe Sizes
Verify that the selected HVAC equipment specifically requires a 3/8 in. liquid line and 7/8 in. suction line.
Verify Maximum Permitted Piping Length
A physical 75 ft line set does not mean every HVAC system permits a 75 ft installed refrigerant run. Confirm the manufacturer's maximum piping length before installation.
Check Minimum Permitted Piping Length
Some HVAC systems specify a minimum piping length. Confirm both minimum and maximum limits in the equipment installation manual.
Check Maximum Elevation Difference
If indoor and outdoor equipment are installed at different elevations, verify the manufacturer's maximum permitted vertical separation.
Check Additional Refrigerant Charge
A 75 ft refrigerant run may require additional refrigerant beyond the equipment's factory charge. Follow the manufacturer's charging instructions for the actual installed piping length.
Check Equivalent Piping Length
Bends, fittings and elevation changes may increase equivalent piping length. Follow the equipment manufacturer's engineering limits rather than relying only on physical tube length.
Provide Proper Pipe Support
Use suitable HVAC supports, clips or brackets along the route to reduce sagging, vibration and mechanical stress on the copper tubing and insulation.
Installation Guidelines
Plan the Complete Routing Path
Measure and plan the refrigerant route before uncoiling, cutting or modifying the copper tubing.
Avoid Sharp Bends and Kinks
Use suitable HVAC tube-bending methods and appropriate bend radii to reduce the risk of kinking, flattening or restricting refrigerant flow.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation around supports, bends and wall penetrations.
Keep Copper Ends Protected
Keep open copper ends capped or sealed during storage and installation to reduce dust, moisture and contamination entering the refrigerant circuit.
Pressure Test and Evacuate Before Startup
Refrigerant piping should be leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.
OEM and Custom Copper Line Set Options
Custom lengths including 15 m, 20 m, 25 m, 30 m, 50 m and 75 ft
Custom copper tube size combinations
Custom insulation thickness
White PE or Black Rubber insulation
Logo printing and pipe markings
Branded and private-label packaging
Bulk supply for distributors and contractors
OEM and ODM configurations
DABUND Insulated Copper Pipe Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC components for distributors, contractors, wholesalers and OEM customers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations can meet ASTM E84, UL94, ASTM D1056 and ASTM G21 requirements according to product specification.
White PE is the primary configuration shown on this page, so buyers requiring certification for White PE should confirm the exact insulation material, thickness and matching test report rather than assuming the listed Polypropylene / Black Rubber documentation applies automatically.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review insulated copper pipes, mini split line sets and related HVAC products.

Frequently Asked Questions
What is a 3/8 x 7/8 x 75 ft insulated copper pipe used for?
It is used as refrigerant piping between compatible indoor and outdoor HVAC equipment requiring a 3/8 in. liquid line and 7/8 in. suction line.
How long is this copper line set?
This SKU is 75 ft long, approximately 22.86 m.
What size HVAC system can use a 3/8 x 7/8 line set?
The wider DABUND product family lists 3/8 x 7/8 as a general reference for some 6–8 ton or 72,000–96,000 BTU systems. Final tubing size must follow the HVAC equipment manufacturer's exact specification.
What copper material is used?
The source product information specifies 99.9% pure copper and references ASTM B280 and C12200 according to product specification.
What insulation options are available?
White PE and Black Rubber foam options are listed. White PE is the primary configuration shown in the product imagery and family table.
What insulation thicknesses are available?
The wider White PE family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
What is the listed working temperature range?
The source technical table lists approximately -40°C to 120°C. Confirm the applicable range for the exact insulation configuration ordered.
Does this exact SKU have a specified pressure rating?
The current source page does not provide a numeric pressure rating for this exact 75 ft SKU. Buyers should confirm copper wall thickness, allowable working pressure and equipment design requirements before specifying the product for a project.
Can this line set be used with R410A or R32?
R410A and R32 applications are referenced in the source FAQ. Final compatibility depends on the copper tube dimensions, wall thickness, allowable pressure and HVAC equipment requirements.
Is 75 ft suitable for every HVAC installation?
No. Confirm the HVAC equipment manufacturer's minimum and maximum permitted piping lengths, elevation limits and refrigerant-charge requirements before installation.
Does a 75 ft refrigerant run require additional refrigerant?
Additional refrigerant may be required depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions for the actual installed piping length.
Why is equivalent piping length important?
Bends, fittings and vertical elevation can increase equivalent piping length beyond the physical 75 ft tube length. Check the equipment manufacturer's engineering limits for the complete installation route.
Can this insulated copper pipe be used outdoors?
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation material and environmental exposure conditions.
Can DABUND customize the copper line set?
Yes. The source page lists custom lengths, copper pipe size combinations, insulation thickness, White PE or Black Rubber insulation, logo printing, pipe marking and branded packaging.
Who typically buys this product?
The product is intended for HVAC contractors, split AC installers, VRF/VRV system suppliers, distributors, importers, wholesalers, OEM brands and commercial HVAC project buyers.
Is professional HVAC installation recommended?
Yes. Refrigerant piping should be installed, leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.