Home Copper Pipe Insulated Copper Pipe 3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
3/8 in × 5/8 in × 82 Ft Insulated Copper Pipe – Pre-Insulated HVAC Refrigerant Line
1. 3/8" x 5/8" is the out dimension in inch. 9.52mm - 15.88mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

Insulated Copper Pipe

Application

HVAC
Inquire
Add to Basket

82 ft 3/8" x 5/8" Insulated Copper Pipe for HVAC Refrigerant Lines

The DABUND 82 ft 3/8" x 5/8" insulated copper pipe is a long-length, pre-insulated HVAC refrigerant piping solution for compatible split air conditioners, ductless systems, heat pumps, and refrigeration applications. It combines a 3/8" (9.52 mm) liquid line and a 5/8" (15.88 mm) suction line in an approximately 82 ft (25 m) continuous coil.

Factory-applied insulation helps reduce unwanted heat transfer, control condensation, and protect the copper tubing while reducing field insulation work. The extended 82 ft length provides additional routing flexibility for installations where indoor and outdoor HVAC equipment are located farther apart.

Manufactured from 99.9% pure copper, the tubing can be supplied according to ASTM B280 requirements using C12200 copper according to the ordered specification. DABUND also supports custom lengths, insulation thicknesses, printed markings, and private-label packaging for HVAC distributors, wholesalers, importers, contractors, and OEM customers.

Product: Pre-Insulated HVAC Copper Refrigerant Line

Pipe Size: 3/8" + 5/8" / 9.52 mm + 15.88 mm OD

Length: 82 ft / approximately 25 m

Copper: 99.9% pure copper

Copper Specification: ASTM B280 / C12200 according to ordered specification

Insulation: White PE / polypropylene / black rubber options

Available Insulation Thickness: 8 / 9 / 10 / 13 / 19 / 25.4 mm depending on configuration

Applications: Split AC, mini split, heat pump, ductless HVAC and compatible refrigeration systems

What Is an 82 ft 3/8" x 5/8" HVAC Refrigerant Line?

A refrigerant line set consists of two copper tubes that connect the indoor and outdoor components of a compatible HVAC system. The two tubes use different diameters because liquid refrigerant and refrigerant vapor have different flow characteristics.

3/8" Liquid Line

The smaller tube has an outside diameter of 3/8" or approximately 9.52 mm. In compatible HVAC equipment, this tube is commonly used as the liquid refrigerant line.

5/8" Suction Line

The larger tube has an outside diameter of 5/8" or approximately 15.88 mm. It is commonly used as the suction or vapor line when specified by the air conditioner or heat pump manufacturer.

82 ft Continuous Coil

The approximately 82 ft (25 m) coil provides additional routing distance for projects involving multi-story buildings, rooftop outdoor units, long horizontal runs, commercial spaces, and other installations where shorter coils are insufficient.

82 ft 3/8" x 5/8" Copper Pipe Technical Specifications

FeatureDetail
ProductPre-Insulated HVAC Copper Refrigerant Line
Total Length82 ft / approximately 25 m
Liquid Line Diameter3/8" / approximately 9.52 mm OD
Suction Line Diameter5/8" / approximately 15.88 mm OD
Material99.9% Pure Copper
Copper SpecificationASTM B280 / C12200 according to ordered specification
InsulationFactory-Applied White PE / Polypropylene / Black Rubber Options
Insulation Thickness8 / 9 / 10 / 13 / 19 / 25.4 mm depending on configuration
Working TemperatureApproximately -40°C to 120°C depending on insulation material
ApplicationsHVAC / Mini Split / Ductless AC / Heat Pumps / Compatible Refrigeration Systems
Refrigerant ApplicationsR410A, R32 and other systems when tubing specifications match equipment requirements
OEM OptionsLength, Tube Size, Insulation, Printing and Packaging

Why Choose an 82 ft Pre-Insulated HVAC Copper Line?

Longer Routing Distance

An 82 ft continuous coil provides more flexibility where the indoor evaporator and outdoor condenser or heat pump are separated by a substantial distance.

Fewer Intermediate Connections

When system design permits, a continuous long copper coil can reduce the need for intermediate refrigerant piping joints, simplifying long routing paths and reducing potential connection points.

Suitable for Multi-Story and Rooftop HVAC Projects

Long coils are useful for installations involving rooftop condensers, equipment rooms, multi-story buildings, long wall routes, and projects where outdoor equipment cannot be positioned directly beside the indoor unit.

Important: The availability of an 82 ft coil does not mean every HVAC system permits an 82 ft installed refrigerant run. Always check the equipment manufacturer's maximum piping length and elevation limits.

99.9% Pure Copper for HVAC Refrigerant Piping

Copper remains widely used for HVAC and refrigeration piping because it combines thermal conductivity, corrosion resistance, workability, pressure performance, and long service life.

ASTM B280 Copper Tubing

DABUND copper tubing can be supplied according to ASTM B280 requirements for seamless copper tube used in air conditioning and refrigeration applications.

C12200 Copper

C12200 copper can be supplied according to the ordered product specification, providing the formability, corrosion resistance, and thermal properties required for professional HVAC refrigerant piping.

Pressure Performance

The actual pressure rating of HVAC copper tubing depends on outside diameter, wall thickness, temper, operating temperature, joining method, and product specification. Buyers should select tubing according to the design pressure and requirements of the exact HVAC system.

Factory-Applied Insulation for Thermal and Condensation Control

Factory-applied insulation creates a continuous thermal barrier around the copper tubing before shipment. Correct insulation helps reduce unwanted heat transfer, control surface condensation, protect the tubing, and reduce field insulation work.

Reduced Heat Transfer

Proper insulation helps limit heat gain or heat loss between refrigerant piping and ambient air, supporting stable HVAC operating conditions.

Condensation Control

Closed-cell insulation helps reduce contact between cold refrigerant tubing and warm, humid air, limiting surface condensation and reducing the risk of moisture affecting nearby building materials.

UV and Weather Resistance

Selected insulation configurations provide UV and environmental resistance for HVAC applications. For long-term outdoor exposure, an additional line-set cover, conduit, or other mechanical protection may be appropriate depending on project conditions.

99.9% pure copper pipe for 3/8 x 5/8 HVAC refrigerant line

99.9% Pure Copper

White PE insulated HVAC copper refrigerant pipe

White PE Insulated Pipe

Plastic cap protecting pre-insulated HVAC copper pipe ends

Protected Copper Tube Ends

Multi-Layer White PE Insulation Structure

DABUND white PE insulation can use a multi-layer structure designed to provide thermal protection, moisture resistance, and physical protection around HVAC copper tubing.

  • Outer Layer: protective PE surface designed for environmental and wear resistance

  • Middle Layer: foam insulation designed to reduce heat transfer

  • Inner Layer: closed-cell structure designed to reduce moisture penetration and improve thermal insulation

Multi-layer white PE insulation for pre-insulated HVAC copper pipe

DABUND thermal insulation pipe production equipment

Thermal Insulation Pipe Production

DABUND pre-insulated HVAC copper pipe warehouse

Insulated Pipe Warehouse

Closed-cell inner layer of pre-insulated HVAC copper pipe

Inner Insulation Layer

White PE and Black Rubber Insulation Options

White PE Insulation

Available white PE insulation thicknesses include approximately 8 mm, 9 mm, 10 mm, 13 mm, 19 mm, and 25.4 mm, supporting different climate conditions and project specifications.

Black Rubber Insulation

Black rubber insulation is also available for HVAC projects requiring a flexible closed-cell insulation material. Available thicknesses depend on the selected configuration.

Insulation Test Standards

Depending on the selected insulation material and specification, DABUND test documentation can reference standards including ASTM E84, UL 94, ASTM D1056, and ASTM G21. Buyers requiring specific compliance documentation should request the test report applicable to the exact product configuration being ordered.

Is 3/8" x 5/8" the Correct HVAC Line Size?

A 3/8" liquid line and 5/8" suction line are used on certain medium-to-larger-capacity split air conditioners and heat pump systems. However, refrigerant pipe diameter should never be selected solely from BTU capacity, horsepower, or tonnage.

Different HVAC manufacturers can specify different pipe sizes for equipment with similar nominal capacities. Always confirm the required liquid-line and suction-line diameters from the exact equipment installation manual.

Check These Specifications Before Ordering

  • Required liquid-line diameter

  • Required suction-line diameter

  • Copper tube wall thickness

  • Refrigerant type

  • Maximum permitted piping length

  • Maximum vertical elevation difference

  • Required insulation thickness

  • Additional refrigerant charge requirement

R410A and R32 HVAC Applications

DABUND copper tubing can be supplied for HVAC systems using refrigerants such as R410A, R32, and other refrigerants when the tube diameter, wall thickness, pressure rating, cleanliness, joining method, and equipment specifications are correctly matched.

Refrigerant compatibility should not be determined by copper pipe diameter alone. Always follow the HVAC manufacturer's technical requirements and applicable installation codes.

Applications of 82 ft Pre-Insulated Copper Pipe

  • Split air conditioning systems

  • Ductless mini split systems

  • Heat pump refrigerant piping

  • Residential HVAC installations

  • Light commercial HVAC projects

  • Multi-story buildings

  • Rooftop outdoor-unit installations

  • Long horizontal refrigerant piping runs

  • Retrofit and replacement HVAC piping

Installation Considerations for an 82 ft Refrigerant Line

Confirm Maximum Refrigerant Piping Length

Before using a long refrigerant line, confirm the maximum piping length permitted by the equipment manufacturer. Some HVAC systems may permit an 82 ft run while others may have a substantially shorter limit.

Check Maximum Elevation Difference

For multi-story installations, confirm the permitted vertical elevation difference between the indoor and outdoor units. Maximum elevation and maximum total piping length can be separate specifications.

Check Additional Refrigerant Charge Requirements

Many HVAC systems include a factory refrigerant charge for a specified standard line length. Longer installations may require additional refrigerant according to the manufacturer's charge-per-foot or charge-per-meter instructions.

Avoid Sharp Bends and Kinks

Use appropriate HVAC copper tube-bending methods and maintain a suitable bend radius. Kinked or excessively flattened tubing can restrict refrigerant flow and should not be installed.

Support Long Refrigerant Runs

Use suitable HVAC clamps, supports, brackets, or line-set channels along long runs to reduce sagging and vibration while protecting the insulation from unnecessary mechanical stress.

Protect Insulation at Wall Penetrations

Use appropriate sleeves, conduit, or protective covers where the copper tubing passes through walls or other structural openings. Avoid tearing, crushing, or excessively compressing the insulation.

Keep Copper Tube Ends Sealed

Keep copper tube ends capped or sealed until final preparation to reduce the risk of dust, moisture, and other contaminants entering the refrigerant circuit.

Leak Test and Evacuate Before Startup

After completing refrigerant connections, follow the equipment manufacturer's procedures for leak testing, pressure testing where applicable, vacuum evacuation, refrigerant adjustment, and system commissioning.

82 ft 3/8 x 5/8 white PE insulated HVAC copper refrigerant line

Available Insulated Copper Pipe Sizes

DABUND manufactures paired insulated copper tubing in multiple diameters, lengths, insulation thicknesses, and flame-resistant configurations for different HVAC equipment and international markets.

SizeLengthWhite PE InsulationFlame Resistant
1/4 + 3/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/4 + 1/215m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/4 + 5/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 5/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 3/415m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/2 + 3/415m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 7/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1

HVAC Copper Line Size Selection Guide

The table below is a general reference only. Refrigerant piping dimensions vary by equipment manufacturer and model, so final selection must follow the specifications of the exact HVAC equipment.

Line Set SizeGeneral Application Reference
1/4" + 3/8"Commonly found on certain smaller mini split systems
1/4" + 1/2"Commonly found on certain small-to-medium HVAC systems
1/4" + 5/8"Available for larger HVAC systems when specified
3/8" + 5/8"Used on certain medium-to-larger HVAC systems when specifically required by the equipment manufacturer
3/8" + 3/4"Larger split HVAC applications when specified
3/8" + 7/8"Larger-capacity HVAC applications when specified

Important: Never select an HVAC copper line solely from BTU, tonnage, or horsepower. Always use the liquid-line and suction-line diameters specified by the equipment manufacturer.

OEM Pre-Insulated Copper Pipe Manufacturer and Supplier

DABUND supplies insulated copper pipe and refrigerant line sets for HVAC distributors, wholesalers, importers, contractors, project suppliers, and private-label HVAC brands.

Custom Copper Pipe Sizes

Available copper tube diameters include 1/4", 3/8", 1/2", 5/8", 3/4", 7/8", 1", and 1-1/8", supporting multiple liquid-line and suction-line combinations.

Custom Coil Lengths

Standard long-coil options include 15 m, 20 m, 25 m, 30 m, and 50 m. Additional lengths can be discussed according to OEM order quantity and project requirements.

Custom Insulation

Buyers can select insulation materials and thicknesses according to climate, condensation-control requirements, project conditions, customer specifications, and target markets.

OEM Printing and Private Label Packaging

DABUND supports custom company names, pipe sizes, length markings, logos, labels, cartons, and private-label packaging for wholesale and distribution customers.

Why Choose DABUND for Pre-Insulated HVAC Copper Pipe?

HVAC Manufacturing Experience Since 2008

DABUND has manufactured HVAC products since 2008, including insulated copper pipe, mini split line sets, refrigeration copper tubing, aluminum pipe, and related HVAC components.

In-House Insulation Production

In-house insulation production supports greater control over insulation thickness, appearance, printed markings, OEM customization, and production scheduling.

B2B Wholesale and Export Supply

DABUND supports distributors, importers, contractors, project buyers, and HVAC brands with bulk production, customized specifications, private-label programs, and international supply.

DABUND HVAC Factory

DABUND manufactures insulated copper pipe, mini split line sets, refrigeration copper tubing, aluminum pipe, and related HVAC parts for international customers.

DABUND pre-insulated copper pipe and HVAC refrigerant line factory

SGS Testing and HVAC Insulation Standards

Copper tubing can be supplied according to ASTM B280 and C12200 specifications. Depending on the selected insulation material and product configuration, test documentation can reference ASTM E84, UL 94, ASTM D1056, and ASTM G21.

Buyers requiring compliance documents should request the technical specification and test report applicable to the exact insulated copper pipe configuration being ordered.

SGS testing documentation for DABUND insulated HVAC copper pipe

DABUND HVAC Exhibitions

DABUND participates in international HVAC exhibitions where distributors, contractors, importers, and professional buyers can inspect insulated copper pipe, refrigerant line sets, insulation materials, and other HVAC products.

DABUND HVAC trade show for insulated copper pipe and refrigerant line sets

FAQ About 82 ft 3/8" x 5/8" Insulated Copper Pipe

What does 3/8" x 5/8" mean on an HVAC copper line?

It refers to the outside diameters of the paired copper tubes. The 3/8" tube measures approximately 9.52 mm OD and the 5/8" tube approximately 15.88 mm OD.

How long is 82 ft in meters?

82 ft is approximately 25 meters.

What HVAC systems use a 3/8" x 5/8" refrigerant line?

This pipe combination is used on certain medium-to-larger split air conditioners and heat pump systems. However, pipe size varies by manufacturer and model, so always verify the required dimensions from the equipment installation manual.

Can I use the full 82 ft coil on any HVAC system?

No. HVAC equipment has specified maximum refrigerant piping lengths and elevation limits. Confirm both requirements before planning an 82 ft installation.

Does an 82 ft refrigerant line require additional refrigerant?

It may. Many HVAC systems contain a factory refrigerant charge for a specified standard piping length. Longer runs may require additional refrigerant according to the manufacturer's charge-per-foot or charge-per-meter specification.

Can the 82 ft copper pipe be cut to a shorter length?

Yes. A qualified HVAC technician can cut the copper tubing to the required length. Any newly prepared flare, braze, or other connection must follow the equipment manufacturer's procedures and applicable HVAC requirements.

Is this insulated copper pipe compatible with R410A and R32?

It can be supplied for compatible R410A, R32, and other HVAC applications when the tubing diameter, wall thickness, pressure rating, cleanliness, joining method, and equipment requirements are correctly matched.

Why is the copper refrigerant pipe pre-insulated?

Factory insulation helps reduce unwanted heat transfer, limit condensation on cold refrigerant tubing, protect the copper pipe, and reduce field insulation work.

Is this insulated copper pipe suitable for outdoor use?

Selected insulation configurations provide UV and weather resistance for outdoor HVAC installations. Additional line-set covers or conduit may still be recommended where piping experiences prolonged sunlight, weather exposure, or risk of physical damage.

Do I need additional insulation on site?

Factory-applied insulation reduces the need for field wrapping along the main coil. However, joints, repaired sections, fittings, or locations requiring a higher insulation thickness may need additional insulation according to the installation specification.

Can DABUND customize the copper line?

Yes. DABUND supports OEM and ODM services including custom copper sizes, coil lengths, insulation materials, insulation thicknesses, company-name printing, meter markings, labels, cartons, and private-label packaging.

Is DABUND a manufacturer or trading company?

DABUND is a manufacturer of insulated copper pipe, mini split line sets, HVAC refrigerant tubing, aluminum pipe, and related HVAC components.

Can I get a sample before placing a bulk order?

Yes. DABUND can provide up to 3 pieces of free samples for evaluation. Buyers normally cover the express shipping cost.

Can DABUND print my company logo?

Yes. DABUND accepts OEM and ODM orders and can customize company names, logos, pipe dimensions, length markings, labels, cartons, and private-label packaging.

What payment terms are available?

Common payment methods can include T/T, L/C at sight, credit card, and other agreed payment methods according to order details.

What delivery terms does DABUND support?

Available international trade terms can include EXW, FOB, CFR, CIF, and other agreed Incoterms depending on customer logistics requirements.

What is the typical delivery time?

Typical production and delivery preparation is approximately 15–20 days depending on order quantity, customization requirements, and current production scheduling. Urgent orders can be discussed before confirmation.

Related Products

1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC&R products needs, on-time and on-budget.