1/4 in. x 3/8 in. Copper Line Set for Mini Split AC
DABUND 1/4 in. x 3/8 in. Copper Line Set provides paired refrigerant tubing for compatible mini split air conditioners, heat pumps, ductless HVAC systems and residential cooling applications.
The line set combines a 1/4 in. liquid line with a 3/8 in. suction line and is available in multiple production lengths for distributors, HVAC contractors and project buyers.
The source product information specifies 99.9% pure copper with ASTM B280 / C12200 referenced for the refrigerant tubing, together with factory-applied insulation for HVAC installation.
Quick Answer: The 1/4 x 3/8 copper line set combines a 6.35 mm liquid line and 9.52 mm suction line for compatible mini split and heat-pump systems. Available production lengths include 15 m, 20 m, 25 m, 30 m and 50 m.
Copper Line Set Video
1/4 x 3/8 Copper Line Set Specifications
| Product Type | Pre-Insulated Copper Refrigerant Line Set |
| Line Set Size | 1/4 in. + 3/8 in. |
| Liquid Line | 1/4 in. / 6.35 mm |
| Suction Line | 3/8 in. / 9.52 mm |
| Available Lengths | 15 m / 20 m / 25 m / 30 m / 50 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 |
| Featured Insulation | White PE insulation shown in product images and family table |
| Other Source-Listed Insulation | Polypropylene / PE foam configurations are also referenced |
| Listed Temperature Range | -40°C to 120°C; confirm applicability to the exact insulation configuration |
| Source-Listed Pressure Range | 2100–7000 PSI; applicable rating depends on tube dimensions, wall thickness and temperature |
| Listed Refrigerants | R410A / R32 are referenced; final compatibility must follow equipment requirements |
| Applications | Compatible Mini Split AC / Heat Pump / Ductless HVAC Systems |
What Is a 1/4 x 3/8 Copper Line Set?
A 1/4 x 3/8 copper line set is a paired refrigerant piping assembly used between compatible indoor and outdoor HVAC equipment.
The smaller 1/4 in. tube typically functions as the liquid refrigerant line, while the larger 3/8 in. tube serves as the suction return line in compatible system designs.
Both tube diameters must match the HVAC equipment manufacturer's specified piping requirements.
99.9% Pure Copper with ASTM B280 / C12200
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200 for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible refrigeration and air-conditioning piping applications.
Suitable HVAC tube-bending tools and appropriate bend radii should be used to reduce the risk of kinking, flattening or restricting refrigerant flow.
Pressure Capability for R410A and R32 Applications
The source page lists a pressure range of 2100–7000 PSI and references R410A and R32 refrigerant applications.
Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and the exact tubing configuration. Confirm the applicable technical specification before using the line set with a specific HVAC system.
Factory-Applied Insulation
Factory-applied insulation reduces additional field insulation work and helps limit thermal exchange and surface condensation around cold refrigerant tubing.
The product images and wider family table on this page prominently show White PE insulation. Other technical sections reference Polypropylene / PE foam configurations, so buyers should confirm the exact insulation material for the ordered product.
White PE Insulation
White PE is the insulation configuration prominently shown in the product images and product-family table on this page.
Closed-Cell Insulation Structure
The source technical information describes a closed-cell PE foam structure intended to provide thermal insulation and moisture protection.
Listed Temperature Range
The source page lists an insulation working temperature range of approximately -40°C to 120°C. Confirm this range for the exact insulation configuration ordered.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Protective Plastic Cap
White PE Embossed Insulation

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
Compatible Mini Split and HVAC Applications
Compatible ductless mini split air conditioners
Heat-pump systems
Residential HVAC installations
Ductless cooling systems
Small-capacity HVAC equipment requiring this pipe size
Final compatibility must be confirmed from the HVAC equipment manufacturer's required liquid-line diameter, suction-line diameter, refrigerant and permitted piping length.
General 9,000–12,000 BTU Capacity Reference
The wider DABUND product family lists the 1/4 in. + 3/8 in. line-set size as a general reference for some 0.75–1.0 ton mini split systems.
The same product-family information references approximately 9,000–12,000 BTU for this tubing combination.
These capacity values are general references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact specifications.
How to Choose the Correct Copper Line Set
Confirm the Liquid and Suction Line Sizes
Confirm that the equipment specifically requires a 1/4 in. liquid line and 3/8 in. suction line before ordering.
Select the Required Length
Available production lengths on this page include 15 m, 20 m, 25 m, 30 m and 50 m. Select a length based on the actual installation route and project requirements.
Verify Maximum Permitted Piping Length
The physical length of a copper coil does not determine the maximum permitted piping length of the HVAC equipment. Always verify the equipment manufacturer's piping limit.
Check Maximum Elevation Difference
For installations with vertical separation between indoor and outdoor equipment, check the maximum permitted elevation difference.
Check Additional Refrigerant Requirements
Longer refrigerant runs may require additional refrigerant beyond the equipment's factory charge. Follow the HVAC manufacturer's charging instructions for the actual installed length.
Installation Guidelines
Plan the Refrigerant Piping Route
Measure the full route before uncoiling, cutting or modifying the copper tubing.
Avoid Sharp Bends and Kinks
Use appropriate HVAC tube-bending methods and suitable bend radii to reduce the risk of tube deformation or restricted refrigerant flow.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and wall penetrations.
Keep Copper Ends Sealed
Keep open copper tube ends capped or sealed during storage and installation to reduce moisture and contamination entering the refrigerant circuit.
Pressure Test and Evacuate Before Startup
Follow the HVAC equipment manufacturer's pressure-testing, evacuation, refrigerant charging and commissioning procedures before system startup.
OEM and Customization Services
Custom production lengths from approximately 1 m to 50 m
Custom insulation thickness
Custom insulation color
Logo printing on insulation
Bulk packaging for distributors
OEM and ODM configurations
Custom configurations are intended for HVAC distributors, wholesalers, contractors and private-label buyers.
White PE Copper Line Set

Available Copper Line Set Sizes
| Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
General Line Set Size and Capacity Reference
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
These values are general product-family references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact requirements.
DABUND Copper Line Set Manufacturing
DABUND has produced HVAC components since 2008 and supplies insulated copper pipe, mini split line sets and related HVAC products to international distributors and professional buyers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations reference ASTM E84, UL94, ASTM D1056 and ASTM G21.
Because the featured product images and family table on this page show White PE insulation, buyers requiring compliance documentation should confirm the exact insulation material, insulation thickness and corresponding test report for the ordered configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review copper line sets, insulated copper tubing and related HVAC products.

Frequently Asked Questions
What is a 1/4 x 3/8 copper line set used for?
It is used as refrigerant piping between compatible indoor and outdoor HVAC equipment requiring a 1/4 in. liquid line and 3/8 in. suction line.
What size mini split uses a 1/4 x 3/8 line set?
The wider DABUND product family lists 1/4 x 3/8 as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU mini split systems. Final sizing must follow the equipment manufacturer's exact requirements.
What lengths are available?
The source product-family table lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths. OEM custom lengths are also referenced elsewhere on the page.
What copper material is used?
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200.
What insulation is shown on this product?
The product images and wider family table prominently show White PE insulation. The technical specification also references Polypropylene / PE foam, so buyers should confirm the exact insulation configuration when ordering.
What insulation thicknesses are available?
The wider White PE product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
What is the listed temperature range?
The source page lists approximately -40°C to 120°C. Confirm the applicable range for the exact insulation configuration ordered.
Is the copper line set compatible with R410A and R32?
R410A and R32 are referenced in the source product information. Final compatibility must be confirmed against the equipment manufacturer's refrigerant, pipe-size and operating-pressure requirements.
What is the pressure rating?
The source page lists a pressure range of 2100–7000 PSI. Actual allowable pressure depends on tube diameter, wall thickness, operating temperature and exact tubing configuration.
Can this copper line set be used outdoors?
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation material and environmental exposure conditions.
What is the advantage of pre-insulated copper tubing?
Factory-applied insulation reduces additional field insulation work, helps limit thermal exchange and reduces surface condensation around cold refrigerant piping.
How do I choose the correct line set length?
Measure the actual installation route and confirm the HVAC equipment manufacturer's maximum piping length, maximum elevation difference and refrigerant charging requirements before selecting the coil length.
Can DABUND customize the copper line set?
Yes. The source page lists custom lengths, insulation thickness and color, logo printing and bulk packaging for distributor and OEM orders.
Is professional HVAC installation recommended?
Yes. Refrigerant piping should be installed, leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.