Home Copper Pipe Pre Insulated Copper Tubing 75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
75 ft 1/2 x 3/4 Pre-Insulated Copper Line Set
1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.25mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

Pre Insulated Copper Tubing

Application

HVAC
Inquire
Add to Basket

75 ft 1/2 in. x 3/4 in. Pre-Insulated Copper Line Set

DABUND 75 ft 1/2 in. x 3/4 in. Pre-Insulated Copper Line Set provides a continuous refrigerant piping solution for compatible mini split air conditioners, ductless heat pumps, split-system HVAC equipment and other installations requiring an extended line run.

The paired refrigerant tubing combines a 1/2 in. liquid line with a 3/4 in. suction line and provides a continuous 75 ft length, approximately 22.86 m.

Manufactured from 99.9% pure copper, the tubing is supplied with factory-applied Black Rubber insulation to help reduce thermal exchange, control surface condensation and simplify compatible HVAC installation.

Quick Answer: This 75 ft 1/2 x 3/4 line set combines a 1/2 in. liquid line and 3/4 in. suction line with Black Rubber insulation for compatible mini split, heat-pump and split-system HVAC installations.

75 ft Pre-Insulated Copper Line Set Video

75 ft 1/2 x 3/4 Copper Line Set Specifications

FeatureSpecification
Product TypePre-Insulated Copper HVAC Refrigerant Line Set
Line Set Size1/2 in. x 3/4 in.
Liquid Line1/2 in. / approximately 12.70 mm
Suction Line3/4 in. / approximately 19.05 mm
Length75 ft / approximately 22.86 m
Material99.9% Pure Copper
InsulationFactory-Applied Thermal Insulation
Featured InsulationBlack Rubber
Listed Insulation Temperature Range-40°C to 120°C
ApplicationsCompatible Mini Split, Ductless AC and Heat-Pump Systems
Listed RefrigerantsR410A, R32 and Similar Compatible HVAC Refrigerants
InstallationPre-Insulated and Ready for Compatible HVAC Connection

1/2 in. Liquid Line and 3/4 in. Suction Line

The 1/2 in. copper tube serves as the liquid refrigerant line, while the 3/4 in. copper tube serves as the suction return line in compatible HVAC refrigerant circuits.

Both tube sizes should be verified against the HVAC equipment manufacturer's specified refrigerant piping dimensions before ordering.

Refrigerant line diameter should not be selected only by nominal BTU or tonnage because required tubing dimensions can vary between HVAC equipment models.

Extended 75 ft Refrigerant Line

The continuous 75 ft line set provides additional routing flexibility where indoor and outdoor HVAC equipment are separated by a moderate to long distance.

It can support compatible multi-story buildings, attic or rooftop installations, larger residential projects and light commercial HVAC layouts where shorter line sets do not provide sufficient reach.

A continuous 75 ft coil can also reduce the need for intermediate refrigerant-line couplings compared with joining several shorter tubing sections.

99.9% Pure Copper Refrigerant Tubing

The line set is manufactured from 99.9% pure copper for compatible HVAC refrigerant piping applications.

Copper provides thermal conductivity, corrosion resistance and flexibility for routing refrigerant piping between compatible indoor and outdoor HVAC equipment.

Factory-Applied Black Rubber Insulation

The featured product configuration uses Black Rubber insulation around the copper refrigerant tubing.

Factory-applied insulation helps reduce unwanted heat gain and heat loss while helping control surface condensation on cold refrigerant tubing.

The source product information lists the Black Rubber insulation for a temperature range of -40°C to 120°C and describes it as providing both thermal insulation and moisture protection.

Copper Line Set and Insulation Video

99.9 percent pure copper HVAC refrigerant tubing

99.9% Pure Copper

black rubber insulated copper HVAC refrigerant pipe

Black Rubber Insulated Pipe

protective plastic cap for insulated copper HVAC line set

Protective Plastic Cap

Black Rubber Pipe Insulation

Black Rubber insulation combines thermal protection with moisture resistance around the copper refrigerant tubing.

Its insulation structure helps reduce condensation and limits moisture movement around cold refrigerant lines.

The listed temperature range for the featured Black Rubber insulation is -40°C to 120°C.

black rubber insulation for HVAC copper refrigerant tubing

Compatible HVAC Applications

  • Compatible mini split air conditioners

  • Ductless heat-pump systems

  • Split-system HVAC equipment

  • Multi-story residential HVAC installations

  • Attic or rooftop HVAC installations

  • Light commercial HVAC projects

Refrigerant Compatibility

The source product information lists R410A and R32 among the commonly used refrigerants for compatible HVAC systems.

Final refrigerant compatibility, required tubing dimensions, allowable pressure and connection requirements should be verified against the HVAC equipment manufacturer's technical documentation.

Benefits of the 75 ft Pre-Insulated Line Set

Extended Installation Reach

The 75 ft continuous coil provides additional routing flexibility for compatible installations where indoor and outdoor units are positioned farther apart.

Reduced Intermediate Connections

A continuous line can reduce the need for intermediate couplings compared with joining multiple shorter tubing sections.

Condensation Control

Factory insulation helps reduce condensation on cold refrigerant tubing and limits moisture exposure near walls, ceilings and structural penetrations.

Thermal Protection

Black Rubber insulation helps reduce unwanted thermal exchange between the refrigerant tubing and surrounding environment during HVAC operation.

Reduced Field Insulation Work

Factory-applied insulation reduces additional field wrapping and provides consistent insulation coverage along the refrigerant tubing.

Important Considerations for a 75 ft Refrigerant Line

Verify Maximum Permitted Line Length

Confirm that the HVAC equipment manufacturer permits at least 75 ft of total refrigerant piping before selecting this product.

Check Maximum Elevation Difference

For multi-story, attic or rooftop installations, verify the maximum permitted vertical separation between indoor and outdoor HVAC equipment.

Check Additional Refrigerant Requirements

A 75 ft refrigerant run may require additional refrigerant depending on the HVAC equipment, factory charge and total installed piping length. Follow the equipment manufacturer's charging instructions.

Confirm the Exact Tube Sizes

Confirm that the HVAC equipment specifically requires a 1/2 in. liquid line and 3/4 in. suction line before ordering.

Support the Refrigerant Piping

Use suitable HVAC-rated clips, straps or support brackets along the line route to reduce sagging, vibration and mechanical stress on the tubing and insulation.

Installation Guidelines

Plan the Complete Refrigerant Line Route

Measure the entire route between indoor and outdoor equipment before installation to confirm that 75 ft is suitable for the intended piping path.

Avoid Sharp Bends and Kinks

Use suitable bending methods and bend radii to reduce the risk of kinking the copper tubing or restricting refrigerant flow.

Protect Insulation at Wall Penetrations

Use sleeves or protective grommets where the insulated line set passes through walls or structural openings to reduce abrasion and insulation damage.

Maintain Insulation Integrity

Avoid cutting, crushing or excessively compressing the insulation because damaged insulation can reduce thermal and condensation-control performance.

Follow the HVAC Equipment Manufacturer's Instructions

Refrigerant piping, connection preparation, evacuation, charging and system commissioning should follow the HVAC equipment manufacturer's installation requirements.

75 ft Black Rubber Insulated Copper Line Set

The featured Black Rubber configuration combines high-purity copper refrigerant tubing with factory-applied insulation for compatible extended HVAC installations.

75 ft 1/2 x 3/4 black rubber insulated copper HVAC refrigerant line set

Available Pre-Insulated Copper Tubing Sizes

Line Set SizeAvailable LengthsBlack Rubber InsulationListed Flame-Resistance Options
1/4 + 3/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 1/2 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 7/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

Capacity Note: The source product family provides general tonnage and BTU references for several line-set combinations, but it does not provide a corresponding tonnage or BTU reference for the 1/2 x 3/4 configuration. Final equipment compatibility must therefore be confirmed from the HVAC manufacturer's specified liquid-line and suction-line dimensions.

Why Choose the DABUND 75 ft 1/2 x 3/4 Line Set?

Designed for Extended Refrigerant Runs

The 75 ft continuous coil provides installation flexibility where compatible indoor and outdoor equipment are separated by a longer distance.

High-Purity Copper Construction

The product uses 99.9% pure copper tubing for compatible HVAC refrigerant piping applications.

Black Rubber Insulation

The featured Black Rubber insulation helps provide thermal protection and condensation control along the refrigerant line.

DABUND Pre-Insulated Copper Tubing Factory

DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation products for distributors and project customers.

DABUND factory manufacturing pre-insulated copper HVAC line sets

Insulation Test Documentation

The source certificate section references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber insulation configurations.

Buyers requiring project-specific compliance documentation should confirm the selected Black Rubber insulation thickness and corresponding test reports before ordering.

DABUND Black Rubber insulation test documentation

International HVAC Exhibitions

DABUND participates in international HVAC exhibitions where distributors and professional buyers can review insulated copper line sets and related HVAC installation products.

DABUND pre-insulated copper HVAC line set at international trade show

Frequently Asked Questions

What does 1/2 in. x 3/4 in. mean?

It refers to the outside diameters of the refrigerant tubing: 1/2 in. for the liquid line and 3/4 in. for the suction return line.

How long is this pre-insulated copper line set?

The line set is 75 ft long, equivalent to approximately 22.86 m.

What material is the refrigerant tubing made from?

The source product information lists 99.9% pure copper tubing.

Is the copper tubing pre-insulated?

Yes. The copper tubing is supplied with factory-applied thermal insulation.

What insulation material is shown?

The featured product configuration uses Black Rubber insulation.

What is the listed temperature range of the Black Rubber insulation?

The source product information lists a temperature range of -40°C to 120°C.

What insulation thicknesses are available?

The wider product family lists Black Rubber insulation thicknesses of 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.

What size HVAC system can use a 1/2 x 3/4 line set?

The source product family does not provide a specific tonnage or BTU mapping for the 1/2 x 3/4 combination. Confirm compatibility using the exact refrigerant-line dimensions specified by the HVAC equipment manufacturer.

Can every HVAC system use a 75 ft line set?

No. Confirm the required pipe sizes, maximum permitted refrigerant piping length, allowable elevation difference and charging requirements for the specific HVAC equipment.

Does a 75 ft line set require additional refrigerant?

Additional refrigerant may be required depending on the HVAC equipment and total installed piping length. Follow the equipment manufacturer's charging instructions.

Is this line set compatible with R410A and R32?

R410A and R32 are listed among the compatible refrigerants. Final suitability should be verified against the specific HVAC equipment manufacturer's specifications.

Can this line set be used outdoors?

The source product information describes applicable Black Rubber insulation configurations as UV-resistant for compatible outdoor refrigerant-line installations. Confirm the selected configuration and project exposure requirements before installation.

Is additional field insulation required?

Factory-applied insulation reduces additional field wrapping, although local codes, project specifications and installation conditions may require extra protection.

What other line set sizes are available?

Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.

What production lengths are available?

The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths.

Is DABUND a manufacturer?

Yes. The source product information identifies DABUND as the manufacturer.

Can DABUND provide free samples?

Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer paying the express freight.    View Sample Information

What payment terms are available?

The listed payment options include T/T, L/C at sight and credit card.

What delivery terms are available?

Listed delivery terms include EXW, FOB, CFR and CIF.

Does DABUND support OEM and ODM?

Yes. OEM and ODM services, including logo customization, are available for suitable orders.

What is the typical delivery time?

The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.

Related Products

Please select a data source

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.