1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

Pre Insulated Copper Tubing

Application

HVAC
Inquire
Add to Basket

1/2 in. x 3/4 in. x 82 ft Pre-Insulated Copper Line Set

DABUND 1/2 in. x 3/4 in. x 82 ft pre-insulated copper line set is designed for compatible HVAC and refrigeration installations, including ductless mini split, heat pump and air-conditioning systems.

The line set combines 1/2 in. and 3/4 in. copper tubing with black rubber insulation to simplify field installation and provide thermal and moisture protection around the refrigerant piping.

The copper tubing is made from 99.9% pure copper and meets ASTM B280 and C12200 requirements. The 1/2 in. and 3/4 in. outside diameters correspond to 12.7 mm and 19.05 mm.

Quick Answer: This 82 ft pre-insulated copper line set uses 1/2 in. and 3/4 in. copper tubing with black rubber insulation and is designed for professional HVACR piping installations.

Product Specifications

Product TypePre-Insulated Copper Line Set
Copper Tube Size1/2 in. x 3/4 in.
Metric Outside Diameter12.7 mm x 19.05 mm
Length82 ft
Copper99.9% Pure Copper
Copper StandardASTM B280 / C12200 DHP
InsulationBlack Rubber Insulation
Insulation Temperature Range-40°C to 120°C
ApplicationsHVAC, refrigeration, ductless mini split, heat pump and air-conditioning systems
CustomizationCompany name, tube size and length markings available

Pre-Insulated Copper Line Set Video

1/2 x 3/4 pre-insulated HVAC copper line set

Key Features of 1/2 x 3/4 Pre-Insulated Copper Tubing

  • 1/2 in. and 3/4 in. outside diameters correspond to 12.7 mm and 19.05 mm.

  • 99.9% pure copper tubing manufactured to ASTM B280 and C12200 requirements.

  • Designed for compatible ductless mini split, heat pump, air-conditioning and refrigeration installations.

  • Black rubber insulation helps provide thermal insulation and moisture protection.

  • Insulation temperature range is listed from -40°C to 120°C.

  • Custom printing can include company name, tube size and length markings.

  • Additional copper tube sizes and line-set lengths are available for different HVAC installations.

ASTM B280 C12200 Copper Tubing

The refrigerant tubing is manufactured from C12200 DHP copper and is designed for HVACR piping applications requiring clean, reliable copper tube.

ASTM B280 copper tubing is widely used for air-conditioning and refrigeration installations. Correct line-set sizing must always follow the equipment manufacturer's installation specifications.

ASTM B280 pre-insulated copper tubing line set

Black Rubber Pipe Insulation

The black rubber insulation provides a closed insulating layer around the copper refrigerant tubing and is designed to reduce heat transfer and moisture condensation.

The listed working temperature range is -40°C to 120°C, supporting use across a wide range of compatible HVAC and refrigeration installations.

The insulation also helps protect the copper tubing from direct environmental exposure and provides a cleaner installation appearance.

black rubber insulation for pre-insulated copper line set

Thermal and Moisture Protection

Thermal Insulation

The dense insulation structure helps reduce heat transfer between the refrigerant tubing and the surrounding environment.

Moisture Condensation Control

The insulation acts as both a thermal insulation layer and a moisture-resistant layer, helping reduce condensation around the refrigerant line.

Outdoor Protection

The insulation is designed to provide additional protection for copper piping used in compatible HVAC installations.

Flame-Resistance Options

DABUND lists insulation options with ASTM E84, UL94, ASTM D1056 and ASTM G21 performance references. For projects requiring specific certification, request the applicable test documentation for the ordered insulation construction.

1/2 x 3/4 x 82 ft insulated copper line set

Available Pre-Insulated Copper Line Set Sizes

Copper Tube SizeAvailable LengthsBlack Rubber InsulationListed Flame-Resistance Options
1/4 + 3/8 in.15m / 20m / 25m / 30m / 50m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 1/2 in.15m / 20m / 25m / 30m / 50m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 5/8 in.15m / 20m / 25m / 30m / 50m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 5/8 in.15m / 20m / 25m / 30m / 50m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 3/4 in.15m / 20m / 25m / 30m / 50m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2 + 3/4 in.15m / 20m / 25m / 30m / 50m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 7/8 in.15m / 20m / 25m / 30m / 50m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

General Mini Split Line Set Size Reference

The following size-to-capacity combinations are general references for the DABUND line set family. Always select refrigerant tubing according to the air-conditioner or heat-pump manufacturer's installation manual.

Line Set SizeTypical Ton ReferenceTypical BTU Reference
1/4 + 3/8 in.0.75–1.0 Ton9,000 / 12,000 BTU
1/4 + 1/2 in.1.5–2.0 Ton12,000 / 18,000 BTU
1/4 + 5/8 in.2.0–2.5 Ton24,000 / 30,000 BTU
3/8 + 5/8 in.3.0–4.0 Ton36,000 / 48,000 BTU
3/8 + 3/4 in.4.5–6.0 Ton54,000 / 72,000 BTU
3/8 + 7/8 in.6.0–8.0 Ton72,000–96,000 BTU

The 1/2 + 3/4 in. configuration should be matched to the specific HVAC equipment manufacturer's required liquid-line and suction-line dimensions rather than selected by capacity alone.

pre-insulated copper line set sizes for HVAC and mini split systems

HVACR Applications

  • Ductless mini split air conditioners

  • Heat-pump systems

  • VRF installations

  • Central air-conditioning systems

  • Unitary HVAC systems

  • Compatible refrigeration applications

OEM Copper Line Set Printing

DABUND produces insulation in-house and supports customized identification for suitable orders.

Printing can include company name, tube size, length information and other agreed product markings for distributors, HVAC brands and private-label customers.

DABUND Pre-Insulated Copper Line Set Factory

DABUND has manufactured pre-insulated copper tubing and HVAC installation products since 2008.

Product lines include insulated copper pipe, mini split line sets, aluminum pipe and other HVAC installation components for international distribution and project supply.

DABUND factory producing and packaging pre-insulated copper line sets

Quality and Test Documentation

DABUND supplies pre-insulated copper line sets with insulation constructions available for different HVAC requirements.

ASTM E84, UL94, ASTM D1056 and ASTM G21 references are listed for applicable insulation constructions. Buyers requiring certification for a specific project should confirm the exact insulation material, thickness and applicable test documentation before ordering.

certificate for DABUND insulated copper line set products

International HVAC Exhibitions

DABUND participates in international exhibitions where distributors, contractors and HVAC buyers can review mini split line sets and related installation products.

DABUND mini split line set international exhibition

Frequently Asked Questions

What size copper tubing is included in this line set?

This product uses 1/2 in. and 3/4 in. outside-diameter copper tubing, corresponding to 12.7 mm and 19.05 mm.

How long is this pre-insulated copper line set?

This product configuration is 82 ft long.

What copper standard does the tubing meet?

The copper tubing is listed as ASTM B280 and C12200 DHP copper.

What insulation is used on this line set?

This product is supplied with black rubber insulation.

What is the operating temperature range of the insulation?

The listed insulation temperature range is -40°C to 120°C.

Can this copper line set be used for a mini split system?

Yes, provided the HVAC equipment requires 1/2 in. and 3/4 in. refrigerant-line sizes. Always follow the equipment manufacturer's specified line dimensions.

Can it be used with heat pumps and other HVAC systems?

The line-set family is designed for compatible ductless mini split, heat-pump, VRF, central air-conditioning and other HVACR installations.

What other copper line set sizes are available?

Available combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.

What lengths can DABUND manufacture?

Listed production lengths include 15 m, 20 m, 25 m, 30 m and 50 m.

Can DABUND print our company name on the insulation?

Yes. Custom printing can include company name, tube size, length and other agreed identification.

Is DABUND a manufacturer?

Yes. DABUND has manufactured pre-insulated copper tubing and HVAC installation products since 2008.

Can I request a sample?

Yes. Up to 3 sample pieces can be provided free of charge, with express shipping cost paid by the buyer.    View Sample Information

What payment terms are available?

Available payment methods include T/T, L/C at sight and credit card.

What delivery terms are available?

Available delivery terms include EXW, FOB, CFR and CIF.

What is the typical delivery time?

Typical delivery time is approximately 15–20 days. Actual lead time depends on order quantity, insulation configuration, customization and production schedule.

Related Products

Black PVC line set cover for mini split AC and heat pumps. Conceals and protects refrigerant pipes, drain hoses and cables in indoor or outdoor HVAC installs.
Line covers keep your pipes and cords well organized while providing protection and extending the lifespan of your AC unit by reducing maintenance. The refrigerant pipe can be painted to match your exterior wall color and to provide a seamless appearance on your building.
Line covers keep your pipes and cords well organized while providing protection and extending the lifespan of your AC unit by reducing maintenance. The refrigerant pipe can be painted to match your exterior wall color and to provide a seamless appearance on your building.
Line covers keep your pipes and cords well organized while providing protection and extending the lifespan of your AC unit by reducing maintenance. The refrigerant pipe can be painted to match your exterior wall color and to provide a seamless appearance on your building.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.