Home AC Accessories Manifold Gauge Set R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
R12 R22 R134a R404a Manifold Gauge Set
  • DABUND

  • Brass

Application

R134a R404a R22 R12
Inquire
Add to Basket

R12 R22 R134A R404A Manifold Gauge Set

DABUND R12 R22 R134A R404A Manifold Gauge Set is an analog HVACR service tool for monitoring low-side and high-side refrigerant pressure during compatible air-conditioning and refrigeration service procedures.

The product is identified for R12, R22, R134A and R404A applications. It can support system inspection, troubleshooting, evacuation and refrigerant charging when the manifold gauge set, hoses and connections are correctly matched to the equipment being serviced.

According to the current product information, the manifold uses double O-ring piston valves. Manifold configurations equipped with a sight glass also allow visual observation of liquid during applicable service procedures.

Quick Answer: This is a multi-refrigerant analog manifold gauge set for compatible R12, R22, R134A and R404A HVACR systems, with dual pressure gauges and filling hoses shown in the current product information.

Ordering Notice: The current product information does not specify the exact low-side pressure range, high-side pressure range, manifold port dimensions, service hose connection sizes, hose length or hose pressure rating. Confirm these specifications for the exact model before ordering.

Manifold Gauge Set Specifications

Product TypeMulti-Refrigerant Manifold Gauge Set
Refrigerants ListedR12 / R22 / R134A / R404A
Gauge TypeAnalog
Pressure MonitoringLow-side and high-side refrigerant pressure
Valve DesignDouble O-ring piston valves
Sight GlassAvailable on manifold configurations equipped with a sight glass
Service HosesFilling hoses shown in current product information
Typical ApplicationsCompatible air-conditioning and refrigeration service

Multi-Refrigerant HVACR Manifold Gauge

This manifold gauge set is identified for servicing compatible R12, R22, R134A and R404A air-conditioning and refrigeration systems.

A multi-refrigerant manifold configuration can support HVACR distributors, maintenance companies and technicians working with different refrigerant systems.

Before use, confirm that the gauge scales, pressure ranges, hoses and service connections of the exact manifold model are suitable for the refrigerant and equipment being serviced.

R12 R22 R134A R404A manifold gauge set with dual analog pressure gauges

Testing Manifold Double Meter Valve

Filling hose for R12 R22 R134A R404A manifold gauge set

Filling Hose

Low-Side and High-Side Pressure Monitoring

The dual analog gauges allow technicians to monitor refrigerant pressure on both the low-pressure and high-pressure sides of a compatible HVACR system.

Pressure readings can support system inspection and troubleshooting when interpreted together with the refrigerant type, equipment specifications and actual operating conditions.

The current product information does not provide the exact pressure range of either gauge. Confirm the required pressure ranges for the intended refrigerant before ordering.

R12 Refrigerant Service

R12 is one of the refrigerants identified for this manifold gauge set. Before servicing a compatible R12 system, confirm that the selected gauge scale, pressure range, hoses and connections match the equipment.

R22 Refrigerant Service

R22 is also listed for this product. The exact manifold configuration should be checked for suitable gauge ranges, service hoses and equipment connections before use.

R134A Refrigerant Service

The manifold gauge set is identified for compatible R134A applications. Confirm the exact gauge scales, pressure ranges and hose connections for the R134A equipment being serviced.

R404A Refrigerant Service

R404A is included among the refrigerants listed for this product. Verify the required pressure range, hose specifications and connection configuration for the actual refrigeration system before servicing.

Air Conditioner Charging and Testing

The manifold gauge set can support compatible air-conditioning and refrigeration testing, evacuation and charging procedures.

Pressure readings provide service information while the manifold and filling hoses provide connections for applicable HVACR procedures.

Always confirm refrigerant compatibility, pressure range and connection specifications before connecting the manifold gauge set to a system.

Double O-Ring Piston Valves

The current product information identifies the manifold with double O-ring piston valves.

These valves form part of the manifold flow-control arrangement used during compatible HVACR service procedures.

Sight Glass Option

Manifold configurations equipped with a sight glass allow technicians to visually observe liquid during applicable service procedures.

The current product information does not confirm that every configuration includes a sight glass. Buyers requiring this feature should confirm it for the exact model before ordering.

Gauge Zero Calibration

Before connecting the manifold gauge set to a pressurized system, check whether the analog gauges return to 0 psi when unpressurized.

According to the current product instructions, if a gauge does not read 0 psi, remove the gauge face and adjust the calibration screw until the pointer returns to 0 psi.

Gauge condition and zero calibration should be checked before pressure-dependent service work.

HVACR Service Applications

The R12 R22 R134A R404A manifold gauge set is intended for professional service of compatible air-conditioning and refrigeration systems.

  • Low-side refrigerant pressure monitoring

  • High-side refrigerant pressure monitoring

  • Air-conditioning system servicing

  • Refrigeration system servicing

  • System inspection and troubleshooting support

  • Evacuation procedures

  • Refrigerant charging procedures

  • HVACR maintenance and repair work

How to Select a Multi-Refrigerant Manifold Gauge

Confirm the Refrigerant

Identify the refrigerant used by the equipment and confirm that the exact gauge configuration is suitable for that refrigerant.

Confirm the Low-Side Pressure Range

Check that the low-side gauge range is appropriate for the refrigerant and equipment being serviced.

Confirm the High-Side Pressure Range

Verify that the high-side gauge range is suitable for the intended service conditions.

Confirm Gauge Scales and Units

Confirm the refrigerant scales, pressure units and temperature markings required for the target market and service application.

Confirm Manifold and Hose Connections

Verify the manifold port dimensions, service hose fittings and compatibility with the equipment service ports.

Confirm Hose Specifications

Confirm the required hose quantity, hose length, connection dimensions and pressure specification before ordering.

Confirm Whether a Sight Glass Is Required

If a manifold sight glass is required for the intended servicing procedure, verify that the selected configuration includes this feature.

Important Safety Notice

Refrigerant manifold gauge sets are professional service tools for pressurized HVACR systems and should be operated by trained personnel following the applicable equipment and refrigerant service procedures.

Caution: Never open the high-side valve on the manifold gauge set while the air-conditioning system is operating.

Check valve positions, gauge condition, refrigerant compatibility and all hose connections before connecting the manifold to the system.

Information to Confirm Before Ordering

HVAC distributors, wholesalers, contractors and refrigeration service companies should confirm the following information before ordering:

  • Required refrigerant: R12, R22, R134A, R404A or multiple refrigerants

  • Low-side gauge pressure range

  • High-side gauge pressure range

  • Gauge refrigerant scales

  • Pressure and temperature units

  • Gauge diameter

  • Manifold port size

  • Service hose connection size

  • Hose quantity

  • Hose length

  • Hose working pressure

  • Whether a sight glass is required

  • Required package contents

  • Order quantity

  • Packaging requirements

  • OEM or private-label requirements

These technical parameters are not fully specified in the current product information and should be confirmed for the exact manifold configuration before placing an order.

DABUND HVACR Manifold Gauge Sets

DABUND supplies refrigerant manifold gauge sets and related HVAC installation and service products for distributors, wholesalers, contractors and professional HVACR service companies.

DABUND has supplied HVAC-related products since 2008.

OEM and ODM requirements can be discussed according to refrigerant configuration, gauge requirements, hose configuration, packaging and commercial purchasing requirements.

Frequently Asked Questions

Which refrigerants are listed for this manifold gauge set?

The current product information identifies R12, R22, R134A and R404A.

Is this an analog or digital manifold gauge set?

The current product information and images show an analog manifold gauge configuration.

Does the manifold measure both low-side and high-side pressure?

Yes. The manifold uses dual analog gauges for monitoring low-side and high-side refrigerant pressure.

Does the manifold use double O-ring piston valves?

Yes. The current product information identifies the manifold with double O-ring piston valves.

Does every manifold include a sight glass?

Not necessarily. Manifold configurations equipped with a sight glass allow liquid to be viewed during applicable service procedures. Confirm whether the exact model includes this feature.

Can this manifold gauge set be used for R12?

R12 is identified for this product. Confirm that the exact gauge scales, pressure ranges, hoses and connections are suitable for the system being serviced.

Can this manifold gauge set be used for R22?

R22 is listed for this product. Confirm the exact gauge and hose configuration before servicing an R22 system.

Can this manifold gauge set be used for R134A?

Yes. R134A is identified for this product. Confirm the applicable pressure range and connection requirements for the equipment.

Can this manifold gauge set be used for R404A?

R404A is also listed. Confirm the gauge pressure range, hoses and service connections required by the refrigeration equipment before use.

Can this manifold gauge set be used for refrigerant charging?

Yes. The current product information identifies refrigerant charging as an applicable service procedure when the manifold gauge set is correctly matched to the system.

Can it be used during system evacuation?

The current product information identifies evacuation as an applicable manifold gauge service procedure.

What should I do if the gauge does not read 0 psi?

According to the current product instructions, remove the gauge face and adjust the calibration screw until the pointer returns to 0 psi.

What is the pressure range of the gauges?

The current product information does not specify the exact low-side or high-side gauge pressure ranges. Confirm these specifications for the exact model before ordering.

What connection size does the manifold use?

The current product information does not provide the manifold port or service hose connection dimensions. Confirm the required connection sizes before ordering.

Are filling hoses included?

Filling hoses are shown in the current product information. Confirm the exact quantity, hose length, fittings and package contents for the selected manifold configuration.

Can I open the high-side valve while the AC system is operating?

No. The current product instructions specifically caution against opening the high-side manifold valve while the air-conditioning system is operating.

Can DABUND provide OEM or ODM manifold gauge sets?

Yes. OEM and ODM requirements can be discussed according to refrigerant configuration, gauge requirements, hose configuration, packaging and commercial order requirements.

Can I request a sample?

Sample requests are available according to the current sales policy.    View sample information.

What payment terms are available?

Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.

What delivery terms are available?

Available international trade terms can include EXW, FOB, CFR and CIF.

What is the typical delivery time?

The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on order quantity, product configuration, customization and production schedule.

Related Products

Product name: Anti-vibration rubber pads Composition:natural rubber + carbon clack +anti-aging system. Scope:Home air conditiong Product Features:Hot galvanize screw, rubber material, durable Design, strong rubber Product Advantages: Anti-corrosion, shock absorber noise reduction, easy to install
1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 3/8"+3/4" 25 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts.  2. Both of the two copper pipe end do flaring and nuts.  3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm.  4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m.  5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200.  6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
Hot rolled plate construction,Strong and Durable. Anti-rusting,anti-corrosion and weather resistant,Perfect for long-term outdoor use. Fits most of mini split ductless air conditioner heat pump systems.  

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.