Manifold Gauge Set for R134a, R410A, R404A and R22
The DABUND Manifold Gauge Set for R134a, R410A, R404A and R22 is an HVAC and refrigeration service tool for refrigerant pressure measurement, charging, vacuum evacuation and system troubleshooting.
Also known as an HVAC manifold gauge, AC manifold gauge or refrigeration gauge set, it allows technicians to monitor low-side and high-side refrigerant pressure during air-conditioning and refrigeration service.
This analog manifold gauge set is suitable for service applications involving R134a, R410A, R404A and R22 when the gauge range, hose connections and system requirements match.
Quick Answer: A manifold gauge set connects to the low-side and high-side service ports of compatible HVAC or refrigeration equipment so technicians can monitor system pressure during diagnosis, evacuation and refrigerant service.
Product Images

Testing Manifold Double Meter Valve

Filling Hose
HVAC Manifold Gauge Set for Refrigerant Service
This manifold gauge set is designed for air-conditioner charging, refrigerant pressure testing, vacuum evacuation and troubleshooting during HVAC and refrigeration maintenance.
The analog gauges allow technicians to observe low-side and high-side pressures and compare the readings with the service data specified by the equipment manufacturer.
Pressure readings can support diagnosis of charging conditions, pressure imbalance, refrigerant-flow restrictions and other HVAC or refrigeration system problems.
Key Features
Designed for R134a, R410A, R404A and R22 service applications
Suitable for HVAC, air-conditioning and refrigeration maintenance
Measures low-side refrigerant pressure
Measures high-side refrigerant pressure
Analog mechanical gauge display
Suitable for refrigerant charging work
Suitable for vacuum evacuation procedures
Supports pressure testing and HVAC troubleshooting
Double O-ring piston valve design
Filling hoses included for refrigerant service connections
OEM logo and packaging options available
Bulk supply available for HVAC distributors and wholesalers
Compatible Refrigerants
R134a Refrigerant Service
The manifold gauge set supports compatible R134a refrigeration and air-conditioning service applications.
R410A Refrigerant Service
It can be used for compatible R410A HVAC service applications when the gauge range, hoses and service connections match the equipment requirements.
R404A Refrigerant Service
The gauge set supports compatible R404A refrigeration service and pressure-monitoring applications.
R22 Refrigerant Service
It also supports R22 service applications where use and servicing are permitted and the equipment connection requirements match.
Low-Side and High-Side Pressure Measurement
The manifold gauge set measures both low-side and high-side refrigerant pressure during HVAC and refrigeration service.
Low-Side Gauge
The low-side gauge is used to monitor suction-side pressure during compatible service procedures.
High-Side Gauge
The high-side gauge monitors discharge-side or liquid-side pressure according to the design of the HVAC or refrigeration system being serviced.
Double O-Ring Piston Valve Design
The manifold uses a double O-ring piston valve design to support sealing during refrigerant service work.
The manifold body, pressure gauges and filling hoses form the main service-tool configuration.
Technical Specifications
| Specification | Detail |
| Product Name | Manifold Gauge Set R134a R410A R404A R22 |
| Product Type | HVAC manifold gauge / refrigeration gauge set |
| Compatible Refrigerants | R134a, R410A, R404A, R22 and related service applications |
| Gauge Type | Analog mechanical gauge |
| Measured Pressure | Low-side and high-side refrigerant pressure |
| Valve Design | Double O-ring piston valve |
| Included Parts | Manifold body, pressure gauges and filling hoses |
| Application | Air conditioner charging, refrigerant testing, evacuation and HVAC troubleshooting |
| Customization | OEM logo, packaging and configuration customization available |
Refrigerant Charging
The manifold gauge set can be connected between compatible HVAC equipment and refrigerant service equipment during charging procedures.
Refrigerant charging should follow the equipment manufacturer's specified refrigerant type, charge quantity and service procedure.
Vacuum Evacuation
The center service hose can be connected to a compatible vacuum pump when evacuating an HVAC or refrigeration system before charging.
Evacuation procedures should be performed according to the HVAC equipment manufacturer's service instructions.
HVAC and Refrigeration Applications
Residential air-conditioner service
Mini split AC installation and maintenance
Commercial refrigeration system service
Heat-pump pressure testing
Refrigerant charging procedures
Refrigerant recovery service
Vacuum evacuation before charging
HVAC troubleshooting and system diagnosis
HVAC contractor service kits
Refrigeration technician service kits
Pressure Diagnosis for HVAC Technicians
Comparing low-side and high-side pressure readings with the equipment manufacturer's service data can help technicians evaluate system operating conditions.
Pressure readings may support troubleshooting of refrigerant charging conditions, system restrictions, pressure imbalance and other cooling-system issues.
Gauge Calibration Before Use
Before service work, check whether the gauges read 0 psi when they are not pressurized.
If a gauge does not return to 0 psi, adjust the calibration screw according to the gauge design before taking system pressure readings.
Important Safety Notes
Do Not Open the High-Side Valve While the AC Is Running
Never open the high-side valve on the manifold gauge set while the air-conditioning system is operating. Incorrect operation can result in unsafe pressure release or equipment damage.
Confirm Refrigerant and Service Connections
Verify the refrigerant type and service-port connection before connecting the gauge set.
Refrigerant Handling by Trained Personnel
Refrigerant recovery, evacuation, charging and leak-testing procedures should be performed by trained personnel according to equipment instructions and applicable local requirements.
How to Use a Manifold Gauge Set
Confirm the refrigerant type and service-port size before connection.
Check that the gauges are calibrated to 0 psi before use.
Connect the low-side hose to the suction service port.
Connect the high-side hose to the discharge or liquid service port where applicable.
Connect the center hose to a vacuum pump, refrigerant cylinder or recovery machine according to the service task.
Read the pressure values and compare them with the equipment manufacturer's service data.
After service, close the manifold valves, disconnect the hoses safely and reinstall the service-port caps.
Manifold Gauge Set for HVAC Contractors and Distributors
DABUND supplies manifold gauge sets, filling hoses, HVAC tools and air-conditioner installation accessories for contractors, refrigeration technicians, distributors, wholesalers and importers.
OEM options include logo printing, private-label packaging, carton design and product configuration for qualifying B2B orders.
DABUND HVAC Tool Supply
DABUND has produced HVAC tools, installation accessories, insulated copper pipe, mini split line sets and related air-conditioner parts since 2008.
Frequently Asked Questions
What is a manifold gauge set used for?
A manifold gauge set is used to measure refrigerant pressure and support charging, vacuum evacuation and troubleshooting during HVAC and refrigeration service.
Which refrigerants does this manifold gauge set support?
It supports compatible service applications involving R134a, R410A, R404A and R22.
Does the gauge set measure both low-side and high-side pressure?
Yes. The analog gauges measure low-side and high-side refrigerant pressure during compatible HVAC and refrigeration service procedures.
Can this manifold gauge set be used for refrigerant charging?
Yes. It can be used during compatible refrigerant charging procedures when the refrigerant, gauge range, hoses and connections match the system requirements.
Can the manifold gauge set be used with a vacuum pump?
Yes. The center service hose can be connected to a compatible vacuum pump during system evacuation.
Why should the gauges read 0 psi before use?
A zero reading helps verify gauge calibration before service. An incorrect zero position can affect pressure readings.
Can I open the high-side valve while the AC system is operating?
No. Never open the high-side manifold valve while the air-conditioning system is operating.
Can this gauge set be used for refrigeration systems?
Yes, for compatible refrigeration service applications when the refrigerant type, service connections and gauge requirements match the equipment.
What parts are included with the manifold gauge set?
The configuration includes the manifold body, analog pressure gauges and filling hoses.
Can DABUND customize the manifold gauge set?
Yes. DABUND supports OEM logo, private-label packaging, carton design and product configuration customization for qualifying wholesale orders.