82 ft 3/8 in. x 5/8 in. Mini Split Long Line Set
DABUND 82 ft 3/8 in. x 5/8 in. Mini Split Long Line Set provides pre-insulated copper refrigerant piping for compatible ductless mini split air conditioners, heat pumps, HVAC systems and refrigeration applications requiring an extended piping route.
The paired copper tubing combines a 3/8 in. liquid line with a 5/8 in. suction line and provides a continuous 82 ft length, approximately 25 m.
Manufactured from 99.9% pure copper with ASTM B280 / C12200 referenced in the source product information, the line set is supplied with factory-applied White PE / IXPE insulation to help reduce thermal exchange and surface condensation.
Quick Answer: This 82 ft 3/8 x 5/8 mini split long line set combines high-purity copper tubing with White PE / IXPE insulation for compatible extended HVAC and refrigeration installations.
82 ft Mini Split Long Line Set Video
82 ft 3/8 x 5/8 Line Set Specifications
| Product Type | Pre-Insulated Mini Split Refrigerant Line Set |
| Pipe Size | 3/8 in. + 5/8 in. |
| Liquid Line | 3/8 in. / 9.52 mm |
| Suction Line | 5/8 in. / 15.88 mm |
| Length | 82 ft / 25 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 |
| Featured Insulation | White PE / IXPE Foam |
| Insulation Structure | UV-Resistant PE Outer Layer / IXPE Foam / Closed-Cell Inner Layer |
| Listed Temperature Range | -40°C to 120°C; confirm applicability to the ordered insulation configuration |
| Source-Listed Pressure Range | 2100–7000 PSI; applicable rating depends on tube dimensions and wall thickness |
| Listed Refrigerant | R410A is specifically referenced; final compatibility must follow equipment specifications |
| Applications | Compatible Mini Split / Heat Pump / HVAC / Refrigeration Systems |
82 ft Long Line Set for Extended HVAC Installations
The 82 ft / 25 m continuous line set provides additional routing flexibility for compatible installations where indoor and outdoor equipment are positioned farther apart.
Typical layouts may include larger residential properties, multi-story buildings, heat-pump installations, commercial HVAC projects and other applications requiring an extended refrigerant piping route.
A continuous long coil can reduce unnecessary intermediate joints when the complete piping route remains within the HVAC equipment manufacturer's permitted piping limits.
3/8 in. Liquid Line and 5/8 in. Suction Line
This line set combines a 3/8 in. liquid refrigerant line with a 5/8 in. suction return line.
Before ordering, verify that the intended mini split, heat-pump or refrigeration equipment specifically requires these exact pipe diameters.
Nominal system capacity should only be used as a preliminary reference because refrigerant pipe-size requirements can vary between manufacturers and individual HVAC models.
99.9% Pure Copper with ASTM B280 / C12200
The source product information specifies 99.9% pure copper and references ASTM B280 and C12200 for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC and refrigeration piping.
Suitable tube-bending tools and appropriate bend radii should be used to reduce the risk of kinking, flattening or restricting refrigerant flow.
Pressure Capability for R410A Applications
The source page lists a pressure range of 2100–7000 PSI and specifically references R410A refrigerant applications.
Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and the exact product configuration. Confirm the applicable rating before selecting the line set for a specific HVAC system.
White PE / IXPE Pre-Insulated Copper Line Set
The featured configuration uses White PE insulation with an IXPE foam thermal layer and a closed-cell inner structure.
Factory-applied insulation helps reduce thermal exchange, surface condensation and additional field insulation work during installation.
UV-Resistant Embossed PE Outer Layer
The source describes an embossed PE outer layer intended to provide UV and wear resistance around the insulation.
IXPE Foam Middle Layer
The IXPE foam middle layer provides thermal insulation, impact absorption and additional protection around the copper tubing.
Closed-Cell Inner Layer
The closed-cell inner structure helps limit moisture penetration and reduce condensation around cold refrigerant piping.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Protective Plastic Cap
White PE Embossed Insulation

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
82 ft White PE Copper Line Set
The 82 ft 3/8 x 5/8 configuration is intended for professional HVAC contractors, distributors and project buyers requiring a longer continuous copper piping length.

Compatible HVAC Applications
Compatible ductless mini split air conditioners
Heat-pump systems
Residential HVAC installations
Commercial HVAC projects
Central air-conditioning systems requiring this pipe size
Compatible refrigeration systems
Extended refrigerant piping projects
Final compatibility should be confirmed from the equipment manufacturer's required liquid-line size, suction-line size, refrigerant type, maximum piping length and operating requirements.
General 3–4 Ton Capacity Reference
The wider DABUND product family lists the 3/8 in. + 5/8 in. configuration as a general reference for some 3.0–4.0 ton systems.
The same family information references approximately 36,000–48,000 BTU for this tube-size combination.
These values are general references only. Final refrigerant piping size must follow the HVAC equipment manufacturer's exact specification.
Important Checks for an 82 ft Refrigerant Run
Verify Maximum Permitted Piping Length
Confirm that the selected HVAC equipment permits at least the required 82 ft refrigerant piping route.
Confirm the Exact Pipe Sizes
Verify that the equipment specifically requires a 3/8 in. liquid line and 5/8 in. suction line.
Check Maximum Elevation Difference
For multi-story installations, confirm the maximum permitted vertical separation between indoor and outdoor units.
Check Additional Refrigerant Charge
An 82 ft piping run may require additional refrigerant beyond the equipment's factory charge. Follow the manufacturer's charging instructions for the actual installed piping length.
Provide Proper Pipe Support
Use suitable HVAC-rated supports, clips or straps to reduce sagging, vibration and mechanical stress along the extended piping route.
Installation Guidelines
Measure the Complete Route
Measure and plan the complete refrigerant piping route before uncoiling or cutting the copper tubing.
Avoid Sharp Bends and Kinks
Use appropriate tube-bending tools and suitable bend radii to reduce the risk of tube deformation or restricted refrigerant flow.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation, particularly around bends, supports and wall penetrations.
Keep Pipe Ends Protected
Keep open copper tube ends capped or sealed during storage and installation to reduce moisture and contamination entering the refrigerant circuit.
Pressure Test and Evacuate Before Startup
Follow the HVAC equipment manufacturer's pressure-testing, evacuation, refrigerant charging and commissioning procedures before system startup.
Available Mini Split Line Set Sizes
| Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific product is 82 ft / 25 m, which matches the 25 m production length listed in the wider product family.
General Line Set Size and Capacity Reference
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
These capacity ranges are general product-family references only. Final refrigerant line sizing must follow the HVAC equipment manufacturer's exact technical requirements.
DABUND Manufacturing and Supply
DABUND manufactures insulated copper pipe and mini split line sets for distributors, HVAC contractors and project buyers requiring standard or customized refrigerant piping configurations.

Insulation Test Documentation
The source certificate section references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber insulation configurations.
Because the featured configuration on this page uses White PE / IXPE insulation, buyers requiring compliance documentation should confirm the exact insulation material, thickness and corresponding test report for the ordered configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review mini split line sets, insulated copper tubing and related HVAC products.

Frequently Asked Questions
What is an 82 ft 3/8 x 5/8 mini split line set used for?
It is used as refrigerant piping between compatible indoor and outdoor HVAC equipment requiring a 3/8 in. liquid line and 5/8 in. suction line.
How long is this line set?
The product is 82 ft long, equivalent to approximately 25 m.
What size HVAC system can use a 3/8 x 5/8 line set?
The wider DABUND product family lists 3/8 x 5/8 as a general reference for some 3.0–4.0 ton or 36,000–48,000 BTU systems. Final sizing must follow the HVAC equipment manufacturer's exact requirements.
Can every 3–4 ton HVAC system use an 82 ft line set?
No. Capacity alone does not determine compatibility. Confirm the exact liquid-line and suction-line sizes, maximum permitted piping length, maximum elevation difference and refrigerant charging requirements for the specific equipment model.
Does an 82 ft line set require additional refrigerant?
Additional refrigerant may be required depending on the HVAC equipment's factory charge and total installed piping length. Follow the equipment manufacturer's charging instructions.
What copper material is used?
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200.
What insulation is used?
The featured product images and family table show White PE insulation with an IXPE foam middle layer and closed-cell inner structure.
What insulation thicknesses are available?
The wider White PE product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
What is the listed temperature range?
The source product information lists approximately -40°C to 120°C for the insulation description. Confirm that this range applies to the exact configuration ordered.
Is the line set compatible with R410A?
R410A is specifically referenced in the source product information. Final compatibility must be confirmed against the equipment manufacturer's refrigerant, tubing and pressure requirements.
What is the pressure rating?
The source page lists a pressure range of 2100–7000 PSI. Actual allowable pressure depends on tube diameter, wall thickness, operating temperature and exact copper configuration.
Is the insulation suitable for outdoor installation?
The source page describes the PE outer layer as UV resistant. Final outdoor suitability should be confirmed for the exact insulation material and exposure conditions.
Can the 82 ft copper line be shortened?
The copper tubing can be shortened when appropriate HVAC cutting, deburring and connection procedures are used according to the equipment manufacturer's installation instructions.
Is DABUND a manufacturer?
Yes. The source page identifies DABUND as a manufacturer of mini split line sets, insulated copper pipe and related HVAC products.
Can I request free samples?
The source page states that up to three free samples can be supplied for qualified requests, with express freight paid by the buyer. View Sample Information
What payment terms are available?
Listed payment options include T/T, L/C at sight and credit card.
What delivery terms are available?
Listed delivery terms include EXW, FOB, CFR and CIF.
What is the typical delivery time?
The source product information lists approximately 15–20 days, depending on order quantity and production requirements.