82 ft 1/4 in. x 3/8 in. Mini Split Long Line Set
DABUND 82 ft 1/4 in. x 3/8 in. Mini Split Long Line Set provides an extended pre-insulated copper refrigerant piping solution for compatible ductless mini split air conditioners, heat pumps and HVAC installations where the indoor and outdoor units are located farther apart.
The paired refrigerant tubing combines a 1/4 in. liquid line with a 3/8 in. suction line and provides an 82 ft length, approximately 25 m.
Manufactured from 99.9% pure C12200 copper and listed to ASTM B280, the line set is supplied with factory-applied insulation for compatible residential and light commercial HVAC installations.
Quick Answer: This 82 ft 1/4 x 3/8 mini split long line set combines ASTM B280 copper tubing with White PE insulation for compatible extended-run ductless AC and heat-pump installations.
82 ft Mini Split Long Line Set Video
82 ft 1/4 x 3/8 Line Set Specifications
| Product Type | Pre-Insulated Mini Split Refrigerant Line Set |
| Line Set Size | 1/4 in. x 3/8 in. |
| Liquid Line | 1/4 in. / 6.35 mm |
| Suction Line | 3/8 in. / 9.52 mm |
| Length | 82 ft / 25 m |
| Copper Material | 99.9% Pure C12200 Copper |
| Copper Standard | ASTM B280 |
| Factory Insulation | Pre-Insulated Copper Tubing |
| Featured Insulation | White PE |
| Other Listed Insulation Options | Polypropylene or Black Rubber configurations are also referenced in the source product information |
| Listed Working Temperature | -40°C to 120°C; confirm applicability to the ordered insulation configuration |
| Listed Refrigerants | R410A and R32; final compatibility must follow HVAC equipment specifications |
| Applications | Compatible Ductless Mini Split, Heat Pump, Residential HVAC and Light Commercial Systems |
1/4 in. Liquid Line and 3/8 in. Suction Line
The paired copper refrigerant tubing combines a 1/4 in. liquid line with a 3/8 in. suction return line.
Before ordering, confirm that the specific mini split or heat-pump system requires these exact refrigerant-line dimensions.
Refrigerant line size should not be selected only by nominal BTU or tonnage because required liquid-line and suction-line dimensions can vary between HVAC manufacturers and individual equipment models.
82 ft Length for Long-Distance HVAC Installations
The 82 ft continuous line set provides additional routing flexibility when indoor and outdoor HVAC units are located farther apart.
Typical compatible project layouts may include multi-story homes, apartments, small offices, outdoor condensers positioned away from living areas and other installations where a shorter refrigerant line does not provide sufficient reach.
A long continuous coil can also reduce the need for unnecessary intermediate refrigerant-line joints, provided the total installed piping route remains within the HVAC equipment manufacturer's permitted limits.
ASTM B280 C12200 Copper Refrigerant Tubing
The source product information specifies 99.9% pure C12200 copper tubing and references ASTM B280.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible HVAC refrigerant piping applications.
Proper tube-bending methods and suitable bend radii should be used to reduce the risk of kinking, flattening or restricting refrigerant flow during installation.
Factory-Insulated Copper Line Set
The copper refrigerant tubing is supplied with factory-applied insulation to help reduce unwanted thermal exchange and surface condensation.
Factory insulation also reduces additional field wrapping work and provides continuous protection along the refrigerant piping route.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Protective Plastic Cap
White PE Insulated Copper Pipe
The featured product configuration uses White PE insulation around the copper refrigerant tubing.
White PE insulation provides a thermal protective layer around the refrigerant pipe and helps reduce condensation during compatible HVAC operation.

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
Flexible Copper Coil for Complex HVAC Routes
The 82 ft refrigerant line set is supplied in a flexible coil for routing through compatible walls, ceilings and building structures.
A continuous flexible coil can reduce unnecessary joints while allowing installers to route the tubing around structural obstacles using appropriate HVAC bending methods.
White PE Insulation Thickness Options
The wider product family lists multiple White PE insulation thicknesses for different project and climate requirements.
8 mm
9 mm
10 mm
13 mm
19 mm
25.4 mm

Compatible HVAC Applications
Compatible ductless mini split air conditioners
Heat-pump systems
Residential HVAC installations
Apartment and multi-story building installations
Small office air-conditioning systems
Light commercial HVAC projects
Compatible refrigeration equipment requiring this pipe size
Final compatibility must be confirmed from the HVAC equipment manufacturer's required liquid-line size, suction-line size, refrigerant type, maximum piping length and installation requirements.
Refrigerant Compatibility
The source product information specifically lists R410A and R32 for compatible HVAC applications using ASTM B280 copper tubing.
Refrigerant compatibility should not be determined by refrigerant name alone. Confirm tube diameter, wall thickness, allowable working pressure and the HVAC equipment manufacturer's requirements before installation.
Important Considerations for an 82 ft Refrigerant Run
Verify Maximum Permitted Line Length
Confirm that the selected mini split or heat-pump system permits at least the required 82 ft refrigerant piping route before installation.
Confirm the Exact Pipe Sizes
Verify that the selected HVAC equipment specifically requires a 1/4 in. liquid line and 3/8 in. suction line.
Check Maximum Elevation Difference
For multi-story installations, confirm the maximum allowable vertical separation between the indoor and outdoor units.
Check Additional Refrigerant Requirements
An 82 ft refrigerant run may require additional refrigerant depending on the HVAC equipment, factory refrigerant charge and total installed piping length. Follow the equipment manufacturer's charging instructions.
Support the Long Refrigerant Run
Use suitable HVAC-rated clips, straps or supports along the piping route to reduce sagging, vibration and mechanical stress on the copper tubing and insulation.
Installation Guidelines
Measure the Complete Installation Route
Measure the complete refrigerant piping route between the indoor and outdoor equipment before cutting or installing the tubing.
Avoid Sharp Bends and Kinks
Use appropriate tube-bending methods and bend radii to reduce the risk of copper tube deformation or restricted refrigerant flow.
Maintain Continuous Insulation Coverage
Avoid cutting, crushing or leaving unnecessary gaps in the insulation, especially around bends, supports and wall penetrations.
Use Proper Cutting and Flaring Procedures
If the copper tubing is shortened, use appropriate HVAC cutting, deburring, flaring and sealing procedures before making refrigerant connections.
Pressure Test and Evacuate Before Startup
Follow the HVAC equipment manufacturer's approved pressure-testing, evacuation, charging and commissioning procedures before system startup.
Available Mini Split Line Set Sizes
| Line Set Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific product is 82 ft / 25 m, which matches the 25 m length listed in the wider product family.
General Line Set Size and Capacity Reference
The following capacity ranges are general references from the wider DABUND mini split line set family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact piping requirements.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
For the 1/4 x 3/8 configuration, the DABUND product family lists 0.75–1.0 ton and 9,000–12,000 BTU as general references. Actual compatibility must be confirmed using the HVAC equipment manufacturer's required liquid-line and suction-line dimensions.
Why Choose the DABUND 82 ft 1/4 x 3/8 Line Set?
82 ft Extended Refrigerant Run
The 25 m length provides additional routing flexibility for compatible residential, multi-story and light commercial installations.
ASTM B280 C12200 Copper
The source product information specifies 99.9% pure C12200 copper and ASTM B280 for the refrigerant tubing.
White PE Factory Insulation
The featured White PE insulation provides thermal protection and helps reduce condensation around cold refrigerant piping.
Multiple Insulation Thicknesses
The wider product family lists White PE insulation thicknesses from 8 mm to 25.4 mm for different project conditions.
Distributor and Project Supply
Multiple line sizes, insulation options and production lengths are available across the wider DABUND product family for HVAC distributors and project buyers.
DABUND Mini Split Line Set Factory
DABUND manufactures mini split line sets, insulated copper pipe, aluminum pipe and related HVAC components for distributors, contractors and project customers.

Insulation Test Documentation
The source certificate section references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber mini split line set insulation configurations.
Because the featured product configuration on this page uses White PE insulation, buyers requiring project-specific compliance documentation should confirm the exact insulation material, insulation thickness and corresponding test report for the ordered configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where distributors and professional buyers can review mini split line sets, insulated copper tubing and related HVAC products.

Frequently Asked Questions
What is an 82 ft mini split long line set used for?
It connects compatible indoor and outdoor mini split or heat-pump equipment where an extended refrigerant piping route is required.
How long is this mini split line set?
The product is 82 ft long, equivalent to 25 m.
What does 1/4 in. x 3/8 in. mean?
It refers to the outside diameters of the two copper tubes: 1/4 in. for the liquid line and 3/8 in. for the suction line.
What size mini split can use a 1/4 x 3/8 line set?
The DABUND product family lists 1/4 x 3/8 as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU systems. Final pipe sizing must follow the HVAC equipment manufacturer's exact requirements.
What copper material is used?
The source product information specifies 99.9% pure C12200 copper tubing and ASTM B280.
What insulation material is shown on this product?
The featured product images and wider product-family specification table show White PE insulation.
What White PE insulation thicknesses are available?
The wider product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm White PE insulation thicknesses.
Is this line set compatible with R410A and R32?
R410A and R32 are listed in the source product information. Final suitability must be confirmed against the HVAC equipment manufacturer's refrigerant, pressure and tubing requirements.
Can every mini split use an 82 ft refrigerant line?
No. Confirm the equipment manufacturer's maximum permitted piping length, maximum vertical separation, required pipe sizes and refrigerant charging requirements before installation.
Does an 82 ft line set require additional refrigerant?
Additional refrigerant may be required depending on the HVAC equipment, factory charge and total installed piping length. Follow the equipment manufacturer's charging instructions.
Can the 82 ft copper line set be shortened?
Yes. The source product information states that the copper line set can be cut to the required installation length. Proper HVAC cutting, deburring, flaring and sealing procedures should be used after modification.
Can the insulated line set be installed outdoors?
The source product family offers insulated configurations intended for different installation environments. Confirm the exact insulation material, UV performance and outdoor suitability of the ordered configuration before installation.
What other mini split line set sizes are available?
Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
Is DABUND a mini split line set manufacturer?
Yes. DABUND identifies itself as a manufacturer of mini split line sets, HVAC copper tubing, insulated copper pipe and related HVAC components.