Home Copper Pipe Pre-insulated Copper Pipe 82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
82 ft 1/4 x 3/8 Pre-Insulated Copper Line Set
1. 1/4" x 3/8" is the out dimension in inch. 6.35mm - 9.52mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

Pre-insulated Copper Pipe

Application

HVAC
Inquire
Add to Basket

82 ft 1/4 in. x 3/8 in. Pre-Insulated Copper Line Set

DABUND 82 ft 1/4 in. x 3/8 in. Pre-Insulated Copper Line Set provides an extended refrigerant piping solution for compatible mini split air conditioners, ductless heat pumps and split-system HVAC installations.

The paired refrigerant tubing combines a 1/4 in. liquid line with a 3/8 in. suction line and provides an 82 ft length, approximately 25 m.

Manufactured from 99.9% pure seamless copper, the line set is supplied with factory-applied insulation to help reduce thermal exchange, control surface condensation and simplify compatible HVAC installation.

Quick Answer: This 82 ft 1/4 x 3/8 mini split line set combines high-purity copper refrigerant tubing with factory-applied White PE insulation for compatible long-run ductless AC and heat-pump installations.

82 ft Pre-Insulated Copper Line Set Video

82 ft 1/4 x 3/8 Line Set Specifications

Product TypePre-Insulated Copper HVAC Refrigerant Line Set
Line Set Size1/4 in. x 3/8 in.
Liquid Line1/4 in. / approximately 6.35 mm
Suction Line3/8 in. / approximately 9.52 mm
Length82 ft / approximately 25 m
Copper Material99.9% Pure Seamless Copper
InsulationFactory-Applied Closed-Cell Insulation
Featured InsulationWhite PE Configuration Shown
Insulation FeaturesMoisture Resistant, Condensation Resistant and UV-Resistant Outer Jacket
Listed RefrigerantsR410A and R32; final suitability must follow equipment specifications
ApplicationsCompatible Mini Split, Ductless AC, Heat Pump and Light Commercial HVAC Systems

1/4 in. Liquid Line and 3/8 in. Suction Line

The paired refrigerant tubing combines a 1/4 in. liquid line with a 3/8 in. suction return line.

Before ordering, verify that the specific mini split or heat-pump system requires these exact liquid-line and suction-line diameters.

Refrigerant piping should not be selected only by nominal BTU or tonnage because required pipe sizes can vary between HVAC equipment manufacturers and individual models.

82 ft Length for Extended Mini Split Installations

The 82 ft length provides additional routing flexibility where compatible indoor and outdoor HVAC equipment are separated by a longer distance.

It can support compatible residential homes, apartments, offices, multi-zone projects and light commercial installations where shorter refrigerant piping does not provide sufficient reach.

Before using an 82 ft refrigerant run, confirm the HVAC equipment manufacturer's maximum permitted piping length, maximum vertical elevation difference and additional refrigerant charging requirements.

99.9% Pure Seamless Copper Refrigerant Tubing

The source product information specifies 99.9% pure seamless copper construction for the refrigerant tubing.

Copper provides thermal conductivity and flexibility for routing compatible refrigerant piping through walls, ceilings and exterior installation routes.

Proper bending methods should be used to avoid kinking or flattening the tubing during installation.

Factory-Applied White PE Insulation

The featured product configuration uses White PE insulation around the copper refrigerant tubing.

The source product information describes closed-cell insulation with a UV-resistant outer protective jacket and resistance to moisture and condensation.

Factory-applied insulation helps reduce unwanted thermal exchange while reducing additional insulation work during installation.

Copper Line Set and Insulation Video

99.9 percent pure copper mini split refrigerant tubing

99.9% Pure Copper

white PE insulated copper mini split refrigerant pipe

White PE Insulated Pipe

protective plastic cap for pre-insulated copper HVAC line set

Protective Plastic Cap

Product Details

The product-detail image below shows the construction and presentation of the pre-insulated copper refrigerant tubing.

82 ft pre-insulated copper mini split line set product details

White PE Insulated Copper Pipe

White PE insulation provides a protective thermal layer around the copper tubing to help reduce temperature fluctuation and surface condensation during compatible HVAC operation.

white PE embossed insulation for mini split copper refrigerant tubing

Insulation Production and Structure

machines for production of HVAC thermal insulation pipe

Insulation Pipe Production

warehouse for HVAC insulation pipes

Insulation Pipe Warehouse

inner insulation layer for mini split refrigerant tubing

Inner Layer Insulated Pipe

Benefits of the 82 ft Pre-Insulated Copper Line Set

Extended Installation Reach

The 82 ft length provides additional routing flexibility where compatible indoor and outdoor mini split equipment cannot be installed close together.

Reduced Thermal Exchange

Factory-applied insulation helps reduce unwanted heat transfer between the refrigerant tubing and the surrounding environment.

Condensation Control

Closed-cell insulation helps reduce condensation on cold refrigerant tubing and limits moisture exposure around the installation route.

Flexible Copper Routing

The copper tubing can be routed through compatible walls, ceilings and exterior paths when appropriate HVAC bending methods are used.

82 ft 1/4 x 3/8 white PE insulated mini split refrigerant line set

Compatible HVAC Applications

  • Compatible ductless mini split air conditioners

  • Residential split AC systems

  • Ductless heat-pump installations

  • Apartment and office HVAC projects

  • Light commercial air-conditioning systems

  • Replacement refrigerant-line projects

  • Extended indoor-to-outdoor unit piping routes

Final compatibility should be confirmed using the HVAC equipment manufacturer's required liquid-line size, suction-line size, maximum piping length, elevation limits and refrigerant requirements.

Refrigerant Compatibility

The source product information specifically references R410A and R32 for modern HVAC applications.

Final refrigerant suitability should be confirmed against the specific HVAC equipment manufacturer's tubing, pressure, refrigerant and installation requirements.

Important Considerations for an 82 ft Refrigerant Run

Verify Maximum Permitted Line Length

Confirm that the selected mini split or heat-pump system permits at least the required 82 ft refrigerant piping route before installation.

Check Maximum Elevation Difference

If the indoor and outdoor units are installed at different heights, verify the maximum allowable vertical separation specified by the equipment manufacturer.

Check Additional Refrigerant Requirements

An 82 ft refrigerant run may require additional refrigerant depending on the HVAC equipment, factory charge and total installed line length. Follow the equipment manufacturer's charging instructions.

Confirm the Exact Pipe Sizes

Confirm that the selected HVAC system specifically requires a 1/4 in. liquid line and 3/8 in. suction line.

Support the Long Refrigerant Run

Use appropriate HVAC-rated clips, straps or supports along the piping route to reduce sagging, vibration and mechanical stress on the copper tubing and insulation.

Installation Guidelines

Measure Before Cutting

Measure the complete refrigerant piping route before cutting the copper tubing.

Avoid Kinks During Bending

Use suitable bending methods and bend radii to reduce the risk of flattening or kinking the copper tubing.

Maintain Continuous Insulation Coverage

Avoid cutting, crushing or leaving unnecessary gaps in the insulation, particularly at bends, supports and wall penetrations.

Use Proper Flaring and Torque Procedures

If the tubing is shortened or field connections are prepared, use suitable HVAC cutting, deburring and flaring tools and follow the equipment manufacturer's specified connection torque.

Pressure Test Before Startup

Follow the HVAC equipment manufacturer's approved pressure-testing and evacuation procedures before system startup.

Available Pre-Insulated Copper Line Set Sizes

Line Set SizeAvailable LengthsWhite PE InsulationListed Flame-Resistance Options
1/4 + 3/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 1/2 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 7/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

General Line Set Size and Capacity Reference

The following capacity ranges are general references from the wider DABUND pre-insulated copper line set family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact piping requirements.

Line Set SizeGeneral Ton ReferenceGeneral BTU Reference
1/4 + 3/8 in.0.75–1.0 Ton9,000–12,000 BTU
1/4 + 1/2 in.1.5–2.0 Ton12,000–18,000 BTU
1/4 + 5/8 in.2.0–2.5 Ton24,000–30,000 BTU
3/8 + 5/8 in.3.0–4.0 Ton36,000–48,000 BTU
3/8 + 3/4 in.4.5–6.0 Ton54,000–72,000 BTU
3/8 + 7/8 in.6.0–8.0 Ton72,000–96,000 BTU

For the 1/4 x 3/8 configuration, the DABUND product family lists 0.75–1.0 ton and 9,000–12,000 BTU as general references. Final compatibility must be confirmed from the exact liquid-line and suction-line requirements of the HVAC equipment.

Why Choose the DABUND 82 ft 1/4 x 3/8 Line Set?

82 ft Extended Refrigerant Run

The 25 m class length provides routing flexibility for compatible installations requiring greater separation between indoor and outdoor HVAC equipment.

99.9% Pure Seamless Copper

High-purity seamless copper construction provides flexible refrigerant tubing for compatible residential and light commercial HVAC projects.

Closed-Cell Factory Insulation

Factory-applied insulation helps reduce condensation and unwanted thermal exchange while reducing additional insulation work during installation.

Multiple Production Options

The wider DABUND product family offers multiple line-size combinations, production lengths and insulation thicknesses for distributor and project requirements.

DABUND Pre-Insulated Copper Pipe Factory

DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC products for distributors, contractors and project customers.

DABUND factory manufacturing pre-insulated copper mini split line sets

Insulation Test Documentation

The source certificate section references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber insulation configurations.

Because the featured product images on this page show White PE insulation, buyers requiring project-specific compliance documentation should confirm the selected insulation material, thickness and corresponding test report before ordering.

DABUND HVAC line set insulation test documentation

International HVAC Exhibitions

DABUND participates in international HVAC exhibitions where distributors and professional buyers can review insulated copper tubing, mini split line sets and related HVAC products.

DABUND mini split refrigerant line set at international HVAC exhibition

Frequently Asked Questions

What does 1/4 in. x 3/8 in. mean?

It refers to the outside diameters of the two refrigerant tubes: 1/4 in. for the liquid line and 3/8 in. for the suction return line.

How long is this pre-insulated copper line set?

The product is 82 ft long, equivalent to approximately 25 m.

What material is the refrigerant tubing made from?

The source product information specifies 99.9% pure seamless copper.

Is the copper line factory insulated?

Yes. The source product information specifies factory-applied high-density insulation and describes closed-cell foam insulation with moisture- and condensation-resistant properties.

What insulation material is shown?

The featured product images and family specification table show White PE insulation.

What White PE insulation thicknesses are available?

The wider product family lists White PE insulation thicknesses of 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.

What size mini split can use a 1/4 x 3/8 line set?

The DABUND product family lists 1/4 x 3/8 as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU systems. Final pipe sizing must follow the HVAC equipment manufacturer's exact requirements.

Can every mini split use an 82 ft refrigerant line?

No. Confirm the specific equipment's maximum permitted piping length, maximum elevation difference, required tube dimensions and refrigerant charging requirements.

Does an 82 ft line set require additional refrigerant?

Additional refrigerant may be required depending on the HVAC equipment, factory charge and total installed line length. Follow the equipment manufacturer's charging instructions.

Is this line set compatible with R410A and R32?

R410A and R32 are specifically referenced in the source product information. Final compatibility should be confirmed against the equipment manufacturer's pressure, refrigerant and tubing requirements.

Is this line set compatible with every mini split brand?

Universal compatibility should not be assumed. Confirm the required 1/4 in. liquid line, 3/8 in. suction line, allowable piping length and connection requirements for the specific HVAC model.

Can the 82 ft copper tubing be shortened?

Yes. The source product information states that the copper tubing can be cut to custom lengths. Proper HVAC cutting, deburring, flaring and sealing procedures should be used after modification.

Can the line set be installed outdoors?

The source product information describes a UV-resistant outer protective jacket. Final outdoor suitability should be confirmed for the selected insulation configuration and project exposure conditions.

Does this line set require additional insulation?

The tubing is factory pre-insulated. Additional protection may still be required depending on outdoor exposure, wall penetrations, local installation requirements and project specifications.

What other pre-insulated copper line set sizes are available?

Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.

What production lengths are available?

The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths. The 82 ft product corresponds approximately to the 25 m option.

Is DABUND a manufacturer?

Yes. The source product information identifies DABUND as a manufacturer of pre-insulated copper pipe, mini split line sets and related HVAC products.

Can DABUND provide free samples?

Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer responsible for express freight.    View Sample Information

What payment terms are available?

Listed payment options include T/T, L/C at sight and credit card.

What delivery terms are available?

Listed delivery terms include EXW, FOB, CFR and CIF.

Does DABUND support OEM and ODM?

Yes. OEM and ODM services, including logo customization, are available for suitable orders.

What is the typical delivery time?

The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.

Related Products

Please select a data source

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.