75 Ft 1/4" x 3/8" Mini Split Long Line Set
DABUND 75 ft 1/4" x 3/8" Mini Split Long Line Set is a pre-insulated twin copper refrigerant piping solution for compatible ductless mini split air conditioners, heat pumps and split HVAC systems requiring an extended piping run.
The paired copper tubing includes a 1/4" tube and a 3/8" tube, equivalent to approximately 6.35 mm and 9.52 mm outside diameter. The continuous coil length is 75 ft, approximately 22.86 m.
On compatible HVAC equipment, the 1/4" tube commonly functions as the liquid refrigerant line while the 3/8" tube functions as the suction or gas return line. Exact refrigerant pipe dimensions must be verified against the installation specifications for the specific indoor and outdoor equipment combination.
High-purity copper tubing is available to ASTM B280 and C12200 DHP specifications according to the ordered configuration. The displayed product uses White PE insulation designed to provide thermal protection, moisture resistance and protection for the copper tubing.
Quick Answer: This product is a 75 ft / 22.86 m mini split long line set containing 1/4" and 3/8" pre-insulated copper tubing, approximately 6.35 mm and 9.52 mm OD, with White PE insulation for compatible extended-run HVAC installations.
Long-Line Compatibility Notice: A 75 ft refrigerant run is not suitable for every mini split system. Confirm the required pipe sizes, maximum actual piping length, equivalent piping length, vertical separation, refrigerant type and additional refrigerant requirements for the exact HVAC model before installation.
75 Ft 1/4" x 3/8" Long Line Set Specifications
| Brand | DABUND |
| Product Type | Pre-Insulated Mini Split Long Line Set |
| Copper Tube Size | 1/4" + 3/8" |
| Metric Outside Diameter | Approx. 6.35 mm + 9.52 mm |
| Common Line Function | 1/4" liquid line + 3/8" suction/gas line on compatible equipment |
| Length | 75 ft / approx. 22.86 m |
| Copper Material | High-purity copper / C12200 DHP according to specification |
| Copper Tube Standard | ASTM B280 specification available |
| Displayed Insulation | White PE multi-layer insulation |
| Insulation Thickness Options | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm |
| Selected Temperature Range | Approx. -40°C to 120°C depending on insulation specification |
| Applications | Compatible mini split AC, heat pump and split HVAC systems |
| OEM / ODM | Length, insulation, printing, branding and packaging customization |
Key Features of the 75 Ft Mini Split Long Line Set
1/4" Liquid Line and 3/8" Suction Line
On compatible mini split and heat pump systems, the smaller 1/4" copper tube commonly serves as the liquid refrigerant line while the larger 3/8" tube serves as the suction or gas return line.
Their approximate outside diameters are 6.35 mm and 9.52 mm. Refrigerant piping requirements vary by manufacturer and model, so both pipe dimensions should be verified before ordering.
75 Ft Continuous Refrigerant Piping
The 75 ft / 22.86 m continuous coil provides additional routing distance for compatible installations where shorter 25 ft or 50 ft line sets cannot reach the required equipment location.
Where permitted by the equipment manufacturer, a continuous long line set can reduce intermediate refrigerant piping joints compared with connecting multiple shorter copper sections.
C12200 DHP Copper Tubing
High-purity copper provides good formability, thermal conductivity and corrosion resistance for professional HVAC refrigerant piping applications.
ASTM B280 and C12200 DHP specifications are available according to the ordered configuration. Buyers requiring a specific tube wall thickness or pressure performance should confirm the applicable technical data before ordering.
White PE Insulated Copper Tubing
The displayed configuration uses White PE insulation around the copper tubing. The insulation helps reduce heat transfer, limit moisture penetration and protect the tubing during handling and installation.
Multi-Layer Insulation Construction
The displayed insulation construction includes an embossed PE outer layer, a dense-cell foam middle layer and a closed-cell inner insulation structure.
OEM Printing and Private Label Supply
Company name, copper tube dimensions, coil length and other product identification can be printed on the insulation for HVAC distributors, wholesalers, importers and private-label brands.

High-Purity Copper

White PE Insulated Pipe

Protective Plastic Caps
White PE Insulation Structure
The White PE insulation system is designed to protect the refrigerant copper tubing and provide thermal insulation throughout the piping route.


Insulation Pipe Production

Insulated Pipe Warehouse

Inner Insulation Layer
Embossed PE Outer Layer
The outer layer uses embossed PE film designed to provide surface protection, wear resistance and resistance to outdoor aging conditions.
Dense-Cell Foam Middle Layer
The middle insulation layer uses dense-cell foam designed for thermal insulation, impact absorption and resistance to water penetration.
Closed-Cell Inner Layer
The inner insulation layer uses a closed-cell structure to support thermal insulation and air tightness around the copper tubing. Selected configurations are listed with a temperature range of approximately -40°C to 120°C.
Available Insulation Testing
Available insulation configurations include testing related to ASTM E84, UL 94, ASTM D1056, ASTM G21, ASTM C1427 and UL 723 according to the selected insulation material and specification. Buyers should confirm the applicable documentation for the exact product configuration being ordered.
Why Choose a 75 Ft Mini Split Long Line Set?
A 75 ft mini split long line set provides an extended-length option for compatible HVAC installations where shorter refrigerant piping cannot reach between the indoor and outdoor units.
The 22.86 m continuous coil can be useful where refrigerant piping must travel through multiple rooms, ceilings, attics, service shafts or other building spaces before reaching the outdoor equipment.
Where permitted by the equipment manufacturer, one continuous coil can reduce intermediate refrigerant piping joints compared with joining multiple shorter tubing sections.

75 Ft Long-Line Installation Considerations
Verify the Required 1/4" x 3/8" Pipe Sizes
Confirm that the exact indoor and outdoor HVAC equipment requires approximately 6.35 mm and 9.52 mm outside-diameter refrigerant tubing. Do not select pipe dimensions only from BTU capacity.
Confirm Maximum Actual Piping Length
Verify that the equipment manufacturer permits approximately 75 ft / 22.86 m of actual refrigerant piping. Some mini split systems have maximum line-length limits below this distance.
Calculate Equivalent Piping Length
Elbows, bends and routing conditions can affect equivalent refrigerant piping length. Follow the equipment manufacturer's equivalent-length calculation method where applicable.
Check Maximum Vertical Separation
If indoor and outdoor equipment are installed at different elevations, verify the maximum allowable vertical separation specified by the HVAC equipment manufacturer.
Confirm Additional Refrigerant Requirements
Some mini split systems include a factory refrigerant charge for only a specified standard line length. A 75 ft installation may require additional refrigerant according to the manufacturer's charging instructions.
Review Long-Line Installation Requirements
Some HVAC manufacturers specify additional requirements for extended refrigerant piping runs. Review the exact equipment installation manual before planning a 75 ft line set.
Support Long Horizontal and Vertical Runs
Longer refrigerant piping should be properly supported to reduce sagging, vibration and mechanical stress on the copper tubing, insulation and field connections.
Protect Insulation at Structural Penetrations
Use suitable sleeves, grommets or other protection where the insulated copper tubing passes through walls, floors, roofs or other structural openings.
Is 1/4" x 3/8" Compatible With My Mini Split?
The 1/4" x 3/8" refrigerant piping combination is used by selected ductless mini split air conditioners and heat pump systems.
Some systems in approximately 9,000–12,000 BTU classes may use these dimensions, but this is not a universal sizing rule.
Equipment with similar nominal capacity can require different refrigerant pipe dimensions. Always verify the required liquid-line and suction-line sizes for the exact equipment model.
Applications of the 75 Ft 1/4" x 3/8" Long Line Set
Ductless Mini Split Air Conditioners
Suitable for compatible ductless mini split systems that specifically require 1/4" and 3/8" refrigerant tubing and permit the required extended piping length.
Heat Pump Systems
Can be supplied for compatible heat pump systems using this paired refrigerant tube combination and extended refrigerant piping.
Multi-Level HVAC Installations
A 75 ft line set can provide additional routing flexibility where compatible indoor and outdoor units are installed on different levels, provided that the manufacturer's vertical-separation limits are followed.
Residential and Light-Commercial Projects
The extended 75 ft coil can support compatible residential and light-commercial installations where equipment layout requires a longer refrigerant piping route.
Available Mini Split Line Set Sizes
| Size | Length Options | White PE Insulation | Flame-Resistant Options |
| 1/4 + 3/8 | Current SKU: 75 ft / 22.86 m; broader production options include 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 1/2 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 5/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 5/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 3/4 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/2 + 3/4 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 7/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
Long Line Sets for HVAC Distributors
DABUND supplies pre-insulated mini split line sets to HVAC distributors, wholesalers, importers, contractors, engineering companies, project suppliers and private-label brands.
The 75 ft 1/4" x 3/8" White PE configuration provides an extended-length stocking option for buyers serving compatible ductless air conditioning and heat pump installations.
OEM and Custom Mini Split Line Set Supply
DABUND supports OEM and ODM production for HVAC distributors, importers and private-label brands.
Custom copper tube combinations
Custom coil lengths
Multiple insulation thicknesses
Company name and specification printing
Private-label packaging
Custom product identification
Bulk supply for distributors and project buyers
Why Choose DABUND Mini Split Line Sets?
HVAC Manufacturing Experience Since 2008
DABUND has manufactured HVAC components since 2008, supplying mini split line sets, insulated copper tubing and related HVAC products to international customers.
In-House Insulation Production
Insulation production capabilities support multiple thicknesses, printed identification and customized configurations for distributor and private-label requirements.
Multiple Sizes and Lengths
Multiple copper tube combinations, coil lengths and insulation thicknesses allow buyers to source different refrigerant piping configurations according to market and project requirements.
DABUND Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC components for international B2B customers.

SGS Testing and Insulation Standards
Available insulation configurations include testing related to ASTM E84, UL 94, ASTM D1056 and ASTM G21 according to the selected insulation material and product specification. Buyers should confirm the applicable documentation for the exact configuration being ordered.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions to present mini split line sets, insulated copper tubing and related HVAC products to distributors, importers and professional buyers.

Frequently Asked Questions
What is a 75 ft 1/4" x 3/8" mini split long line set?
It is a paired refrigerant piping system containing 1/4" and 3/8" outside-diameter copper tubing with pre-applied insulation. The continuous coil length is approximately 75 ft or 22.86 m.
What are the metric sizes of 1/4" and 3/8" copper tubing?
A 1/4" copper tube has an outside diameter of approximately 6.35 mm, while a 3/8" copper tube has an outside diameter of approximately 9.52 mm.
Which tube is the liquid line and which is the suction line?
On compatible systems, the 1/4" tube commonly functions as the liquid line while the 3/8" tube functions as the suction or gas line. Always verify the equipment manufacturer's piping specification.
What mini split capacity uses a 1/4" x 3/8" line set?
Some mini split systems in approximately 9,000–12,000 BTU classes may use this pipe combination, but this is not universal. Similar-capacity equipment can require different refrigerant pipe dimensions.
Can I choose the line set by BTU capacity alone?
No. Refrigerant pipe sizing depends on equipment design, refrigerant type, piping length, vertical separation and manufacturer specifications.
Can every mini split use a 75 ft refrigerant line?
No. Verify that approximately 75 ft / 22.86 m falls within the maximum actual and equivalent piping limits permitted by the exact mini split or heat pump model.
Does a 75 ft mini split line set require additional refrigerant?
It may. Some systems include a factory refrigerant charge for only a specified standard line length. Follow the equipment manufacturer's charging instructions to determine whether additional refrigerant is required.
Does vertical separation matter on a 75 ft installation?
Yes. Verify the maximum permitted vertical separation between indoor and outdoor equipment before planning an extended refrigerant piping route.
What is equivalent refrigerant piping length?
Actual length is the measured copper tubing route. Equivalent length may also account for bends and other piping conditions according to the equipment manufacturer's calculation method.
What insulation is used on this line set?
The displayed product configuration uses White PE multi-layer insulation. The exact insulation structure, thickness and applicable test documentation should be confirmed for the ordered configuration.
What insulation thicknesses are available?
Available insulation thickness options include 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm depending on the selected configuration.
Is UV-resistant insulation available?
Yes. UV-resistant PE insulation configurations are available according to the selected product specification.
What pressure rating does the copper tubing have?
Allowable working and test pressure depends on copper tube diameter, wall thickness, material specification and ordered configuration. Buyers requiring a specific pressure rating should confirm the applicable technical data before ordering.
Can DABUND customize the mini split line set?
Yes. OEM and ODM options include copper tube combinations, coil lengths, insulation thickness, printed identification and private-label packaging.
Can I get samples before placing a bulk order?
Yes. According to the current product information, DABUND can provide three sample pieces for evaluation, with the buyer covering express shipping costs. View sample information.
What payment terms are available?
Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.
What delivery terms are available?
International trade terms can include EXW, FOB, CFR and CIF according to the buyer's logistics requirements.
What is the typical delivery time?
Current product information lists typical delivery at approximately 15–20 days. Actual lead time depends on order quantity, product specification, customization and production schedule.
Who should install a 75 ft mini split long line set?
Refrigerant piping, flare or brazed connections, pressure testing, evacuation, refrigerant charging and extended-line setup should be completed by qualified HVAC personnel according to local requirements and the equipment manufacturer's instructions.