HVAC Parts are produced by Dabund Pipe since 2008 years.
White PE insulation insulated copper pipe used for split air conditioning system. 75 ft 1/4" x 1/2" ac insulated copper piping meets ASTM B280 ASTM E84 UL 94 standard.
The Mini Split Air Conditioner Line Set is twin already. So buy it now.
Key Features of 1/4" x 1/2" insulated copper pipe
1. 1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.
7. Insulation we produce by ourself, can print your company name, size, meters etc.
Copper Tube: ASTM B280 & C12200 DHP
Insulation: High density closed cells polyethylene foam
Working Temperature: meets/exceeds ASTM C 1427-07
Surface burning characteristics: UL 94, top-rated for Surface Burning Characteristics – UL 723 Flame and Spread Index less than 25 and Smoke Development Index less than 50
Meets ASTM E84 for smoke and fire (25/50)
Superior tear resistance, UV resistant
Features of pipe insulation tubing:
With embossed polyethyene film, climate resistant foam, and thickened insulated cotton, this three-layer insulated mini split copper line set is corrosion-resistant, fireproofing, flame-retarded, thermal insulation, waterproof, shockproof, sound absorption and durable.
Outer Layer: Anti-aging, UV-resistant PE fllm, wear-resistant embossed pattern, antl-aging.
Middle Layer: IXPE foam, dense cell, heat and cold-resistant, impact absorption, no water penetration, good thermal insulation. Water cross-linked PE foam.
Inner Layer: Closed-cell structure, air tightness; good thermal insulation, temperature resistant -40℃~120℃.
75 ft 1/4" x 1/2" Insulated Copper Pipe for HVACR Applications Wholesaler & Supplier
DABUND PIPE in-house tested insulate copper pipe and tubing is designed to make installation simple and quick – saving you time and money on each job.
Insulated Copper Pipe
Size | Length | Insulation White PE | Flame Resistant |
1/4+3/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
1/4+1/2 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
1/4+5/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
3/8+5/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
3/8+3/4 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
1/2+3/4 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
3/8+7/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
1/4 + 3/8 Insulated copper pipe used for 0.75TON - 1.0TON mini split air conditioner.
1/4 + 1/2 Mini split line set used for 1.5TON - 2.0TON mini split air conditioning.
1/4 + 5/8 Copper line set used for 2.0TON - 2.5TON split air conditioner system.
3/8 + 5/8 Insulated copper tube apply for 3.0TON - 4.0TON ductless mini split air conditioner.
3/8 + 3/4 Insulated copper tubing used for 4.5TON - 6.0TON split air conditioner installation.
3/8 + 7/8 Insulated copper piping apply for 6.0TON - 8.0TON ductless mini split air conditioner.
Air conditioning copper line sets 1/4 + 3/8 used for 0.75P and 1P split air conditioning.
Copper pipe kit 1/4 + 1/2 commonly used for 1.5P and 2P mini split air conditioners.
1/4 + 5/8 Insulated copper line set used for 2P and 2.5air conditioner system.
3/8 + 5/8 Mini-split copper line set apply for 3P and 4P ductless mini split air conditioner.
3/8 + 3/4 Copper pipe kit used for 4.5P and 6P split aircon installation.
3/8 + 7/8 Insulated copper piping apply for 6P - 8p TON ductless mini split air conditioner.
1/4 + 3/8 Mini split line set used for 9000BTU and 12000 BTU split air conditioner.
All copper line set 1/4 + 1/2 commonly used for 12000 BTU and 18000 BTU mini split air conditioners.
1/4 + 5/8 Insulated copper line set used for 24000 BTU and 30000 BTU air conditioner system.
3/8 + 5/8 Mini-split line set apply for 36000 BTU and 48000 ductless air conditioner.
3/8 + 3/4 Insulated copper pipe used for 54000 BTU and 72000 split air conditioner installation.
3/8 + 7/8 Insulated copper piping apply for 72000 BTU - 96000 BTU ductless mini split air conditioner.
Aircon copper line set 1/4 + 3/8 used for 9K and 12K split air conditioner.
High quality copper line set 1/4 + 1/2 commonly used for 12K and 18K mini split air conditioners.
1/4 + 5/8 Insulated copper line set used for 24K and 30K air conditioner system.
3/8 + 5/8 Mini-split line set apply for 36K and 48K ductless air conditioner.
3/8 + 3/4 HVAC line set used for 54K and 72K split air conditioner installation.
3/8 + 7/8 Insulated copper piping apply for 72K - 96K ductless mini split air conditioner.
Why Choose 75 ft 1/4" x 1/2" Insulated Copper Pipe from DABUND PIPE
We are manufacturer of insulated copper pipe since 2008 years, have good experience of producing and exporting. We have cooperated 9 years forwarder, can guarantee the shipment. Every week we load at least 6-8 40HQ to different countries. Choose Dabund You will win the business.
Individual pre-insulated rolls to perfectly fit every ductless mini-splits, VRF, heat pumps and unitary systems installation.
Quality products with competitive pricing
Peace of mind with professional services
DABUND FACTORY
We produce Insulated Copper Pipe, Mini Split Line Set and Aluminum Pipe and HVAC Parts
SGS Certificate
Mini Split Line Set is made of Polypropylene or Black Rubber with UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21
Exhibition
We join the exhibitions all over the word, just to facilitate customers to experience our mini split line set face to face.
FAQ
1.Q:What is your payment terms?
A:TT,L/C AT SIGHT,CREDIT CARD etc
2.Q:What is your delivery terms?
A:EXW, FOB, CFR, CIF etc
3.Q:Are you trading company or manufacturer?
A:Manufacturer
4.Q:May I get a sample?
A:Yes, we can send you 3pieces free samples.
You just charge for the express cost is ok.
5.Q:Can I print my logo?
A:Yes of cause, we accept OEM and ODM.
6.Q:How long is your delivery time?
A:Usually 15-20days, if urgent, we can arrange to do in advance and delivery fast.