50 ft 3/8 in. x 3/4 in. Mini Split Installation Kit
The DABUND 50 ft 3/8 in. x 3/4 in. Mini Split Installation Kit is a complete HVAC installation package for compatible ductless mini split systems, heat pumps, split air conditioners and light commercial HVAC projects.
The kit combines a 50 ft pre-insulated copper refrigerant line set with communication wire, drain hose, wall sleeve, decorative wall cover and related installation accessories to reduce separate component sourcing for HVAC contractors and distributors.
The refrigerant tubing uses a 3/8 in. liquid line and a 3/4 in. suction line made from 99.9% pure copper. Black Rubber is the primary insulation configuration shown on this page, while PE insulation is also available.
Quick Answer: The 3/8 x 3/4 line-set family is generally referenced for compatible 4.5–6.0 ton / 54,000–72,000 BTU HVAC systems. Final pipe-size selection must follow the equipment manufacturer's exact refrigerant-line requirements, refrigerant type, permitted piping length and charging instructions.
50 ft Mini Split Installation Kit Video
What Is Included in the 50 ft Installation Kit?
| Insulated Copper Line Set | 3/8 in. + 3/4 in., 50 ft / approximately 15.24 m |
| Liquid Line | 3/8 in. / approximately 9.52 mm |
| Suction Line | 3/4 in. / approximately 19.05 mm |
| Communication Wire | Included according to kit configuration |
| Drain Hose | Included according to kit configuration |
| Wall Sleeve | Included |
| Decorative Wall Cover | Included |
| Flare Nuts / Installation Accessories | Included according to kit configuration |
Communication-wire conductor count, wire gauge, voltage rating, drain-hose dimensions and exact accessory quantities should be confirmed for the ordered kit configuration.
Why Choose a Complete Mini Split Installation Kit?
Combining the refrigerant line set and key HVAC installation accessories in one package helps simplify procurement and reduce the number of separate components contractors need to source for each project.
Pre-insulated copper refrigerant tubing
Communication wiring
Condensate drainage components
Wall penetration accessories
Flare nuts and related installation parts
OEM accessory combinations available
99.9% Pure Copper Refrigerant Line Set
The copper refrigerant tubing is specified as 99.9% pure copper for compatible HVAC applications.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for mini split, heat-pump and split-system refrigerant piping.
3/8 in. Liquid Line and 3/4 in. Suction Line
This kit uses a 3/8 in. liquid line and a 3/4 in. suction line for compatible HVAC equipment requiring these exact copper tube dimensions.
Refrigerant-line dimensions vary by equipment brand, model and system design. Always verify the required pipe sizes from the HVAC equipment installation manual before ordering.
General 54,000–72,000 BTU Capacity Reference
The wider DABUND line-set family lists the 3/8 in. + 3/4 in. configuration as a general reference for some 4.5–6.0 ton HVAC systems.
The corresponding family reference is approximately 54,000–72,000 BTU.
Capacity references vary by equipment model. Select the installation kit according to the manufacturer's required refrigerant-line dimensions rather than nominal system capacity alone.
Copper Line Set and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Flared Copper Pipe
Black Rubber Pipe Insulation
Black Rubber is the primary insulation configuration shown for this installation kit.
The closed-cell rubber structure helps provide thermal insulation and moisture resistance around the copper refrigerant lines.
Black Rubber insulation configuration
Listed temperature range from -40°C to 120°C
Moisture and condensation resistance
Thermal insulation and moisture barrier in one structure
Suitable for compatible indoor and outdoor HVAC installations

PE Insulation Option
PE insulation is also available according to the selected kit configuration. Buyers can choose insulation material according to project requirements, target market and environmental conditions.
Pressure and Temperature Specifications
Product specifications list a copper tubing pressure range of approximately 2100–7000 PSI.
Actual allowable working pressure depends on copper diameter, wall thickness, operating temperature and the exact product configuration, so the listed range should not be treated as a universal working-pressure rating.
Applicable insulation configurations are listed for a temperature range from approximately -40°C to 120°C. Confirm the applicable rating for the exact insulation material ordered.
Complete 50 ft Mini Split Installation Kit
This product is configured as a complete installation kit rather than only an insulated copper line set. The packaged accessories help installers source the main refrigerant, drainage, communication and wall-penetration components together.

Technical Specifications
| Parameter | Details |
|---|
| Brand | DABUND |
| Product Name | 50 ft 3/8 in. x 3/4 in. Mini Split Air Conditioner Installation Kit |
| Line Set Size | 3/8 in. Liquid Line + 3/4 in. Suction Line |
| Length | 50 ft / approximately 15.24 m |
| Material | 99.9% Pure Copper |
| Insulation Options | PE / Black Rubber |
| Listed Pressure Range | 2100–7000 PSI according to specification |
| Listed Temperature Range | -40°C to 120°C for applicable insulation configurations |
| Included Accessories | Communication Wire, Drain Hose, Wall Sleeve, Decorative Cover and Installation Accessories |
| General Capacity Reference | 4.5–6.0 Ton / 54,000–72,000 BTU |
| Applications | Mini Split AC / Heat Pump / Ductless HVAC / Split Air Conditioner / Light Commercial HVAC |
Available Mini Split Installation Kit Sizes
| Size | Standard Family Lengths | Black Rubber Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 3 / 4 / 5 / 7 / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 50 ft / approximately 15.24 m. The family table lists shorter standard metric kit lengths, so buyers should specify the exact finished 50 ft configuration when ordering.
Mini Split Line Set Size Guide
| Line Set Size | General Ton Range | General BTU Range | Common Application |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU | Small Mini Split AC |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU | Residential Mini Split |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU | Medium Split AC |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU | Large Residential / Light Commercial HVAC |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU | Commercial Split AC |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU | Large Ductless HVAC |
These capacity values are general product-family references only. The HVAC equipment manufacturer's specified refrigerant-line sizes always take priority.
Important Checks for a 50 ft Installation
Confirm Exact Refrigerant Line Sizes
Verify that the selected HVAC equipment specifically requires a 3/8 in. liquid line and 3/4 in. suction line.
Verify Maximum Permitted Piping Length
Confirm that the HVAC equipment manufacturer permits the proposed 50 ft refrigerant-line route.
Check Minimum Permitted Piping Length
Some HVAC systems also specify a minimum refrigerant piping length. Confirm both minimum and maximum limits before installation.
Check Maximum Elevation Difference
If indoor and outdoor units are installed at different elevations, verify the manufacturer's maximum permitted vertical separation.
Check Additional Refrigerant Charge
A 50 ft refrigerant run may require additional refrigerant depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions.
Check Equivalent Piping Length
Bends, fittings and elevation changes can increase equivalent piping length beyond the physical 50 ft tube length. Follow the equipment manufacturer's engineering limits for the complete route.
Confirm Communication Wire Specification
Communication wire is included according to the kit configuration. Confirm conductor count, wire gauge, voltage rating and equipment compatibility before installation.
Installation Guidelines
Measure the complete refrigerant, electrical and drainage route before installation.
Use suitable HVAC tube-bending methods and avoid sharp bends or kinks.
Maintain continuous insulation coverage around the refrigerant lines.
Protect tubing and insulation at wall penetrations.
Inspect flare surfaces and flare nuts before connection.
Tighten refrigerant connections according to the equipment manufacturer's specified torque.
Route the drain hose with suitable slope according to the indoor-unit instructions.
Pressure-test and leak-test the refrigerant circuit before startup.
Evacuate the refrigerant circuit according to the equipment manufacturer's procedure.
Add refrigerant when required for the actual installed piping length.
OEM and Custom Mini Split Installation Kits
Custom copper line-set sizes
Custom line-set lengths
PE or Black Rubber insulation
Custom insulation thickness
Logo and insulation printing
Custom accessory combinations
Private-label packaging
OEM and ODM production
Packaging and Delivery
Standard export packaging
Custom packaging available
Private-label packaging available
Typical delivery time: approximately 15–20 days
Production scheduling depends on order quantity and customization requirements
DABUND Mini Split Installation Kit Factory
DABUND manufactures mini split installation kits, insulated copper line sets, HVAC copper tubing, aluminum pipes and related HVAC components for international distributors, contractors, wholesalers and OEM buyers.

Insulation Test Documentation
Applicable Polypropylene or Black Rubber insulation configurations are available with UV-resistant options and corresponding ASTM E84, UL94, ASTM D1056 and ASTM G21 test references.
Black Rubber is the primary insulation configuration shown on this page. Buyers requiring compliance documentation should confirm the exact insulation material, thickness and matching test report for the ordered kit.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review mini split installation kits, line sets, insulated copper pipes and related HVAC products.

Frequently Asked Questions
What is included in the 50 ft mini split installation kit?
The kit includes a 50 ft 3/8 x 3/4 insulated copper line set, communication wire, drain hose, wall sleeve, decorative wall cover and related installation accessories.
What HVAC capacity commonly uses a 3/8 x 3/4 line set?
The wider DABUND line-set family lists 3/8 x 3/4 as a general reference for some 4.5–6.0 ton or 54,000–72,000 BTU systems. Final pipe sizing must follow the equipment manufacturer's exact requirements.
How long is this copper line set?
This SKU is 50 ft long, approximately 15.24 m.
What copper material is used?
Product specifications list 99.9% pure copper.
What insulation options are available?
Black Rubber and PE insulation options are available. Black Rubber is the primary configuration shown on this page.
What is the listed insulation temperature range?
Applicable insulation configurations are listed for approximately -40°C to 120°C. Confirm the applicable rating for the exact insulation material ordered.
What is the listed pressure range?
Product information lists a 2100–7000 PSI range. Actual allowable working pressure depends on copper diameter, wall thickness, operating temperature and exact configuration.
Does the kit include communication wire?
Yes. Communication wire is included according to the kit configuration. Confirm conductor count, wire gauge, voltage rating and equipment compatibility before ordering.
Does the kit include a drain hose?
Yes. A drain hose is included according to the kit configuration. Confirm the exact hose length and dimensions before ordering.
Are the copper pipe ends flared?
Flared copper pipe ends are shown for this installation-kit configuration. Confirm the flare dimensions and supplied nuts against the HVAC equipment specification before ordering.
Is 50 ft suitable for every compatible HVAC system?
No. Confirm the equipment manufacturer's maximum and minimum permitted piping lengths, elevation limits and refrigerant-charge requirements before installation.
Does a 50 ft refrigerant run require additional refrigerant?
It may. Additional refrigerant depends on the equipment's factory charge and included piping allowance. Follow the equipment manufacturer's charging instructions.
Can this kit be used with heat pumps?
Yes, when the heat-pump manufacturer specifies the same refrigerant-line dimensions and the complete installation requirements match.
Can this installation kit be customized?
Yes. DABUND supports custom line-set lengths, copper tube sizes, insulation materials, insulation thickness, logo printing, accessory combinations and packaging design.
Is DABUND a manufacturer?
Yes. DABUND manufactures mini split installation kits, insulated copper line sets, HVAC copper tubing, aluminum pipes and related HVAC parts.
Are samples available before bulk ordering?
Samples can be provided for evaluation, with buyers generally covering express shipping costs.
What payment terms are available?
T/T, L/C at sight and credit card are listed among common payment methods, subject to order details.
What delivery terms are available?
EXW, FOB, CFR and CIF are listed among available international delivery terms.
What is the typical delivery time?
Typical delivery time is approximately 15–20 days, subject to order quantity, customization requirements and production scheduling.
Is professional HVAC installation recommended?
Yes. Refrigerant piping, electrical wiring, drainage, flare connections, leak testing, evacuation, charging and commissioning should follow the HVAC equipment manufacturer's instructions and applicable local requirements.