50 ft 3/8 in. x 5/8 in. Mini Split Long Line Set
DABUND 50 ft 3/8 in. x 5/8 in. Mini Split Long Line Set provides a pre-insulated copper refrigerant piping solution for compatible mini split air conditioners, ductless HVAC systems and heat pumps requiring an extended line run.
The paired refrigerant tubing includes a 3/8 in. liquid line and 5/8 in. suction line with a continuous length of 50 ft, approximately 15.24 m.
The tubing is manufactured from 99.9% pure copper and supplied with factory-applied insulation to help reduce thermal transfer, control condensation and simplify installation between compatible indoor and outdoor HVAC equipment.
Quick Answer: This 50 ft 3/8 x 5/8 mini split line set combines a 3/8 in. liquid line and 5/8 in. suction line in a continuous pre-insulated copper coil for compatible ductless AC and heat-pump installations.
50 ft Mini Split Long Line Set Video
50 ft 3/8 x 5/8 Line Set Specifications
| Feature | Specification |
|---|
| Product Type | Pre-Insulated Mini Split Long Line Set |
| Line Set Size | 3/8 in. x 5/8 in. |
| Liquid Line | 3/8 in. / approximately 9.52 mm |
| Suction Line | 5/8 in. / approximately 15.88 mm |
| Length | 50 ft / approximately 15.24 m |
| Material | 99.9% Pure Copper |
| Insulation | Factory-Applied Thermal Insulation |
| Featured Insulation | White PE Configuration Shown |
| Applications | Compatible mini split, ductless AC and heat-pump systems |
| Listed Refrigerants | R410A, R32 and other compatible HVAC refrigerants |
| Installation | Pre-Insulated for Compatible HVAC Installation |
3/8 in. Liquid Line and 5/8 in. Suction Line
The line set combines a 3/8 in. liquid line with a 5/8 in. suction line for compatible split-system and ductless HVAC refrigerant circuits.
The 3/8 in. tube carries refrigerant through the liquid side of the system, while the 5/8 in. tube serves as the suction return line for compatible equipment.
Always confirm that the HVAC equipment manufacturer specifies a 3/8 in. liquid line and 5/8 in. suction line before ordering. Refrigerant pipe sizes should not be selected only by nominal system capacity.
50 ft Length for Extended Mini Split Installations
The 50 ft continuous line set provides additional routing flexibility where indoor and outdoor units cannot be installed close together.
It can be suitable for compatible multi-story homes, offices, rooftop installations and other layouts where a shorter line set does not provide sufficient reach.
Using a continuous 50 ft coil can also reduce the need for intermediate refrigerant-line connections compared with joining several shorter tubing sections.
99.9% Pure Copper Refrigerant Tubing
The refrigerant tubing is manufactured from 99.9% pure copper for compatible HVAC refrigerant piping applications.
Copper provides thermal conductivity, corrosion resistance and flexibility for routing between compatible indoor and outdoor HVAC equipment.
Factory-Applied Insulation
Factory-applied insulation helps reduce unwanted heat gain and heat loss along the refrigerant line while helping control surface condensation on cold tubing.
Pre-insulated construction also reduces additional field insulation work and provides consistent coverage around the refrigerant tubing.
The current product images show a White PE insulated configuration. Buyers requiring a specific insulation material or certification should confirm the selected configuration before ordering.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Protective Plastic Cap
White PE Insulation
The featured line set configuration uses White PE insulation around the copper refrigerant tubing.
The insulation provides a protective thermal layer to help reduce heat exchange and surface condensation along the refrigerant line.

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
Compatible HVAC Applications
Compatible mini split air conditioners
Ductless heat-pump systems
Residential HVAC installations
Light commercial HVAC projects
Multi-story installations requiring extended refrigerant piping
Compatible rooftop HVAC equipment
Refrigerant Compatibility
The source product information lists R410A and R32 among the commonly used refrigerants for compatible mini split and HVAC installations.
Final refrigerant compatibility, allowable pressure, required tube sizes and connection requirements should be verified against the specific HVAC equipment manufacturer's technical documentation.
Benefits of the 50 ft Mini Split Long Line Set
Extended Installation Reach
The 50 ft length provides additional routing flexibility for installations where the indoor and outdoor units are separated by a moderate distance.
Reduced Intermediate Connections
A continuous 50 ft coil can reduce the need for intermediate refrigerant-line extensions or couplings on compatible installations.
Condensation Control
Factory insulation helps reduce condensation on cold refrigerant tubing and limits moisture exposure near walls and structural penetrations.
Thermal Protection
Pre-insulated tubing helps reduce unwanted thermal exchange between the refrigerant and surrounding environment during system operation.
Reduced Field Insulation Work
Factory-applied insulation reduces additional field wrapping and provides more consistent insulation coverage along the line set.
Important Considerations for a 50 ft Line Set
Verify Maximum Permitted Line Length
Confirm that the HVAC equipment manufacturer permits at least 50 ft of total refrigerant piping before selecting this line set.
Check Maximum Elevation Difference
When the indoor and outdoor units are installed at different heights, confirm the maximum vertical separation permitted by the equipment manufacturer.
Check Additional Refrigerant Requirements
Depending on the HVAC equipment and total installed refrigerant-line length, additional refrigerant may be required. Follow the equipment manufacturer's charging instructions.
Confirm the Exact Tube Sizes
Confirm that the HVAC equipment specifically requires a 3/8 in. liquid line and 5/8 in. suction line before installation.
Installation Guidelines
Measure the Complete Line Route
Measure the entire route between the indoor and outdoor HVAC equipment before installation to confirm that the 50 ft line set provides sufficient length.
Avoid Sharp Bends and Kinks
Use suitable bending methods and bend radii to reduce the risk of kinking the copper tubing or restricting refrigerant flow.
Protect Insulation at Wall Penetrations
Use wall sleeves, grommets or suitable protection where the insulated line set passes through walls or other structural openings.
Support the Refrigerant Tubing
Use suitable HVAC-rated clips, straps or support brackets along the piping route to reduce sagging, vibration and mechanical stress on the tubing and insulation.
Follow the Equipment Manufacturer's Instructions
Refrigerant piping, connection preparation, evacuation, charging and system commissioning should follow the HVAC equipment manufacturer's installation requirements.
50 ft White PE Insulated Copper Line Set
The featured White PE configuration combines factory-insulated copper refrigerant tubing with a continuous 50 ft coil for compatible mini split and ductless HVAC installations.

Available Mini Split Line Set Sizes
| Line Set Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
General Line Set Size and Capacity Reference
The following capacity ranges are general references from the wider DABUND line set family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact piping specifications.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000 / 12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000 / 18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000 / 30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000 / 48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000 / 72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
For the 3/8 x 5/8 configuration, the product family lists 3.0–4.0 ton and 36,000–48,000 BTU as general references. Actual compatibility must be confirmed from the HVAC equipment manufacturer's required liquid-line and suction-line dimensions.
Why Choose the DABUND 50 ft Mini Split Long Line Set?
High-Purity Copper Construction
The product uses 99.9% pure copper tubing for compatible HVAC refrigerant-line applications.
Factory-Insulated for Faster Installation
Factory-applied insulation reduces separate field insulation work and helps provide consistent coverage along the refrigerant tubing.
Extended 50 ft Installation Flexibility
The 50 ft continuous length provides additional routing flexibility for compatible residential and light commercial HVAC projects.
DABUND Mini Split Line Set Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation products for distributors and project customers.

Insulation Test Documentation
The source certificate section references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber insulation configurations.
Because the featured product images on this page show White PE insulation, buyers requiring specific project documentation should confirm the selected insulation material, insulation thickness and corresponding test reports before ordering.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where distributors and professional buyers can review insulated copper tubing, mini split long line sets and related HVAC installation products.

Frequently Asked Questions
What does 3/8 in. x 5/8 in. mean?
It refers to the outside diameters of the two copper refrigerant tubes: 3/8 in. for the liquid line and 5/8 in. for the suction line.
How long is this mini split line set?
The line set is 50 ft long, equivalent to approximately 15.24 m.
What material is the refrigerant tubing made from?
The source product information lists 99.9% pure copper tubing.
Is this line set pre-insulated?
Yes. The copper refrigerant tubing is supplied with factory-applied thermal insulation.
What insulation configuration is shown?
The featured product images show a White PE insulated configuration.
What insulation thicknesses are available?
The wider product family lists White PE insulation thicknesses of 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.
What size HVAC system can use a 3/8 x 5/8 line set?
The DABUND product family lists 3/8 x 5/8 as a general reference for some 3.0–4.0 ton or 36,000–48,000 BTU systems. Final refrigerant-line sizing must follow the equipment manufacturer's required pipe dimensions.
Can every mini split use a 50 ft line set?
No. Confirm the required liquid-line and suction-line sizes, maximum permitted piping length, elevation difference and connection requirements for the specific HVAC system.
Does a 50 ft line set require additional refrigerant?
Additional refrigerant may be required depending on the HVAC equipment and total installed line length. Follow the equipment manufacturer's refrigerant charging instructions.
Is this line set compatible with R410A and R32?
The source product information lists R410A and R32 among the compatible refrigerants. Final compatibility should be confirmed against the HVAC equipment manufacturer's technical specifications.
Can this mini split line set be installed outdoors?
The source product information describes the applicable insulation jacket as suitable for compatible outdoor refrigerant-line installations. Confirm the insulation configuration and project exposure requirements before installation.
Is additional field insulation required?
Factory-applied insulation reduces additional field wrapping, although local codes, installation conditions and project specifications may require additional protection.
What other mini split line set sizes are available?
Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
What production lengths are available?
The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths.
Is DABUND a manufacturer?
Yes. The source product information identifies DABUND as the manufacturer.
Can DABUND provide free samples?
Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer paying the express freight. View Sample Information
What payment terms are available?
The listed payment options include T/T, L/C at sight and credit card.
What delivery terms are available?
Listed delivery terms include EXW, FOB, CFR and CIF.
Does DABUND support OEM and ODM?
Yes. OEM and ODM services, including logo customization, are available for suitable orders.
What is the typical delivery time?
The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.