50 ft 3/8 in. x 5/8 in. Mini Split Long Line Set
DABUND 50 ft 3/8 in. x 5/8 in. Mini Split Long Line Set provides pre-insulated copper refrigerant tubing for compatible ductless air conditioners, heat pumps, split-system HVAC equipment and extended refrigerant piping installations.
The paired refrigerant tubing combines a 3/8 in. liquid line with a 5/8 in. suction line. The source product information specifies a 50 ft length, 99.9% pure seamless copper construction and factory-prepared flare connections with matching nuts.
The featured configuration uses factory-applied White PE insulation to help reduce thermal exchange, control condensation and protect the copper refrigerant tubing during compatible HVAC installation.
Quick Answer: This 50 ft 3/8 x 5/8 mini split long line set combines high-purity copper tubing, White PE insulation and pre-flared ends for compatible long-run ductless AC and heat-pump installations.
50 ft Mini Split Long Line Set Video
50 ft 3/8 x 5/8 Line Set Specifications
| Product Type | Pre-Insulated Mini Split Refrigerant Line Set |
| Line Set Size | 3/8 in. x 5/8 in. |
| Liquid Line | 3/8 in. / approximately 9.52 mm |
| Suction Line | 5/8 in. / approximately 15.88 mm |
| Length | 50 ft; source product information lists approximately 15 m |
| Copper Material | 99.9% Pure Seamless Copper |
| Tube Ends | Pre-Flared Ends with Matching Nuts |
| Insulation | Factory-Applied Thermal Insulation |
| Featured Insulation | White PE Configuration Shown |
| Applications | Compatible Mini Split, Ductless AC, Heat Pump and Light Commercial HVAC Systems |
3/8 in. Liquid Line and 5/8 in. Suction Line
The paired copper tubing combines a 3/8 in. liquid refrigerant line with a 5/8 in. suction return line.
Before ordering, verify that the specific HVAC equipment requires these exact refrigerant piping diameters.
Refrigerant-line dimensions should not be selected only by nominal system capacity because required liquid and suction pipe sizes can vary between HVAC equipment manufacturers and models.
50 ft Long Line Set for Extended HVAC Installations
The 50 ft line set provides additional routing flexibility where compatible indoor and outdoor HVAC equipment are separated by a moderate distance.
It can be used in compatible residential split systems, multi-zone mini split installations, heat-pump projects, light commercial HVAC systems and replacement applications requiring an extended refrigerant piping route.
Before installation, confirm the HVAC equipment manufacturer's maximum permitted refrigerant piping length, maximum elevation difference and additional refrigerant charging requirements.
99.9% Pure Seamless Copper Refrigerant Tubing
The source product information specifies 99.9% pure copper with seamless construction for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and flexibility for routing refrigerant piping between compatible indoor and outdoor HVAC equipment.
Factory-Prepared Flare Connections
The refrigerant tubing is supplied with pre-flared ends and matching nuts to reduce field tube preparation during compatible HVAC installation.
Installers should inspect the flare surfaces before connection and follow the HVAC equipment manufacturer's specified tightening procedure and torque requirements.
Factory-Applied White PE Insulation
The featured product configuration uses White PE insulation around the copper refrigerant tubing.
Factory-applied insulation helps reduce unwanted thermal exchange and surface condensation while protecting the refrigerant line from moisture and environmental exposure.
The source product information also describes the insulation jacket as resistant to UV exposure and moisture. Buyers requiring specific outdoor-performance or compliance documentation should confirm the exact ordered insulation configuration.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Protective Plastic Cap
White PE Insulated Copper Pipe
White PE insulation provides a thermal and protective layer around the refrigerant tubing to help reduce heat exchange and condensation during compatible HVAC operation.

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
Benefits of the 50 ft Mini Split Long Line Set
Extended Installation Reach
The 50 ft length provides additional routing flexibility for compatible HVAC projects where indoor and outdoor equipment cannot be installed close together.
Reduced Field Tube Preparation
Pre-flared connections with matching nuts reduce onsite tube-end preparation when the factory flare dimensions match the selected equipment.
Condensation Control
Factory-applied insulation helps reduce condensation on cold refrigerant tubing and limits moisture exposure around walls and structural penetrations.
Thermal Protection
Insulation helps reduce unwanted thermal exchange between the refrigerant piping and the surrounding environment.
Compatible HVAC Applications
Compatible residential split air conditioners
Ductless mini split systems
Multi-zone mini split installations
Heat-pump systems
Light commercial HVAC projects
Replacement and retrofit refrigerant-line installations
Final compatibility should be confirmed from the equipment manufacturer's required liquid-line size, suction-line size, connection dimensions and maximum permitted piping length.
Important Considerations for a 50 ft Refrigerant Line
Confirm Maximum Permitted Line Length
Confirm that the HVAC equipment manufacturer permits the required 50 ft refrigerant piping route before installation.
Check Maximum Elevation Difference
If the indoor and outdoor units are installed at different elevations, verify the maximum vertical separation permitted by the equipment manufacturer.
Check Additional Refrigerant Requirements
Additional refrigerant may be required depending on the HVAC equipment, factory refrigerant charge and total installed piping length. Follow the equipment manufacturer's charging instructions.
Confirm the Exact Pipe Sizes
Verify that the specific HVAC equipment requires a 3/8 in. liquid line and 5/8 in. suction line.
Support the Refrigerant Tubing
Use suitable HVAC-rated supports, clips or brackets along the piping route to reduce sagging, vibration and mechanical stress on the tubing and insulation.
Installation Guidelines
Measure the Required Refrigerant Run
Measure the complete piping route before installation to confirm that the 50 ft line set provides suitable length for the project.
Inspect the Pre-Flared Connections
Inspect the flare surfaces and matching nuts before connection and follow the HVAC equipment manufacturer's tightening procedure and torque requirements.
Avoid Sharp Bends and Kinks
Use suitable bending methods and bend radii to reduce the risk of copper tube deformation or restricted refrigerant flow.
Maintain Insulation Coverage
Avoid cutting, crushing or leaving unnecessary gaps in the insulation during installation.
Follow Equipment Manufacturer Instructions
Refrigerant piping, flare connections, evacuation, refrigerant charging and system commissioning should follow the specific HVAC equipment manufacturer's installation instructions.
50 ft White PE Copper Line Set
The featured White PE configuration combines factory-insulated copper refrigerant tubing with pre-flared connections for compatible extended mini split and heat-pump installations.

Available Mini Split Line Set Sizes
| Line Set Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
General Line Set Size and Capacity Reference
The following capacity ranges are general references from the wider DABUND mini split line set family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact piping requirements.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
For the 3/8 x 5/8 configuration, the DABUND product family lists 3.0–4.0 ton and 36,000–48,000 BTU as general references. Actual compatibility must be determined from the exact refrigerant piping requirements of the HVAC equipment.
Why Choose the DABUND 50 ft 3/8 x 5/8 Line Set?
50 ft Extended Refrigerant Run
The extended length provides routing flexibility for compatible installations requiring greater separation between indoor and outdoor HVAC equipment.
99.9% Pure Seamless Copper
High-purity copper construction provides flexible refrigerant tubing for compatible residential and light commercial HVAC projects.
Factory-Prepared Flare Connections
Pre-flared tube ends and matching nuts reduce field preparation where the connection dimensions match the selected HVAC equipment.
Factory-Applied Insulation
Pre-insulated construction reduces additional field insulation work and helps maintain consistent thermal protection along the refrigerant piping.
DABUND Mini Split Line Set Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC products for distributors, contractors and project customers.

Insulation Test Documentation
The source certificate section references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber insulation configurations.
Because the featured product images on this page show White PE insulation, buyers requiring compliance documentation should confirm the exact insulation material, thickness and corresponding test report for the ordered configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where distributors and professional buyers can review insulated copper tubing, mini split line sets and related HVAC products.

Frequently Asked Questions
What does 3/8 in. x 5/8 in. mean?
It refers to the outside diameters of the two refrigerant tubes: 3/8 in. for the liquid line and 5/8 in. for the suction return line.
How long is this mini split line set?
The product is specified as a 50 ft long line set. The source product information also lists the length as approximately 15 m.
What material is the refrigerant tubing made from?
The source product information specifies 99.9% pure seamless copper.
Are the line set ends pre-flared?
Yes. The source product information specifies pre-flared ends with matching nuts.
What insulation material is shown?
The featured product images show White PE insulated copper tubing.
What White PE insulation thicknesses are available?
The wider product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm White PE insulation options.
What size HVAC system can use a 3/8 x 5/8 line set?
The DABUND product family lists 3/8 x 5/8 as a general reference for some 3.0–4.0 ton or 36,000–48,000 BTU systems. Final line-set sizing must follow the HVAC equipment manufacturer's exact refrigerant piping requirements.
Is this line set compatible with every mini split brand?
Compatibility should be confirmed for each HVAC model. Verify the required liquid-line diameter, suction-line diameter, flare connection dimensions, permitted piping length and refrigerant requirements before installation.
Can a 50 ft line set be used on every mini split?
No. Confirm the equipment manufacturer's maximum permitted refrigerant piping length and maximum elevation difference before installation.
Does a 50 ft line set require additional refrigerant?
Additional refrigerant may be required depending on the HVAC equipment, factory refrigerant charge and total installed piping length. Follow the equipment manufacturer's charging instructions.
Can the 50 ft copper line set be shortened?
Yes. The source product information states that the copper tubing can be trimmed to the required length. If shortened, use appropriate HVAC cutting, deburring, flaring and sealing procedures.
Can the line set be installed outdoors?
The source product information describes the insulation jacket as resistant to UV exposure and moisture. Final outdoor suitability should be confirmed for the selected insulation configuration and project exposure conditions.
Is additional insulation required?
The copper tubing is factory pre-insulated. Additional protection may still be required depending on local requirements, wall penetrations, outdoor exposure or project specifications.
What other mini split line set sizes are available?
Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
What production lengths are available?
The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths.
Is DABUND a manufacturer?
Yes. The source product information identifies DABUND as a manufacturer of mini split line sets and related HVAC products.
Can DABUND provide free samples?
Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer responsible for express freight. View Sample Information
What payment terms are available?
Listed payment options include T/T, L/C at sight and credit card.
What delivery terms are available?
Listed delivery terms include EXW, FOB, CFR and CIF.
Does DABUND support OEM and ODM?
Yes. OEM and ODM services, including logo customization, are available for suitable orders.
What is the typical delivery time?
The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.