50 Ft 1/4" x 5/8" Insulated Copper Pipe for Air Conditioning
The DABUND 50 ft 1/4" x 5/8" insulated copper pipe is designed for compatible mini split air conditioners, heat pumps, centralized ducted air-conditioning units, VRF systems and HVACR refrigeration applications.
The paired refrigerant line combines a 1/4-inch liquid line and a 5/8-inch suction line with Black Rubber insulation or customized insulation options for professional HVAC installation.
DABUND has produced insulated copper pipe, mini split line sets, air-conditioning copper tubing, aluminum pipe and HVAC parts since 2008 for contractors, wholesalers, distributors, importers and OEM buyers.
Compatibility Notice: Confirm the required copper line size, tube wall thickness, refrigerant, maximum permitted piping length, flare or connection method, insulation thickness and pressure requirements in the connected equipment manufacturer's installation manual before ordering.
Product Specifications
Product Name
50 Ft 1/4" x 5/8" Insulated Copper Pipe for Air Conditioning
Product Type
Insulated copper pipe / AC copper line set / HVAC refrigerant line set
Copper Line Size
1/4" x 5/8"
Metric Size
6.35 mm x 15.88 mm outside diameter
Length
50 ft / approximately 15 m
Copper Material
99.9% pure copper; C12200 DHP copper option available
Copper Standard
ASTM B280 configuration available for HVAC and refrigeration field service
Insulation Material
Black Rubber insulation or customized insulation material
Insulation Thickness
3/8", 1/2" or customized thickness; 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm options available
Working Temperature
-40°C to 120°C for the stated Black Rubber insulation configuration
Pressure Range
Available copper configurations are specified within a 2100–7000 PSI range. Actual allowable working pressure depends on tube diameter, wall thickness, operating temperature and exact specification.
Available Test Reports
ASTM E84, UL 94, ASTM D1056, ASTM G21 and related insulation documentation
Application
Ductless mini split, heat pump, centralized ducted unit, air conditioning, refrigeration and HVACR installation
Customization
Length, copper size, insulation thickness, insulation color, printing, company name, size marking, meter marking, packaging and OEM branding
Key Features of 50 Ft 1/4" x 5/8" Insulated Copper Pipe
1/4" x 5/8" Copper Line Size
The 1/4" x 5/8" specification refers to the outside diameters of the paired copper tubes, approximately 6.35 mm x 15.88 mm.
This tubing combination should be used only with equipment that specifies this exact liquid-line and suction-line size.
99.9% Pure Copper Tube
The copper tubing is available in 99.9% pure copper, with C12200 DHP copper and ASTM B280 configurations available according to the required specification.
Copper wall thickness and pressure capability should be selected according to tube diameter, refrigerant, system design pressure and equipment requirements.
Black Rubber Insulation for Air Conditioning
Black Rubber insulation provides flexible closed-cell thermal coverage around the copper refrigerant tubing and helps reduce unwanted heat transfer and surface condensation.
UV-resistant insulation options are available for projects requiring outdoor exposure protection. Confirm the exact insulation grade and required protective covering before installation.
HVACR Application Compatibility
This insulated copper pipe can be used with compatible ductless mini split systems, heat pumps, centralized ducted air-conditioning units, refrigeration systems and other HVACR equipment that specifies a 1/4" liquid line and a 5/8" suction line.
Custom Printing and OEM Supply
DABUND produces insulation in-house and can print company name, tube size, meter markings, brand information and product specifications on the insulation surface for OEM and private-label orders.
99.9% Pure Copper
Black Rubber Insulated Pipe
Plastic Cap Protection
Black Rubber Pipe Insulation Benefits
Black Rubber pipe insulation provides flexible thermal and moisture protection around HVAC refrigerant tubing.
Thermal Protection
The high-density closed-cell structure helps reduce unwanted heat transfer between the refrigerant tubing and surrounding environment.
Condensation and Moisture Control
The insulation also functions as a moisture-control layer when joints, cut ends and transitions are sealed correctly.
UV-Resistant Options
UV-resistant insulation options are available for outdoor and exposed installations. Additional coating, jacketing, tape or line-set covering may still be required according to the project specification.
Flame-Performance Options
Selected insulation configurations can be supplied for requirements referencing M1 or B1 flame-performance classifications. Confirm the matching insulation material and test documentation for the exact order.
Physical Protection
Insulation helps protect the copper tubing surface from normal dust, moisture contact and handling during transportation and installation.
50 Ft Insulated Copper Pipe for HVACR Applications
The 50 ft 1/4" x 5/8" insulated copper pipe is intended for compatible HVACR equipment requiring this exact tubing size and installation length.
A 50 ft physical coil provides additional routing length between compatible indoor and outdoor equipment. Confirm that the connected system permits the planned piping route before installation.
Verify the maximum permitted piping length, vertical separation, bend requirements, insulation specification, pressure-testing procedure, evacuation requirements and additional refrigerant charge in the equipment documentation.
Available Insulated Copper Pipe Sizes
DABUND supplies multiple insulated copper pipe sizes for mini split air conditioners, heat pumps, refrigeration systems and HVACR projects. Sizes, lengths, insulation thicknesses and packaging can be customized for wholesale and OEM orders.
Size
Length
Insulation Black Rubber
Flame Resistant
1/4" + 3/8"
15 m / 20 m / 25 m / 30 m / 50 m
8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm
M1 / B1
1/4" + 1/2"
15 m / 20 m / 25 m / 30 m / 50 m
8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm
M1 / B1
1/4" + 5/8"
15 m / 20 m / 25 m / 30 m / 50 m
8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm
M1 / B1
3/8" + 5/8"
15 m / 20 m / 25 m / 30 m / 50 m
8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm
M1 / B1
3/8" + 3/4"
15 m / 20 m / 25 m / 30 m / 50 m
8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm
M1 / B1
1/2" + 3/4"
15 m / 20 m / 25 m / 30 m / 50 m
8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm
M1 / B1
3/8" + 7/8"
15 m / 20 m / 25 m / 30 m / 50 m
8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm
M1 / B1
How to Choose the Correct Insulated Copper Line Set
Copper pipe size should be selected according to the HVAC equipment documentation rather than by tonnage or BTU alone. Different equipment models can require different liquid-line and suction-line dimensions even when nominal cooling capacities are similar.
Line Set Size
Common Reference Application
Selection Note
1/4" + 3/8"
Smaller mini split and split AC systems
Check model-specific connection size
1/4" + 1/2"
Small to medium air-conditioning systems
Confirm refrigerant type and permitted line length
1/4" + 5/8"
Systems requiring 1/4" liquid line and 5/8" suction line
Use only when specified by the equipment manual
3/8" + 5/8"
Medium to larger split AC or heat-pump systems
Confirm pipe size, pressure rating and insulation thickness
3/8" + 3/4"
Higher-capacity HVAC systems
Confirm installation design and refrigerant requirements
3/8" + 7/8"
Large HVACR applications
Confirm compatibility before procurement
DABUND Insulated Copper Pipe Manufacturing
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe, air-conditioner installation kits and related HVAC parts for distributors, wholesalers, contractors, importers and OEM brands.
Integrated supply of insulated copper pipe and related HVAC products
Manufacturing and export experience since 2008
Custom logo, printing, insulation, length, packaging and carton design
Copper sizes from 1/4" to 1 1/8" and multiple coil lengths
Bulk supply for wholesalers, distributors, importers and HVAC brands
Export coordination for international orders
DABUND Factory
DABUND produces insulated copper pipe, mini split line sets, aluminum pipe and HVAC products for international B2B buyers.
SGS Certificate and Insulation Test Reports
Selected insulation configurations may have documentation referencing ASTM E84, UL 94, ASTM D1056, ASTM G21, UV resistance, flame performance and material properties. Confirm the report matching the exact insulation material and thickness ordered.
International HVAC Exhibitions
DABUND attends international HVAC exhibitions where customers can inspect insulated copper pipe, mini split line sets, air-conditioner installation kits and HVAC accessories.
Frequently Asked Questions
What does 50 ft 1/4" x 5/8" insulated copper pipe mean?
It means the product contains a 50 ft 1/4 in. copper tube and a 50 ft 5/8 in. copper tube. In compatible HVAC equipment, these tubes are used as the liquid and suction refrigerant lines.
Is this 1/4" x 5/8" copper line set suitable for every air conditioner?
No. It is suitable only for equipment that specifies a 1/4 in. liquid line and a 5/8 in. suction line. Confirm the exact connection sizes and piping requirements before ordering.
Can this insulated copper pipe be used for R410A or R32 systems?
Compatibility depends on copper wall thickness, pressure capability, tube specification and the connected equipment requirements. Confirm the refrigerant and required working pressure before ordering.
Can the full 50 ft length be used on every system?
No. The connected equipment must permit the planned 50 ft piping route. Check maximum piping length, vertical separation and additional refrigerant-charge requirements in the equipment installation manual.
What insulation thickness can DABUND supply?
Available insulation options include 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm, with selected inch-based thicknesses also available depending on the insulation material and order specification.
Is ASTM B280 copper tubing available?
Yes. ASTM B280 copper tubing configurations are available. Confirm copper material, wall thickness, pressure requirements and required test documentation before production.
Are the copper tube ends pre-flared?
The current product specification does not define pre-flared ends as a standard feature. Confirm the required end preparation and connection method when requesting a quotation.
Can DABUND print our brand name on the insulation?
Yes. Company name, brand logo, product size, meter markings and other product information can be printed on the insulation surface for OEM and private-label orders.
Can I order customized lengths?
Yes. In addition to 50 ft, DABUND can supply 15 m, 20 m, 25 m, 30 m, 50 m and customized lengths for wholesale and project orders.
Can I request a sample before a bulk order?
Yes. Qualified buyers can request samples to evaluate copper dimensions, insulation material, insulation thickness, printing and packaging before confirming a bulk order.
Related Products
Please select a data source
INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.
We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.